| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.5 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹23.5 L Quoted ₹23.8 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹25.2 LRejected-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | ₹25.2 L | L-2 | Rejected-AOC Other than L-1 |
| 3 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | SHAHDARA | DELHI | 110092 | - | - | Rejected-Technical MoU between tenderer and manufacturer (i.e., OTIS and TKE both) on Rs. 100 stamp papers as specified in BOQ Srl item No. 1.00 and 2.00 have not been uploaded |
| Sl No | Description | Qty | Unit | MB Enterprises L1 | M/s Dhapola Elevator and Engineering L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for Comprehensive Maintenance of electrically operated lifts suitable for serving passengers/ patients/ load carrying lifts installed as under by service engineers/ technically qualified team of OEM including attending the breakdown of lifts if any, complete inclusive cleaning of lift cabin, lift well and room complete all as specified and directed. Details of installed lifts are as under :-
03 Nos lift of make Tyhssenkrupp with six landings (Ground + five floor) of capacity-20 persons/ 1360 kgs, travel speed of 1.0 m/sec, Operation on 415 volts, 3 phase AC 50 Hz at Command Hospital (WC) Chandimandir.
Note: The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with original Equipment Manufactuer (OEM) i.e. ThyssenKrupp Elevators India Pvt Ltd for AMC SILVER PLAN on minimum 100 Rs stamp paper duly notarized, failing which the bid shall be laible to be rejected in technial evaluation. | 32 | EACH LIFT PER MONTH | 18,995 ₹6.1 L | 35,000 ₹11.2 L |
| 2.00 | M&L for Comprehensive Maint of electrically operated lifts suitable for serving passengers/ patients/ load carrying lifts by service engineers/ technically qualified team of OEM including attending the breakdown of lifts if any, complete inclusive cleaning of lift cabin, lift well and room complete all as specified and directed. Details of installed lifts are as under:-
02 Nos lifts of make OTIS with six landings (Ground + five floor) capacity-16 persons/ 1088 kgs, travel speed of 1.50 m/sec, Operation on 415 volts, 3 phase, AC, 50 Hz at Command Hospital (WC) Chandimandir.
Note: The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with original Equipment Manufactuer (OEM) i.e. OTIS Elevators company Ltd. for AMC GOLD PLAN on minimum 100 Rs stamp paper duly notarized, failing which the bid shall be laible to be rejected in technial evaluation. | 20 | EACH LIFT PER MONTH | 17,995 ₹3.6 L | 35,000 ₹7 L |
| 2.01Note: All items required pertaining to repair/ replacement of these lifts shall be deemed to be included in quoted rate except items covered under ser No 03 to 19 here-in-after. The comprehensive maintenance will also include checking entire system as per manufacturer's maintenance manual such as checking all parts for serviceablility, repairing/ replacement/ adjustment as per site requirement of the following : - (a) Examining, adjusting and repair/ replacement of wire ropes and chains (where fitted) as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cable and hoistway and machine room elevator wiring. | |||||
| 2.02(b) Examining, adjusting and repairing Machine Worm Gear, Thrust Bearings, Drive sheave, Drive sheave bearings, Brake Contact, Linings and components. (c) Examining and repairing Motor, Motor Generator, Motor Windings, Rotating Elements, Commentator, Brushes, Brush Holders, Bearings, Coils, Resistance for operating and Motor circuits, Magnet Frames and other Mechanical parts. | |||||
| 2.03(d) Examining and repairing Controller, selector, levelling devices, Cams, Relays, Solid state components e.g PCBs, Transducers, Resistors, Condensers, Power Amplifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel selector tapes, Mechanical and Electrical Driving Equipment. (e) Examining and repairing Governor, Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws. (f) Examining and repairing Car and Hall mechanical buttons, Car and Hall positions Indicators, Hall lanterns, Car Direction indicators and all other Car and Landing signal fixtures as installed by OEM. | |||||
| 2.04(g) Examining and repairing Deflector or secondary sheave, Bearings, Car and counterweight guide rails and buffers, top and bottom limit switches, Governor Tension sheave Assembly, Compensation sheave Assembly, Car counterweight and counterweight guide shoes including rollers or Gibs. (h) Examining and repairing Interlocks on Hoistway door, Hoistway door hangers, Guides, Automatic Power operated door operator, Car door hanger, Car Door contact, safety shoe, load weighing equipment, Car Frame, Car safety mechanism and plateform. | |||||
| 2.05(j) Providing lubricants compounded to respective OEMs stringent specifications. (k) Examining periodically all safety devices and governors and make all customary safety tests. (l) Maintenance shall be carried out under OEM overall supervision direction/ instruction. | |||||
| 2.06(m) Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (n) Rep of OEM shall submit a monthly comprehensive testing certificate to the contractor, the monthly comprehensive testing certificate shall be submitted by the contractor to the Engineer-in-Charge while claiming payments. | |||||
| 2.07PENALTY CHARGES :- (a) Within 14 days of date of commencement of work as mentioned in work order No 1, contractor shall ensure that all the lifts checked by the rep of respective OEM for comprehensive maintenance testing and system should be in working condition, all the parts of the lift should be in good conditions and a certificate to this effect shall be submitted by the OEMs and further submitted by the contractor to the Engineer-in-Charge. (b) On breakdown of the lift, action for rectification of defect/ fault by the OEM within 12 Hrs, if not attended the complaint, penalty @ Rs 1000.00 per day will be recovered from contractor. (c) If lift not made serviceable within time mentioned here-in-above at (b), the contractor should submit OEM report for delay to make lift serviceable along with duration for the unserviceability due to technical reason, otherwise penalty of Rs 2000.00 Per day will be recovered from contractor for unserviceability of lift. | |||||
| 3.00 | Supply, installation, Commissioning and Testing in repair/ replacement of Micro Processor with VVVFD and Latest Technology-Based Controller Panel complete all as specified and directed by Engineers-in-Charge. | 1 | EACH JOB | 4,95,000 ₹5.0 L | 6,500 ₹6,500 |
Updated dates
Tender Value
₹25.1 L
EMD Value
₹50,200
Closing Date
28 Feb 2026, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-97/2025-26 REPAIR/ MAINTENANCE OF ELECTRICAL DRIVEN LIFTS AT COMMAND HOSPITAL (WC) UNDER AGE EM (CH) OF GE (U) CHANDIMANDIR
2025_MES_733651_2
CWE/CHM(U)-97/2025-26
Open Tender
Electrical and Maintenance Works
330 days
GE (U) Chandimandir
Class D, Cate c(ii)
9 documents required · 9 mandatory
₹500
GE (U) Chandimandir
₹50,200
27 Apr 2026
7 Feb 2026
3 Mar 2026
7 Feb 2026
28 Feb 2026
14 Feb 2026
7 Feb 2026 - 10 Feb 2026
M&L for Comprehensive Maintenance of electrically operated lifts suitable for serving passengers/ patients/ load carrying lifts installed as under by service engineers/ technically qualified team of OEM including attending the breakdown of lifts if any, complete inclusive cleaning of lift cabin, lift well and room complete all as specified and directed. Details of installed lifts are as under :- 03 Nos lift of make Tyhssenkrupp with six landings (Ground + five floor) of capacity-20 persons/ 1360 kgs, travel speed of 1.0 m/sec, Operation on 415 volts, 3 phase AC 50 Hz at Command Hospital (WC) Chandimandir. Note: The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with original Equipment Manufactuer (OEM) i.e. ThyssenKrupp Elevators India Pvt Ltd for AMC SILVER PLAN on minimum 100 Rs stamp paper duly notarized, failing which the bid shall be laible to be rejected in technial evaluation.
M&L for Comprehensive Maint of electrically operated lifts suitable for serving passengers/ patients/ load carrying lifts by service engineers/ technically qualified team of OEM including attending the breakdown of lifts if any, complete inclusive cleaning of lift cabin, lift well and room complete all as specified and directed. Details of installed lifts are as under:- 02 Nos lifts of make OTIS with six landings (Ground + five floor) capacity-16 persons/ 1088 kgs, travel speed of 1.50 m/sec, Operation on 415 volts, 3 phase, AC, 50 Hz at Command Hospital (WC) Chandimandir. Note: The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with original Equipment Manufactuer (OEM) i.e. OTIS Elevators company Ltd. for AMC GOLD PLAN on minimum 100 Rs stamp paper duly notarized, failing which the bid shall be laible to be rejected in technial evaluation.
(b) Examining, adjusting and repairing Machine Worm Gear, Thrust Bearings, Drive sheave, Drive sheave bearings, Brake Contact, Linings and components. (c) Examining and repairing Motor, Motor Generator, Motor Windings, Rotating Elements, Commentator, Brushes, Brush Holders, Bearings, Coils, Resistance for operating and Motor circuits, Magnet Frames and other Mechanical parts.
(g) Examining and repairing Deflector or secondary sheave, Bearings, Car and counterweight guide rails and buffers, top and bottom limit switches, Governor Tension sheave Assembly, Compensation sheave Assembly, Car counterweight and counterweight guide shoes including rollers or Gibs. (h) Examining and repairing Interlocks on Hoistway door, Hoistway door hangers, Guides, Automatic Power operated door operator, Car door hanger, Car Door contact, safety shoe, load weighing equipment, Car Frame, Car safety mechanism and plateform.
(j) Providing lubricants compounded to respective OEMs stringent specifications. (k) Examining periodically all safety devices and governors and make all customary safety tests. (l) Maintenance shall be carried out under OEM overall supervision direction/ instruction.
(m) Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (n) Rep of OEM shall submit a monthly comprehensive testing certificate to the contractor, the monthly comprehensive testing certificate shall be submitted by the contractor to the Engineer-in-Charge while claiming payments.
PENALTY CHARGES :- (a) Within 14 days of date of commencement of work as mentioned in work order No 1, contractor shall ensure that all the lifts checked by the rep of respective OEM for comprehensive maintenance testing and system should be in working condition, all the parts of the lift should be in good conditions and a certificate to this effect shall be submitted by the OEMs and further submitted by the contractor to the Engineer-in-Charge. (b) On breakdown of the lift, action for rectification of defect/ fault by the OEM within 12 Hrs, if not attended the complaint, penalty @ Rs 1000.00 per day will be recovered from contractor. (c) If lift not made serviceable within time mentioned here-in-above at (b), the contractor should submit OEM report for delay to make lift serviceable along with duration for the unserviceability due to technical reason, otherwise penalty of Rs 2000.00 Per day will be recovered from contractor for unserviceability of lift.
Supply, installation, Commissioning and Testing in repair/ replacement of Micro Processor with VVVFD and Latest Technology-Based Controller Panel complete all as specified and directed by Engineers-in-Charge.
Supply & fixing in replacement of full length IR door Sensor 12V/ 0.2A with 20 number of Diodes complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Reed switch suitable for 16/20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of defective travelling Cable PVC insulated flexible flat copper conductor of size 4 Core x 0.75 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply, installation, Commissioning and Testing in replacement of ARD (Automatic Rescue Device) 1.5 KVA with Battery 12 Volt 180 AH suitable for 16/ 20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Landing Operating Panel (LOP) with digital indicator for counting of floors up and Down & up, down complete all as specified and directed by Engineer-in-Charge.
Suuply, Installation, Commissioning and Testing in replacement of latest technology based Cabin Operating Panel (COP) for 16/ 20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of robust MS Car Door Seal of 16/ 20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of robust MS Landing Door Seal of 16/ 20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair/replacement of Power Contactor Model No LCI-D80116F5 or equivalent in performance as approved by GE for elevator complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of LB-II Card (PCB for Elevator) Complete suitable for 16/ 20 Passengers lift complete all as specified and directed by Engineer-in-Charge.
Suply and fixing in replacement of Upper and Lower limit switch suitable for 16/ 20 Passenger lift complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Door Spring 800CO as per sample suitable for 16/ 20 Passengers lifts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Over Speed Governor Assembly 1.00 mps including OSG unit, pit pulley, auto limit switches etc. complete set all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Encoder Assembly with all fixing accessories complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Overload Warning Indicator System with complete accessories complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of lift rope complete in all respect for one lift (Total six landing) as per manufacturer's recommendation complete set all as specified and directed by Engineer-in-Charge.
NOTE:- Spare parts of Lifts as specified under serial item no 3.00 to 19.00 here-in-before shall be of OEM (i.e. ThyssenKrupp Elevators India or OTIS Elevators company Ltd., whichever is applicable) Only. Contractor shall keep this aspect in mind while quoting the rates against each item above.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tenderdocuments97.pdf
Tender Documents • 0.56 MB
Additional97.pdf
Additional Documents • 0.44 MB
BOQ_841948.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid