Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.2 L+₹2.2 L (6.24%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.0 L+₹4.1 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.4 L+₹4.5 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹42.2 L+₹6.3 L (17.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.9 L
EMD Value
₹97,700
Closing Date
6 Sept 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS TO WATER SUPPLY INSTALLATIONS AND PIPE LINE, BOREWELLS AT DMRL AND ADJOINING AREA INCLUDING OUTSOURCING SERVICES FOR WATER SUPPLY INSTALLATION AND CONNECTED UNITS AT DMRL AREA AT KANCHANBAGH, HYDERABAD
2021_MES_466395_1
GE I KBAGH TOKEN 37 OF 2021 2022
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹97,700
Yes
27 Sept 2021
9 Aug 2021
8 Sept 2021
9 Aug 2021
6 Sept 2021
23 Aug 2021
9 Aug 2021 - 20 Aug 2021
Amount
Excavation in trenches not exceeding 1.5 meters wide and not exceeding 1.5 meters in depth and getting out in hard/ dense soil complete all as directed.
All as per srl item No.1 here- in -before but depth exceeding 1.5m but n.exc 3m complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick using soil complete all as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed.
Supply & laying GI pipe of 50mm dia, medium grade with all Fittings such as elbows,tees, unions, short pieces, bends, etc., including taking down old GI pipe complete all as directed. Note:- (i) Earth work shall be measured & paid separately under respective items
All as per srl item No.5 here- in -before but but for GI Pipe of 25mm dia size.
All as per srl item No.5 here- in -before but but for GI Pipe of 20 mm dia size.
S&F in repairs GI Tee, Union, Elbow, Reducer, Nipple for HDPE Tank, socket, Reducer Elbow, Running nipple upto 100 mm long with both ends threaded suitable including cutting, rethreading the existing pipe of the following size complete all as directed.
15/20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Taking out existing unserviceable gate valve from pipe lines and supply & fix new gunmetal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe with necessary fittings required for the following size complete all as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F in repairs PVC float valve assembly including necessary fittings such as sockets, nipples wherever necessary for the following size complete all as directed. MAKE:- PRAYAG OR Equivalent
25 mm bore
20 mm bore
15 mm bore
Taking out water sample in clean sterilised container and getting tested from the Department of waste water examiner, Institute of preventive medicine at Narayanaguda, Hyderabad (or) NRDC Himayatnagar, Hyderabad for ‘BACTERIOLOGICAL TEST’ and submission of Test report to the Engineer-in-charge, complete all as directed. Note:(i) Testing charges shall be borne by contractor. (ii) Quoted rates are deemed to be iclusive of testing charges.
Taking out water sample in clean sterilised container and getting tested from the Department of waste water examiner, Institute of preventive medicine at Narayanaguda, Hyderabad (or) NRDC Himayatnagar, Hyderabad for ‘CHEMICAL TEST’ and submission of Test report to the Engineer-in-charge, complete all as directed. Note:(i) Testing charges shall be borne by contractor. (ii) Quoted rates are deemed to be iclusive of testing charges.
Taking out /lowering down the submersible pump set of any capacity/HP/stage/any make from any depth including disconnecting the water , power supply mains for examination/ and lowering down and connecting the same after repairs complete all as directed. Note:- (i)Cost of equipment like tripod and chain pulling block etc required for this job shall be deemed to be included in the quoted rate.(ii) Repairs shall be measured & paid separately under respective items.
M&L for repairs to the submersible pump set of 3 to 5 HP capacity by, Renewal of impeller, bearing, repair to shaft (including Lathe machine work) complete all as directed.
Rewinding of motor of open well /submersible pump set with insulated copper wire of existing gauge and quantity for 3 to 5 HP capacity , including re-assembling, testing and commissioning complete all as directed.
M&L for flushing out the existing 150mm dia bore well for flushing out sand, mud with drilling machine till clean water is obtained complete all as directed. Note:- Taking out and lowering down of submersible pumpset,pipe and electrical connection shall be measured and paid seperately.
M&L for repairs to the submersible pump set of 7.5 HP to 10 HP capacity and Renewal of impeller, bearing, repair to shaft complete all as directed
Rewinding of motor of submersible pump set with PVC insulated copper wire of existing gauge and quantity for 7.5HP to 10 HP capacity, including re-assembling, testing and commissioning complete all as directed.
M&L for cable joint water proof type with complete jointing materials suitable for 3 core, 2.5 to 3.0 Sqmm cable complete all as directed. MAKE: -M-SEAL/REYCHEM/ DENSON
M&L for bailing out water, scraping and cleaning the internal surface of RCC underground sump/ of one Lakh gallon capacity by using bleaching powder, scrapping, removing the scales, washing out with water complete all as directed. Note :- (i) Pump for Bailing out water with all provision shall be provided by the contactor without any extra cost. (ii) Disinfectant shall be as approved by Engineer-in-charge
All as per srl item No. 18 here-in-before but for RCC over head water tank of one lakh gallons capacity at 40 feet height.
All as per srl item No. 18 here-in-before but for RCC over head tank of 50,000 gallons capacity at 40 feet height.
Taking out unserviceable DOL /Star delta starter of 3 phase, 440 Volts and replace with new DOL starter suitable for following capacity submersible pumps including all internal connection with copper wire, testing and commissioning complete all as directed. MAKE:- L&T/ CG
3 HP to 6 HP
7.5 HP to 10 HP capacity
Replacement of unserviceable star rubber couplings for centrifugal pump sets, of any make/model, for for the following capacity pump set.
3 HP to 5 HP
7.5 HP to 10 HP
Taking out unserviceable double flanged check valves/ butterfly valves and S & F Butterfly Valve of following size complete all as directed. MAKE:-ZOLOTO/DURGA/KIRLOSKER/AUDCO
80 mm dia
100 mm dia
M & L for run lead joints for spigot and socket pipes and fittings of the following size of pipes including buring out existing joint complete all as directed.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Cutting CI pipes in position, reducing to required length for inserting of new CI Specials, branches etc. of the following size pipes:- Note: CI specials shall be measured & paid under relevant item.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge not less than 1.5 m below ground level connected to GI earth strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by 40mm dia GI pipe, light grade including necessary earthwork,RFR,and removal, PCC 1:3:6 chamber and RCC 1:2:4 cover slab 50mm thick with TMT bars of 8mm dia @ 100mm c/c both ways, GI watering pipe of 20mm dia medium grade, funnel, wire mesh, salt, charcoal all as shown in electrical plate No.3 of SSR Part-I complete all as directed and testing on completion.
Taking out existing damaged valve chamber cover and Supply & Fix new valve chamber cover of size 1mtr x1.2 mtr made out of 3 mm thick MS sheet along with angle iron frame of size 40x40x6mm, embedded in 1:2:4 coping, handle, necessary fabrication, provision of arrangement of locking system including applying two coats of synthetic enamel paint over a coat of red oxide primer to steel surface and 3 coats of white wash of coping complete all as directed.
M&L for Painting of existing valve chamber cover of size 1mtrs x1.2 mtr made out of MS sheet incl preparation removing of rust /dust or grease from the surface and applying one coat of anticorrosive synthetic enamel paint, both internal and external complete all as directed.
M&L for CI spigot and socket pipes such as bends, tapers ( any type, radius and angle ) Tee, collars caps and plugs for CI pipes upto 200mm bore complete all as directed by Engr-in-Charge. Make- ELECTRO STEEL CASTING LTD/TISCO/KARTAR/KESORAM Note :- (a) Run lead joints will be measured and paid separately under relevant items of this schedule. (b) Earth work shall be measured and paid separately.
Supply & laying of MS pipes with flange joints on both ends alongwith neoprene rubber gasket, nuts, bolts & washer, in any length, laid in trenches and provision of two coats of synthetic enamel paint over a coat red oxide primer including taking down old MS pipe of following size :-
100 mm dia
150 mm dia
200 mm dia Note for item 35.01 to 35.03 :- (a) Earth work shall be measured and paid separately. (b) Flange joints shall be measured and paid separately. Make: JINDAL/ TATA
S&F in repairs impeller for any make/type suitable to existing pump of the following capacity complete all as directed.
2 to 5 HP capacity
7.5 to 10 HP capacity
25 to 30 HP capacity
Taking out mono block pump set/ centrifugal pump set of the following capacities from their installed position, shifted to workshop for overhauling including replacing of bearings, gland, bush, nuts, bolts and refixing in its original position and testing complete all as directed. Note:- Cost of spares related to this job shall be included in quoted rate. Job includes cutting of old nuts/bolts rethreading the pump set base for fixing nuts/bolts etc complete.
2 HP to 5 HP capacity
7.5 to 10 HP capacity
25 to 30 HP capacity
Disconnecting the water, power supply mains of the follwing capacity motors of Mono block/Centrifugal pump sets and shifting to workshop for rewinding of motor with copper wire with same number of turns and thickness as existing type of any make/ model including reinstalling, oven during testing and commissioning complete all as directed.
Up to 5HP Capacity
7.5 to 10 HP capacity
25 to 30 HP capacity
Disconnecting and taking out the old unserviceable sluice valve from the existing pipe line and S&F CI sluice valve of 200 mm dia confirming to IS 780 with all connected accessories complete all as directed. Make:- KARTAR/ DURGA/ KIRLOSKAR
All as per srl item No. 44 here-in-before but of 150 mm dia sluice valve
All as per srl item No. 44 here-in-before but of 100 mm dia sluice valve
All as per srl item No. 44 here-in-beforebut of 80 mm dia sluice valve
All as per srl item No. 44 here-in-before but for 50 mm dia sluice valve
Supply & fix in repairs gun metal Non-return Valve, 50 mm dia, ISI marked, screwed both ends for iron pipe of the following size with necessary fittings complete all as directed. MAKE : JINDAL/ ZOLOTO/ NETA/ LEADER
Taking down the unserviceable Control Panel board for submersible pump set and supply, fixing, testing & commissioning of Control Panel board of size 500x 750 x 300 mm with angle iron frame, pedestal type, made out of 2mm thick MS Sheet with 50 x 50 x 6mm thick angle iron - 02 nos Legs duly embedded in ground with PCC foundation and other end welded to panel board including applying two coats of synthetic enamel paint over one coat of red oxide primer to steel surface and front openable door type with sliding bolts complete all as directed. The Panel board shall include following items. (a) MCB TPN 63 Amps - 01 No, (b) DOL Starter 3 to 7.5 HP - 01 No, (c) Ammeter 0 to 15 Amps - 1 No, (d) Voltmeter 0 to 500 V- 01 No, (e) Single Phase Preventer - 01 No, (f) Indication Lamp (RYB) - 03Nos.
Taking out old unserviceable ammeter 0 to 30 Amps from panel board and replacement of the same with new ammeter of same size and capacity complete all as directed. MAKE : AE/ LT/CROMPTON
Taking out old unserviceable volt meter 0 to 500 Volts and replacement of the same with new volt meter of same capacity suitable for existing panel board complete all as directed. MAKE : AE/ LT/CROMPTON
M&L for repairing, Jointing, Arresting the leakages of existing GI Pipe line of size 15mm to 25mm dia complete all as directed. Note :- Quoted rate is deemed to be included the cost of necessary excavation/ returning /refilling and Fittings such as Union, socket etc for restricting the leakage.
All as per srl item No. 53 here-in-before but for pipe of 40 mm to 50 mm dia.
Supply and laying of HDPE pipe of follwing size, withstanding pressure rating 16 Kgf/sqcm in Borewell slot/as per site requirement with all connected fitting accessories including taking out old unserviceable pipe complete all as directed.
65 mm dia
50 mm dia.
Removing of unserviceable spindle with check nut from sluice valve and S&F new spindle with check nut, bolt, washers and gland packing and rubber gasket and necessary arrangement for stopping leakage complete all as directed for follwing size of sluice valves:-
80 mm bore
100 mm bore
150 mm bore
200/250 mm bore
Removing unserviceable PVC water proof cable of any size and S&F new PVC water proof copper cable of size 3 core 4 sqmm copper conductor suitable for submersible pump set complete all as directed. MAKE:- FINOLEX/FINECAB/POLYCAB
Supplying only Puri Chlor brand Calcium Hypochlorite 65%-70% Chlorine content in Granular form to mix with drinking water received at Pump house for maintaining water purity and PPM, complete all as directed Make: Sree Rayalseema Hi-Strength Hypo Ltd.,
M&L for dismantling old valve chamber and material and labour for construction of brick masonry new valve pit chamber of size 900mmx900mmx900mm (internal), 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate, providing with old size fly ash bricks masonry wall of 230mm thick built in CM 1:6, rendering 15mm thick in CM 1:6 finished even and smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even externally and plaster shall be done 150 mm below ground level, supply and fix 2mm thick MS sheet steel cover fixed on 40x40x6mm angle iron frame embedded in PCC 1:2:4 coping with locking arrangement and MS hold fast and handle made out of 25x6mm flat iron, applying two coats of synthetic enamel paint of approved shade over a coat of primer (red oxide) to all exposed steel surfaces and applying three coats of white wash to exposed plastered surfaces and making good all disturbed suface to match surrounding complete all as directed.
Disconnecting electrical connections and taking down existing unserviceable 3-pole Power Contactor and S&F new 3-pole Power contactor, 3-phase, 415 volts, 50Hz suitable to existing motor including connecting, testing complete all as directed. MAKE :MNX-70 of L & T OR Equivalent
Disconnecting electrical connections and taking down existing unserviceable 3-pole Power Contacter, and S & F new 3-pole Power contacter 3-phase , 415 volts, 50Hz suitable for existing motor including connecting, testing complete all as directed. MAKE : MNX- 45 of L& T OR Equivalent
S&F in repairs ON/OFF Timer 0-60 seconds suitable for 3-phase, 415volts, 50Hz, 3-pole Power contacter MNX type for existing motor including connecting, testing complete all as directed. MAKE : L& T OR it's Equivalent
Renewal of worn out gland packing with “T” bolt and nuts, rubber packing and necessary arrangements for stopping the leakage of sluice valve of size 80/100mm dia complete all as directed.
Renewal of worn out gland packing “T” bolt and nuts, rubber packing and necessary arrangements for stopping the leakage of CI sluice valves of size 150/200/250mm dia
Opening the bearing cover of the centrifugal pump set of 25 to 30HP capacity, greasing the same and refixing in its original position complete all as directed.
Opeining the unserviceable bearing from the centrifugal pump set and S & f new bearing set sutiable to motor/ pump set of capacity 25/30 HP including re-alignment of the pump and motor complete all as directed.
Disconnecting and taking out unserviceable existing foot valve from the sump and S&F new foot valve of size 80mm dia, heavy duty including necessary gasket, nut, bolts etc complet all as directed.
M&L for painting of the following pump sets with one coat of approved synthetic enamel paint including scrapping rubbing removing of dust, grease, etc., complete all as directed.
Pump set 5/7.5/10 HP including motor and base frame
25/30 HP pump set including motor and base frame
S & F stop valves of cast copper alloy, screwed down with high pressure with crutch & butterfly handle, screwed both ends for the following dia GI pipes or for unions fixed, including taking down old unserviceable stop valve complete all as directed.
15 mm dia
20 mm dia
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impactand corrion resistant including thermal management in multiple optics complete with Ip 65/66 protection complete. Make:- Havell's, Phillips/CG or equivalent
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impactand corrion resistant including thermal management in multiple optics complete with Ip 65/66 protection complete. Make:- Havell's, Phillips/CG or equivalent
Supply & fixing LED flood Light 120 Watt 230 V AC outdoor type with thermal managemant in multiple optics and equiped with IP66 protection,with impact and corrosion resistant complete with driver and lamp. Make:- Havell's, Phillips/CG or equivalent
Supply and fixing post top lantern LED type 40 watt 230 watt voltas AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp. Make:- Havell's, Phillips/CG or equivalent
M&L for taking down,repair and refix the same on same location after replacement of unserviceable of Drive of 36 watt/50/75Watt of LED street light fitting/ flood light/any other type LED fitting by upto 250Watt capacity complete all as specified and directed.
M&L for taking down, repair and refix the same on same location after replacement of unserviceable of Drive of 100/150Watt of LED street light fitting/ flood light/any other type LED fitting by upto 250Watt capacity complete all as specified and directed.
Supply anfd fix surge arrestor of 5KV/10KV for LED type fittings.
M&L for repair of mechanism of High mast and rewinding of three phase tower motor 440volt AC if burnt and incl. dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
M&L for general servicing of Highmast including oiling, greasing, allignment of Light holdering, servicibility of electric motor,servicibility of gear system,functionality of rope wire and other connected work for servicibility of highmast all as per directed
S&F in repair GI pipe bracket, made out of 40 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls as directed by Engineer-in-Charge.
All as per item No. 78 above but made out of 25mm bore pipe.
S&F in replacement, MS clamps, made out of flat iron suitable for PCC/ Steel tubular pole, fabricated into shape and size as required suitable for street light brackets of GI pipe 40/25 mm bore, with MS nuts & bolts including painting with one coat of red oxide primer and two coats of aluminium paint all as directed by EIC.
Supply and fix in repairs, 4 sqmm 2 core, LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Supply and fix in repairs, 6 sqmm 2 core, LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Supplyand fix in repairs, 10sqmm 2 core,LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Comprehensive Annual Maintenance of RO Plant Make- ION Exchange Plant scheme-NGMA-20-NGMF20-INDRO-401 installed at ATC Devetalagutta Married accommodation area including checking, testing, cleaning of Filter, chemical filling, gasket fitting complete membrance of plant by carrying out Inspection visit and service visit quarterly complete along with attending breakdown on phone calls along with maintaining log sheet of plant all as directed.
Note :-(i) (a) Visits – (Including Service and Inspections) (b) Break Down calls will be attended under AMC Two calls (excluding annual visit 4 Nos) (c) LOGSHEET for analysis purpose shall be maintained. (d) Provision of tools-tackles & labour. (e) Physical inspection for system and related things like Dosing systems, carbon filters and entire Plant (f) Observation of Pressure at Sand Filter Inlet / Outlet and System Pressure. (g) RO Membrane Cleaning (h) Open backwash for Sand filter and Carbon Filter. (j) Checking Method of operation and necessary advice will be given to operation staff.(k) Training to Staff and Operators (l) Audit Reports and Suggestions (m) Pump servicing in ION Exchange scope (Feed Pump & Transfer Pump). (ii) Scope of Supply of material (i) Membrane Cleaning Chemicals – 6Kgs – (Ion Exchange Make). (ii) Antiscalent (8111) - 30 Kgs – (Ion Exchange Make) (iii)Cartridges – Ion Exchange Make – 6 Nos. (iv) Instrument (Conductivity Meter) Calibration. (v) Water Analysis Reports Note : Membrance of size 4" is not included in the scope of work and will be measured & paid separately under relevant item of this schedule.
Supply only Membrance of size 4" for RO plant complete all as specified and directed . Make- ION Exchange or equivalent
Outsourcing of services for running of centrifugal/monoblock pumps in Pump house, external water supply system including maintenance of pump house at DMRL area and regulating of water supply by operating of any type/ size sluice valve, gate valve pumping to the service tanks attending and rectifying of complaints regarding of pumping and supply of water to entire DMRL area, every day water meter reading , water testing (Chlorine,) and adding prescribed quantity of Calcium Hypochlorite 65%-70% Chlorine content, mixing register shall be put up to concerned JE after completing the Testing (Testing done before distribution of water every day). water test Kit shall be provided by the Contractor to the Operators, and cost of the same shall be included in the quoted rate. Calcium Hypochlorite 65%-70% Chlorine content shall be provided by the department (which shall be measured and paid under relevant item) and for running/ routine maintenance of standby DG set 40 KVA as and when required, battery charging, filling up of HSD, water, maintaining of log book & POL record complete all as directed by Engr-in charge including Sunday & Holidays in Man power Deployed : FGM (semi skilled) -03 Nos - (1st shift 0600h to 1400h & 2nd shift from 1400 hrs 2200hrs,3rd shift from 2200 hrs 0600hrs). 01No. per shift
Outsourcing of services for maintenance of entire external electric supply system for 11/0.433KV substation of “PM Plant” building having 01 MVA of 11/0.433KV capacity transformer comprising HT panel with ACB, PT’s, CT’s, HT joints HT/LT cables, battery bank with battery charger, LT panel board with switches metering protection system, earth pits of all the equipment & maintaining of earth testing registers etc. maintaining daily records of all electric supply with all parameters described at the substation, daily maintenance of the complete surrounding area of the PM plant substation and for running/routine maintenance of stand by DG set, battery charging, filling up of HSD, water, maintaining of log book & POL record of capacity 500 KVA, attending daily electric complaints on all days round the clock including Sunday & holidays in three shifts (Man power Deployed :Semi skilled) -03 Nos - (1st shift 0600h to 1400h & 2nd shift from 1400 hrs 2200hrs, 3rd shift from 2200 hrs 0600hrs). 01No. per shift complete all as directed.
Outsourcing of services for running of borewells installed at CGHS Hospital premises, Bldg No. 124, Papu Bldg, New HIP and DSC Lines Area and regular water supply to Appollo Doctors Qtrs Area & DSC lines, maintenance of diesel engine driven generating sets including operating of DG set whenever power supply fails, recording of various meter reading of generating set and panel board, daily maintenance of DG sets, batteries, charging and filling up of HSD, water, maintaining log book, POL record etc., of DG sets in DMRL area of capacity 250 KVA at TEF Bldg, 625 KVA at New HIP bldg & 250 KVA at 130 Bldg by employing one FGM (Semi skilled) on all days in general shifts (general shift from 0900h to 1700h) on all days including sunday and holidays complete all as directed by Engr-in-charge. Man power Deployed : FGM (Semi skilled) -01 No.
Outsourcing of services for running of borewells at ERG, PM Plant, Post No 1 and Foundary and running/maintenance of diesel engine driven generating set 320 KVA installed at Bldg No 9 & 200 KVA installed at admin bldg whenever power supply fails, recording of various meter reading of generating set and panel board, daily maintenance of DG sets, batteries, charging and filling up of HSD, water, maintaining log book, POL record etc., on all days in general shift (general shift from 0900h to 1700h) complete all as directed by Engr-in-charge. Man power Deployed :FGM(Semi skilled) -01 Nos
Outsourcing of services for attending electrical complaints lodged at MES Service Centre from users of DMRL complex area under AGE E/M-I, GE(I) R&D Kanchanbagh by way of receiving the complaints from users and update the same as and when rectified and submitting completion report duly signed by the occupants including electrical repair work of any defective wiring in buildings, service connection cables, main switches, DB’s replacing fuses and switching on/off of street lights at DMRL complex area under AGE E/M-I,GE(I) R&D Kanchanbagh including checking repair and maintenance to LT/ HT over head lines, UG Cables, feeder pillar boxes, bus bars,GOD’s etc connected with external electric supply during the shift periods as mentioned below on all days including sunday & holidays complete all as directed by Engr-in-Charge for area as mentioned below :- (a) Attending all HT/LT installations as indicated above located at DMRL (General shift from 0900h to 1700h, i.e. Electricans(semi skilled)-01 Nos, Helper(unskilled)-01Nos. NOTE: - Tradesmen shall be assisted by unskilled person as per trade practice and safety norms.
Note for Item No.76 to 80 :- (i) In case of requirement tradesmen provided for one area may be utilised in other areas at the discretion of the department without any extra cost to department as directed by Engr-in-charge. (ii) Material required for maintenance of DG Set i. e. Diesel,Oil, Distilled Water etc shall be supplied by the department. (iii) Rate quoted is deemed to be included for leave reserve / off of the staff employed. (iv) On the Instruction of concerned JE, If any DG Set battery is not charged fully then the Operators should shift other DG Set battery OR Charger to this place & vice versa. (v) The materials required for the area cleaning and Diesel Generator Set cleaning (Cotton Waste, Brooms and Carbon Cleaner for Battery terminals and water pipe for watering in earth pits shall be provided by the Contractor and cost of cleaning materials and pipe, provision of Printed Log Books & Stationery required shall be included in the quoted rate. (vi) All staff employed is responsible for cleaning and maintenance including restricting vegetation growth at Installation surrounding area. (vii) Uniform shall be provided by the contractor. (viii) The necessary Tools & plants shall be provided by the contractor.
(ix) The contractor should submit the qualification details & ID Proof of Person Employed. The payment shall not be less than minimum labour wages, Documentary proof Aadhar linked on line payment proof duly highlighted the names in the statement shall be submitted alongwith attendance register EPF Statement, ESIC statement for releasing the payment. (x) Group insurance and PF for staff shall be provided by the contractor. Documentary proof shall be submitted to the department. (xi) In case absence of operator, double the rate quoted will be recovered. (xii) Deparmental equipments of each installation, shall be under safe custody, In case of theft of any item from installation recovery shall be made from the contractor as per direction of Engr-in-charge. (xiii) Qualification/ Experience certificate (minimum 05 years) with age not more than 60 years of all staff employed shall be submitted. (xiv) The person employed for one Job shall not be disturbed by contractor for other works of contracts. (xv) After handing over duty to Reliever only, the duty person should leave the installation in Shift duties. (xvi) Rate quoted deemed to be inclusive of all taxes.
Note for srl item Nos.76 to 80: The rate quoted shall not be less than minimum wages as notified by Government of India/State Government/ Local body whichever is higher including EPF, ESI and other statutory benfits if any. In case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/ Local body whichever is higher including EPF & ESI, his tender will be treated as non-bonafide and will be rejected during financial evaluation. In such case, the lowest tenderer shall be determined by the lowest amount amongst valid bonafide bids only.
Note: 1. Contractor shall quote cumulative of basic rate, VDA , employers contribution towards EPF liability, contribution towards ESIC, contribution towards bonus, over head and profit as applicable as per instruction in vogue including all Taxes, Cess, Levies as applicable including GST. 2. Monthly wages shall be paid by the contractor to the workers/labour only online. Proof of statutory deductions in favour of workers/labour shall be submitted by the contractor to the GE. The contractor will be required to submit copy of valid labour licence from the labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period the contact shall be liable to be cancelled and the performance Secuirty of the firm shall be forfeited accordingly. Reference is also invited to this HQ letter No.A/37696/Gen/Pol/E2W(PPC) dated 27 July 2017 as amended vide letter of even No. dated 09 May 2018.
CHITRA ENGINEERING CORPORATION
hari enterprises
Bismi Engineering
M/s K L M INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .