Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.4 L+₹52,260 (6.60%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹8.5 L+₹54,700 (6.90%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹8.5 L+₹60,530 (7.64%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹8.7 L+₹81,570 (10.3%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
16 Dec 2024, 3:00 pmClosed
Shri Shubham Yadav,AEEE
Chikkbanavara Post Bangalore, PIN- 560 090
REPAIR AND MAINTAINCE OF PERIMITER SECURITY LIGHTS, STREET LIGHTS,SOLAR LIGHTS, SOLAR WATER HEATERS AND OTHER MISC WORKS AT 2AFSB MYSORE
2024_MES_683680_1
8735/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE I (AF) Chimney Hills, Bangalore
₹16,000
Yes
15 Jan 2025
13 Nov 2024
23 Dec 2024
13 Nov 2024
16 Dec 2024
2 Dec 2024
13 Nov 2024 - 26 Nov 2024
Amount
M & L for servicing of Solar street light fitting of 2x11/1x11 watt capacity including servicing of module cleaning, battery inspection, checking of distilled water in battery , inspection of electronic circuits etc.
Supply & Fix in repair battery box for battery housing suitable for solar light fittings
Supply & Fix in repair battery 110 AH 12 Volts suitable for solar lights
Supply and pore battery electrolyte (distilled water with acid) once in every quarter for each battery
Supply & Fix in repair luminaire assembley for 1x11 watt LED lamps (new solar light fittings) with complete accessories all as specified and as directed.
M & L for repairs to solar water heater system by checking the leakage / sepage of the system if found rectified through the authorised dealers. Draining out the system by opening the cold water out let and hose to the bottom tank,dry out the system refilling the same after rectifing the leakes ,topping up with anti freeze solution of soft water,check the corrosion sacrificial anode,replace if found defective,clean the collector of capacity 100 LPD complete all as specified and as directed.
All as per Item ser No 6 here in before but capacity of 200 LPD
All as per Item ser No 6 here in before but capacity of 500 LPD
Supply and laying in repair CPVC pipes 20mm, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S&F in repairs CPVC Ball valve suitable for 20mm dia pipe complete all as specified and directed
S & F framed work such as grills, gratings, etc., with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks .
S & F in repair toughened Glass 6mm for Solar Water Heater Flat Plate collector, fix and seal as recommended by the manufacturer and all as directed
Taking down the defective / unserviceable street light/perimeter light/Garden light/Bollards/Flood lights fittings of any wattage, from the buildings/poles/post tops for repair and refixing the same after carrying out repair (replacement of spares like LED driver, surge arrestor, etc shall be measured and paid seperately) including attending complaints received through online for non-ops lights
S & F in replacement die cast aluminium IP66 LED Flood Light luminaire, 150 Watt capacity all as specified and directed Make : Cat part No: JETAIRISFLS150WLED757PSYMLTG of Havells or eqvt in CG / Philips
Supply and fix in replacement LED street light 60 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 Make:- Havells Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Crompton/ Phillips
All as per Item Ser No 3 here in before but capacity of 25 watts
S& F in replacement Bollards fittings 8 watt, IP 65, diffuser at the upper portion acts as a beacon of path guidance and necessary PCC foundation (of size 20x20x20 CM type C1 using 12.5 mm graded stone aggregate) for fixing including necessary cable connections all as directed. Make : Havells cat part No CONEBLS8WLED830PSYMTOPC(0.6M) or equivalent in Phillips/Bajaj as approved by Engr-in-Charge
S&F in replacement LED Post top lantern 15 watt, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. Make : Havells cat part No CORALMINIPT15WLED757PSYMYOPC or equivalent in Phillips/Bajaj as approved by Engr-in-Charge
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core including dismantling of old U/S cable
All as per item no. 19 above but 16 Sqmm 2 core
All as per item no. 19 above but 16 Sqmm 4 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay brunt bricks class 'B' of standard size in trenches for protection of UG cable.
Supply and spread dry clean fine stone dust in trenches as cable cushioning to UG cable all as per clause 19.75 of SSR part -I
M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary .
Supply and fix in repair GI tubing 40 mm bore, light grade fixed to wall/floor and laid in trench complete for cable protection including fixing arrangements.
S & F for Hard PVC junction box of size 200x150x150 mm weather proof with three phase and neutral link connector and necessary cable gland- 2 Nos for LT UG cable 10/16 sqmm 2/4 core and locking arrangement and fixing with existing PCC / steel tubular electric pole above the copping with suitable MS clamps, nuts & bolts and necessary electric connection etc.complete all as specified and directed
M & L in replacement sub main wiring with two single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor FRLS cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings complete all as specified and directed. Note:- Two runs of 1.5 sqmm, one run of 1.5 sqmm conductors and one run of PVC conduit shall be measured as one unit
S & F GI pipe bracket 40 mm medium grade dia not exceeding 1.2 mtrs long bend to shape suitable for fixing street light to PCC/steel pole including suitable size MS clamps, bolts, nuts, washers, etc
Supply & Fix in repair LED driver suitable for 60 watt street light fitting, 240 Volts, 50 Hz complete all as specified and directed
S&F in repair of Addressable break glass Manual call point,Dimensions Semi -Flush Mounting Size in MM 89*93*27.5 mm(WxHxD),IP Rating IP 24D,Operating temprature 15 V to 32 V dc Max and commissiong existing panel by given Adress complete all as specified and directed Fire Alaram System Make :- Honeywell(Morley IAS)
Supply and installation of 4 core 1.5 Sqmm Armoured FRLS Copper Cable for Fire alaram system complete all as specified and directed.
Repair and service of Morley DXC1 single loop fire alaram panel two loop card inbuilt addressable point 99 detectors and 99 devices per loop.6*40 Character blue crystal display with backlight illumination 2 sounder circuits with software updating complete all as specified and directed. Make :- Honeywell (morley IAS) Note :- Min 3 Months service warranty after servicing date. Service will be done only through above specified Honeywell Brand.Third party companies not acccepted for this item.
eurekaenterprises (BID ID -3181753)
KUZHIKKAL ENTERPRISES (BID ID -3181206)
Power and Telecom Systems (BID ID -3180243)
SRI AYYAPPA ENTERPRISES (BID ID -3182448)
JM Engineering (BID ID -3182396)
PLATINUM CONSTRUCTIONS (BID ID -3182263)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .