Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Admitted-Finance | |
| 2 | L2₹1.2 Cr+₹1.9 L (1.55%)Admitted-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Admitted-Finance | |
| 3 | L3₹1.3 Cr+₹5.3 L (4.42%)Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Admitted-Finance | |
| 4 | L4₹1.3 Cr+₹12.7 L (10.5%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹1.4 Cr+₹15.1 L (12.5%)Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | mayur enterprises L5 | Vijay Electricals L1 | M/s JAIMAA ASSOCIATES L4 | Commercial Traders L3 | Leo Air and Power Solution pvt Ltd. L6 | BRIJ MOHAN LAL AND CO. L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out old existing 11 KV UG Cable of size 300 sqmm 3 core at site from trenches complete all as specified and directed. | 5,200 | RM | 100 ₹5,20,000 | 5 ₹26,000 Lowest | 30 ₹1,56,000 | 60 ₹3,12,000 | 50 ₹2,60,000 | 25 ₹1,30,000 |
| 2.00 | Supplying, laying, jointing testing and connecting of size 300 sqmm 3 core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches, including jointing & testing complete all as specified and directed. | 5,200 | RM | 2,320 ₹1,20,64,000 | 1,999 ₹1,03,94,800 Lowest | 2,239 ₹1,16,42,800 | 2,150 ₹1,11,80,000 | 2,281 ₹1,18,61,200 | 2,149 ₹1,11,74,800 |
| 3.00 | Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and n.exc 10 sqm on plan for foundations , laying of LT under ground cables/ GI pipes and steel tubular poles etc. and getting out in soft & loose soil complete all as specified and directed. | 1,952 | Cum | 100 ₹1,95,200 | 150 ₹2,92,800 | 180 ₹3,51,360 | 85 ₹1,65,920 Lowest | 180 ₹3,51,360 | 125 ₹2,44,000 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep in soil complete all as specified and directed. | 1,353 | Cum | 20 ₹27,060 | 16 ₹21,648 Lowest | 40 ₹54,120 | 20 ₹27,060 | 120 ₹1,62,360 | 20 ₹27,060 |
| 5.00 | Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 599 | Cum | 20 ₹11,980 | 16 ₹9,584 Lowest | 40 ₹23,960 | 25 ₹14,975 | 120 ₹71,880 | 20 ₹11,980 |
| 6.00 | Supplying & Laying un-reinforced precast concrete cable cover, Class HVP , type 1 with peak size 300 mm x 180 mm x 40 mm complete all as specified and directed. | 16,066 | Each | 20 ₹3,21,320 | 20 ₹3,21,320 | 16 ₹2,57,056 Lowest | 21 ₹3,37,386 | 33 ₹5,30,178 | 17 ₹2,73,122 |
| 7.00 | Laying only, old HT cable cover obtained from excavation complete all as specified and directed. | 10,711 | Each | 1 ₹10,711 | 0.5 ₹5,355.5 | 1 ₹10,711 | 1 ₹10,711 | 1 ₹10,711 | 0.15 ₹1,606.65 Lowest |
| 8.00 | M&L for sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed. | 390 | Cum | 300 ₹1,17,000 | 600 ₹2,34,000 | 400 ₹1,56,000 | 350 ₹1,36,500 | 600 ₹2,34,000 | 289 ₹1,12,710 Lowest |
| 9.00 | Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed. | 8 | Each | 5,500 ₹44,000 Lowest | 12,000 ₹96,000 | 12,000 ₹96,000 | 9,000 ₹72,000 | 17,498 ₹1,39,984 | 9,900 ₹79,200 |
| 10.00 | Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed. | 4 | Each | 2,000 ₹8,000 Lowest | 2,500 ₹10,000 | 9,000 ₹36,000 | 3,000 ₹12,000 | 9,202 ₹36,808 | 3,500 ₹14,000 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
17 Aug 2026, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
Q CWE (U) Delhi Cantt-110010
SPECIAL REPAIR REPLACEMENT OF 11 KV HT XLPE CABLE FROM KHYBER GRID TO DK PART 1 AND CONNECTED ITEMS UNDER GE (U) E/S DELHI CANTT-10
2026_MES_780057_1
CWE(U)/D-02/2026-27
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt-110010
As per tender documents
9 documents required · 9 mandatory
₹1,000
GE (U) Elect Supply
₹2.2 L
Yes
5 Oct 2026
22 Jul 2026
24 Aug 2026
22 Jul 2026
17 Aug 2026
12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out old existing 11 KV UG Cable of size 300 sqmm 3 core at site from trenches complete all as specified and directed. | 5,200 | RM | - | - |
| 2 | Supplying, laying, jointing testing and connecting of size 300 sqmm 3 core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches, including jointing & testing complete all as specified and directed. | 5,200 | RM | - | - |
| 3 | Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and n.exc 10 sqm on plan for foundations , laying of LT under ground cables/ GI pipes and steel tubular poles etc. and getting out in soft & loose soil complete all as specified and directed. | 1,952 | Cum | - | - |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep in soil complete all as specified and directed. | 1,353 | Cum | - | - |
| 5 | Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 599 | Cum | - | - |
| 6 | Supplying & Laying un-reinforced precast concrete cable cover, Class HVP , type 1 with peak size 300 mm x 180 mm x 40 mm complete all as specified and directed. | 16,066 | Each | - | - |
| 7 | Laying only, old HT cable cover obtained from excavation complete all as specified and directed. | 10,711 | Each | - | - |
| 8 | M&L for sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed. | 390 | Cum | - | - |
| 9 | Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed. | 8 | Each | - | - |
| 10 | Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed. | 4 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_873750.xls
BOQ • 1.14 MB
D02TP.pdf
Tender Documents • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .