EE ETD Banda
220 KV Substation Tindwari road Banda
Electrical Work
2021_UPTCL_559711_1
T-83/ETDB/2020-21
Open Tender
Electrical Works
Lump-sum
90 days
Banda
Having experience to do similar work in UPPTCL
2 documents required · 2 mandatory
₹236
EE ETD Banda
₹4,000
4 Mar 2021
26 Feb 2021
4 Mar 2021
26 Feb 2021
3 Mar 2021
26 Feb 2021
26 Feb 2021 - 3 Mar 2021
Amount
Details of Work.
Erection of main and auxillary Structure consisting of columns, beams, peaks, masts etc. and auxillary structure required for installation of isolators, CTs, PTs, CVTs, LAs and all other equipment. The job consists of shifting of all matching structure parts, nuts-bolts, washers etc. from store to site of erection of sturucture as per relevant drawings and practices using spring washer with each bolt , cutting, matching of members if required to be done by contractor without any extra cost , as to complete the work satisfactory. All material to be erected shall be supplied by UPPTCL, free of cost T&P rquired for satisfactory completion of work shall be arranged by the contractorat his own cost.
Erection of following equipments, as per instruction mannual of various equipments and technical specification including shifting of material/equipments from store to erection site including all other associated work to complete the job satisfactorily.
36KV Series Reactor
36KV NCT
C&R Panel
36KV VCB
33 KV CT JUNCTION BOX
36 KV BUS / LINE ISOLATOR
Jumpering of capacitor bank and equipment by panther conductor, including cutting laying, fixing and other associated work to complete the job satisfactorily.
Delta Earthing of Circuit Breaker and capacitor Bank (used with proper core and salt) piercing of 03 Nos. 03 mtr of 40 mm dia M.S rod inside the earth for each delta and inter connected of three electrodes with 75x10 mm M.S flats by proper welding.
Laying of following sizes of cables in Trenches from control relay panel to various equipments/marshalling boxes/JB etc. in switchyard as per cable schedule. Its saddling at every 750 mm. distance with M.S. saddles of size 25x3 mm. size including carriage of cable drums from store to laying site and shifting back to store and all other assocatied works to complete the Job satisfactorily as per technical specification.
2Cx2.5 Sq.mm
4Cx2.5 Sq.mm
6Cx2.5 Sq.mm
Termination of all size cables including making necessary holes in gland plates or box where above required fixing of cable glands of approximate size and feeruling and other associated work to complete the job satisfactorily for capisitor bank.
2Cx2.5 Sq.mm
4Cx2.5 Sq.mm
6Cx2.5 Sq.mm
Cutting stergthening, bending laying 1500mm below side ground land of following size of MS flat for earting of main and auxiliary structure and its material etc. including cutting, bending, measuring, welding and other associated work to complete the job satisfacorily.
25x6 mm MS Flat
50x6 mm MS Flat
75x6 mm MS Flat
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
M/S V.K.T. SYSTEMS
V K BACKUP SOLUTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .