Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 CrAccepted-AOC BEHIND HERO HONDA SHOWROOM DUDHANI BHAGALPUR ROAD DUMKA | DUMKA | JHARKHAND | 814101 | ₹17.4 Cr | L1 | Accepted-AOC L1 Letter No. 2914(S)WE Date-12.06.2023 |
| 2 | L2₹17.5 CrRejected-Finance GILANPARA DUMKA | DUMKA | JHARKHAND | 814101 | ₹17.5 Cr | L2 | Rejected-Finance L2 Letter No. 2914(S)WE Date-12.06.2023 |
| 3 | L3₹17.8 CrRejected-Finance 40 107 RAMKRISHNA SAMITY BUILDING 3RD FLOOR PANITANKI MORE SEVOKE ROAD SILIGURI DARJEELING W B | DARJEELING | WEST BENGAL | 734001 | ₹17.8 Cr | L3 | Rejected-Finance L3 Letter No. 2914(S)WE Date-12.06.2023 |
| 4 | L4₹20.5 CrRejected-Finance | ₹20.5 Cr | L4 | Rejected-Finance L4 Letter No. 2914(S)WE Date-12.06.2023 |
| 5 | L5₹20.5 CrRejected-Finance 23 SAHID SURYA SEN ROAD BERHAMPORE MURSHIDABAD W B | MURSHIDABAD | WEST BENGAL | 700023 | ₹20.5 Cr | L5 | Rejected-Finance L5 Letter No. 2914(S)WE Date-12.06.2023 |
Tender Value
₹19.5 Cr
EMD Value
₹19.5 L
Closing Date
1 May 2023, 12:00 pmClosed
EXECUTIVE ENGINEER RCD ROAD DIVISION DUMKA
EXECUTIVE ENGINEER RCD ROAD DIVISION DUMKA
Improvement of Riding Quality/Strengthening Work in (a) Shriamra to Golpur Road and Link Road of SKMU (L-11.2 Km) and (b) Dondia (Dumka-Sahebganj Road) to Gujisimal (Dumka-Rampurhat Road) (L-17.365 Km) (Total length-28.565 km) for the year 2022-23.
2023_CECOM_69472_1
RCD/DUMKA/642
Open Tender
Civil Works
DUMKA
AS PER SBD
3 documents required · 3 mandatory
₹10,000
EXECUTIVE ENGINEER RCD ROAD DIVISION DUMKA
₹19.5 L
16 Jun 2023
17 Apr 2023
3 May 2023
17 Apr 2023
1 May 2023
17 Apr 2023
Amount
Clearing and Grubbing Road Land .(Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) RCD SOR - 2.3 I (A)
dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000m stacking serviceable and unserviceable material separetaly RCD SOR - 2.5(II)A
Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. RCD SOR - 4.14B
Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. RCD SOR - 4.14B
Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means. RCD SOR - 5.01A (i)
Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means. RCD SOR - 5.01A (i)
Tack Coat on Bituminous surfaces Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. RCD SOR - 5.02 (i)
Tack Coat on Bituminous surfaces Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. RCD SOR - 5.02 (i)
Dense graded Bituminous Macadam Grading-II With VG-30 Bulk Bitumen Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects with VG-30 Bulk Bitumen. RCD SOR - 5.04A
Dense graded Bituminous Macadam Grading-II With VG-30 Bulk Bitumen Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects with VG-30 Bulk Bitumen. RCD SOR - 5.04A
Bituminous concrete Grading- II With VG-30 Bulk Bitumen Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects with VG-30 Bulk Bitumen. RCD SOR - 5.05(A)(B)
Bituminous concrete Grading- II With VG-30 Bulk Bitumen Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects with VG-30 Bulk Bitumen. RCD SOR - 5.05(A)(B)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) RCD SOR - 8.13
Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode.The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280.The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinkikng in 1 Hz.There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhace the life of the marker and a full charge should provide for a minimum autonomy of 50 hours.The height, width and length of the marker shall not be less than 10mmx100mmx100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively.The weight of the marker shall not exceed 0.5 Kilograms.Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.) RCD SOR - 8.35
Road Delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.) RCD SOR - 8.15
Construction of Subgrade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2. RCD SOR - 3.18
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) 5th kilometre stone (precast) RCD SOR - 8.14(i)
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary kilometer stone (precast) RCD SOR - 8.14(ii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. (I)90 cm equilateral triangle RCD SOR - 8.04 A (ii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60 cm circular RCD SOR - 8.04 A (viii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 80 mm x 60 mm rectangular RCD SOR - 8.04 A (x)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 90 cm high octagon RCD SOR - 8.04 A (xv)
Direction and Place Identification Signs upto 0.9 sqm Size Board.(Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) RCD SOR - 8.05
Direction and Place Identification Signs with size more than 0.9 sqm size Board.(Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2mm thickness and 4.5m meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) RCD SOR - 8.06
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) RCD SOR - 8.08
Overhead Signs (Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per IRC: 67) Truss and Vertical Support RCD SOR - 8.07A
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.RCC Grade M20,RCC Grade M20 using batching plant, transit mixture & Concrete pump RCD SOR - 12.8C
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.RCC Grade M20,RCC Grade M20 using batching plant, transit mixture & Concrete pump RCD SOR - 12.8C
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. RCD SOR - 12.42
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. RCD SOR - 12.42
Fixing of reflective sheeting including all cost of materials and fitting charge complete works as per specification and direction of E/I. RCD SOR - NS
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Mechanical Means Depth upto 3 m RCD SOR - 12.01 B(i)
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.PCC Grade M15 PCC Grade M15 using batching plant & Concrete pump RCD SOR - 12.08(A) Case-1
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.PCC Grade M15 PCC Grade M15 using batching plant & Concrete pump RCD SOR - 12.08(A) Case-1
Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications.Random Rubble masonry (coursed/uncoursed) RCD SOR - 12.07(B)
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications, Random Rubble Masonry (Coursed/uncoursed) RCD SOR - 13.04(A)
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications, PCC Grade M20Height upto 5m, PCC Grade M20 using batching plant, transit mixer & concrete pump RCD SOR - 13.05(B)(p)
Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification. RCD SOR - 13.1
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications, RCC Grade M20, Height upto 5m,RCC Grade M20 using batching plant, transit mixer & concrete pump RCD SOR - 13.05E(p)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification,RCC Grade M30 Using Batching Plant,Transite Mixer and Concrete Pump.For solid slab super-structure, 20-30 per cent of (a+b+c) RCD SOR - 14.01C
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications RCD SOR - 13.06
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications RCD SOR - 14.2
Add 18 % GST (in Basic Rate must fill 18)
Add 1% Labour Cess (in Basic Rate must fill 1)
M/s CHITRA CONSTRUCTION
KAMAC ENGINEERS PRIVATE LTD
M/s Ganesh Yadav
Ms Mohan Lal Jain
M/s S.K. Tekriwal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid