| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC 316 A VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹38.1 L+₹5.5 L (16.9%)Rejected-Finance MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Highest amount quoted | |
| 3 | Rejected-Technical 738 3 VFJ ROAD RAMNAGAR RANJHI JABALPUR 482009 M P | JABALPUR | MADHYA PRADESH | 482009 | - | Rejected-Technical Not fulfilled the criteria of requisite class |
Tender Value
₹38.9 L
EMD Value
₹78,000
Closing Date
25 Nov 2023, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
SPL REPAIR OF DRAINAGE SURROUNDING THE BLDG NO T1 AND T2 AT 506 ABW AND PROVN OF CATTLE CHAIN LINK FENCING IN BLDG NO TSM 1 ZONE B AT COD UNDER AGE BR-II OF GE (EAST) JABALPUR
2023_MES_622829_1
8582/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹78,000
Yes
20 Jan 2024
27 Oct 2023
27 Nov 2023
27 Oct 2023
25 Nov 2023
11 Nov 2023
27 Oct 2023 - 3 Nov 2023
Amount
Excavating over areas, n.exc 1.5m deep and getting out etting out any type of soil complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10sqm on plan and n.exc 1.5m in depth and getting out in any type of soild complete all as specified and directed.
Excavating in post holes (or similar holes) in any type of soild each n.exc 0.5cum, gettingn out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and maing good surface complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (unreinfored) in gound floor n.exc 15cm thick complete all as specified and directed.
Taking down cement plaster of any description on wall and ceiling in patches incl taking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Hardcore broken stone of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundatios, filling and mass-concrete complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate in walls or retaining walls, any thickness, size pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate in walls or retaining walls, any thickness, size pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for RCC design mix M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC design mix M-25 as in walls, retaining walls, basement walls and the like, any thickness, above top of footings, including attached plasters and buttresses complete all as specified and directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M&L for use and waste of formwork to face of walls, retaiing walls, abutment, parapets and staircase railing and similar work including attached pillaters, buttresses etc vertical or to batter complete all as specified and directed.
TMT HYSD mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
TMT HYSD mild steel bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply only chain link MS fencing of any size or type complete all as specified and directed.
Fixing only chain link fencing of mesh size 75 x 75mm including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cutting tips to shape as sirected, drilling, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reveting, welding etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
S&F mild steel bolt maching made with hexagonal or seuare heads at one end and screwed the other or screwed bot ends each screwed and to be fitted with washers and one hexagonal or square but length of bolt exc 5cm but n.exc 10cm long dia shall be of 5 to 10mm dia complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete or shape complete all as specified and directed.
M&L for precast cement concrete block soild blocks PCC 1:2:4 type B-1 using 20 mm aggregated masonry with exc 10 cm in width and setting in CM 1:4 complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded crushed stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 20 mm graded crushed stone aggregate cement concrete in surface channels and drains complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 450mm complete all as specified and directed.
Supply, laying and joint 450mm nominal dia HDPE double stone wall corrugated pipe as drain lintel other similar work in trenchless excavation to roads, path etc, in any type of soil without disturbing top surface by means complete all sepcified and directed.
M&L for cement concrete 1:4:8 type D-2 450 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
S&F reinfored concrete pipes, 450mm bore class NP-2 laid jointed complete with collars complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20 mm graded crshed stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. Note : (i) Curing tank should be construeted 4 x 4 x 0.9m at site. (ii) Steel from work must be used for casting. (iii) PCC platefrom shall be construction at site. (iv) Mild steel plate surrouding each cover slab. It shall paid separately and TMT Bar shall be paid separately.
Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed.
M&L for preparing new steel surfaces of any description, over 10cm width or girth and applying two coats with synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying two coats of cement base paint over a coate of primer white or tinted complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
Fixing only machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size confirming to IS-15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
Schedule of credit amount of Rs. 38,940.00 to be deducted during AOC.
M/S BHATIA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .