Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.7 L+₹1.8 L (7.01%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹27.7 L+₹1.8 L (7.05%)Rejected-Finance NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹34.0 L+₹8.1 L (31.1%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹35.6 L+₹9.7 L (37.6%)Rejected-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
10 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIRS MAINT OF EXTERNAL WATER SUPPLY PIPE LINES PIPE LINE AT SEWAGE INSTALLATION AND ALL TYPE OF VALVES AND VALVE PIT PUMP SETS AND STARTERS WITH ALLIED WORKS CHLORINATION RO PLANTS WITH SUPPLY OF WATER TREATMENT CHEMICALS IN MAIN CAMP AND TECH AR
2024_MES_674169_1
GE(AF)/TBM/8766/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹68,000
Yes
6 Nov 2024
12 Sept 2024
12 Oct 2024
12 Sept 2024
10 Oct 2024
26 Sept 2024
Amount
M&L for attending water supply complaints of any type , finding of fault/ defect and repairing the same including required jointing materials and making water supply functional complete all as specified and as directed. Note:- Quoted rate shall be inclusive for following provisions:- (i) Contractor shall deploy one plumber and one helper for collect the complaints from MES complaint cell as and when intimated by JE/Engineer-in-Charge. (ii) Tools,minor spares such as washer,nuts,white lead etc as required for rectifying complaints. (iii) Contractor shall submit the details of rectification /non retification of complaints to JE/Engineer-in-Charge after attending complaint.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 metre depth and getting out in hard/dense soil for taking out / laying of GI pipe complete all as specified and as directed.
Returning and filling including spreading, leveling, watering and well remming in layer n.exc 25 mm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance n..exc 50 m and depositing where directed at a level n..exc 1.5 m above the starting point all as specified and directed.
M & L for taking up or down from trenches old CI/GI Pipe including fittings and branch connections if any for cleaning and refixing or removal to stores for further disposal of complete all as specified and directed for the following sizes:-
300 mm dia
200mm dia
150mm dia
100mm dia
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
M & L for Re-fixing old serviceable steel tubing obtained from Item No 5 and connections in new or old position of size in walls, ceiling, floors, / trenches complete all as specified and directed for the following sizes:-
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply and lay GI pipe of medium grade including fittings such as bends, reducer, elbows, union etc in trenches complete all as specified and directed for the following sizes :-
100 mm dia
80mm dia
50mm dia
40mm dia
25mm dia .
20mm dia
15mm dia
Supply and lay GI pipe of medium grade including fittings such as bends, reducer, elbows, union, clips, wall hooks, wooden plugs etc in wall/floor/sump/wells. including cutting through wall/floor/sump/wells and making good the distrubed surfaces to match with existing complete all as specified and directed for the following sizes :-
100 mm dia
80mm dia
50mm dia
40mm dia
25mm dia .
20mm dia
15mm dia
Supply and laying in trenches of Ductile Iron spigot and socket pipes as per IS:8329/2000 Class K7 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside Zinc bitumen coating complete all as specified and directed for the following sizes :- Make :- Electrosteel/Tata /Jindal
300mm dia
200mm dia
150mm dia
100mm dia
80mm dia
M & L cast iron fittings ISI marked such as bends (any type, radius any angle) tapers any type (straight or bend), increasing, decreasing or double socket etc) Tee pieces single branch, double branch,cross(all sockets and socket and spigot) collars, caps and plugs tail piece confirming to IS 1538/1993 complete all as specified and directed.
M & L run lead joint including all necessory jointing materials like lead spunyarn etc (old recovered lead from leaking joints shall not be re used) for the CI pipe complete all as specified and directed for the following sizes :-
300 mm dia
200mm dia
150mm dia
100mm dia
80mm dia
Supply and fix in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed for the following sizes:- Make:- Leader/Zoloto/Vir
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply and fix in repairs CI Non Return valve conforming to IS-5312 Part - I ,PN 1.6 ,having flanged end joints with brass seating including jointing materials such as 3mm rubber gasket 01 No, 10mm dia nut & bolts and washers complete all as directed for the following sizes :-. Make :- Kirloskar/Upadhaya/Leader/ Kartar
150mm dia
100mm dia
80mm dia
Supply and fix Gun metal Non Return Sluice Valve of size 50mm bore ISI marked suitable for screwing in GI pipes fixed all as specified and as directed.
Supply and fixing in replacement CI sluice valve confirming to IS -14846 PN-1.0 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers and 3mm rubber gasket 02 Nos complete all as specified and directed for the following sizes:- Make :- Kirloskar/Leader/Kartar
300 mm dia
150mm dia
100mm dia
80mm dia
Cutting of existing road/ floor/ plinth/drain of any description of width and depth not exeeding 0.45 metre for taking out /laying of CI/DI/GI pipe line including necessary earth work excavation and making good the distrubed surface with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified.
Supply and fix in repair galvanised iron bolt,nut and washers of any dia and length as required at site all as specified and as directed.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in foundation for valve chamber etc all as specified and as directed.
Brick work with sub class "B" bricks using old size bricks straight or curved on plan exc 6m mean radius,built in cement mortor 1:6 as in valve chamber complete all as specified and as directed.
Rendering 10mm thick on fair faces of bricks(inside of valve chamber) in cement mortor 1:4 finished the surface even and smooth without using extra cement,complete all as specified and as directed.
Mild steel chamber cover made with mild steel sheet of 3.15mm thick for shutter angle iron frame including necessory welding and fixing arrangement and applying two coats of synthetic enamel paint over a coat of metal primer etc complete including taking down old MS sheet cover all as specified and as directed..
Surface dressing n.exc 15 cm deep and getting out in hard /dense soil around shallow well / pump houses inside the fencing and outside 3 m wide around the edges of fencing all as specified and directed.
S&F in repair 12mm dia nylon rope or suitable size to match with existing for hanging pumpsets/motors in well/sumps etc., complete all as specified and directed.
Supply only grafted cotton rope (gland packing rope ) complete all as specified and directed for thef following sizes:-
6 mm dia
8 mm dia
10 mm dia
12 mm dia
M&L required for attending pump set /motor complaints of any type , finding of fault/ defect and repairing the same including required repairing materials and making pump sets/motor functional complete all as specified and directed. Note :- Quoted rate shall be inclusive for following provisions:- (i) Contractor shall deploy one MotorMechanic and one helper for collect the complaints from MES complaint cell as and when intimated by JE/Engineer-in-Charge. (ii) Tools,minor spares such as washer,nuts,white lead etc as required for rectifying complaints. (iii) Contractor shall submit the details of rectification /non retification of complaints to JE/Engineer-in-Charge after attending complaint.
Repairing centrifugal pump set by replacing of the relevant spares taken and including packing, refixing and testing of motor of capacity 40 HP complete etc., all as specified and as directed. Note: Spare parts/ accessories like shaft, bush, bearings, gland etc., shall be measured and paid separately under relevant items of this schedule.Location: MES Complex P/H.Make:- Kirloskar
Supply only the following spares suitable for 40 HP capacity centrifugal pump set :-
Impeller
Pump Shaft
Shaft Sleeve
Bearing
Gland coller complete with nut and bolts
Repairing centrifugal pump set by replacing of the relevant spares taken and including packing, refixing and testing of motor of capacity 25 HP complete etc., all as specified and as directed.Note: Spare parts/ accessories like shaft, bush, bearings, gland etc., shall be measured and paid separately under relevant items of this schedule.Location : C Tank P/ H Make : Kirloskar
Supply only the following spares suitable for 25/20 HP capacity centrifugal pump set:-
Impeller
Pump Shaft
Shaft Sleeve
Bearing
Gland coller complete with nut and bolts
M&L for repairing centrifugal split type/monoblock pump set by replacing of the relevant spares taken and including packing, refixing and testing of motor of capacity 15 HP complete etc., all as specified and directed. Note: Spare parts/ accessories like shaft, bush, bearings, gland etc., shall be measured and paid separately under relevant items of this schedule.Location : One Lakh Gallon P/H Make : Kirloskar
Supply only the following spares suitable for 15 HP capacity centrifugal split type/monoblock pump set
Impeller
Pump Shaft
Shaft Sleeve
Bearing
Gland coller complete with nut and bolts
M&L for repairing centrifugal pump set by replacing of the relevant spares taken and including packing, refixing and testing of motor of capacity 7.5/5 HP complete etc., all as specified and directed Note: Spare parts/ accessories like shaft, bush, bearings, gland etc., shall be measured and paid separately under relevant items of this schedule.Location : One Lakh Gallon P/H,C tank P/H Make : Kirloskar
Supply only the following spares suitable for 7.5/5 HP capacity monoblock pump set
Impeller
Pump Shaft
Shaft Sleeve
Bearing
Gland coller complete with nut and bolts
M&L for repairing centrifugal non clog sewage pump set by replacing of the relevant spares taken including packing, refixing and testing of motor of capacity 12.5 HP complete etc., all as specified and directed.Note: Spare parts/ accessories like shaft, rubber flap, bearings, gland packing, rubber packing and sleeve etc., shall be measured and paid separately under relevant items of this schedule.Location : Main Camp sewage P/H Make : Kirloskar
Supply only the following spares of 12.5 HP capacity centrifugal non clog sewage pump set
Impeller
Rubber Flap
Pump Shaft
Rubber flap
Ball bearings
Gland coller complete with nut and bolts
Rubber packing
Shaft Sleeve
Taking out the submersible pump set/ monoblock submersible pump sets from its position and carrying out repairs after proper cleaning of impellers & shafts, including packing, refixing in position and testing of motor of capacity 2/3 HP complete etc., all as specified and directed.(Make:- Kirloskar ) .Note: Spare parts/ accessories like impeller, shaft, bush and sleeve etc., shall be measured and paid separately under relevant items of this schedule.Location : MES Complex P/H
Supply only the following spares of 2/3 HP capacity submersible pump set/ monoblock submersible pump set
Impeller
Pump Shaft
Bearing
Shaft Sleeve
M&L for taking out the submersible pump set/ monoblock submersible pump sets from its position and carrying out repairs after proper cleaning of impellers & shafts, including packing, refixing in position and testing of motor of capacity 5/7.5 HP complete etc., all as specified and directed.(Make:- Kirloskar ) Location: Camp Shallow wells Note: Spare parts/ accessories like impeller, shaft, bush and sleeve etc., shall be measured and paid separately under relevant items of this schedule.
Supply only the following spares of 5/7.5 HP capacity submersible pump set/ monoblock submersible pump set
Impeller with bowl
Pump Shaft
Shaft sleeve
Taking out the submersible pump set/ monoblock submersible pump sets from its position and carrying out repairs after proper cleaning of impellers & shafts, including packing, refixing in position and testing of motor of capacity 10 HP complete etc., all as specified and directed.(Make:- Kirloskar ) Location: Camp Shallow wells. Note: Spare parts/ accessories like impeller, shaft, bush and sleeve etc., shall be measured and paid separately under relevant items of this schedule.
Supply only the following spares suitable for 10 HP capacity submersible pump set/ monoblock submersible pump sets
Impeller with bowl
Pump Shaft
Shaft sleeve
M&L for stripping out squirrel cage, induction motor, 3 phase 415 volts AC 50 c/s starter and rotor cleaning up internally and externally including removing old burnt copper wire, worn out bearing and rewiring/ rewinding with new copper wire, including necessary transportation workshop and bring back to the installation and assembling, testing and commissioning of motor complete etc., all as specified and directed for the following capacity .Location : Camp Pump Houses
40 HP capacity
20/25 HP capacity
15 HP capacity
Taking up defective submersible pump set/ Monoblock submersible pump sets 3 phase,AC,415 volts, 50 c/s from shallow well and disconnecting cable, GI delivery pipe etc,taking out/transport to work shop, dismantling and rewinding submersible pump motor with appropriate size of copper wire , reassembling,erecting back in position, cable jointing, testing and commissioning of motor complete all as specified and directed for the following capacity:-( Location: Camp Shallow wells )
2/3 HP capacity
5 HP capacity
7.5 HP capacity
10 HP capacity
Taking up unserviceable centrifugal non clog submerciable sewage pump set 25HP from sewage sump by bail out the water, disconnectin ,declamping, transport to authorised work shop and re-installation in the sump,after repaired,testing complete including replacement of accessories like Gasket,cable protector kit,terminal block with terminal plate,'O' rings,seal monitors,safety rings,cable end cap,Painting etc as required complete and service charges complete all as directed. (Make:- KSB ) Location : Main Camp sewage pump House . Note: Replacement of Winding,insulating oil, bearings,Seal, Sensor,Shaft etc., shall be measured and paid separately under relevant items of this schedule.
Supply only the following spares of centrifugal non clog submerciable sewage pump set 25HP capacity:-
Re-winding stator with with new copper wire of appropriate size of class-F insulation and including removing old burnt copper wire
Replacement of bearing (Top,bottom & RR)
Replacement of mechanical seal lower and upper
Temperature Sensor
Moisture sensor
Rotor Shaft
Repalcement Insulating oil as per the manufacturer recommended grade
Taking up unserviceable centrifugal non clog submerciable sewage pump set 12.5HP from sewage sump by bail out the water, disconnecting ,declamping, transport to authorised work shop as directed by Engineer-in- charge and re-installation in the sump,testing complete including replacement of Gasket,cable end cap, water/oil Seal,oil, painting and service charges etc.,lathe work as required complete and testing all as directed. (Make:-Kishore ) Location : Main Camp sewage pump House . Note: Spare parts/ accessories like Winding charges,bearings, Seal,Sensors,Shaft etc., shall be measured and paid separately under relevant items of this schedule.
Supply only the following spares of centrifugal non clog submerciable sewage pump set12.5HP capacity
Re-winding stator with with new copper wire of appropriate size of class-F insulation and including removing old burnt copper wire
Bearing upper and lower.
M-seal lower and upper
Temperature Sensor
Moisture sensor
Rotor Shaft
O Ring
Repalcement Insulating oil as per the manufacturer recommended grade
S&F contactor for Star Delta starter 440 volts, 50 Hz, 3 phase, AC, suitable for following HP of induction motors all as specified and directed.
upto16 Amps suitable for 7.5 / 10 HP
upto 25 Amps suitable for 12.5/15 HP
upto 80 Amps suitable for 25/ 40 HP
Supply and fix DOL starter suitable for submersible pump 3 phase AC motor upto 5HP,3Phase,415 volt all as specified and as directed..Make : L&T / BCH/ SIEMENS
Supply and fix automatic star delta starter suitable for pump set, 3 phase AC motor capacity 7.5 to 15HP,built in overload relay,single phase preventor,AC3,4pole contactor,415 volt in heavy duty deep drawn sheet metal box all as specified and as directed. Make : L&T / BCH/ SIEMENS
Supply and fix electronic overload relay suitable for submersible pump as specified and directed.
S&F No volt coil, 440 volt ,suitable for star delta starters up 7.5 to10 HP capacity
S&F No volt coil suitable for DOL starter up to 5 HP capacity, 440 volts.
S&F in fix single phase preventer Make: Minilec
Supply and fix in repairs MCB TPN, capacity 40/63 Amps, 10 KA suitable for LT panel board including dismantling existing unserviceable MCB complete all as specied and directed.
Supply and fix following capacity of MCCB TPN , 415 volt,fixed in repair on existing panel board including dismantling existing unserviceable MCCB complete all as specied and directed.
63 Amp ,25 KA
100 Amp.25 KA
Taking out defective flat PVC insulated, submersible cable,3 core, 4 Sqmm multistrand copper cable from submersible pump set including supply and providing new cable of same size, jointing with jointing materials, testing and commissioning etc., complete all as specified.
Repair to existing pump houses LT panel board by replacing following unserviceable items all as specified and directed.:-
Voltmeter (squar type) of size 96 x 96mm, 0-500 V, AC, 50 c/s
Ammeter CT operated of size 96 x 96 mm, 0-100 V, AC, 50 c/s
Current transformer of ratio 100 / 5 Amps, VA burden - 15, 415 volts
Current transformer of ratio 60 / 5 Amps, VA burden - 15, 415 volts
Indication lamp Red/ Yellow/ Blue with base including dismantling of unserviceable old items complete.
Preparing surface of 3 phase ,415 volts,50 c/s pump sets of following capacity and painting with two coats of synthetic enamel paint all as specified and directed.
40 HP capacity
25 HP capacity
15 HP capacity
12.5 HP capacity
7.5 HP capacity
5 HP capacity
Preparing surface of Pump sets panel board of following pump houses and painting with two coats of synthetic enamel paint including marking on sticker letters for all panel eqipments details etc all as specified and directed.
MES Complex P/H
C tank P/H
One Lakh P/H
28 Class room P/H
Golden Jublee P/H
Camp area shallow wells
Camp sewage P/H
M&L for Fabrication,install,commissioning and testing of LT cubical motor starter panel board of size not lessthan 1.8 (H)x1.2(L)x0.45(B) mtr, three phase 4-wire systems,Indoor type, dust and vermin proof, made out of CRCA sheet 3.0 mm thickness, powder coated, double door,with locking arrangements,mounted on ISMC 75 on PCC plate form including control wiring complete , necessary PCC 1:3:6 staging for panel etc including taking down existing unserviceable panel complete at all as directed to suitable to accommodate the following:-(Location: No 4 Shallow well pump house) (a) MCCB 100 Amps, 10 KA, 4 pole, 415 volts with thermal based release - 01No (incoming) (b) MCB 32 Amps,TPN pole,415 volts - 04 Nos.(for starters) (c) Multi functional digital meter for voltage, ampere, frequency etc,3phase,4 wire system with CTs - 01 Set (d) Indicating lamps LED type R,Y,B and main ON,over load trip etc.-06 Nos (e) Copper bus bar of capacity 200 Amps size 40 x 3 mm -04 Nos (f) Star delta starter for centrifugal mono block pumpset (7.5 hp) upto 32Amps rating.-04 Nos (g) Single phase preventor -04 Each (h) Over load relay -04 Each (j) Timer set -04 Each (k) Push button and rear connections for ON/OFF -04 Each
M&L for Fabrication,install,commissioning and testing of LT cubical motor starter panel board of size not lessthan 1.0x0.75x0.30mtr, three phase 4-wire systems,out door type, dust and vermin proof, made out of CRCA sheet 3.0 mm thickness, powder coated, double door,with locking arrangements,mounted on ISMC 75 on PCC plate form including control wiring complete , necessary PCC 1:3:6 staging for panel etc including taking down existing unserviceable panel complete all as directed to suitable to accommodate the following:- ( Locations:- Old Bomb Dump Shallow well) (a) MCCB 63 Amps, 10 KA, 4 pole, 415 volts with thermal based release - 01No (incoming) (b) MCB 32 Amps,TPN pole,415 volts - 02 Nos.(for starters) (c) Multi functional digital meter for voltage, ampere, frequency etc,3phase,4 wire system with CTs - 01 Set (d) Indicating lamps LED type R,Y,B and main ON,over load trip etc.-06 Nos (e) Copper bus bar of capacity 200 Amps size 40 x 3 mm -04 Nos (f) Star delta starter for submersible pumps upto 32Amps rating.-02 set (g) Single phase preventor -02 Each (h) Over load relay -02 Each (j) Timer set -02 Each (k) Push button and rear connections for ON/OFF -02 Each
M &L for wiring for circuit /sub main wiring along with earth wire with the following sizes of HRFR, PVC insulated unsheathed ,industrial grade copper conductor ,single core ,flexible cables,1100 volts conforming to IS-694 drawn in existing cable ducts /racke/pipes in surface /recessed as required for connections from panel to pump motors including taking down /dismantling of existing unserviceable /burnt copper conductora all as specified and as directed .
M/L for earthing for pole complete with galvanized steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead strip 32 X 6 mm as earth lead by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 5 of SSR Pt I (2009). The quoted rate is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed
M&L for Earth continuity conductor or main earthing fixed to wallon batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to plant /machinery or any other indicated situation for loop earthing as required 32 x 6 mm galvanised iron strip
Supply only orthotolidine solution 500ML for testing chlorine content all as specified and directed
Supply only chlorine test kit for testing chlorine content all as specified and directed
M&L for replacement of chemical dosing pumps, single phase 230 volts, 50Hz with connecting wire for plant to pumping the solution complete all as specified and directed
Supply and top up chemicals such as sodium mete bisulphate, sodium hypo chloride, antiscallant and PH correction complete as required level for entire contract period all as specified and directed
Material and labour for changing and washing of activated carbon media and replacement of new sand including testing of RO plant water complete all as specified and directed
Supply and replacement of cartridges for the RO plant to filtering the water inside the plant water chamber complete all as specified and directed
M&L for Replacement of Membrane,spiral wound type,MOC:poly Amide, size 8" dia,1000mm long,complete and testing of 5000 LPH RO Plant at Near Chauhan mess all as specified and directed. Make:LANXESS/SUEZ or equivlent as approved.
M&L for monthly servicing(Every month) and testing of 5000 LPH RO Plant all as specified and directed.(for RO plant two Nos at Golden jubilee and Near chauhan mess.) Note :1. Contractor shall be submit the pre / after serviceablity test report and recommendation / suggession if any. 2. Servicing to be done by any authorised OEM service provider. 3.Service test report to be submitted by contractor .
Material and labour for stripping out squirrel cage, induction motor, 3 phase 415 volts AC 50 c/s starter and rotor cleaning up internally and externally including removing old burnt copper wire, wornout bearing and rewinding with new copper wire,Including necessary transpotation to workshop and bring back to the installation assembling testing and commissioning of motor capacity 3 / 5 HP, 3 phase, 415 volts, 50 c/s. complete all as specified and directed
Bailing out water from PVC Syntex 5000 Ltrs to 15000 Ltrs capacity tank mounted on floor/ RCC Staging for removing silt, sludge, mud, moss, efflorescent salts and algae growth etc., using steel wire brushes/ cleaning tools and washing all internal surfaces using cleaning materials like bleaching powder or other cleaning liquids and draining out the waste water completely including one coat of white washing all inside wall surfaces and roof including writing letter in bold with white paint of size not exceeding 10 cms height on black back ground with details such as OHR capacity, date of cleaning and due date of next cleaning etc all as specified and directed.
Supply and lay UPVC pipe 20mm dia heavy duty gde including fittings, for inlet and outlet connections of dosing pumps including connections with ferrules in delivery water pipe lines, fixed on wall,floor, in trench all as specified and directed
Supply and laying 3 layer PP-R polypropyline random copolymer concealed pipes of SDR 7.4 (PN-16) UV stabilised and anti-microbial fusion welded having thermal stability for water supply including all PP-R plain & brass threaded polypropyline random fittings fixed complete to laid in trenches complete all as specified including taking up or down old PPR Pipe from trenches including all fittings etc. Make : Prince / Wet Flow / SFMC / Fusion / Vectus / Reliance Note: Excavation & earthwork shall be measured and paid separately
75 mm dia
50mm dia
40 mm dia
Supply and laying 3 layer PP-R polypropyline random copolymer concealed pipes of SDR 7.4 (PN-16) UV stabilised and anti-microbial fusion welded having thermal stability for water supply including all PP-R plain & brass threaded polypropyline random fittings fixed complete to walls, ceiling or in floors complete all as specified including taking up or down old unserviceable PPR pipe from walls,ceiling /floors including all fittings etc for the following dia all as specified and directed. Make : Prince /Wet Flow / SFMC / Fusion / Vectus/ Reliance
25 mm dia
20mm dia
16 mm dia
S & F PP-R Gate valves (Brass insert) with iron wheel head screwed down iron pipe after and including taking down/up old unserviceable PPR valve complete for the following dia all as specified. Make : Prince /Wet Flow / SFMC / Fusion / Vectus / Reliance
63 mm dia
50 mm dia
32 mm dia
25 mm dia
M&L for repairing centrifugal pump set by replacing of the relevant spares taken and including packing, refixing and testing of motor of capacity 3/5 HP complete etc., all as specified and directed Note: Spare parts/ accessories like shaft, bush, bearings, gland etc., shall be measured and paid separately under relevant items of this schedule. Make : Kirloskar
Supply only the following spares suitable for 3/5 HP capacity monoblock pump set
Impeller
Pump Shaft
Shaft Sleeve
Bearing
Gland coller complete with nut and bolts
Motor cooling fan with cover
Supply only bleaching powder suitable Grade -I confirming to IS 1065/89 (Second revision ) minimum available chlorine 33.5% by mass packed in HDPE of 25 Kg capacity. Make :Any E-in-C Branch approved make
NAVEEN ENTERPRIESES (BID ID -3127342)
Sri Sankar Enterprises (BID ID -3126572)
Banyan Engineers and Contractors (BID ID -3134789)
rc enterprises (BID ID -3135076)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .