Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
8 Sept 2026, 2:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work involving supply, Installation Testing and Commissioning of CCTV surveillance system using Fixed/Bullet/dome/PTZ type camera.
10 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure- V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
1. Tenderer must understand the work before quoting. Submission of tender shall be deemed to have been done after careful study and examination of papers as well as work site and understanding of the implication thereof. 2. Quoted rates shall include all types of taxes (including GST), duties, carrying cost of all materials for the work including loading unloading involved in the concerned work. 3. All the supply materials to be deposited at the store of SSE/Tele/Store/ASN. 4. All material supplied by Railway as well as those supplied by the contractor have to be transported from the store of SSE/Tele/Store/ ASN to the site of work by the contractor's own arrangement. 5. All released materials as well as any leftover material intact will have to be transported from the site back to the office of the SSE/Tele/Store/ASN by contractor's own arrangement. 6. Any petty material which is required for execution of the work, not mentioned in this schedule as Rly. supply, contractor has to arrange for the same as per advice of Site Engineer. 7. Items supplied by the contractor will be inspected by the authorized representative of Sr. DSTE/ASN or RDSO/Rites as mentioned in schedule of work. The product (Dome camera, Bullet camera & PTZ camera) should be STQC certified under the terms & condition of the IoT system certification scheme (IoTSCS). All the cost of inspection shall be borne by the contactor. 8.Contractor have to submit indemnity bond for safe custody and protection of railway materials during transportation (sample may be collected from office) 9. Work to be done as per advice of site engineer.
10.The Contractor & his supervisors, staff must take proper precaution during working in Railway area to prevent any interference with existing Rly. system, working & passengers. 11. Care should be taken to avoid damage to existing gears during the work. Any damages to the Railway property shall be made good by the contractor in his own cost. 12. Payment shall be made as per extant works contract procedure based on actual work done. 13. Latest guideline of Railway Bd.'s vide letter no. 2018/CE-I/CT/9 dated 04.06.2018 regarding "Letter of Credit" as Mode of payment in Works Tenders or Service Tenders is attached in pdf file. 14. An Eastern Railway Guidelines (ER cable cut JPO) for protection of cables while digging work in the vicinity of underground Signalling, Electrical & Telecommunication cable (ER letter No.SG.244/13/0 DT.12.08.2024) has been finalised. Accordingly, while working near underground Signalling, Electrical & Telecommunication cable, proper care should be taken to avoid the cable cut, other wise the penalty amount as per Railway Guidelines will be recovered from the erring contractors.
Asansol Division: Provision of CCTV at DRM Office & Railway officers Colony at Asansol and Asansol Division: Requirement of CCTV Cameras in different Station/Yards.
48-SDSTE-ASN-2026-27~ER
48-SDSTE-ASN-2026-27
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹2.4 L
14 Aug 2026
14 Aug 2026
25 Aug 2026
168 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,02,167 | ||
| — | 2.00 | — | — | ||
| Supply of PLB-HDPE Duct for UG armoured Optical Fibre Cable diameter 40.0 mm, as per RDSO Specification No. RDSO/SPN/TC/45/2013 Revision 2.0 or latest, in length of 1000mtrs/roll. For each K.M. of HDPE duct pipe following items are to be supplied (a) end plugs-02nos., (b) cable sealing plugs-02nos., (c) plastic couplers slip fit/push fit type-02nos., (d) end plugs to be provided along with drum-02nos. MAKE: WESTERN/Gangotri/similar. Inspection: Consignee. | — | — | — | 1,25,734 | |
| — | 2.00 | — | — | ||
| Laying Of HDPE DUCT 40/33 mm in trenchs and protective works including pulling of single mode armoured OFC Cable( fibre) through duct in trenches as advised by site engineer. Note: (1)Contractor will take over the OFC cable from Railway store to site of work duly checked the continuity of each fiber from end to end (2) before & after cable laying of OFC cable through duct, continuity test from end to end of each fiber to be made by contractor to ensure availability of all fibers duly certified by the site enginner. | — | — | — | 49,468 | |
| — | 2.00 | — | — | ||
| Supply of Optic Fibre Cable 6 Core(Single mode) armoured, as per TEC Spec. TEC/GR/OFC-02/03.Sep.2003 or latest, Make: FINOLEX CABLES LIMITED/Usha martin/STERLITE TECHNOLOGIES LIMITED/BIRLA CABLE LIMITED/similar, Inspection: Consignee. | — | — | — | 83,296 | |
| — | 2.00 | — | — | ||
| Supply of Splice Closure for Optical Fiber Cables Armoured and Metal free type OFC With screws sealing as per as per TEC/GR/TX/OJC-002/03/APR-2010, including all miscellaneous items & consumables for fiber splicing, make: 3M/Comscope/R&M/Drone Edge/similar, Inspection: Consignee. | — | — | — | 7,116 | |
| — | 2.00 | — | — | ||
| Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | — | — | — | 13,348 | |
| — | 100.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) Two (02) nos. Of 40mm HDPE pipes & Two (02) nos. of 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. Inspection: Consignee. (as there is variable quantity of HDPE Pipe of various sizes) | — | — | — | 1,75,800 | |
| — | 100.00 | — | — | ||
| Fixing of GI Pipe of required length at all road crossing/track crossing which fall on cable route & laying of telecom cable through them & also on bridge/below mettaled road/L- Xing/culvert/track crossing for laying of cable through it. This also includes installation of all materials required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges & sudden bends. | — | — | — | 9,800 | |
| — | 5.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipment to SEEB (v) Supply of copper lug sleeve for 3/16 cable. Inspection: Consignee. | — | — | — | 75,735 | |
| — | 5.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as supplied in above item.It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 4672007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equippotential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. | — | — | — | 32,895 | |
| — | 1525.00 | — | — | ||
| Supply of CAT6 U/UTP Cable for Indoor use, 4-pair unshielded twisted pair (UTP) cable, FR PVC Jacket, High Density Polyethylene insulation, 23 AWG solid copper conductor for superior conductivity, Conductor diameter: 0.57 mm (23 AWG), supports Gigabit Ethernet (1000 Base-T) standard, Make -Molex/DLINK/similar, Inspection: Consignee. | — | — | — | 28,975 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CCTV_2.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
GCC Correction Slip2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910_1.pdf
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
GCCCorrectionslip11.pdf
ATTACHMENT
JPO_telecompolicycircular108_cableroutemarker.pdf
ATTACHMENT
CABLECUT_DiggingJPO_12.08.2024.pdf
ATTACHMENT
TypicaldiagramofEarthElectrodeGIPipe_2025.pdf
ATTACHMENT
Annexure-A.pdf
ATTACHMENT
ALLANNEXURENEW.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].