| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹37.4 L+₹1.0 L (2.79%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹38.9 L+₹2.4 L (6.72%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹43.8 L+₹7.4 L (20.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹44.8 L+₹8.4 L (23.1%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
30 Mar 2024, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
PROVISION OF SOLAR WATER GEYER AT VARIOUS SMQs, AND CERTAIN MINOR WROKS AT AF STATION BORGAD (PHASE-III)
2024_MES_644987_1
8127/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹84,000
Yes
1 Jun 2024
4 Mar 2024
2 Apr 2024
5 Mar 2024
30 Mar 2024
16 Mar 2024
Amount
Provision of soil resistivity testing as per standard engr practice & further recommending the quantity of earth required to achieve the desired results as per user requirement. Contractor will submit report from OEM of earthing and accordingly work will be executed.
Supply, install , testing and commissioning maintence free earthing comprising of high tensile pure copper (99.99%) earth electrode 76 mm dia and 3 mtr long copper pipe , intallation of earthing electrode boring 165mm dia X 4 mtr long with ground enhancing compound ( Make- Earthcon or equvalent ) and back-fill compound ( Make- Terec+ or equvalent ) (not less than 50 Kg ) strictly be a carbon based conductive concreate type which has resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for condition.Commissioning, testing & report submission ( result as per requirement of user in hard rock , mountain) etc. Note :-(1). Contractor will executed the work as per soil resistivity reports given by same OEM. However to achieve the result less than 1 Ohm gridding of earth pit should not exceed 4 Nos of earth pits. (2). To achieve results less than 1 ohm contractor will provide gridding of earth pits as per soil resistivity test report ( but not more than 4 earth pit). Artificial treatment of 12.5 Kg earthon compound per 2 meter as per dwawing attached and excutation and chemical required in area of gridding shall be included in rates quoted by contractor. (3) copper strip required for inter connection of gridding of earth pit shall be paid separtely. (4). Total 30 nos of earth pits of above specification to be executed at site. However gridding will be decided as per requirement of earth result and as soil resistivity report. (5) Copper strip of gridding shall be placed under groun level with the depth of 400 to 600 mm with the treatment of earthcon complound and alluvial soil as drawing.(6). removal of grabbles and stone and add some quantity of earth enhancement material in the soil using a black fill compound and make layer of blach siol / garden soil/ alluvial soil, terrace, compound and earthcon compound repeat tye same procedure around the 76 mm electrode pipe as per drawing. (7).Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty chamber with cover of suitable size as per OEM recommendation . Ground Enhancing compound and Back-fill compound should be enviroment freindly, , ionic property to create ions for easy conduction , the compound should expand so much to remove entrapped air ( bad conductor electricity ) and to creat strong conduction between electrode and soil , the compound should have a property to assist in absorbing humidity from the neightboringsoil to keep the earth pit moisture . The product should be tested and certified at CPRI for long term stability of earth pits. (8) Testing on completion & achiving resistance less than desire result & submitting report to Engineer-in Charge duly signed by user after seccessfull completion of earthing whytime after euevution up to end of defect liabuility perioed. (9) Earth strip copper of size 32x6mm from earth pit to testing point up to 7.5 mtr included in the quoted rates Make:- Yes Earthing ,SGI Engineers PVT Ltd, U protect. Note:- (1). Contractor will executed the work as per soil resistivity reports given by same OEM. However to achieve the result less than 1 Ohm gridding of earth pit should not exceed 4 Nos of earth pits. (2). To achieve results less than 1 ohm contractor will provide gridding of earth pits as per soil resistivity test report ( but not more than 4 earth pit). Artificial treatment of 12.5 Kg earthon compound per 2 meter as per dwawing attached and excutation and chemical required in area of gridding shall be included in rates quoted by contractor. (3) copper strip required for inter connection of gridding of earth pit shall be paid separtely. (4). Total 30 nos of earth pits of above specification to be executed at site. However gridding will be decided as per requirement of earth result and as soil resistivity report. (5) Copper strip of gridding shall be placed under groun level with the depth of 400 to 600 mm with the treatment of earthcon complound and alluvial soil as drawing.(6). removal of grabbles and stone and add some quantity of earth enhancement material in the soil using a black fill compound and make layer of blach siol / garden soil/ alluvial soil, terrace, compound and earthcon compound repeat tye same procedure around the 76 mm electrode pipe as per drawing attached in particular specification.
M&L for test point terminal block insulated from wall or external surface made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete fixed on ebonite sheet 6mm thick fitted on MS flat 50x5mm bent to shape etc complete all as specified and as directed.
Supply & fix copper strip 32X6 mm for gridding of earthing pits incl necessary connection of suitable size of nut , bolts and washers.
Supply, install, testing & commissioning hi wall split unit indoor/outdoor complete with cordless remote control unit and inverter type Inverter type air conditioner electric driven, single phase of capacity 2 TR, as specified and as directed by engineer-in-charge.Make Voltas, LLoyd, Blustar
Core cutting for making holes for inter connection of outdoor to indoor unit from stone/ brick masonry complete all as specified and as directed by Engr-in-charge.
Supply and fixing copper tubing with insulation for extension of connection from outdoor to indoor complete all as specified and as directed by Engineer -in-charge.
Supply and install voltage stablizer for automatic operation SP 50 HZ 220 V voltage varition between 170 to 280V. 0f capacity 5 KVA.
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
M&L wiring for circuit/ sub main wiring 2x4.0 Sqmm+1x4 Sqmm earth wire of PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in PVC conduit/cassing Capping as required in steel condute complete all as specified and directed by Engineer-In-charge
Supply anf fixing louver for 300 mm exhaust fan , made of GI sheet of suitable thickness, duly fixed on out side of the wall of existing building (G+3) with nuts, bolts and washers and making good the disturbed surface of the wall complete all as specified and as directed by Engr -in -Charge.
Disconnectiing of all electrical connections of the existing ceiling fan and taking down ceiling fan (any type/ sweep) from the ceiling and removing the existing down rod of the ceiling fan and depositing to MES store yard .
M & L for Anti sucide down rod made out of GI of length 10" (ten inch) capable to bear weight upto 20 KG and open from centre in case of weight more than 20 Kg by spring in pipe will be expand complete including making all electrical connection of the fan and hanging of fan ceiling on its original position. Make-Gold life smart fan rod, or as equivalent complete all as specified and as directed by Engr -in -Charge.
Supply,Install, Testing and commissioning of ''Solar Hot Water System'' (Evacuated tube collector) based on direct transfer of heat with electric back up of following capacity 200 LPD (Make Racold, V- Guard, Supreme)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces complete all as specified & directed by Engineer-In-Charge.
S&F Rotational moulded polyethylene water storage tanks for back up supply (cylindrical vertical with closed top) hoisted and fixed in position all as specified capacity of 500 Ltr.
S&F Bib taps 15 mm chromium plated cast copper alloy with crunch or buterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified & directed by Engineer-In-Charge.
Supply & Lay CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting in trenches/surface for hot water complete outer dia 15 mm all as specified & directed by Engineer-In-Charge.
(a)All as per item No- 12 above but 25 mm outer dia
Supply & Fix gun metal gate valve ISI marked screwed both ends of 25 mm dia bore complete all as specified & directed by Engineer-in-charge.
Supply & Fix Ball valve suitable for CPVC pipe of outer Dia 25 mm complete all as specified & directed by Engineer-In-Charge
S&F Brass Non-Return Valve 25 mm dia complete all as specified & as directed by Engineer in charge
Supply and laying on wall ,trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with stranded aluminium conductor 1100V grade 2 core cross sectional area 10 sqmm complete all as specified & directed by Engineer-In-Charge.
Supply & fix Double door sheet metal enclosure distribution board recessed mounting 230 volt SPN DB for DX3/Lexic MCB ,IP 54 IK-09 with metal door, 4 way of Make Legrand cat part No 507640 complete all as specified & as directed by Engineer in charge. (Note: Outgoing MCB will be measuserd & paid under relevant item)
Supply and fix MCB DP 32 amp,10KA, C curve,DX3 series of Make Legrand cat part no 408680 complete all as specified & as directed by Engineer in charge
S&F Sheet metal enclosure single door with socket plug top and MCBs triple pole and neutral enclosure with 3 pin and earth plug & socket complete with one triple pole MCB of 32 Amps 415 V complete all as specified & as directed by Engineer in charge
M & L for cement concrete 1:3:6 Type C2 using 40 mm graded stone aggregate as foundation/plinth of 125 KVA DG Set and including all necessary Earth work , finishing the surface even and smooth without using extra cement .complete all as specified and as directed by Engineer-In-Charge.
RAJLAKSHMI MULTISERVICES
SHRI SULAI ELECTRICALS
K R Electricals
M/S SVOJAS ELECTROMECH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .