| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.4 L+₹4.9 L (23.8%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹25.5 L+₹5.0 L (24.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹26.4 L+₹6.0 L (29.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹31.4 L+₹10.9 L (53.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Jul 2023, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair to internal wiring and replacement of electrical fittings in certain OTM Accn at ILP and KLP area under GE (Army) Suratgarh at Suratgarh Mil Stn
2023_MES_607254_1
GE (A) SOG - 27/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
SURATGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY SURATGARH
₹98,000
Yes
25 Aug 2023
30 Jun 2023
28 Jul 2023
30 Jun 2023
26 Jul 2023
14 Jul 2023
Amount
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, top sheet covers, fan regulators etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for Modular point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel terminal boxes and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer for mounting modular switches, sockets, fan regulator including suitable size modular plates fixed flush with wall including 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. Note : The quoted rate shall be deemed to included with modular cover plates with frame of any colour and metal flush boxes of suitable size as directed by Engr-in-Charge.
All as per serial item No. 2 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 2 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 2 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 2 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 2 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC sheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth dolly.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including concealed PVC rigid conduit medium grade 20mm dia with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 8 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 8 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 8 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 8 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 8 here-in-before but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in open conduit or existing concealed conduit in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 14 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 14 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 14 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 14 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 14 here-in-before but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F Modular switch piano 6 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 6 Amps single pole, two way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 16 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 2 / 3 pin, 6 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 6 pin, 6 / 16 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic fan regulator suitable for ceiling fan, 2 module, 1200mm / 1400mm sweep, socket size, step type complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 2 module, 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F as in repair of Energy efficient decorative ultra slim, prewired, Maxoled batten for T-8 LED retro lamp, ultra bright, glass shell, glare free, wide angle single/ double side connection retrofit LED tube with G-13 lamp holder/patti 20 watt LED light fitting (Day cool light) including 20 watt LED tube with all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LHFXCENNTN1W020 & LHLDDCXCML8Q020 / Crompton cat part No DIJB12LT8-20 & LGT8-16-865-2 or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
S&F as in repair of Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865S PCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
S&F as in repair of decorative wall light fixture madeup of polycarbonate having B-22 base including 9/10 watt LED bulb, wall mounted complete all as specified and as directed by Engineer-in-charge.
S&F as in repair of Recess mounting LED 2x2 luminaire, 36 watt, CCT 6000 k with drive, connector block etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting & connecting and testing complete all as specified and as directed by Engineer-in-charge. Make :- Crompton Cat Part No LCTLSNE-36-FO-CD / Philips Cat part No RC383B LED 36S-6500 PSU OD WH PIR / Syska Cat part No SSK-TVP-6060-36W / Havells Cat part No VENUSNEOHE2X2R36WLED840PIRSENSOR or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after. Note :- Warranty of 5 years or 50000 burning hours shall be given by the contractor.
S&F as in repair of LED light fitting 25 watt retrofit LED with complete accessories in a single piece deep drawn aluminium housing with anodizing inside and with acrylic cover fixed to wall with GI bracket made out of suitable size and testing complete all as specified and as directed by Engineer-in-charge.
S&F as in repair of LED post top 35 watt decorative circular design energy saving, IP 65 protection environmental freindly, long life aesthetically designed with symmetrical light distribution, cast aluminium body landscape luminaire with high power LEDs with polycarbonate type diffuser including two coat of black painting on existing post and cement work in base stand (spigot housing with decorative opal acrylic diffusser and IP 65 protection with all accessories complete all as specified and as directed by Engineer-in-charge.
S&F as in repair of LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F as in repair of flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair of flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair of flush mounting factory made SPN DB 12 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair of flush mounting factory made TPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCB 63 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCB 100 Amps, Triple pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair of Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F as in repair of Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old eathing complete all as specified and directed by Engr-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
S&F as in repair of street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F as in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular 6 sqmm solid conductor complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
S&F as in repair of sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCCB, 100 Amp, 4 Pole, 16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge.
S&F as in repair of MCCB, 125 Amp,4 Pole,16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular switch piano 6 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular switch piano 6 Amps single pole, two way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular switch piano 16 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular socket 2 / 3 pin, 6 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular socket 6 pin, 6 / 16 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair Modular electronic fan regulator suitable for ceiling fan, 2 module, 1200mm / 1400mm sweep, socket size, step type complete all as specified and directed by Engineer-in-charge.
S&F as in repair switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F as in repair switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge.
S&F as in repair switch piano flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F as in repair socket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F as in repair ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F as in repair Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F as in repair electronic fan regulator suitable for ceiling fan 2 module, 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge. ---------------------------------------------------------------------------- Note :- A sum of Rs. 104844/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 19 (R) & 20 (R) (Schedule of Credit) of Tender documents.
SHIVA BUILDERS
S.K BUILDERS AND ENGINEERS
BISHNOI BUILDERS
Aman Enterprises
jassal engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .