Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
21 May 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
office of the S.E., EUDC-II, Sec-18, Noida.
13 no 11 KV SS construction an Increasing Capicity TF
2024_PVVNL_922255_1
13 no 11 KV SS construction an Increasing Capicity TF
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
13 no 11 KV SS construction an Increasing Capicity TF
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹60,000
1 Jun 2024
15 Apr 2024
21 May 2024
15 Apr 2024
21 May 2024
15 Apr 2024
Amount
Installation of Distribution Transformer against overloaded transformers in under EUDD-III, NOIDA. (DETAIL OF WORK MENTIONED IN TENDER FORM)
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 17
100KVA 11/0.4KV New Distribution Transformer
250KVA 11/0.4KV New Distribution Transformer
PCC Pole 8.5 mtr. Long
ABC 3x120+1x95+1x16sqmm
ACSR Dog Conductor
ACSR Weasel Conductor
LT XLPE CABLE AL. 3.5X240Sqmm
Stone Pad
11KV TPMO with Polymer Insulator
MS Top Channel (125x65x2240mm)
MS Channel 100x50x2028mm
11KV Disc Insulator with Fitting
MS Channel (125x65x1300mm)
11KV Polymeric Pin Insulator with Pin
11KV Fuse Set
Stay set complete (G.I.Stay rod 16x1800mm, Stay wire 5Kg, Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 11KV line as per specification
Supply and Errection of the ABOVE Following material AND SUPPLY & ERRECTION OF THE FOLLOWING MATERIAL for completing the work as per RESPO.
Installation and Commissioning of 11/0.4 KV, 100 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC 8.5Mtr Long Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) PCC 8.5 Mtr Long Pole.
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long ST/PCC Pole and 8.5 Mtr Long PCC Pole
Installation and Fixing of 11 KV Fuse Set: Assembling and installation of fuse set on the fuse set structure of the T/F. The work includes fabrication for proper fixing, if required. Complete work in all respect.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying Fixing of LT XLPE Alu. Cable 3.5x400/240 sqmm at different locations of T/F as per site requirement. as per site requirement.
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Weasel conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Construction of New Plinth for 250KVA & above capacity Distribution Transformers, The size of plinth shall be 2M long 2m wide and the height of the plinth shall be 1.50 M with 20 cm. thick top slab with 02 no. 125x65mm MS channel 2 M long embedded in it. The repairing work includes excavation of earth, laying of brick ballast pad for foundation brickwork, CC and plastering and proper curing. The ratio of cement/course sand/fine sand/brick ballast/stone grit as per RESPO schedule including unloading and Loading of the transformer with complete work in all respect. (All work and material in the scope of the Contractor)
Mounting and installation of above 11 KV 200 Amp. TPMO (Air Break Heavy Duty Switches) with 02 Nos. 75mm X 40mm X 2800mm galvanised mounting channels complete with providing and fixing of required galvanised holding clamps, heavy duty GI pipe 25mm dia with operating handle mechanism, nuts & bolts with supporting channel etc. by the contractor complete in all respect.
Supply and Installation of 400Amp. LT ACB panel with Structure at Transformers as per site requirement with chemical earthing and making of Plinth of the ACB and complete work in all respect as per specification. C&S HAVELLS, ABB, HPL ETC.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF DISC. INSULATOR WITH FITTING AS PER SITE REQUIREMENT.
Providing and Fixing of clamp for Distribution Box Nut &bolt as per site requirement.
Providing and Fixing ofAlu. Leg Long Barrel off Size as per site requirement.
Providing of Best Quality Red Oxide Paint and Painting on Poles with complete work.
Providing of Best Quality Aluminium Paint and Painting on Poles with complete work.
Providing and Fixing of clamp for LT with Nut &bolt for t.off as per site requirement.
Providing and Fixing of Insulated Cable 1x35sqmm as per site requirement. GTP Approved
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
FIXING OF MS CHANNEL AS PER SITE REQUIREMENT.
Providing and Fixing of clamp for LT ABC with Nut &bolt for t.off as per site requirement.
Providing and Fixing of J Hook for Cable Hanging with Nut &bolt for t.off as per site requirement.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Providing and fixing of Stone Pad 300x300x75mm
Providing and fixing of Danger Board with Clamp and Nut & Bolt as per site requirement.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Providing and fixing of Hodling Clamp with Nut & Bolt and Washers for LT ABC and T-off as per site requirement.
Providing and fixing of Pad Lock for Distribution Box as per site requirement.
Removal of 2 Nos. 160KVA T/F and 01 No. 100 KVA T./F from different 03 Nos. Sites and carriage its to any Store of PVVNL including loading and unloading from both sides.
Shiv Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .