| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC M S GMR CO 151 2 MAHENDRA NILAYAM 11TH MAIN 2ND CROSS BEHIND SRI RAMA TEMPLE KAMMAGONDANAHALLI JALAHALLI WEST BANGALORE 560 015 | BENGALURU URBAN | KARNATAKA | 560015 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹32.7 L+₹6.6 L (25.5%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹33.4 L+₹7.4 L (28.3%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹35.0 L+₹8.9 L (34.2%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹35.4 L+₹9.3 L (35.8%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹65,800
Closing Date
16 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8736SPECIAL REPAIRS TO ELECTRICAL INFRASTRUCTURE AT 16 TS JALAHALLI EAST UNDER GE M AF STATION JALAHALLI BANGALORE
2022_MES_569996_1
8736/E8
Open Tender
Electrical and Maintenance Works
Item Rate
122 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹65,800
25 Feb 2023
19 Dec 2022
18 Jan 2023
19 Dec 2022
16 Jan 2023
2 Jan 2023
19 Dec 2022 - 26 Dec 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil obtained from excavation under item No 1 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness will be considered for payment.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
Material and labour for 3 ½ core 240 SqmmXLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed
All as per item No 06 herein before but for 3 ½ core 185 Sqmm
All as per item No 06 06 herein before but for 3 ½ core 120 Sqmm
All as per item No 06 06 herein before but for 3 ½ core 95 sqmm
Boring of holes under road, pavement hard standings by trenches technology using ultra sound technique and necessary machine including HDPE pipes of 100 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed by Engr-in-charge.
Supply and fixing ON LOAD change over switch 4 pole 400 A with sheet metal enclosure in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fasteners, burnt cables, accessories etc all as per site requirement/existing make/model all as specified and as directed. Make: L&T, HAVELLS, STANDARD, INDO ASIAN
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 32x6 mm (up to 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, check nuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as specified and directed by Engr-in-charge.
Fabricate supply install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removeable MS plates for fixing cable glands for all suitable for 300sqmm X3.5 core UG cable incoming and out going cables and complete control wiring with 2.5 sqmm copper conductor including necessary PCC foundation complete all specified and directed by Engineer-in-Charge. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. INCOMING (a) Aluminium bus bar of capacity 400 Amps with epoxy insulated supports 3 phase and neutral -1 set (b) MCCB 125 Amps 4 pole 16 KA with adjustable type - 01 No
Supply and laying of GI pipe light grade for cable protection of size 80mm bore complete with fitting complete all as specified and directed by Engr-In-Charge.
Forge Engineering & Electricals
SREE VARU ELECTRICALS
Shiva Shakthi Electrical Enterprises
ARUNOTHAYA TRADERS
NAVREET CONSTRUCTION
M/S SRI BALAJI ENTERPRISES
eurekaenterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .