MR Ahammad Danish
CE(Baster)
Construction of Govt. College Building at Kutru Block-Bhairamgarh Distt.-Bijapur (C.G.) i/c Electrification Works.
186030
NIT NO: 997/TC/2025-26
RESTRICTED TENDER
WORKS
12 days
CE(Baster)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
RESTRICTED TENDER
PERCENTAGE
A B
CE(Baster)
PWD Bastar Circle, Jagdalpur
Paschhim Baster Div. Bijapur
120
12
No
0
186030
9 Mar, 2026 5:00:00 PM IST
12 Mar, 2026 10:00:00 AM IST
20 Feb, 2026 6:00:00 PM IST
NIT NO: 997/TC/2025-26
Construction of Govt. College Building at Kutru Block-Bhairamgarh Distt.-Bijapur (C.G.) i/c Electrification Works.
228815.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
45763000.00
2
11 Mar, 2026 5:00:00 PM IST
45763000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
16d 22h 38m
6 documents required · 5 mandatory · 1 optional
₹0
₹2.3 L
20 Feb 2026
20 Feb 2026
12 Mar 2026
20 Feb 2026
9 Mar 2026
20 Feb 2026
11 Mar 2026
To enable entering data into the sheet, please click on 'Enable Editing'.
Please insert items from 12th row.
Every row will be considered as a distinct item.
The row, in which the two fields- 'Item Code' and 'Description' are blank, will not be considered.
If 'CREDIT ITEM' is not entered, default value '0' will be taken.
If 'Calc Field' is not entered, default value 'N' will be taken.
MAX ITEM LIMIT IN EACH EXCEL FILE IS 1000
N.I.T. SCHEDULE FOR CONSTRUCTION OF GOVT. COLLEGE BUILDING AT KUTRU BLOCK-BHAIRAMGARH , DIST.-BIJAPUR (C.G.)
Building S.O.R. w.e.f. 01/01/2015 with amendments upto 18/06/2025 S.O.R. & Electrification work w.e.f. 01-06-2020, Ammended up to 01-06-2020
P.A.C. Rs. 457.63 LACS
S..No. Department SOR Year Item no. Item of Works Unit Rate Qty. Amount Ref. Serial No. Credit Item (0/1) Calc Field Offset Price
1 PWD PWD BUILDING 2015 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). Sqm 7.2 N 0
2 PWD PWD BUILDING 2015 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils. Cum 185 N 0
3 PWD PWD BUILDING 2015 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils Cum 26.5 0 N 0
4 PWD PWD BUILDING 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). Cum 2970 N 0
5 PWD PWD BUILDING 2015 2.1.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. sqm 139 N 0
6 PWD PWD BUILDING 2015 2.1.3 Window sills, anchor blocks, string course, bends, copings, bed plates and like. sqm 184 0 N 0
7 PWD PWD BUILDING 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape. sqm 297 0 N 0
8 PWD PWD BUILDING 2015 2.1.8 Beams, lintels, cantilevers & walls. sqm 202 N 0
9 PWD PWD BUILDING 2015 2.1.13 Weather shade, chhajja, Cornices and mouldings Sqm 294 0 N 0
10 PWD PWD BUILDING 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235 N 0
11 PWD PWD BUILDING 2015 2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings sqm 230 48323.46 N 0
12 PWD PWD BUILDING 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). cum 4163 0 N 0
13 PWD PWD BUILDING 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 97.5 N 0
14 PWD PWD BUILDING 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415 Kg 54.5 0 N 0
15 PWD PWD BUILDING 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. Cum 371 N 0
16 PWD PWD BUILDING 2015 7.5.3 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:5 (1 cement : 5 coarse sand) cum 3350 N 0
17 PWD PWD BUILDING 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. cum 4237 N 0
18 PWD PWD BUILDING 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof ourse after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 93.5 0 N 0
19 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 121 38549.39 N 0
20 PWD PWD BUILDING 2015 7.11.1 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand) sqm 394 0 N 0
21 PWD PWD BUILDING 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 11 N 0
22 PWD PWD BUILDING 2015 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. sqm 62.5 N 0
23 PWD PWD BUILDING 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 91.5 0 N 0
24 PWD PWD BUILDING 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 107 N 0
25 PWD PWD BUILDING 2015 11.1.1 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:3 (1 cement : 3 fine sand) Cum 93 N 0
26 PWD PWD BUILDING 2015 11.13 Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level. sqm 134 0 N 0
27 PWD PWD BUILDING 2015 11.5 Neat Cement punning. sqm 33 N 0
28 PWD PWD BUILDING 2015 12.3.2 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50 mm thick sqm 254 N 0
29 PWD PWD BUILDING 2015 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. bag/kg 43.5 0 N 0
30 PWD PWD BUILDING 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. sqm 86 N 0
31 PWD PWD BUILDING 2018 12.74.1 Providing and laying rectified ceramic glazed floor tiles of 1st class quality confirming to IS : 15622-2017 of approved make, in all colours, shades over 20 mm thick bed of Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per SqM including pointing the joints with white cement mixed with matching pigment etc., complete. Size above 300x300 mm thickness 7 to 8 mm sqm 779 N 0
32 PWD PWD BUILDING 2018 12.74.3 Size above 600x600 mm thickness 8 to 9 mm sqm 897 N 0
33 PWD PWD BUILDING 2018 12.75.2 Providing and fixing ceramic glazed wall/dado tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size 300x600mm thickness 7 to 8mm sqm 850 N 0
34 PWD PWD BUILDING 2015 12.49 25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm) sqm 897 0 N 0
35 PWD PWD BUILDING 2015 13.6.2 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone black sqm 3279 N 0
36 PWD PWD BUILDING 2015 13.19.2 Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work sqm 172 0 N 0
37 PWD PWD BUILDING 2015 12.46.2 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). Granite stone black sqm 2719 N 0
38 PWD PWD BUILDING 2015 12.44 Extra for nosing in Granite stone for treads. Rm 126 0 N 0
39 PWD PWD BUILDING 2015 12.37.2 Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade using approximately. 50% white cement and 50% ordinary cement. sqm 591 43497.6 N 0
40 PWD PWD BUILDING 2015 3.1.4 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). sqm 3552 0 N 0
41 PWD PWD BUILDING 2015 9.18.4 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc hromate primer. Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet. Rm 474 0 N 0
42 PWD PWD BUILDING 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. Rm 346 N 0
43 PWD PWD BUILDING 2015 8.152.1 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). PVC door shutter sqm 2318 N 0
44 PWD PWD BUILDING 2015 8.12.2 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 35 mm. thick (single leaf) sqm 2005 0 N 0
45 PWD PWD BUILDING 2015 8.15 Extra for double leaf shutter instead of single leaf. sqm 52 N 0
46 PWD PWD BUILDING 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm 3330 N 0
47 PWD PWD BUILDING 2015 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for arately: For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). Kg 338 N 0
48 PWD PWD BUILDING 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. Kg 27 N 0
49 PWD PWD BUILDING 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness sqm 708 0 N 0
50 PWD PWD BUILDING 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. Kg 67.5 347733 N 0
51 PWD PWD BUILDING 2015 9.57.1 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 204 Kg 467 N 0
52 PWD PWD BUILDING 2015 8.132.2 Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 125x2.5mm (heavy) each 76.5 N 0
53 PWD PWD BUILDING 2015 8.137.1 Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm each 238 N 0
54 PWD PWD BUILDING 2015 8.138.1 Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 300mm each 92.5 N 0
55 PWD PWD BUILDING 2015 8.138.2 250mm each 85 N 0
56 PWD PWD BUILDING 2015 8.139.1 Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm each 97 N 0
57 PWD PWD BUILDING 2015 8.139.2 200 x10mm each 70.5 N 0
58 PWD PWD BUILDING 2015 8.141.1 Providing and fixing Stainless steel "D" shape door handles made of 10mm dia rod with necessary stainless steel screws etc complete. 200 mm each 64 N 0
59 PWD PWD BUILDING 2015 8.143.2 Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Double each 65 N 0
60 PWD PWD BUILDING 2015 Providing and laying French sprit polish on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if isible, applying a coat of wood filler, cleaning the surface, applying 50 or more coats of French spirit polish till the surface gives high gloss inclusive of abro tape etc complete for work. sqm 454 N 0
61 PWD PWD BUILDING 2015 Providing and applying 2mm thick white cement base acrylic grade putty with min 3 coats applied as per IS: 17545:2021 (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) items to be used in heigher grade painting 14.65 sqm 95 N 0
62 PWD PWD BUILDING 2015 Providing and applying satin/ matt finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10sqm upto req finish as per relevant : 2932:2013 of labour etc . Complete for work. sqm 133 N 0
63 PWD PWD BUILDING 2015 Providing and applying premium plkastic emulsion paint with roller application mon 3 coats as per IS Code:15489:2013Type 1 and labour etc complete for the work.(with 3 year warranty) sqm 84 0 N 0
64 PWD PWD BUILDING 2015 Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and waterproof finish minimum 3 coats applied @ 14.10 litre /10 sqm as IS Code: 15489:2013 Type 2 decorative finish including cleaning washing of surface etc. complete with: etc complete for the work.(with 3 year warranty) sqm 84 342218.52 N 0
65 PWD PWD BUILDING 2015 1.25.1 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm sqm 27.5 0 N 0
66 PWD PWD BUILDING 2015 1.25.2 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). Rm 19 N 0
67 PWD PWD BUILDING 2015 61 1.25.3 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor)Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). Rm 13.5 N 0
68 PWD PWD BUILDING 2015 1.22 Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. Litre 208 0 N 0
69 PWD PWD BUILDING 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 195 N 0
70 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 242 N 0
71 PWD PWD BUILDING 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 22 N 0
72 PWD PWD BUILDING 2015 Extra for fixing glazed/floor tiles with cement based high polymer modified quick-set tile adhesive confirming to IS 15477 for interiar exterior applications. sqm 202 N 0
73 PWD PWD BUILDING 2016 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Cum 292.5 0 N 0
74 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 363 N 0
75 PWD PWD BUILDING 2015 4.13.1 Grading for water profing treatment with cement concrete 1:2:4 with 20mm nominal size stone agreegate Cum 3817 0 N 0
76 PWD PWD BUILDING 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm Each 2459 N 0
77 PWD PWD BUILDING 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type Each 2882 N 0
78 PWD PWD BUILDING 2015 18.9.1 Providing and fixing ISI marked plastic seat with lid for pedestal type W.C. pan complete: White/ black Each 620 N 0
79 PWD PWD BUILDING 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm Each 1430 N 0
80 PWD PWD BUILDING 2015 18.21.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 1040x510 mm bowl size 460x410x200 mm Each 8539 N 0
81 PWD PWD BUILDING 2015 18.25.2 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia Each 88.5 N 0
82 PWD PWD BUILDING 2015 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 599 N 0
83 PWD PWD BUILDING 2015 18.10.2 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: 45 CM length Each 66.5 N 0
84 PWD PWD BUILDING 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back half stall urinal of size 460x380x250mm Each 1776 N 0
85 PWD PWD BUILDING 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : Each 2014 N 0
86 PWD PWD BUILDING 2015 18.78.2 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm Each 61 N 0
87 PWD PWD BUILDING 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe. Metre. 182 N 0
88 PWD PWD BUILDING 2015 18.76.2 110 mm dia pipe. Metre. 267 N 0
89 PWD PWD BUILDING 2015 18.77.1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm Each 113 N 0
90 PWD PWD BUILDING 2015 18.77.1.2 110 mm Each 154 N 0
91 PWD PWD BUILDING 2015 18.77.2.2 Double "Y" with or without door 75 mm each 224 N 0
92 PWD PWD BUILDING 2015 18.77.3.2 Vent covel 110 mm each 44 N 0
93 PWD PWD BUILDING 2015 18.77.5 "P" trap 110mmx110mm long Each 227 N 0
94 PWD PWD BUILDING 2015 18.77.6 Nahani trap 110x75mm Each 90.5 N 0
95 PWD PWD BUILDING 2015 19.7.1 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 15 mm dia. nominal bore Metre. 149 N 0
96 PWD PWD BUILDING 2015 19.7.3 25 mm dia. nominal bore Metre. 258 N 0
97 PWD PWD BUILDING 2015 19.7.4 32 mm dia. nominal bore Metre. 318 N 0
98 PWD PWD BUILDING 2015 19.7.6 50 mm dia. nominal bore Metre. 471 N 0
99 PWD PWD BUILDING 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) Each 382 N 0
100 PWD PWD BUILDING 2015 19.14.3 Long body bib cock (500 grams) each 426 N 0
101 PWD PWD BUILDING 2015 19.14.5 Two way bib cock (800 grams) each 708 N 0
102 PWD PWD BUILDING 2015 19.14.6 Stop cock (concealed) (600 grams) Each 494 N 0
103 PWD PWD BUILDING 2015 19.14.7 Angle valve for basin mixer and geyser points (450 grams) each 382 N 0
104 PWD PWD BUILDING 2015 19.14.14 Soap dish plate each 163 N 0
105 PWD PWD BUILDING 2015 19.14.15 Shower rose (revolving type) (150mm) Each 269 N 0
106 PWD PWD BUILDING 2015 19.14.16 Towel rail (600mm long x 20mm dia) Each 338 N 0
107 PWD PWD BUILDING 2015 19.14.20 CP brass water jet to be fixed in seat cover of WC with flexible connection pipe Set 577 N 0
108 PWD PWD BUILDING 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. Each 51 N 0
109 PWD PWD BUILDING 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) :25 mm nominal bore each 413 N 0
110 PWD PWD BUILDING 2015 19.18.2 32 mm nominal bore each 556 N 0
111 PWD PWD BUILDING 2015 19.18.4 50 mm nominal bore each 993 N 0
112 PWD PWD BUILDING 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Liter 7.3 N 0
113 PWD PWD BUILDING 2015 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : each 754 N 0
114 PWD PWD BUILDING 2015 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 4644 N 0
115 PWD PWD BUILDING 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter Metre. 262 N 0
116 PWD PWD BUILDING 2015 20.1.3 200 mm diameter Metre. 506 N 0
117 PWD PWD BUILDING 2015 20.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. pipe Metre. 436 N 0
118 PWD PWD BUILDING 2015 20.2.3 200 mm diameter S.W. pipe Metre. 508 N 0
119 PWD PWD BUILDING 2015 20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. each 1709 N 0
120 PWD PWD BUILDING 2015 20.3.1 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100x100 mm size P type each 1339 N 0
121 PWD PWD BUILDING 2015 20.5.2 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe Rm 353 N 0
122 PWD PWD BUILDING 2015 20.7.1 Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : each 6703 N 0
123 PWD PWD BUILDING 2015 Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre) Lit. 18.5 N 0
124 PWD PWD BUILDING 2015 Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter. each 644 N 0
125 PWD PWD BUILDING 2015 3.1.5 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) Cum 4073 0 N 0
126 PWD PWD BUILDING 2015 11.3.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix : In Cement Mortar 1:5 (1 cement : 5 fine sand) Sqm 113 N 0
127 PWD PWD BUILDING 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.. Sqm 587 N 0
128 PWD PWD BUILDING 2015 Providing and laying ceramic glazed floor tiles conforming to IS : 15622of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size 300x300mm Sqm 692 N 0
129 PWD PWD BUILDING 2015 21.2.1.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 150 mm dia. Metre. 371 N 0
130 PWD PWD BUILDING 2015 21.2.2.3 Rocky strata including Boulders. 150 mm dia. Metre. 424 N 0
131 PWD PWD BUILDING 2015 21.3.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. Metre. 540 N 0
132 PWD PWD BUILDING 2015 21.6.3 Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part- 1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-incharge 150 mm nominal dia Metre. 1317 N 0
133 PWD PWD BUILDING 2015 Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 1048 0 N 0
134 PWD PWD BUILDING 2015 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) Point 1502 N 0
135 PWD PWD BUILDING 2015 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). Cum 201 0 N 0
136 PWD PWD BUILDING 2015 22.3 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). Cum 248 N 0
137 PWD PWD BUILDING 2015 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). Cum 236 N 0
138 PWD PWD BUILDING 2015 22.7 Fine dressing the ground sqm 1098 0 N 0
139 PWD PWD BUILDING 2015 22.9 Mixing earth and sludge or manure in proportion specified or directed. Cum 11 N 0
140 PWD PWD BUILDING 2015 22.25.1 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hedges like Alife, Dorenta, Tikoma etc each 14 N 0
141 PWD PWD BUILDING 2015 22.25.2 Furn like Arica, China etc (3 year old) each 125 N 0
142 PWD PWD BUILDING 2015 22.25.3 Hibiscus (Flower)/ Rose each 26.5 N 0
143 PWD PWD BUILDING 2015 22.25.4 Carpet grass (well developed) each 263 N 0
144 PWD ELECT 2020 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point Point 266 0 N 0
145 PWD ELECT 2020 1.7.2 Medium Point Point 424 0 N 0
146 PWD ELECT 2020 1.7.3 Long Point Point 588 0 N 0
147 PWD ELECT 2020 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 420 0 N 0
148 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 216 0 N 0
149 PWD ELECT 2020 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point Point 442 0 N 0
150 PWD ELECT 2020 1.10.2 Medium Point Point 659 0 N 0
151 PWD ELECT 2020 1.10.3 Long Point Point 922 0 N 0
152 PWD ELECT 2020 1.10.4 Extra Long Point I Point 1302 0 N 0
153 PWD ELECT 2020 1.10.5 Extra Long Point II Point 1657 0 N 0
154 PWD ELECT 2020 1.10.6 Extra Long Point III Point 1995 0 N 0
155 PWD ELECT 2020 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point Point 589 0 N 0
156 PWD ELECT 2020 1.11.2 Medium Point Point 942 0 N 0
157 PWD ELECT 2020 1.11.3 Long Point Point 1350 0 N 0
158 PWD ELECT 2020 1.11.4 Extra Long Point I Point 1807 0 N 0
159 PWD ELECT 2020 1.11.5 Extra Long Point II Point 2315 0 N 0
160 PWD ELECT 2020 1.11.6 Extra Long Point III Point 2825 0 N 0
161 PWD ELECT 2020 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit Metre 92 0 N 0
162 PWD ELECT 2020 1.13.2 3 x 2.5 sqmm in 20mm conduit Meter 111 0 N 0
163 PWD ELECT 2020 1.13.3 6 x 2.5 sqmm in 25mm conduit Meter 172 0 N 0
164 PWD ELECT 2020 1.13.4 9 x 2.5 sqmm in 32mm conduit Meter 238 0 N 0
165 PWD ELECT 2020 1.13.5 12 x 2.5 sqmm in 32mm conduit Meter 288 0 N 0
166 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Meter 223 0 N 0
167 PWD ELECT 2020 5.4.22 Batten/ angle holder Each 41 0 N 0
168 PWD ELECT 2020 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe Each 107 0 N 0
169 PWD ELECT 2020 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. Each 42 0 N 0
170 PWD ELECT 2020 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep Each 1697 0 N 0
171 PWD ELECT 2020 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 31 0 N 0
172 PWD ELECT 2020 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan) Each 56 0 N 0
173 PWD ELECT 2020 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep Each 2446 0 N 0
174 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.4 36 watt {4 feet} Each 718 0 N 0
175 PWD ELECT 2020 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.4 9 Watt Each 143 0 N 0
176 PWD ELECT 2020 6.17.5 12 Watt Each 215 0 N 0
177 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.8 90 watt Each 5531 0 N 0
178 PWD ELECT 2020 6.28.9 120 watt Each 6844 0 N 0
179 PWD ELECT 2020 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm) Metre 717 0 N 0
180 PWD ELECT 2020 7.20.2 200 amp (30x5mm) Metre 907 0 N 0
181 PWD ELECT 2020 7.20.4 400 amp (50x6mm) Metre 1531 0 N 0
182 PWD ELECT 2020 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep sqm 6818 0 N 0
183 PWD ELECT 2020 7.19.2 Above 300 mm and upto 450 mm deep sqm 7525 0 N 0
184 PWD ELECT 2020 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.4 3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA Each 3734 0 N 0
185 PWD ELECT 2020 9.1.9 3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA Each 12006 0 N 0
186 PWD ELECT 2020 9.1.36 4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA Each 20356 0 N 0
187 PWD ELECT 2020 9.8 Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 9.8.5 4 way (4 + 12), Double door Each 5904 0 N 0
188 PWD ELECT 2020 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps Each 148 0 N 0
189 PWD ELECT 2020 9.20 Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 40 amps Each 568 0 N 0
190 PWD ELECT 2020 9.20.2 63 amps Each 621 0 N 0
191 PWD ELECT 2020 Providing and fixing metal clad, 4 pole, on load change over switch unit (without sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 10.6.5 400 amps Each 21184 0 N 0
192 PWD ELECT 2020 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.3 200/5 amps Each 347 0 N 0
193 PWD ELECT 2020 10.15.6 500/5 amps Each 361 0 N 0
194 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 94 0 N 0
195 PWD ELECT 2020 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. Each 1201 0 N 0
196 PWD ELECT 2020 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound. Each 10955 0 N 0
197 PWD ELECT 2020 12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound. Each 8222 0 N 0
198 PWD ELECT 2020 12.5 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 513 0 N 0
199 PWD ELECT 2020 12.17 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification. Metre 38 0 N 0
200 PWD ELECT 2020 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate having 4 nos holes for fixing etc. complete as per specification. Each 767 0 N 0
201 PWD ELECT 2020 Making jointing of copper tape (with another copper tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as per specification. Each 51 0 N 0
202 PWD ELECT 2020 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For horizontal run) Metre 217 0 N 0
203 PWD ELECT 2020 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For vertical run) Metre 219 0 N 0
204 PWD ELECT 2020 Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as per specification. Each 93 0 N 0
205 PWD ELECT 2020 Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as per specification. Metre 654 0 N 0
206 PWD ELECT 2020 14.1 Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.1 63 mm outer dia and 50 mm Inner dia Metre 184 0 N 0
207 PWD ELECT 2020 14.1.3 90 mm outer dia and 75 mm Inner dia Metre 203 0 N 0
208 PWD ELECT 2020 15.1 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.1.14 3.5 x 70 sq. mm. Metre 451 0 N 0
209 PWD ELECT 2020 15.1.16 3.5 x 120 sq. mm. Metre 544 0 N 0
210 PWD ELECT 2020 15.1.19 3.5 x 240 sq. mm. Metre 955 0 N 0
211 PWD ELECT 2020 15.1.22 4 x 10 sq. mm. Metre 293 0 N 0
212 PWD ELECT 2020 15.1.23 4 x 16 sq. mm. Metre 300 0 N 0
213 PWD ELECT 2020 15.1.24 4 x 25 sq. mm. Metre 321 0 N 0
214 PWD ELECT 2020 15.5 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.5.14 4 x 16 sq. mm. Metre 126 0 N 0
215 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.15 3½ X 70 sq. mm (35 mm) Each 199 0 N 0
216 PWD ELECT 2020 15.23.17 3½ X 120 sq. mm (45 mm) Each 283 0 N 0
217 PWD ELECT 2020 15.23.20 3½ X 240 sq. mm (57 mm) Each 504 0 N 0
218 PWD ELECT 2020 15.23.23 4 X 10 sq. mm (22 mm) Each 98 0 N 0
219 PWD ELECT 2020 15.23.24 4 X 16 sq. mm (22 mm) Each 101 0 N 0
220 PWD ELECT 2020 15.23.25 4 X 25 sq. mm (25 mm) Each 104 0 N 0
221 PWD ELECT 2020 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.7.3 8 metre high, dia 135mm at bottom and 90mm at top, base plate size 225x225x16mm, foundation bolts 750mm long Each 11853 0 N 0
222 PWD ELECT 2020 19.4 Supply of GI PIPE POLE made of "B" class GI pipe making necessary hole for cable entry and providing earthing stud (welded at specified height) including painting with one coat of red oxide zinc chromate primer. 19.4.1 50 mm dia Metre 398 0 N 0
223 PWD ELECT 2020 19.4.2 65 mm dia Metre 498 0 N 0
224 PWD ELECT 2020 19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. 19.9.2 Single Over Hang 1.00 metre Long Each 1057 0 N 0
225 PWD ELECT 2020 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 19.11.6 8 metre high Each 924 0 N 0
226 PWD ELECT 2020 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification. cum 5219 0 N 0
227 PWD ELECT 2020 30.2 Earth work in soft rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification cum 210 0 N 0
SAY 457.63 LACS
To enable entering data into the sheet, please click on 'Enable Editing'.
Please insert items from 12th row.
Every row will be considered as a distinct item.
The row, in which the two fields- 'Item Code' and 'Description' are blank, will not be considered.
If 'CREDIT ITEM' is not entered, default value '0' will be taken.
If 'Calc Field' is not entered, default value 'N' will be taken.
MAX ITEM LIMIT IN EACH EXCEL FILE IS 1000
N.I.T. SCHEDULE FOR CONSTRUCTION OF GOVT. COLLEGE BUILDING AT KUTRU BLOCK: BHAIRAMGARH , DIST.-BIJAPUR (C.G.)
Building S.O.R. w.e.f. 01/01/2015 with amendments upto 18/06/2025 S.O.R. & Electrification work w.e.f. 01-06-2020, Ammended up to 01-06-2020
P.A.C. Rs. 451.98 Iacs
S..No. Department SOR Year Item no. Item of Works Unit Rate Qty. Amount Ref. Serial No. Credit Item (0/1) Calc Field Offset Price
1 PWD PWD BUILDING 2015 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). Sqm 7.2 N 0
2 PWD PWD BUILDING 2015 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils. Cum 185 N 0
3 PWD PWD BUILDING 2015 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils Cum 26.5 0 N 0
4 PWD PWD BUILDING 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). Cum 2970 N 0
5 PWD PWD BUILDING 2015 2.1.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. sqm 139 N 0
6 PWD PWD BUILDING 2015 2.1.3 Window sills, anchor blocks, string course, bends, copings, bed plates and like. sqm 184 0 N 0
7 PWD PWD BUILDING 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape. sqm 297 0 N 0
8 PWD PWD BUILDING 2015 2.1.8 Beams, lintels, cantilevers & walls. sqm 202 N 0
9 PWD PWD BUILDING 2015 2.1.13 Weather shade, chhajja, Cornices and mouldings Sqm 294 0 N 0
10 PWD PWD BUILDING 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235 N 0
11 PWD PWD BUILDING 2015 2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings sqm 230 48323.46 N 0
12 PWD PWD BUILDING 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). cum 4163 0 N 0
13 PWD PWD BUILDING 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 97.5 N 0
14 PWD PWD BUILDING 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415 Kg 54.5 0 N 0
15 PWD PWD BUILDING 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. Cum 371 N 0
16 PWD PWD BUILDING 2015 7.5.3 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:5 (1 cement : 5 coarse sand) cum 3350 N 0
17 PWD PWD BUILDING 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. cum 4237 N 0
18 PWD PWD BUILDING 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof ourse after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 93.5 0 N 0
19 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 121 38549.39 N 0
20 PWD PWD BUILDING 2015 7.11.1 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand) sqm 394 0 N 0
21 PWD PWD BUILDING 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 11 N 0
22 PWD PWD BUILDING 2015 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. sqm 62.5 N 0
23 PWD PWD BUILDING 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 91.5 0 N 0
24 PWD PWD BUILDING 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 107 N 0
25 PWD PWD BUILDING 2015 11.1.1 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:3 (1 cement : 3 fine sand) Cum 93 N 0
26 PWD PWD BUILDING 2015 11.13 Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level. sqm 134 0 N 0
27 PWD PWD BUILDING 2015 11.5 Neat Cement punning. sqm 33 N 0
28 PWD PWD BUILDING 2015 12.3.2 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50 mm thick sqm 254 N 0
29 PWD PWD BUILDING 2015 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. bag/kg 43.5 0 N 0
30 PWD PWD BUILDING 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. sqm 86 N 0
31 PWD PWD BUILDING 2018 12.74.1 Providing and laying rectified ceramic glazed floor tiles of 1st class quality confirming to IS : 15622-2017 of approved make, in all colours, shades over 20 mm thick bed of Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per SqM including pointing the joints with white cement mixed with matching pigment etc., complete. Size above 300x300 mm thickness 7 to 8 mm sqm 779 N 0
32 PWD PWD BUILDING 2018 12.74.3 Size above 600x600 mm thickness 8 to 9 mm sqm 897 N 0
33 PWD PWD BUILDING 2018 12.75.2 Providing and fixing ceramic glazed wall/dado tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size 300x600mm thickness 7 to 8mm sqm 850 N 0
34 PWD PWD BUILDING 2015 12.49 25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm) sqm 897 0 N 0
35 PWD PWD BUILDING 2015 13.6.2 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone black sqm 3279 N 0
36 PWD PWD BUILDING 2015 13.19.2 Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work sqm 172 0 N 0
37 PWD PWD BUILDING 2015 12.46.2 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). Granite stone black sqm 2719 N 0
38 PWD PWD BUILDING 2015 12.44 Extra for nosing in Granite stone for treads. Rm 126 0 N 0
39 PWD PWD BUILDING 2015 12.37.2 Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade using approximately. 50% white cement and 50% ordinary cement. sqm 591 43497.6 N 0
40 PWD PWD BUILDING 2015 3.1.4 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). sqm 3552 0 N 0
41 PWD PWD BUILDING 2015 9.18.4 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc hromate primer. Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet. Rm 474 0 N 0
42 PWD PWD BUILDING 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. Rm 346 N 0
43 PWD PWD BUILDING 2015 8.152.1 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). PVC door shutter sqm 2318 N 0
44 PWD PWD BUILDING 2015 8.12.2 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 35 mm. thick (single leaf) sqm 2005 0 N 0
45 PWD PWD BUILDING 2015 8.15 Extra for double leaf shutter instead of single leaf. sqm 52 N 0
46 PWD PWD BUILDING 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm 3330 N 0
47 PWD PWD BUILDING 2015 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for arately: For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). Kg 338 N 0
48 PWD PWD BUILDING 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. Kg 27 N 0
49 PWD PWD BUILDING 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness sqm 708 0 N 0
50 PWD PWD BUILDING 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. Kg 67.5 347733 N 0
51 PWD PWD BUILDING 2015 9.57.1 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 204 Kg 467 N 0
52 PWD PWD BUILDING 2015 8.132.2 Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 125x2.5mm (heavy) each 76.5 N 0
53 PWD PWD BUILDING 2015 8.137.1 Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm each 238 N 0
54 PWD PWD BUILDING 2015 8.138.1 Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 300mm each 92.5 N 0
55 PWD PWD BUILDING 2015 8.138.2 250mm each 85 N 0
56 PWD PWD BUILDING 2015 8.139.1 Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm each 97 N 0
57 PWD PWD BUILDING 2015 8.139.2 200 x10mm each 70.5 N 0
58 PWD PWD BUILDING 2015 8.141.1 Providing and fixing Stainless steel "D" shape door handles made of 10mm dia rod with necessary stainless steel screws etc complete. 200 mm each 64 N 0
59 PWD PWD BUILDING 2015 8.143.2 Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Double each 65 N 0
60 PWD PWD BUILDING 2015 Providing and laying French sprit polish on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if isible, applying a coat of wood filler, cleaning the surface, applying 50 or more coats of French spirit polish till the surface gives high gloss inclusive of abro tape etc complete for work. sqm 454 N 0
61 PWD PWD BUILDING 2015 Providing and applying 2mm thick white cement base acrylic grade putty with min 3 coats applied as per IS: 17545:2021 (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) items to be used in heigher grade painting 14.65 sqm 95 N 0
62 PWD PWD BUILDING 2015 Providing and applying satin/ matt finish enamel paint minimum 2 coats in all surface applying @0.75 lit/10sqm upto req finish as per relevant : 2932:2013 of labour etc . Complete for work. sqm 133 N 0
63 PWD PWD BUILDING 2015 Providing and applying premium plkastic emulsion paint with roller application mon 3 coats as per IS Code:15489:2013Type 1 and labour etc complete for the work.(with 3 year warranty) sqm 84 0 N 0
64 PWD PWD BUILDING 2015 Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and waterproof finish minimum 3 coats applied @ 14.10 litre /10 sqm as IS Code: 15489:2013 Type 2 decorative finish including cleaning washing of surface etc. complete with: etc complete for the work.(with 3 year warranty) sqm 84 342218.52 N 0
65 PWD PWD BUILDING 2015 1.25.1 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm sqm 27.5 0 N 0
66 PWD PWD BUILDING 2015 1.25.2 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). Rm 19 N 0
67 PWD PWD BUILDING 2015 61 1.25.3 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor)Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). Rm 13.5 N 0
68 PWD PWD BUILDING 2015 1.22 Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. Litre 208 0 N 0
69 PWD PWD BUILDING 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 195 N 0
70 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 242 N 0
71 PWD PWD BUILDING 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 22 N 0
72 PWD PWD BUILDING 2015 Extra for fixing glazed/floor tiles with cement based high polymer modified quick-set tile adhesive confirming to IS 15477 for interiar exterior applications. sqm 202 N 0
73 PWD PWD BUILDING 2016 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Cum 292.5 0 N 0
74 PWD PWD BUILDING 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 363 N 0
75 PWD PWD BUILDING 2015 4.13.1 Grading for water profing treatment with cement concrete 1:2:4 with 20mm nominal size stone agreegate Cum 3817 0 N 0
76 PWD PWD BUILDING 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm Each 2459 N 0
77 PWD PWD BUILDING 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type Each 2882 N 0
78 PWD PWD BUILDING 2015 18.9.1 Providing and fixing ISI marked plastic seat with lid for pedestal type W.C. pan complete: White/ black Each 620 N 0
79 PWD PWD BUILDING 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm Each 1430 N 0
80 PWD PWD BUILDING 2015 18.21.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 1040x510 mm bowl size 460x410x200 mm Each 8539 N 0
81 PWD PWD BUILDING 2015 18.25.2 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia Each 88.5 N 0
82 PWD PWD BUILDING 2015 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 599 N 0
83 PWD PWD BUILDING 2015 18.10.2 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: 45 CM length Each 66.5 N 0
84 PWD PWD BUILDING 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back half stall urinal of size 460x380x250mm Each 1776 N 0
85 PWD PWD BUILDING 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : Each 2014 N 0
86 PWD PWD BUILDING 2015 18.78.2 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm Each 61 N 0
87 PWD PWD BUILDING 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe. Metre. 182 N 0
88 PWD PWD BUILDING 2015 18.76.2 110 mm dia pipe. Metre. 267 N 0
89 PWD PWD BUILDING 2015 18.77.1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm Each 113 N 0
90 PWD PWD BUILDING 2015 18.77.1.2 110 mm Each 154 N 0
91 PWD PWD BUILDING 2015 18.77.2.2 Double "Y" with or without door 75 mm each 224 N 0
92 PWD PWD BUILDING 2015 18.77.3.2 Vent covel 110 mm each 44 N 0
93 PWD PWD BUILDING 2015 18.77.5 "P" trap 110mmx110mm long Each 227 N 0
94 PWD PWD BUILDING 2015 18.77.6 Nahani trap 110x75mm Each 90.5 N 0
95 PWD PWD BUILDING 2015 19.7.1 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 15 mm dia. nominal bore Metre. 149 N 0
96 PWD PWD BUILDING 2015 19.7.3 25 mm dia. nominal bore Metre. 258 N 0
97 PWD PWD BUILDING 2015 19.7.4 32 mm dia. nominal bore Metre. 318 N 0
98 PWD PWD BUILDING 2015 19.7.6 50 mm dia. nominal bore Metre. 471 N 0
99 PWD PWD BUILDING 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) Each 382 N 0
100 PWD PWD BUILDING 2015 19.14.3 Long body bib cock (500 grams) each 426 N 0
101 PWD PWD BUILDING 2015 19.14.5 Two way bib cock (800 grams) each 708 N 0
102 PWD PWD BUILDING 2015 19.14.6 Stop cock (concealed) (600 grams) Each 494 N 0
103 PWD PWD BUILDING 2015 19.14.7 Angle valve for basin mixer and geyser points (450 grams) each 382 N 0
104 PWD PWD BUILDING 2015 19.14.14 Soap dish plate each 163 N 0
105 PWD PWD BUILDING 2015 19.14.15 Shower rose (revolving type) (150mm) Each 269 N 0
106 PWD PWD BUILDING 2015 19.14.16 Towel rail (600mm long x 20mm dia) Each 338 N 0
107 PWD PWD BUILDING 2015 19.14.20 CP brass water jet to be fixed in seat cover of WC with flexible connection pipe Set 577 N 0
108 PWD PWD BUILDING 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. Each 51 N 0
109 PWD PWD BUILDING 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) :25 mm nominal bore each 413 N 0
110 PWD PWD BUILDING 2015 19.18.2 32 mm nominal bore each 556 N 0
111 PWD PWD BUILDING 2015 19.18.4 50 mm nominal bore each 993 N 0
112 PWD PWD BUILDING 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Liter 7.3 N 0
113 PWD PWD BUILDING 2015 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : each 754 N 0
114 PWD PWD BUILDING 2015 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 4644 N 0
115 PWD PWD BUILDING 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter Metre. 262 N 0
116 PWD PWD BUILDING 2015 20.1.3 200 mm diameter Metre. 506 N 0
117 PWD PWD BUILDING 2015 20.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. pipe Metre. 436 N 0
118 PWD PWD BUILDING 2015 20.2.3 200 mm diameter S.W. pipe Metre. 508 N 0
119 PWD PWD BUILDING 2015 20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. each 1709 N 0
120 PWD PWD BUILDING 2015 20.3.1 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100x100 mm size P type each 1339 N 0
121 PWD PWD BUILDING 2015 20.5.2 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe Rm 353 N 0
122 PWD PWD BUILDING 2015 20.7.1 Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : each 6703 N 0
123 PWD PWD BUILDING 2015 Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre) Lit. 18.5 N 0
124 PWD PWD BUILDING 2015 Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter. each 644 N 0
125 PWD PWD BUILDING 2015 3.1.5 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) Cum 4073 0 N 0
126 PWD PWD BUILDING 2015 11.3.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix : In Cement Mortar 1:5 (1 cement : 5 fine sand) Sqm 113 N 0
127 PWD PWD BUILDING 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.. Sqm 587 N 0
128 PWD PWD BUILDING 2015 Providing and laying ceramic glazed floor tiles conforming to IS : 15622of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size 300x300mm Sqm 692 N 0
129 PWD PWD BUILDING 2015 21.2.1.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 150 mm dia. Metre. 371 N 0
130 PWD PWD BUILDING 2015 21.2.2.3 Rocky strata including Boulders. 150 mm dia. Metre. 424 N 0
131 PWD PWD BUILDING 2015 21.3.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. Metre. 540 N 0
132 PWD PWD BUILDING 2015 21.6.3 Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part- 1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-incharge 150 mm nominal dia Metre. 1317 N 0
133 PWD PWD BUILDING 2015 Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 1048 0 N 0
134 PWD PWD BUILDING 2015 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) Point 1502 N 0
135 PWD PWD BUILDING 2015 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). Cum 201 0 N 0
136 PWD PWD BUILDING 2015 22.3 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). Cum 248 N 0
137 PWD PWD BUILDING 2015 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). Cum 236 N 0
138 PWD PWD BUILDING 2015 22.7 Fine dressing the ground sqm 1098 0 N 0
139 PWD PWD BUILDING 2015 22.9 Mixing earth and sludge or manure in proportion specified or directed. Cum 11 N 0
140 PWD PWD BUILDING 2015 22.25.1 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hedges like Alife, Dorenta, Tikoma etc each 14 N 0
141 PWD PWD BUILDING 2015 22.25.2 Furn like Arica, China etc (3 year old) each 125 N 0
142 PWD PWD BUILDING 2015 22.25.3 Hibiscus (Flower)/ Rose each 26.5 N 0
143 PWD PWD BUILDING 2015 22.25.4 Carpet grass (well developed) each 263 N 0
114 PWD ELECT 2020 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point Point 266 0 N 0
115 PWD ELECT 2020 1.7.2 Medium Point Point 424 0 N 0
116 PWD ELECT 2020 1.7.3 Long Point Point 588 0 N 0
117 PWD ELECT 2020 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 420 0 N 0
118 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 216 0 N 0
119 PWD ELECT 2020 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point Point 442 0 N 0
120 PWD ELECT 2020 1.10.2 Medium Point Point 659 0 N 0
121 PWD ELECT 2020 1.10.3 Long Point Point 922 0 N 0
122 PWD ELECT 2020 1.10.4 Extra Long Point I Point 1302 0 N 0
123 PWD ELECT 2020 1.10.5 Extra Long Point II Point 1657 0 N 0
124 PWD ELECT 2020 1.10.6 Extra Long Point III Point 1995 0 N 0
125 PWD ELECT 2020 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point Point 589 0 N 0
126 PWD ELECT 2020 1.11.2 Medium Point Point 942 0 N 0
127 PWD ELECT 2020 1.11.3 Long Point Point 1350 0 N 0
128 PWD ELECT 2020 1.11.4 Extra Long Point I Point 1807 0 N 0
129 PWD ELECT 2020 1.11.5 Extra Long Point II Point 2315 0 N 0
130 PWD ELECT 2020 1.11.6 Extra Long Point III Point 2825 0 N 0
131 PWD ELECT 2020 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit Metre 92 0 N 0
132 PWD ELECT 2020 1.13.2 3 x 2.5 sqmm in 20mm conduit Meter 111 0 N 0
133 PWD ELECT 2020 1.13.3 6 x 2.5 sqmm in 25mm conduit Meter 172 0 N 0
134 PWD ELECT 2020 1.13.4 9 x 2.5 sqmm in 32mm conduit Meter 238 0 N 0
135 PWD ELECT 2020 1.13.5 12 x 2.5 sqmm in 32mm conduit Meter 288 0 N 0
136 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 223 0 N 0
137 PWD ELECT 2020 5.4.22 Batten/ angle holder Each 41 0 N 0
138 PWD ELECT 2020 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe Each 107 0 N 0
139 PWD ELECT 2020 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. Each 42 0 N 0
140 PWD ELECT 2020 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep Each 1697 0 N 0
141 PWD ELECT 2020 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 31 0 N 0
142 PWD ELECT 2020 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan) Each 56 0 N 0
143 PWD ELECT 2020 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep Each 2446 0 N 0
144 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.4 36 watt {4 feet} Each 718 0 N 0
145 PWD ELECT 2020 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.4 9 Watt Each 143 0 N 0
146 PWD ELECT 2020 6.17.5 12 Watt Each 215 0 N 0
147 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.8 90 watt Each 5531 0 N 0
148 PWD ELECT 2020 6.28.9 120 watt Each 6844 0 N 0
149 PWD ELECT 2020 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm) Metre 717 0 N 0
150 PWD ELECT 2020 7.20.2 200 amp (30x5mm) Metre 907 0 N 0
151 PWD ELECT 2020 7.20.4 400 amp (50x6mm) Metre 1531 0 N 0
152 PWD ELECT 2020 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep sqm 6818 0 N 0
153 PWD ELECT 2020 7.19.2 Above 300 mm and upto 450 mm deep sqm 7525 0 N 0
154 PWD ELECT 2020 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.4 3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA Each 3734 0 N 0
155 PWD ELECT 2020 9.1.9 3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA Each 12006 0 N 0
156 PWD ELECT 2020 9.1.36 4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA Each 20356 0 N 0
157 PWD ELECT 2020 9.8 Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 9.8.5 4 way (4 + 12), Double door Each 5904 0 N 0
158 PWD ELECT 2020 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps Each 148 0 N 0
159 PWD ELECT 2020 9.20 Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 40 amps Each 568 0 N 0
160 PWD ELECT 2020 9.20.2 63 amps Each 621 0 N 0
161 PWD ELECT 2020 Providing and fixing metal clad, 4 pole, on load change over switch unit (without sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 10.6.5 400 amps Each 21184 0 N 0
162 PWD ELECT 2020 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.3 200/5 amps Each 347 0 N 0
163 PWD ELECT 2020 10.15.6 500/5 amps Each 361 0 N 0
164 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 94 0 N 0
165 PWD ELECT 2020 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. Each 1201 0 N 0
166 PWD ELECT 2020 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound. Each 10955 0 N 0
167 PWD ELECT 2020 12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound. Each 8222 0 N 0
168 PWD ELECT 2020 12.5 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 513 0 N 0
169 PWD ELECT 2020 12.17 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification. Metre 38 0 N 0
170 PWD ELECT 2020 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate having 4 nos holes for fixing etc. complete as per specification. Each 767 0 N 0
171 PWD ELECT 2020 Making jointing of copper tape (with another copper tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as per specification. Each 51 0 N 0
172 PWD ELECT 2020 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For horizontal run) Metre 217 0 N 0
173 PWD ELECT 2020 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For vertical run) Metre 219 0 N 0
174 PWD ELECT 2020 Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as per specification. Each 93 0 N 0
175 PWD ELECT 2020 Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as per specification. Metre 654 0 N 0
176 PWD ELECT 2020 14.1 Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.1 63 mm outer dia and 50 mm Inner dia Metre 184 0 N 0
177 PWD ELECT 2020 14.1.3 90 mm outer dia and 75 mm Inner dia Metre 203 0 N 0
178 PWD ELECT 2020 15.1 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.1.14 3.5 x 70 sq. mm. Metre 451 0 N 0
179 PWD ELECT 2020 15.1.16 3.5 x 120 sq. mm. Metre 544 0 N 0
180 PWD ELECT 2020 15.1.19 3.5 x 240 sq. mm. Metre 955 0 N 0
181 PWD ELECT 2020 15.1.22 4 x 10 sq. mm. Metre 293 0 N 0
182 PWD ELECT 2020 15.1.23 4 x 16 sq. mm. Metre 300 0 N 0
183 PWD ELECT 2020 15.1.24 4 x 25 sq. mm. Metre 321 0 N 0
184 PWD ELECT 2020 15.5 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.5.14 4 x 16 sq. mm. Metre 126 0 N 0
185 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.15 3½ X 70 sq. mm (35 mm) Each 199 0 N 0
186 PWD ELECT 2020 15.23.17 3½ X 120 sq. mm (45 mm) Each 283 0 N 0
187 PWD ELECT 2020 15.23.20 3½ X 240 sq. mm (57 mm) Each 504 0 N 0
188 PWD ELECT 2020 15.23.23 4 X 10 sq. mm (22 mm) Each 98 0 N 0
189 PWD ELECT 2020 15.23.24 4 X 16 sq. mm (22 mm) Each 101 0 N 0
190 PWD ELECT 2020 15.23.25 4 X 25 sq. mm (25 mm) Each 104 0 N 0
191 PWD ELECT 2020 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.7.3 8 metre high, dia 135mm at bottom and 90mm at top, base plate size 225x225x16mm, foundation bolts 750mm long Each 11853 0 N 0
192 PWD ELECT 2020 19.4 Supply of GI PIPE POLE made of "B" class GI pipe making necessary hole for cable entry and providing earthing stud (welded at specified height) including painting with one coat of red oxide zinc chromate primer. 19.4.1 50 mm dia Metre 398 0 N 0
193 PWD ELECT 2020 19.4.2 65 mm dia Metre 498 0 N 0
194 PWD ELECT 2020 19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. 19.9.2 Single Over Hang 1.00 metre Long Each 1057 0 N 0
195 PWD ELECT 2020 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 19.11.6 8 metre high Each 924 0 N 0
196 PWD ELECT 2020 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification. cum 5219 0 N 0
197 PWD ELECT 2020 30.2 Earth work in soft rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification cum 210 0 N 0
TOTAL RS. 45198250
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
1574246693372354433_181809_List of Approved Material (2).pdf
NIT • 0.15 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
3668348693445483439_181809_NIT.doc
NIT • 0.28 MB
8095864970502597239_181809_Annexure -E.pdf
NIT • 0.21 MB
8357551260710208275_181809_Form A.doc
NIT • 0.17 MB
6025370263889620909_186030_186030 Notice.doc
NIT • 0.08 MB
9095120713975894709_181809_BOQ.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid