Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 271 CIVIL LINE GURUGRAM GURUGRAM GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.0 L
EMD Value
₹11,980
Closing Date
10 Feb 2020, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please reffer BOQ
2020_PWDJK_91443_1
e-NIT No. EDJ/233 of 2019-20 Dated 28-01-2020
Open Tender
Electrical Works
Item Rate
20 days
Bikram Chowk Jammu
please reffer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹11,980
Yes
14 Feb 2020
28 Jan 2020
11 Feb 2020
29 Jan 2020
10 Feb 2020
29 Jan 2020
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
6 way (4 + 12), Double door
8 way (4 + 24), Double door
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover. along with providing and laying of 25 x 5 mm copper strip from copper rod up-to the main panel.
Fabrication, supplying, installation testing and commissioning of main pannel made out of 2mm thick M.S sheet, floor mounted, vermin and dust proof, indoor/Outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors duly painted, with provision of space for fixing of incomer FP MCCB's, and allied accessories etc. as required.
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. All MCCB's shall be adjustable type and shall have rotary handle ICU=ICS =100%.
MCCB FP 200 amp. 36 KA
MCCB FP 250 amp. 36 KA
MCCB FP 400 amp. 50 KA
MCCB FP 100 amp. 16 KA
400 A FP ON load Change Over
Aluminium Bus Bar 1000 Amp Set of 4 strips.
Aluminium Bus Bar 500 Amp Set of 4 strips.
CT Set of suitable rating
Indicating Lamp
MCB Strip for 12 Nos. MCB's
Digital MFM class 1.0 depicting VAF METERS and of suitable rating.
Supply , Installation, Testing and commissioning of Automatic Power Factor Correction Panel Indoor type in IP42 protection, floor standing, fabricated of 2mm thick CRCA sheet , duly powder coated . The panel shall be suitable for operation on 415 Volts , 50Hz, 3 phase system with TPN Aluminium busbar of 400Amps, The Capacitors and Switchgears shall be arranged in a modular arrangement duly comprmentalised. Panel shall be complete with earthing arrangement. Incomer : 160 A 3 pole MCCB Ics= 25kA - 1 no. One Set of Indications using LED type indicators Busbar : Shall be of TPN Alluminium rated for 500Amps with heat shrinkable sleeves and mounted on DMC supports Outgoing : 40 Amps 3pole MCCB Ics=25kA - 12 no. Capacitor Switching Duty Contactors of following ratings 20kVAr - 1 Nos., 10 kVAr - 5 Nos, 5kVAR - 6 Nos Heavy Duty Resin Filled Capacitors 3 Phase shall have following configuration 20kVAR X 1 + 10kVAR X 5 + 5kVAR x 6 APFC Relay of 12 stage shall be used Material Used shall be of list of makes enclosed Shop Drawings to be got approved before manufacturing
Supplying & laying PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling of trench etc. as required.
25 Sq.mm 3.5 Core Un-armoured
70 Sq.mm 3.5 Core Un-Armoured
150 Sq.mm 3.5 Core Armoured
400 Sq.mm 3.5 Core Armoured
GLOBAL ENGINEERS
SV ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .