| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹16.8 L+₹1.6 L (10.8%)Rejected-Finance 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.9 L+₹1.7 L (11.2%)Rejected-Finance 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹18.0 L+₹2.8 L (18.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹18.7 L+₹3.5 L (23.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
Repair/ Maint/ LT pole Electrical Distribution System and allied works at Technical and Domestric area19 Wing and 14BRD under GE (AF) Borjhar
2020_MES_365618_1
8762/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹50,000
Yes
20 Oct 2020
31 Jul 2020
31 Aug 2020
31 Jul 2020
29 Aug 2020
17 Aug 2020
60 days
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding1.5 mtr in depth for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed.
Taking down of unserviceable under ground old LT Cable of any size complete all as directed
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of cross sectional area 70 Sqmm 3.5 core complete all as specified and as directed.
All as per item No.3.00 herein before but of size 95 Sqmm x 3.5 core complete all as specified and as directed.
All as per item No.3.00 herein before but of size 185 Sqmm x 3.5 core complete all as specified and as directed.
All as per item No.3.00 herein before but of size 400 Sqmm x 3.5 core complete all as specified and as directed.
M&L for fine sand (River sand) spread in trenches for cushioning of cable 8cm thick under the cable and 15cm over the cable and punned down gently to 18 cm for protection complete all as specified and as directed.by Engineer–in-charge. Note :- Compacted thickness shall be measured and paid
M&L for brick protection with sub-class ‘B’ bricks laid dry flat (23cm width) cross the cable for protection to cable after sand cushioning complete all as directed by Engineer-in-Charge.
M&L for 50 mm bore mild steel galvanised iron pipe, light grade laid in trenches or fixed to wall/along the pole for protection of cable as in repair complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick each layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.by Engineer –in-charge.
Relaying of old serviceable brick after carrying out repair, cleaning the surface complete all as directed by Engineer-in-Charge. Note : - Seviceable brick obatined from ser item No.2 shall be used.
Relaying of old LT cable of any size/core after carrying out repair such as joining epoxy joint and laid with sand cushioning and brick protection and making connection by using lugs complete all as directed by Engineer-in-Charge. Note : - (i) Seviceable LT cable obatined from ser item No.2 shall be used. (ii) Sand, brick and lugs shall be measured and paid seperately under respective item of schedule.
S & F cable jointing kit for 1100Volt (earthed) grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, 3.5/4 core, fixed in repairs complete all as specified and as directed by Engineer-in -charge.
S & F cable jointing kit for 1100Volt (earthed) grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm, 3.5/4 core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F cable jointing kit for 1100Volt (earthed) grade cable for End termination, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 240 to 400 Sqmm, 3.5/4 core as in repairs complete all as specified and as directed by Engineer-in -charge
S & F cable jointing kit for 1100Volt (earthed) grade cable for End termination , heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, 3.5/4 core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F cable jointing kit for 1100Volt (earthed) grade cable for End termination, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5/4 core as in repairs complete all as specified and as directed by Engineer-in -charge.
Dismantling /taking down old unserviceable LT over head ACSR conductor (weasel ) of any size including separating serviceable conductor and kept in safe custody for re-use in the work and removing unserviceable conductor from site from LT poles/over head electric line after disconnecting from insulators complete all as specified and as directed by Engineer-in-Charge.
S & F aluminium conductor steel reinforced (ACSR) on over head LT electric line with stretching and tensioning the same with required span sag, providing jumper, making bus bar and binding the conductor with pin/shackle insulator and jumpers with aluminium binding wire not less than 2mm dia complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 20.00 herein before but fixing & restring only complete all as specified and as directed. Note : - (i) Seviceable ACSR conductor obatined from ser item No.20 shall be used.
S & F PVC flexible LT OH line separater (ISI marked) of size 10mm dia, tightened properly on LT OH ACSR at 4 span including jointing as in repairs complete all as specified and as directed by Engineer-in -charge.
All as per item No.23.00 herein before but for 3 span
All as per item No.23.00 herein before but for 2 span
M & L for jumpering of two sides of ACSR conductor on over head with same conductor of length 1 mtr and with two nos clamp of suitable size including taking down old unserviceable complete all as specified and as directed by Engineer-in -charge.
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nut and bolt, washers, back plate of any size/shape complete setting aside serviceable cross arms for re-use the work and removing unserviceable cross arms from site complete all as specified and directed.
M&L for cross arms, bracing, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including GI clamp and including of one primer coat, one under coat and one finishing coat of aluminium paint over a coat of red oxide complete all as specified and as directed by Engineer-in-Charge.
Fixing only old serviceable cross arms with providing new bolts, nuts and washers as required including painting with one coat of aluminium paint after preparation of old surface complete all as specified and as directed. Note : - (i) Seviceable cross arms obatined from ser item No. 27 shall be used.
Dismantling old unserviceable bending/ broken steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same from site complete all as specified and directed.
Supply & erecting in truelly vertical position of mild steel tubular swaged poles of 9 meter long, type 410-SP-31, complete with cast iron base plate, goose neck bracket, finial taper plug, bolt, nuts & screws confirming to IS-2713 of 1980 and internal surface painted with black bituminous paint & external surface painted with two coat of aluminium paint over one coat of red oxide primer from top of pole to 1.5 mtr above from top of PCC coping & from top of PCC coping to 1.5 mtr height portion of pole painted with black & white colour paint as in alternate strips complete all as specified and as directed .by Engineer –in-charge. Note :- Size of any colour strips shall be decided by Engineer-in-Charge as per Electricity code of practice.
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation, coping/collar for poles including necessary form work and finished to exposed surface even and fair without using extra cement all as specified and as directed by Engineer-in-charge
M & L for painting to steel tubular LT pole of 9.00 mtr long (effective painted length from top of foundation concrete to top of pole) including cross arms, clamps and M.S brackets surface of any description including removal of old paint with chemical or burning with glow lamp & cleaning to steel surface with sand paper & preparation of steel surface & applying one coat of aluminium paint on pole accessaries like as cross arms, clamp, & bracket etc including marking of pole No of 40mm height in block letters as (MES/BOR/.....) and lower portion of pole painted with one coat of black synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as soecified and directed. Note:- Earth work & excavation shall be measured separately under respective item of schedule.
S & F galvanised stay wire (stay strand) of size 7/4mm with properly tightening the same complete all as specified and as directed by Engineer-in -charge.
M&L for stay assembly with 20mm dia stay rod complete with all accessories as shown in electrical plate No 01 SSR Part-I (2009) with stay rod of 20mm dia complete all as specified and as directed by Engineer-in-Charge.
Dismantling of LT insulators of any type and size from any position including seperating and getting aside serviceable insulator for re-use in the work from site complete all as specified and directed.
S & F for pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 100 mm height 65 mm dia for 1100 volts grade as in repair complete all as specified and as directed by Engineer-in -charge.
All as per item No.37.00 herein before but for fixing only. Note:- Old serviceable pin type insulator obtained from srl item No. 38 shall be used
S & F shackle type pocelain vitreous white, brown or green insulators for working pressure 1100 volt of 90 mm dia and 75 mm height including galvanized mild steel straps of 31x3 mm size, washers, 12 mm dia insulator bolts, nuts & washers including connected to conductor as in repairs as in repairs complete all as specified and as directed by Engineer-in -charge.
All as per item No. 39.00 herein before but for fixing only. Note:- Old serviceable shackle type insulator obtained from srl item No. 40 shall be used
Supply and fixing loop type insulators vitreous, porcelain white, brown or green large size with over all dimensions of 90x140 mm clearance or hole 25.5mm as in repairs complete all as specified and as directed by Engineer-in -charge.
Cutting and trimming of tree branches, bushes n.exc 5 Mtr girth all along LT overhead lines/guard wire and removing branches out of defence land complete all as directed.
S&F change over switch 63 amps 4 pole 415 volt front operated inside the panel with cable connection and accessories after taking down the old unserviceable one complete all as specified and directed . Make Havells Cat No. IHCNFE0063 or equivalent make as sepcified in PS
S&F change over switch 315 amps 4 pole 415 volt front operated inside the panel with cable connection and accessories after taking down the old unserviceable one complete all as specified and directed . Make Havells Cat No. IHCNFE0063 or equivalent make as sepcified in PS
S&F change over switch 250 amps 4 pole 415 volt front operated inside the panel with cable connection and accessories after taking down the old unserviceable one complete all as specified and directed . Make Havells Cat No. IHCNFE0063 or equivalent make as sepcified in PS
Taking Down existing old unserviceable MCCB/Main Switch of 63,100 250 &400Amps from the panel complete all as per directed.
S&F MCCB 400 amps, 4 pole,415 Volt adjustable type with breaking capacity 36 KA complete all as specified and directed. Make : Havells Cat No. IHLLSECF0250 or equivalent make as sepcified in PS
S&F MCCB 250 amps, 4 pole,415 Volt adjustable type with breaking capacity 36 KA complete all as specified and directed. Make : Havells Cat No. IHLLSECF0250 or equivalent make as sepcified in PS
S&F MCCB 200 amps, 4 pole,415 Volt adjustable type with breaking capacity 36 KA complete all as specified and directed. Make : Havells Cat No. IHLLSECFO200 or equivalent make as sepcified in PS
S&F MCCB 160 amps, 4 pole,415 Volt adjustable type with breaking capacity 36 KA complete all as specified and directed. Make : Havells Cat No. IHLCNF0160 or equivalent make as sepcified in PS
S&F MCCB 100 amps, 4 pole,415 Volt fixed type with breaking capacity 16 KA complete all as specified and directed. Make : Havells Cat No. IHLGNF0100 or equivalent make as sepcified in PS
S&F MCCB 63 amps, 4 pole,415 Volt fixed type with breaking capacity 16 KA complete all as specified and directed. Make : Havells Cat No. IHLGNF0063 or equivalent make as sepcified in PS
S&F 1100 votls grade heavy duty cable PVC insulated stranded 10 Sqmm aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular including taking out old existing unserviceable one complete all as specified and directed.
All as per serial item No. 53.00 above but for 6 Sqmm cable
S&F in repair digital type voltmeter 0-500 volt 96x96 mm square type complete all as specified and directed.
S&F in repair digital type ammeter 0-400 amp 96x96 mm square type complete all as specified and directed.
S&F in repair CT 400/5 , copper wounded with suitable wiring for digital type ammeter for 3 phase connection complete all as specified and directed.
Taking out / down faulty serviceable11KV, HT UG cable in existing trenches/duct/on HT poles of nominal cross sectional area from 95 to 185 Sqm, 3 core including disconnecting, PCC covers, GI Pipe etc. of any descriptions, including segregation of serviceable materials viz PCC cable cover, GI Pipes etc. and tracing the location of fault and keep in safe custody for re-use complete all as specified and as directed NOTE : (i) Earth work shall be measured and paid for separately under relevent items (ii) Serviceable cable covers will be kept aside for re-use (iii) Serviceable GI pipe will also be kept aside for re-use
Re-laying of serviceable HT Cable XLPE insulated with aluminium conductor of size from 95 to 185sqmm, 3 core, 11000 volts grade complete all as specified and directed.
Re-laying only old PCC cable cover in Trenches for Under Ground cable protection (Serviceable Materials obtained fron item No. 59 here-in-before), complete all as specified and directed.
Supply, laying, jointing and testing of electric cable, heavy duty 11KV (E) grade, XLPE insulated, screened with sound compacted aluminium conductor, conductor screening with extruded semi-conducting layers insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathing galvanised steel strip armoured PVC (ST-2) outer sheathed cable conforming to IS-7098(Part-II) amended of Nominal cross sectional area of 185 sqmm, 3 core, laid in trenches/cable duct complete all as specified and as directed.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for Straight through 95 sqmm to 185 sqmm 3 core, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core, XLPE armoured aluminium conductor cable including testing etc complete all as sepcified and directed.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for Out door End termination 50 sqmm to 95 sqmm 3 core, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core, XLPE armoured aluminium conductor cable including testing etc complete all as sepcified and directed.
M & L for detecting carefully the fault location of HT UG cable of size 95 sq mm to 185 sq mm 3 core either HT cable fault locator machine or any other method and taking out remove the faulty portion of cable from undergound /over all length respectively inc meggering /connecting/testing on completion all as directed by EIC. Note: (i) Excavation & earth work shall be deem to be included in the unit rate of this item of work.(ii) Stright throught joint for HT cable shall be measured and paid seperatly under respective item of this schedule (iii) Actual detected fault shall be paid under this item. Dummy located trail shall not measured & paid under this item
Supply and fixing in repairs GI pipe light grade 100 mm dia for cable protection incl all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
Supply installtion testing and commissioning weather and vermine proof LT Panel board box out door type (Factory made) and double door with locking arrangement of size 1.4(H) x 1.2(L) x 0.45(D) mtr made out 3.15 mm thick CRCA sheet and support with suitable size of angle complete 600 Amps 4 Nos copper Bus bar iand incoming /outgoing MCCB as below (a) Incomming:-4 Pole MCCB 350 Amp, 50 Hz, 415 V with rupturing capacity 35 KA.- 01no OUTGOING FEEDERS (a) Supply and fix 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA - 1 nos ( b) Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 2 Nos (c ) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 1 no (d) MCCB TPN 63 Amps -01No (e) Ammeter of rating (0-300)A with CTS -01 Set (f) Digital Voltmeter (0- 500v) -01 no(g) R-Y-B LED healthy indication lamp with 03 nos HRC fuse (h) Change over switch ofrating 350 Amps -01 no . All MCCB in Vertical position
Supply installtion testing and commissioning weather and vermine proof LT Panel board box out door type(Factory made) and double door with locking arrangement of size 1.00 (L) x 1.6 (H) x 0.40 mtr made out 3.15 mm thick CRCA sheet and support with suitable size of angle complete 600 Amps 4 Nos copper Bus bar iand incoming /outgoing MCCB as below (a) Incomming:-4 Pole MCCB 150 Amp, 50 Hz, 415 V with rupturing capacity 35 KA.- 01no OUTGOING FEEDERS (a) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 35 KA - 1 nos ( b) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 2 Nos (c ) Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 1 no(d) MCCB TPN 32 Amps -01No (e) Ammeter of rating (0-300)A with CTS -01 Se(f) Digital Voltmeter (0- 500v) -01 no(g) R-Y-B LED healthy indication lamp with 03 nos HRC fuse
Supply and fixing in repair aluminium cable lugs for fixing of armoured cables in panels for 50 Sqmm cables complete all as specified.
All as per item No 72 above but for 70 Sqmm cable
All as per item No 72 above but for 95 Sqmm cable
All as per item No 72 above but for 120 Sqmm cable
All as per item No 72 above but for 150 Sqmm cable
All as per item No 72 above but for 185 Sqmm cable
All as per item No 72 above but for 240 sqmm cable
All as per item No 72 above but for 400 sqmm cable
M & L for Dismantling of Electric connection from the RCC Over head pole and removing the pole from site comple all as directed by Eng-in-charge.
M&L for preparation of old painted body surface of LT indoor/out door panel / feeder piller box and spray painting with two coat of synthetic enamel paint as per existing colour to inside and outside of the body of LT panel as directed by the Engr-in -Charge complete all as specified and directed.
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including 25 x 4 mm GI strip upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm dia GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mm c/c and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed.
D.B ENTERPRISE
M/S PANKAJ SUPPLY SYNDICATE
M.S. Construction
M/s Beekey Seekey Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .