Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.8 LAccepted-AOC OPPOSITE SWAHID BHAWAN VILL MIRZA P O MIRZA DIST KAMRUP 781125 | MIRZA | KAMRUP | ASSAM | 781125 | L1 | Accepted-AOC Awarded cost inclusive of GST and consider as a L1 bidder | |
| 2 | L2₹74.9 L+₹1.3 L (1.81%)Rejected-Finance A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹75.1 L+₹1.6 L (2.17%)Rejected-Finance | L3 | Rejected-Finance L3 Bidder | |
| 4 | L4₹76.0 L+₹2.5 L (3.33%)Rejected-Finance | L4 | Rejected-Finance L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
22 May 2023, 12:00 pmClosed
Chief General Manager PPnD
O/o the MD, AEGCL, Bijulee Bhawan, Paltan Bazar, 1st Floor, Guwahati-01
Turnkey Construction of 1(One) No. of 33kV Kukurmara-Rani Feeder at 400KV Kukurmara (Mirza) GSS, AEGCL
2023_AEGCL_30669_1
AEGCL/MD/Tech-1077/33kV Kukurmara-Rani Feeder
Open Tender
Electrical Works
Turn-key
300 days
Kukurmara(Mirza)
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
₹1.9 L
Yes
26 Jul 2023
2 May 2023
23 May 2023
2 May 2023
22 May 2023
19 May 2023
3 May 2023 - 15 May 2023
Amount
Supply of Equipments and accessories
33kV, 31.5kA, 2000A, Vaccum Gang operated Circuit Breaker complete with mounting structure and all accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 300-500/1-1A, 2-Core Single Phase CT complete with all fittings and all accessories including Terminal connectors (0.2 Class, live tank type).
33 kV 3 Phase PT including all accessories and terminal connectors as required
33kV Lightning Arrester complete with all fittings and all accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing.
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
CRP & SAS
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for existing SAS Integration
LIU-ABB art no: IMYN900010-WC (24 port wall mounted fiber patch panel with STMM pigtails and dapters fully loaded) suitable for integration with existing ABB SAS
OFC cable, 62.5/125.6 core multimode (suitable for connection with LIU-ABB art IMYN900010-WC
ABT compliant energy meter including installation (SAMAST Compliant)
Insulator strings, Clamps & Connectors (UPG, T Etc.)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper)
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium)
a) 2CX6 sqmm
b) 4CX 16sqmm
c) 3 1/2 C X 35 sqmm
60 W LED Lights for Switch Yard Illumination, including Fitting and fixing
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)
Supply of Marshalling Box for CT
Supply of Marshalling Box for PT
Mandatory Spares
For 33kV VCB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e)Complete One No. VCB pole (Spare) compatible to fitting in any phase of the CB
f) Set of all Gaskets along with sealing agents
a) 33 kV,25 kA,1250A isolators female contact (Entire assembly)
b) 33 kV,25 kA,1250A isolators moving contact (Entire blade assembly)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and all accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Clamps & Terminal connectors
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
Supply of Industrial grade AC for Kiosk
Supply and fixinng in position as directed by Engineer in vharge, 3TR AC split type, Mega AC split type, Cenrifugal type compressor, air flow rate of 1000 or above, withBig iron angle whatever required with all accessories including CGBC drain pipe, copper pipe with wire & insulation, control unit etc, along with installation charges
Description of Work / Item(s)
Amount
F&I of Equipments and accessories
33kV, 31.5kA, 2000A, Vaccum Gang operated Circuit Breaker complete with mounting structure and all accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 300-500/1-1A, 2-Core Single Phase CT complete with all fittings and all accessories including Terminal connectors (0.2 Class, live tank type).
33 kV 3 Phase PT including all accessories and terminal connectors as required
33kV Lightning Arrester complete with all fittings and all accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing.(F&I)
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
CRP & SAS(F&I)
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for existing SAS Integration
LIU-ABB art no: IMYN900010-WC (24 port wall mounted fiber patch panel with STMM pigtails and dapters fully loaded) suitable for integration with existing ABB SAS
OFC cable, 62.5/125.6 core multimode (suitable for connection with LIU-ABB art IMYN900010-WC
ABT compliant energy meter including installation (SAMAST Compliant)
Insulator strings, Clamps & Connectors (UPG, T Etc.)(F&I)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments(F&I)
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper)(F&I)
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium) (F&I)
a) 2CX6 sqmm
b) 4CX 16sqmm
c) 3 1/2 C X 35 sqmm
60 W LED Lights for Switch Yard Illumination, including Fitting and fixing(F&I)
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)(F&I)
Supply of Marshalling Box for CT(F&I)
Supply of Marshalling Box for PT(F&I)
Mandatory Spares(F&I)
For 33kV VCB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e)Complete One No. VCB pole (Spare) compatible to fitting in any phase of the CB
f) Set of all Gaskets along with sealing agents
33 kV,25 kA,1250A isolators female contact (Entire assembly)
33 kV,25 kA,1250A isolators moving contact (Entire blade assembly)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and all accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to existing ABB SAS
Clamps & Terminal connectors(F&I)
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
F&I of Industrial grade AC for Kiosk
Supply and fixinng in position as directed by Engineer in vharge, 3TR AC split type, Mega AC split type, Cenrifugal type compressor, air flow rate of 1000 or above, withBig iron angle whatever required with all accessories including CGBC drain pipe, copper pipe with wire & insulation, control unit etc, along with installation charges
Description of Work / Item(s)
Amount
Erection of mounting structure as required, including construction of foundation and supply of all foundation materials and structure earthing including labour cost etc. as required to complete the Job
33kV VCB
33kV Isolator
33kV Post Insulator
Erection, Testing and Commissioning including laying of control cables and equipment earthing as required to complete the job.
33kV SF6 Circuit Breaker/VCB
33kV Isolator
33kV Post Insulator
Installation of earthing system
Installation of earth electrode for LA with test links including construction of covered earth pits.
Construction of extended earth mat using GI flats and connection to risers for equipment earthing as directed.
Construction of cable trench & slab, supply of all foundation materials, structure and earthing including labour cost etc. as required to complete the Job
a) D Type
Switchyard PCC and Gravelling
Providing 80mm thick PCC base in prop 1:4:8 as per drawing & specifications including supply of all materials and labour.
Providing switchyard gravelling (100mm thickness) levelling etc as per directive of site engineer.
Installation and commissioning of the C&R panel
Installation in KIOSK, including testing and commissioning of C&R panel.
Integration of C&R panel into existing SAS of ABB Make including Testing and commissioning
Installation of Industrial gradeAC in 33kV Kukurmara-Rani feeder
Supply and fixinng in position as directed by Engineer in vharge, 3TR AC split type, Mega AC split type, Cenrifugal type compressor, air flow rate of 1000 or above, withBig iron angle whatever required with all accessories including CGBC drain pipe, copper pipe with wire & insulation, control unit etc, along with installation charges
POWER NETWORK ENGINEERS PRIVATE LTD
P & S CONSTRUCTION
HABI INFRASTRUCTURE
HABI INFRASTRUCTURE
Everlite Engineering Industries
POWER NETWORK ENGINEERS PRIVATE LTD
POWER NETWORK ENGINEERS PRIVATE LTD
P & S CONSTRUCTION
Everlite Engineering Industries
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .