Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹43.1 L+₹1.3 L (3.03%)Rejected-Finance BHANGARMATH THAKURANICHAWK PO SAMABAYPALLY BALLY HOWRAH 711205 | HOWRAH | HOWRAH | WEST BENGAL | 711205 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹43.2 L+₹1.3 L (3.12%)Rejected-Finance 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.4 L+₹1.5 L (3.65%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹43.6 L+₹1.8 L (4.24%)Rejected-Finance 20 1 B M BANERJEE ROAD BELGHARIA KOLKATA 700056 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
14 Mar 2024, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINTENANCE OF MISC B/R AND E/M WORKS IN AC INSTALLATIONS AND OTHER ALLIED WORKS INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_643985_1
8225/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
Yes
30 Mar 2024
24 Feb 2024
15 Mar 2024
24 Feb 2024
14 Mar 2024
8 Mar 2024
Amount
B/R PORTION
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard and dense soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) not exc 15cm thick in ground floor and paving (below or above ground level) complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M & L PCC 1:2:4 type B-2 using 20 mm graded stone aggregate as in surface channels and drains etc complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed.
M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed.
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender)
M&L for sand filling under floors or in foundation including watering and consolidation all as directed by engr in charge
S&F machine made precast cement concrete blocks M 35 (interlocking paves) of 60mm thick with 6mm top layers of colour rubrised ante abrasive material laid over sand cushion . The interlocking joints shall be filled with fine sand complete all as specified and as directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds mitered or stopped ends etc. complete all as specified and directed.
Dismantling of 100mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed by the Engineer-in-Charge.
Dismantling of 150 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed by the Engineer-in-Charge.
S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed (Note : Earthwork to be measured and paid separately).
S&F 150 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on floor complete all as specified and directed (Note : Earthwork to be measured and paid separately).
S&F in repair 100mm CI bends (any radius),diminishing pieces or tapers (larger bore measured) any radius complete all as specified and directed
S&F in repair 100mm CI bends (any radius),diminishing pieces or tapers (larger bore measured) any radius with oval access doors complete all as specified and directed
S&F in repair 100mm CI Tee equal size any radius with eye complete all as complete all as specified and directed
S&F in repair 100mm CI Tee equal size any radius with with oval access doors complete all as specified and directed
S&F in repair 100mm CI cowl any radius complete all as specified and directed
S&F in repair 150mm CI bends any radius complete all as specified and directed
S&F in repair 150mm CI Tee equal size any radius complete all as specified and directed
S & F in repair PVC (SWR) pipe 75 mm bore single socketed in any length with rubber ring, fixed on wall complete all as specified and directed.
S & F in repair PVC (SWR) pipe 110 mm bore single socketed in any length with rubber ring, fixed on wall complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finished smooth and reforming benching for 100mm bore pipe as required and as directed.
S & F as in repair RCPC (Reinforced Cement Polymer Concrete) grating slab on size 600mmX450mmX75mm thick fixed in proper position complete all as directed.
Taking down cement plaster on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @200 ml/Bags finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separately.)
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement).
M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement with and including taking down cement or lime plaster of any description complete all as specified and directed .
Supplying Integral water proofing compound.
M&L for application of damp proof painting in two layers as per manufacturers instruction in wall and ceiling surface including preparation of surface (by brooming down or steel wire brushung, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
M&L for 15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surface and finished even and smooth without using extra cement including necessary scaffolding work all as specified and directed.
M & L two coat of oil bound distemper on newly plastered surface of wall, by brush and roller including over of one coat white chalk over 1-2 mm thick wall care putty on wall complete all as directed.
M/L for complete removal of existing treatment, washing, rubbing down and stopping of painted/treated surfaces and applying two coat of oil bound distemper by brush and roller including over one coat of chalk whitening over 1-2 mm thick wall care putty on wall complete all as directed.
M&L for applying two coats of oil bound distemper to old decorated surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
M&L for applying two coats of oil bound distemper to new surfaces of ceiling including preparation of surface complete all as specified and directed.
M & L Preparation of new plastered surfaces of walls and soffits of Chajja, roof slab etc and applying two coat of weather proof exterior emulsion paint of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for building height complete all as specified and directed.
M & L applying one coats of synthetic enamel paint on old painted surface wooden surfaces of any description over 10 cm width or girth complete all as specified and directed.
M & L preparation applying one coats of synthetic enamel paint on old steel surface of any description over 10 cm width or girth complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete.
M & L applying two coats of synthetic enamel paint on steel surfaces of any description/new over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and as directed.
S &F in repair framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framework of water tanks and similar work conforming to Fe.290 Gde E-165 complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L non skid ceramic colour tiles of area of each tile exc .11 Sqm but n exc exc .18 Sqm and 6 to 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M & L glazed ceramic colour tiles size 450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match including10 mm thick rendering of mortar as in backing coat of tiles on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed.
M & L 18 to 20 mm thick machine cut Kota stone slab flooring ,stair case step etc over screed bed base ,laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M & L 18 to 20 mm thick machine cut Kota stone in riser of steps, skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing with & including 10 mm thick rendering in cement mortar 1:6 complete all as specified and directed.
Taking up/down plants or vegetation growth wall upto roof level by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 Sqm cm superfical area and not exc one brick depth) using bricks bats / aggregate and plastering in cement mortar (1:4) to distributed portion and applying two coat of cement base paint to match the existing surfaces up to forth floor complete all as specified and directed.
Demolition of cement Concrete(reinforcement cut as required to facilitate demolition) Roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and as directed.
M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and columns in floor, roof landing,, balconies, conopies, deck slab and shelves etc complete all as specified and directed.
Use and waste of formwork to sides and soffits of suspended slabs, floor slab, landing and similar work n. exc. 200 mm thick rough finished surfaces of concrete complete all as specified and directed.
S & F mild steel deformed bar 8 to 10 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Dismantling wrought/mild steel iron work of any description complete all as specified and as directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed.
S&F Framed work Fe-410-W(Gde-E-250) quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening all as specified.
Dismantling of plain or corrugated sheeting , any gauge, thickness and including Naintital or similar pattern roof coverings complete all as specified and directed.
S & F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etc fixed with self tapping screws complete all as specified and as directed.
S&F 1.0 mm thick laths Steel rolling shutters, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type all as specified
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
S&F Ball bearing for rolling shutters complete all as specified and as directed.
Dismantling of wall and ceiling board (fiber pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
M&L False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodized main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with supporting hangar consisting of 6 mm dia mild steel rod, J bolts with necessary bolts and washers and anodised adjuster and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces complete complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board).
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelim PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
Taking down chowkhats or frames not exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame) complete all as specified and directed.
S&F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed .
Cutting holes in to brick wall for inserting bold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, exe half brick but not exe 1 brick. Complete all as specified and as directed.
S & F mild steel work holdfast, cleat etc. for door frame/ wooden batten etc. quality conforming to Fe-290 Gde-E-165 complete all as specified and as directed..
S&F 35 mm thickness 2nd class hard wood factory made Plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F, Powder coated aluminium sliding window with shutter styles 40mm x20 mm sheet thickness 1.5mm Two shutter of glass and one shutter of wire mesh consisting of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100mm x 44mm x 1.5mm thick section with or without rebate 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge. Note: 1) Size of window shall be as per site requirement. 2) Glass and wire cloth shall be measured separately.
S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S & F 4 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified and directed.
S & F 4 mm thick Frosted plain glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
S & F aluminium handles 150 mm long cast type, anodised complete all as specified and directed.
S&F aluminium anodised barrel tower bolts 150 mm long of extruded section and fixed complete all as specified and directed.
S & F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed.
Supply and fixing stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed.
Supply and fixing in repair stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed.
Demolition of cement concrete (un-reinforced) not exc and out compete existing roof treatment from roof surface & roughening of old concrete floor surfaces including cleaning the roof surfaces by brushing sweeping etc and removing rubbish material complete all as specified and directed.
M & L for rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1: 4 under APP membrane finish rendering surfaces even and smooth with out using extra cement mixed with WPC @2% by weight of cement or as per manufacturer instruction. Complete all as specified and directed (Note:- WPC shall be measured and paid separately)
M&L for providing 25mm thick PCC (1:2:4) type 'B-0' (using 12.5mm graded crushed stone aggregate) after applying cement slurry @ 3 Kg/sqm, on top of roof, mixed with water proofing compound @ 200 ml per bag of cement, surface finished even and smooth without using extra cement including complete all as a specified and as directed.
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as a specified and as directed..
M & L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as a specified and as directed.
M & L for for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:- (a) Preparing and clening of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
Supply and fixing in repair vitreous China white coloured flat back urinal half stall, including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and providing grating and union for discharge pipe including 32mm bore PVC discharge pipe complete all as specified and as directed.
S & F in repairs vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed.
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve and handle including bracket and flush pipe complete all as specified and directed.
S&F in repairs vitreous china (coloured) wash down water closet pan (pedestal pattern) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
E/M PORTION
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
M & L for concealed type point wiring with 1.50 sqmm (nominal area) FRLSH insulated and unsheathed muld stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/celling including muld steel terminal boxes 1.25 mm thick conforming to IS - 5133(Part -I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked ) for mounting switches/ regulator / bell push etc including 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point / bell point/ ceiling fan / exhaust fan point controlled by one way switch complete all as specified and directed.
(a) One light/fan point controlled by one switch
(b) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
(c) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No 104 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green copper conductor as continuous earth wire with lugs complete all as specified and directed.
S & F Modular Switch 1 way 6 A, 1 module. Make complete all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module. complete all as specified and directed.
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module. Complete all as specified and directed.
S & F Bell , AC, 230 Volts, single pole. Complete all as specified and directed.
S & F in repair Fan step regulator, 120 watt, 2 module. complete all as specified and directed.
S & F Modular Bell push 6A, 1 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module. Complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module. Complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module. complete all as specified and directed.
S & F Modular type Metal Flush box 6 module. complete all as specified and directed.
S & F Modular type Metal Flush box 8 module. Make : LEGRAND(MYRIUS) /CRABTREE(THAMES)/ GOLD METAL.
S & F Modular type Metal Flush box 12 module. Complete all as specified and directed.
S&F Ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M & L for sub main wiring Concealed type with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including concealed PVC conduit of size 25 mm including smooth the disturbed surface complete all as specified and directed.
All as per Srl. Item No. 129 above but with 2 run of 6.0 Sqmm cable with 6.0 Sqmm as earth continuity conductor.
All as per Srl. Item No. 129 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth
Taking down of Old MCB DB any type any size including MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with 200 amps rated bus bar Make :- Legrand /Havells / L & T
S & F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with 200 amps rated bus bar Make :- Legrand /Havells / L & T
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar Make :- Legrand /Havells / L & T
S & F TP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way double door DB LL 4W DD VERT W/O MCCB. Make :Legrand /Havells / L & T
S & F MCCBs 415V, 16KA, 4 Pole 100Amps.Make : Legrand /Havells / L & T
S & F in repair MCB Four pole, 415 volts, 63 Amps, breaking capacity 10KA Cat No 408702, make: Legrand /Havells /L&T
S & F in repair MCB 'C' series single pole and Neural 32 Amps, breaking capacity 10KA, Cat No 408587-95, make: Legrand /Havells / L & T
S & F in repair MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA, Cat No 408587-95, make: Legrand /Havells / L & T
S&F GI in repair tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified.
Taking down & refixing & connecting electric meters up to 40 amps 1 phase/ 3 phase including tightening of all contact points.
S & Fin repair LED Ceiling light fitting 35/36 W recess type as in repair, minimum colour temperature 6500K, with suitable driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make: Crompton LCTLSN-36-CDL or equivalent make in Baja/Havells
Fixing only LED lights fitting any type with driver, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F in repair AC short circuit protection motor starter 20 Amps capacity AC 230 Volt Make : North West/Crabtree(4module + 2 module = 6 module requirement at site)
Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed.
Taking down for servicing of split type AC 2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quantity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quantity complete all as specified and directed.
Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quantity complete all as specified and directed.
Supply and fix in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specified and directed.
S&F Foam insulation for copper tubing of size 3/4'' dia complete all as specified and directed.
Supply and fixed in repairs of suction valve size 1/2" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 1/4" complete all as specified and directed.
Supply and fixed in repairs of suction valve size 5/8" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 3/8" complete all as specified and directed.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. Note :- Charging of gas refrigerant will be paid and measured separately
All as per item No168 above here in before but 2 TR capacity reciprocating compressor
All as per item No 168 above here in before but 1.5 TR capacity rotary type
All as per item No 168 above here in before but 2 TR capacity rotary compressor
S&F Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
Supply and fix power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed:-
Supply and fix power contactor 3 pole, coil voltage 415 Volts of capacity32 Amps Complete all as specified and as directed:-
Supply and Fix Timer single phase analogue type 230 volts complete all as specified and directed.
Supply and fix remote control hand set for 2.0TR capacity split AC complete all as specified and as directed.
Supply and fix remote control hand set for 1.5TR capacity split AC complete all as specified and as directed.
Supply and fix remote control hand set make suitable for 2.0TR capacity window type AC complete all as specified and as directed.
Supply and fix remote control hand set suitable for 1.5 TR capacity window type AC complete all as specified and as directed.
Dismantling and Re installation including commissioning of VRF Units (Indoor Unit with copper pipe line with drain pipe)including materials such as Copper Pipe, Installation, Hanging supporting materials etc)including checking whole system leakage Testing for nitrogen.(Supply of Oxygen, LPG & Nitrogen) also supply of refrigerant for complete functioning of VRF units including vibration damper at basement complete all as specified and as directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
DUTTA & DUTTA
S.K. TRADERS
MS AP CONSTRUTION AND CO
GOODWILL AND CO.
JAGATMATA ENTERPRISE
DEB AND COMPANY
M A ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .