Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Lowest tender | |
| 2 | L2₹15.4 L+₹61,840 (4.19%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹21.8 L
EMD Value
₹43,500
Closing Date
12 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIRS/ MAINTENANCE TO SUMMER APPLIANCES, VOLTAGE STABILIZERS, CENTRAL HEATING SYSTEM AND CONNECTED WORKS AT AF STN THOISE UNDER GE (AF) THOISE
2023_MES_610301_1
GEAF/T-35/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
As per tender document
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹43,500
Yes
30 Sept 2023
22 Jul 2023
14 Aug 2023
22 Jul 2023
12 Aug 2023
24 Jul 2023
Amount
M&L for taking down the Split Type AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks complete all as specified and as directed by Engr-in-Charge:- (a) Removal of dust from the outer body with the help of a blower. (b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling it. (c) Cleaning the base tray (d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent. (e) Cleaning of indoor unit with a soft, dry cotton cloth. (f) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker. (k) Refixing all items and making it serviceable. Note: All new parts shall be measured and paid separately.
M&L for Charging of refrigerant Gas R-32 in split type Air conditioner (All weather) of capacity 1.5/2 Ton after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas complete all as specified and as directed by Engr-in-Charge.
Taking out old unserviceable compressor from split type Air Conditioner (All weather) of capacity 2 TR and supply,& fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site complete all as specified and as directed by Engr-in-Charge. Make:- Voltas/ carrier/ LG/Videocon)
Taking out old unserviceable compressor from split type Air Conditioner (All weather) of capacity 1.5 TR and supply,& fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site complete all as specified and as directed by Engr-in-Charge. Make:- Voltas/ carrier/ LG/Videocon)
S&F in repairs fan blade suitable for 1.5/ 2.00 Ton split AC complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in replacement of outdoor unit fan motor single phase AC supply 230 volts 50 HZ for split type AC (All weather) 1.5 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of outdoor unit fan motor single phase AC supply 230 volts 50 HZ for split type AC (All weather) 2.0 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of suction valve spring loaded type for split type AC 1.5 TR complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of discharge valve for split type AC 1.5 TR complete all as specified and as directed by Engr-in-Charge.
S& F in replacement of PCB with remote control for Split type AC (All weather) of cap 1.5/2 TR as per existing make complete all as specified and directed by Engr-in-Charge.
Taking down old cracked UNSV copper pipe split line and refixing with new insulated copper split line pipe 50mm dully connected with end of indoor and outdoor unit with suitable nut, bolts or weld as required on site for split type airconditioner complete all as specified and directed by Engr-in-charge.
M&L for taking down Window type AC unit of any capacity by disconnecting all electrical connections and performing following maintenance tasks complete all as specified and as directed by Engr-in-Charge:- (a) Removal of dust from the outer body with the help of a blower. (b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling it. (c) Cleaning the base tray (d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent. (e) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker. (f) Refixing all items and making it serviceable. Note: All new parts shall be measured and paid separately.
M&L for Charging of refrigerant Gas R-32 in window type Air conditioner (All weather) of capacity 1.5/2.0 Ton after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas complete all as specified and as directed by Engr-in-Charge.
Taking out old unserviceable compressor from window type Air Conditioner of capacity 1.5 TR and supply, fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site complete all as specified and as directed by Engr-in-Charge. Make:- Voltas/ carrier/ LG/Videocon)
Supply & fixing in replacement of condensor fan motor single phase AC supply 230 volts 50 HZ for window type AC 1.5 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
Supply and replacement of spares parts of window type and split type AC (All weather) 1.5 TR as under complete all as specified and directed by Engr-in-Charge:-
Starting relay.
Overload protector.
Starting capacitor 120/150 mfd.
Running capacitor 6 mfd.
Running capacitor 45 mfd.
Thermostat.
S& F in replacement of PCB with remote control for window type AC (All weather) of cap 1.5 TR as per existing make complete all as specified and directed by Engr-in-Charge.
S & F in repairs condensor unit complete suitable for 1.5/2 TR split type AC including removing the old condensor unit complete all as specified and directed by Engr-in-Charge.
S & F bracket suitable for 1.5/2 TR split type AC complete all as specified and directed by Engr-in-Charge.
M&L for Taking out old unserviceable compressor from Deepfreezer/upright chiller/freezer of any type of any size and supply & fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site complete all as specified and directed by Engr-in-Charge.
M & L for charging including cleaning the refrigeration system Deepfreezer/ upright chiller/freezer, flushing through with CO2/N2 removal of complete dirt, brazing the line , pressure testing , rectifiation of leakages , dehydrating , vacumising , charging of R134A gas, replacement of copper pipes , copper strainer , topping up compressor oil complete all as specified and directed by Engr-in-Charge.
S &F in repairs overload protector suitable for refrigerator/ Deep freezer of any capacity as per existing model complete all as specified and directed by Engr-in-Charge.
S &F in repairs thermostatic switch suitable for deepfreezer/Refrigerator any type any capacity complete all as specified and directed by Engr-in-Charge.
M & L for disconnecting of electric connection from ceiling rose and taking down the ceiling rose and taking down the ceiling /exhaust fan any type sweep for carrying out repairs /rewinding replacement / cleaning etc and refixing the same in position after repairs including fixing / labour only for replacement of unserviceable parts complete all as specified and directed by Engr-in-Charge. Note: The new parts shall be measured and paid separately except for twin twisted copper wire connecting upto ceiling Rose, Connector and shackle where required.
M&L for Rewinding of ceiling fan 1200mm sweep single phase 230 volts, 50 c/s any make and type with appropriate gauge super enameled copper winding wire with allied insulation winding material, varnishing with air drying insulation varnish including fixing of any item found damaged/unserviceable i.e capacitor of appropriate cap, rubber pads etc and testing complete after rewinding and assembling complete all as specified and directed by Engr-in-Charge. Note: Capacitor, rubber pads, etc if any replaced, shall be measured separately under respective items.
M&L for Rewinding of exhaust fan single phase 230 volts, 50 c/s 450 mm sweep, any make and type with appropriate gauge super enameled copper winding wire with allied insulation winding material, varnishing with air drying insulation varnish including fixing of any item found damaged/unserviceable i.e capacitor of appropriate cap, rubber pads etc and testing complete after rewinding and assembling complete all as specified and directed by Engr-in-Charge. Note: Capacitor, rubber pads, etc if any replaced, shall be measured separately under respective items.
All as per BOQ srl item No 26.00 above but for exhaust fan of size 300mm sweep complete all as specified and directed by Engr-in-Charge.
S &F ball bearing suitable for exhaust fan 450mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/Schaeffler India Ltd
S &F ball bearing suitable for exhaust fan 300mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/Schaeffler India Ltd
S &F ball bearing suitable for ceiling fan 1200mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/Schaeffler India Ltd
S & F in replacement capacitor 4.0 mfd 50 c/s oil filled complete all as specified and directed by Engr-in-Charge. Make: Usha/Universal/Havells
S & F in replacement capacitor 2.5 mfd 50 c/s oil filled complete all as specified and directed by Engr-in-Charge. Make: Usha/Universal/Havells
Supply & fix in replacement capacitors with new capacitors, 3.25 mfd, 50Hz, AC 220/440 Volts complete all as specified and directed by Engr-in-Charge. Make: Usha/Universal/Havells
M & L for removal / scrapping out old paint from Ceiling fan/exhaust fan complete and applying two coat of synthetic enamel paint , the colour of exhaust fan and ceiling fan shall be as per the directions of Engr in Charge, complete all as specified and directed by Engr-in-Charge.
M&L in Replacement of old fan regulators 5 step type with new fan regulators, stepped type electronic, piano switch type dully fixed on the existing laminated sheet/ board etc, complete all as specified and directed by Engr-in-Charge.
S & F in replacements of exhaust fan motor 450mm complete all as specified and directed by Engr-in-Charge. Make:Bajaj/Havells or equivalent make
S & F in replacements of exhaust fan motor 300mm complete all as specified and directed by Engr-in-Charge. Make:Bajaj/Havells or equivalent make
S & F in replacements of exhaust fan motor 250mm complete all as specified and directed by Engr-in-Charge. Make:Bajaj/Havells or equivalent make
Taking out of unserviceable automatic voltage stabilizer of capacity 4/5 KVA and transporting it to electrical repair shop for checking its serviceability and making complete functional to give constant rated voltage after repalcing all unseviceable parts and refixing it completely on site complete all as specified and directed by Engr-in-Charge.
De-scaling/De-carbonising of hot water generator/boiler capacity 50000 K/cal make rapid cool, disconnecting electrically, draining out of glycol, opening of burner chamber blower assembly all accessories and mounting on boiler and replacement of gasket and unserviceable parts as specified in each items mentioned directed by Engr-in-Charge. Note :- The item can be executed /measured in after every two month.
S&F in replacement of unserviceable Nozzle as required for 50000 K/cal capacity complete as specified and as directed by Engr-in-Charge
S&F in replacement of unserviceable Sequence controller assembly complete for boiler model LO24 and making complete electrical connections for smooth functioning of boiler 50000 Cal/Hr capacity complete all as specified and directed by Engr-in-Charge
S&F in replacement of unserviceable Photocell suitable for 50000 K/cal capacity complete as specified and as directed by Engr-in-Charge
S&F in replacement of unserviceable Electrorode for 50000 K/cal capacity complete as specified and as directed by Engr-in-Charge
S&F in replacement of unserviceable Diesel filter 50000 K/cal capacity complete as specified and as directed by Engr-in-Charge
M&L for servicing and calibration of burner assembly of capacity 50000 K/cal/hour complete as specified and as directed by Engr-in-Charge
S&F in replacement TPL pipe for burner and filter of 50000 K/cal complete as specified and as directed by Engr-in-Charge
M&L for servicing of the AHU assembly by replacing of bearing Greasing of shaft cleaning of dust in blower assembly including fabric action and welding works in duct and blower foundation for 15000 complete all as specified and directed by Engr-in-Charge. Note :- The item can be Executed and measured in every after two months.
M&L for servicing of the AHU assembly by replacing of bearing Greasing of shaft cleaning of dust in blower assembly including fabric action and welding works in duct and blower foundation for 35000 CFM capacity complete all as specified and directed by Engr-in-Charge. Note :- The item can be Executed and measured in every after two months.
S&F of in replacements Fan belt assembly complete with adjusting bolt for 15000 CFM AHU complete all as specified and directed by Engr-in-Charge
S&F of in replacements Fan belt assembly complete with adjusting bolt for 35000 CFM AHU complete all as specified and directed by Engr-in-Charge
M & L cleaning of complete central heating duct at ATC Crash/Hanger bay plant ,removing all dust and cleaned properly for smooth running of CHS Plant complete all as specified and directd by Engr-in-Charge.
S & F in replacements of wall mounted changeover switch 400 Amp with complete assembly dully mounted on wall with hole fastener complete all as specified and directed by Engr-in-Charge.
S & F in replacements glass wool Insulation with wire mess for 50 to 100 mm pipe dully fixing on Pipes with GI cladding complete all as specified and directed by Engr-in-Charge
Complete drain of Old water-glycol mixture from the existing ATC Crash bay CHS Plant and dumped at suitable place complete all as specified and directed by Engr-in-Charge.
Supply and filling of Ethylene Glycol in the existing ATC crash bay CHS Plant line and glycol tank complete all as specified and directed by Engr-in-Charge.
S & F hole fastener complete set 4 inch long complete all as specified and directed by Engr-in-Charge.
S & F hole fastener complete set 6 inch long complete all as specified and directed by Engr-in-Charge.
S & F in replacements of exhaust fan Louver Shutter Metallic body for 450mm sweep exhaust fan complete all as specified and directed.
S & F in replacements of exhaust fan Louver Shutter Metallic body for 300mm sweep exhaust fan complete all as specified and directed by Engr-in-Charge.
S & F in replacements of exhaust fan Louver Shutter Metallic body for 250mm sweep exhaust fan complete all as specified and directed by Engr-in-Charge.
S & F in replacements of Hanger Motor of cap 3 HP 3 Phase 415 V, 1400-1500 RPM , IP-55, Frame -GD100L, IE2, CosØ-0.79, Bi direction, incl chain Sprocket assembly , Spur Gear Box having Gear ratio B/W 30:1 to 50:1, Torque In B/W range of 15 NM to 22 Nm , with RPM range of 25 to 30 movement complete all as specified and directed by Engr-in-Charge.
S&F in repair/ Replacement of Starting Panel of Boiler for 2 L K cal complete all as specified and directed by Engr-in-Charge. Make: Rapid Cool or as per sample
S&F in repair/ Replacment of Burner of Boiler for 1 L K cal complete all as specified and directed by Engr-in-Charge. Make: Ecoflame or Equivelent or as per sample
Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 5 HP, 3 Phase,2880 RPM, Head 22 to 33m, size 50x40 mm, discharge 4.50 to 2.50 l/s complete all as specified and directed by Engr-in-Charge.
S&F in repair of DOL starter for 3 to 6 HP 3 Phase motor, of relay range 9 to 15 Amp, with single phase protection complete all as specified and directed by Engr-in Charge. Make: L&T, Seimens, ABB.
S&F in repair of PVC copper Conducter 3 Core 6 Sqmm from starter to motor Flat/ Round complete all as specified and directed by Engr-in-Charge. Make: Finolex, Polycab, Havells.
S&F in repair of PVC copper Conducter 3 Core 10 Sqmm form starter to motor Flat/ Round complete all as specified and directed by Engr-in-Charge. Make Finolex, Polycab, Havells.
M&L in repair Capacitor Metalized Poly propylene heavy duty (MPP-H) for 3 Phase 440 Volt, 50 Hz System for permissible non linear load 15 % of 20 KVAR complete all as specified and directed by Engr-in-Charge.
S&F in replacement sheet metal, single pole and neutral enclosure (factory made) with socket plug top and MCB, with a 2-pin and earth plug and socket, 240 volts, 20 amps, for AC point, complete all as specified and directed by Engr-in-Charge.
S&F in repair butterfly valve of brass body with chromium plated of size 80 mm dia fitted in centeral heating system or as required complete all as specified and directed by Engr-in-Charge.
S&F in repair butterfly valve of brass body with chromium plated of size 100 mm dia fitted in centeral heating system or as required complete all as specified and directed by Engr-in-Charge.
M/S NINDI BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .