| 1.00Work detail under EDD-I, Budaun | |||||
| 1.01 | 33KV underground 3x300 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 4m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit. High pressure testing of cable leveling the road with sand/ brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available (All Material shall be provided by the contractor except cable) | 7 | Job | 15,995 ₹1,11,965 Lowest | 16,990 ₹1,18,930 |
| 1.02 | 11KV underground 3x185 sq mm XLPE Cable/3x120 sq mm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable) | 6 | Job | 12,480 ₹74,880 Lowest | 13,990 ₹83,940 |
| 1.03 | LT underground 3.5Cx400/3.5Cx240/3.5Cx120 sqmm cable and Armoured LT service Cable of Size 4Cx16/4Cx10/2Cx6 sqmm fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable) | 89 | Job | 8,940 ₹7,95,660 Lowest | 9,990 ₹8,89,110 |
| 2.00Work detail under EDD-IV (Ujhani), Budaun | |||||
| 2.01 | 33KV underground 3x300 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 4m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit. High pressure testing of cable leveling the road with sand/ brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available (All Material shall be provided by the contractor except cable) | 7 | Job | 15,995 ₹1,11,965 Lowest | 16,990 ₹1,18,930 |
| 2.02 | 11KV underground 3x185 sq mm XLPE Cable/3x120 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable) | 6 | Job | 12,480 ₹74,880 Lowest | 13,990 ₹83,940 |
| 2.03 | LT underground 3.5Cx400/3.5Cx240/3.5Cx120 sq mm cable and Armoured LT service Cable of Size 4Cx16/4Cx10/2Cx6 sqmm fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable) | 30 | Job | 8,940 ₹2,68,200 Lowest | 9,990 ₹2,99,700 |
Tender Value
₹12.5 L
EMD Value
₹13,000
Closing Date
26 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
39/EDCB/2024-25
2024_MVVNL_959775_6
39/EDCB/2024-25
Open Tender
Electrical Works
Item Rate
365 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹3,540
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹13,000
7 Jan 2026
19 Dec 2025
26 Dec 2025
19 Dec 2025
26 Dec 2025
19 Dec 2025
19 Dec 2025 - 26 Dec 2025
Amount
Work detail under EDD-I, Budaun
33KV underground 3x300 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 4m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit. High pressure testing of cable leveling the road with sand/ brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available (All Material shall be provided by the contractor except cable)
11KV underground 3x185 sq mm XLPE Cable/3x120 sq mm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable)
LT underground 3.5Cx400/3.5Cx240/3.5Cx120 sqmm cable and Armoured LT service Cable of Size 4Cx16/4Cx10/2Cx6 sqmm fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable)
Work detail under EDD-IV (Ujhani), Budaun
33KV underground 3x300 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 4m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit. High pressure testing of cable leveling the road with sand/ brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available (All Material shall be provided by the contractor except cable)
11KV underground 3x185 sq mm XLPE Cable/3x120 sqmm XLPE Cable fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable)
LT underground 3.5Cx400/3.5Cx240/3.5Cx120 sq mm cable and Armoured LT service Cable of Size 4Cx16/4Cx10/2Cx6 sqmm fault-Locating fault, digging trench with the help of road cutter/digging machine/manual etc. Size of trench 3m, length x 1.5 m, width and up to depth of cable exposing the fault Cable preparing the cable, filling cable jointing kit, High pressure testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contractor as it was in earlier conditions including laying additional cable if necessary for cable jointing if loop is not available. (All Material shall be provided by the contractor except cable)
SHIV TRADERS (BID ID -5772215)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Tender_form39.pdf
Tender Documents • 0.83 MB
BOQ_2027728.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .