HQ Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone, S E Falls, Shillong-793011
PROVN OF 12 SINGLE OFFICERS ACCN AT RANGAPAHAR MIL STATON UNDER GE 868 EWS
2021_MES_479304_6
CESZ/RANG/16 OF 2021-2022
Open Tender
Civil Works
Lump-sum
365 days
Rangapahar
As per tender documents / NIT
2 documents required · 2 mandatory
₹2,000
GE 868 EWS
₹3.6 L
Yes
20 May 2023
15 Dec 2022
13 Jan 2023
15 Dec 2022
11 Jan 2023
30 Dec 2022
16 Dec 2022 - 22 Dec 2022
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDINGS & STRUCTURES WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the bidder/ tenderer for SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH, CULVERT & HARDSTANDING as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL, FENCING & GATE as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the bidder/ tenderer for DEMOLITION / DISMANTLING as listed in Schedule 'A' Part-XII
Sch 'A' Sec-XIII (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Material & Labour for Soakage wells for 25 users complete all as specified and as per drg No TD/CESZ/502 sheet 1/1.
Taking down existing MS garage shutters of size 2.6 x 2.3 Mtr complete all as specified and directed.
Taking down wash hand basin complete all as specified and directed.
Taking down EWC complete all as specified and directed.
Demolation of IWC complete all as specified and directed.
Taking down flushing cistern complete all as specified and directed.
Taking down bib cock, stop cock, angle cock, pillar cock, shower rose, towel rail, soap dish etc complete all as specified and directed.
Taking down kitchen sink of any size with or without drainage board complete all as specified and directed.
Taking down electric energy meter and carrying/depositing the meters to E/M store yard complete all as specified and directed.
Dismantling storage type water heaters(gysers) of any capacity and carrying and depositing the gyser to E/M store yard complete all as specified and directed.
Dismantling /Taking down MCBs DB incl MCBs of any capacity and carrying and depositing the MCBs, DB and MCBs to E/M store yard complete all as specified and directed.
Taking down old unsv service cable/UG aluminium conductor electric cable after necessary excavation in soft/loose soil including returning and refilling of trenches complete all as specified and directed.
Taking down old unsv submain wiring aluminium conductor complete all as specified and directed.
Supply & Fix LLDPE septic tank (25 users) designed to carry sewage and sludge water, excavation in soft/loose soil, PCC 1:3:6 type C-2 below foundation, Vent shaft connection etc complete with upflow filter including media complete all as specified and directed.
Supply, laying and testing of 160mm internal diameter of double wall corrugated(DWC) high density polyethylene pipes(HDPE) and stiffness class-8(SN-8) with IS mark with CML No with and including all fittings and jointing material for sewage line and laid in trenches as specified in IS-16098-2013 Part-II complete all as specified and as directed.
Supply & Fix Geyser, energy efficient, 5 star rating, 25 liters capacity, white/half white, copper steel alloy container inner tank with fiber reinforced body(FRB) puff insulation for both inner tank & for hot outlet copper connection pipe with all in built in safety accessories like thermostat/automatic thermal cut out with ON/OFF/CUT out indicators all pre-wired and aditional safety accessories like pressure release valve/pressure reducing valve, non return valve, including new PVC heavy duty pipe with brass ferrule fitting for Hot and Cold water connection fixed on new location as per manufacturers instruction/as ordered with suitable size nut & bolts, making necessary connection & testing on completion.
Supply & fix MCCB TPN 240V 100 Amps, 16 KA complete all as specified and as directed.
M&L Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 2.5 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit medium grade(IS-694 marked in PVC conduit) with fittings and one run of 2.5 Sq mm single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable as earth continuity conductor. NOTES :- (a) All runs of copper conductor cable and one run of conduit shall be measured as one run length.
M&L Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 4 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit medium grade(IS-694 marked in PVC conduit) with fittings and one run of 4 Sq mm single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable as earth continuity conductor. NOTES :- (a) All runs of copper conductor cable and one run of conduit shall be measured as one run length.
Supply & fix LED batten with extruded aluminium housing and extruded aluminium heatsink for mounting LEDs, mercury free, inbuilt driver and decorative end cap maximum power consumption 20-22W with system level output of 2050 lumens @6500 CCT operating voltage of 140-270 V AC PF >0.9, 2.5KV surge protection and current THD<=15% life class not less than 40000 burning hours as per L70 complete with all accessories including connecting of with twin core of PVC insulated 0.75 sqmm copper conductor cable upto ceiling rose. complete all as specified and as directed.
Supply & fix LED batten with extruded aluminium housing and extruded aluminium heatsink for mounting LEDs, mercury free, inbuilt driver and decorative end cap maximum power consumption 9-10W with system level output of 950 lumens @5700 CCT operating voltage of 140-270 V AC PF >0.9, 2.5KV surge protection and current THD<=15% life class not less than 40000 burning hours as per L70 complete with all accessories including connecting of with twin core of PVC insulated 0.75 sqmm copper conductor cable upto ceiling rose. complete all as specified and as directed.
Supply & fix LED security light made up of pressure die cast aluminium housing with high power LED as light source and lense embedded PC cover having top opening separate driver compartment with IP65 protection maximum power consumption 20-25 watt with system level output 2000 lumen@5700 CCT and CRI>70, PF>0.9 THD<10% operating voltage 230 Volt and impact resistance of IK07 with all accessories including suitable bracket of 32mm bore light grade 1.5m long GI pipe bend to shape, including MS clamp of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed.
Supply & fix AC single phase static energy meter of accuracy class 1.0, 240V, 50Hz with backlight LCD display of rating 5-30A & with 1 push button measures & display Kwh, KvAh,V,I,PF,Hz,Kw,Kva with six month history of energy & MD in Kw & Kva with transparent hinge type box complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceilling fan energy saving 1200mm(minimum) sweep, three blade, 5 star BEE rating without regulator including clamp set, hanging rod and necessary connecting PVC insulated flexible cable of size 0.75 Sqmm copper conductor for connection from ceilling rose to fan complete all as specified and as directed.
Supply and fixing ceilling fan energy saving 1400mm(minimum) sweep, three blade, 5 star BEE rating without regulator including clamp set, hanging rod and necessary connecting PVC insulated flexible cable of size 0.75 Sqmm copper conductor for connection from ceilling rose to fan complete all as specified and as directed.
Supply and fixing Exhaust fan energy saving 230mm(minimum) sweep, AC single phase 230V with self closing louvers and necessary connecting PVC insulated flexible cable of size 0.75 Sqmm copper conductor for connection from ceilling rose to fan complete all as specified and as directed.
Supply and fixing LED light fitting 1x18 watt(porch light) round shaped surface mounted LED luminaire, 230 Volts complete with all accessories including and connecting with twin core of PVC insulated 0.5 Sqmm copper conductor cable complete all as specified and as directed.
Supply and fixing epoxy powder coated Distribution Board VTPN 4 way, 12 module verticle type incomer as MCCB and outgoing MCBs with common bus-bar at incoming end of outgoing MCB grouted flush to wall complete all as specified.
M&L for point wiring with 1.5 Sqmm size FRLSH copper conductor cable single core multi stranded including PVC conduit medium grade with all fittings and MS terminal boxes suitable for housing modular switches, socket and regulators including modular inner plate and cover plates of suitable modules and 1.5 Sqmm size FRLSH copper conductor cable single core multi standard and connection to comman earth dolly all as specified and directed for the following:- (a) One light/fan /bell point controlled by one switch one way.
All as per Sl Item No 13.30 here-in-before but with cable size 2.5 Sqmm for one 5 pin 15 Amp socket outlet on independent board.
All as per Sl Item No 13.30 here-in-before but one light point controlled by two way switch on independent board.
All as per Sl Item No 13.30 here-in-before but one 3 pin socket outlet 5 Amp independent board
M&L for sand cushioning to full width of trenches for protection of cables with clean and dry river sand including punning down complete as specified. Note :- Punned thickness shall be measured and paid
M&L for laying sub class 'B' old size burnt brick for cable protection complete all as specified and as directed.
S&F health faucet (ABS chrome plated) with 8mm dia, 1Meter long flexible tube & wall hook. Make: Jaquar (Cat No ALD-573) or equivalent in Hindware /Cera
M/S DEEKSHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .