Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC NO 24 THIRUVALLUVAR NAGAR ASHOK NAGAR BACKSIDE PONDOSS AVENUE THANJAVUR 613005 | THANJAVUR | THANJAVUR | TAMIL NADU | 613005 | ₹14.7 L Quoted ₹14.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹15.7 L+₹84,937 (5.72%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | ₹15.7 L+₹84,937 (5.72%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹16.0 L+₹1.1 L (7.41%)Rejected-Finance 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | ₹16.0 L+₹1.1 L (7.41%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹16.0 L+₹1.2 L (7.75%)Rejected-Finance | ₹16.0 L+₹1.2 L (7.75%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹16.3 L+₹1.5 L (9.84%)Rejected-Finance EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | ₹16.3 L+₹1.5 L (9.84%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | NLK Construction L3 | S.T.S.CONSTRUCTIONS AGENCIES L6 | M/S. SRI RAMANUJA CONSTRUCTIONS L2 | NITHYASRI AND CO L4 | K C ASSOCIATES L5 | CHOLA AND CO L7 | CSJSV CONSTRUCTIONS L1 | R K BUILDERS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out and stripping old tarfelt over roofs, parapets walls of any description an in any direction including cement plastering and removing the rubbish n.exc 1.50 KM etc including removing the debrish outside MD land complete all as specified and as directed. | 135 | Sqm | 25 ₹3,375 Lowest | 99 ₹13,365 | 38 ₹5,130 | 200 ₹27,000 | 255 ₹34,425 | 210 ₹28,350 | 33 ₹4,455 | 150 ₹20,250 |
| 2.00 | M&L PCC padding 1:2:4 type B0 using 12.5mm graded crushed stone aggregate in average thickness 40mm laid over & incl chicken wire mesh 0.60m dia with apertue 12x12 mm stapled properly with existing surface of concerte. Top surface of concrete finished even and fair without using extra cement complete all as specified and as directed.
Note:-
Water retaining test (Ponding test) shall be carried out after PCC padding for 48 hrs. Incase indication of leakages / seepages is noticed the same shall be rectified by grouting the affected portion at no extra cost. Thereafter ponding test shall be repeated till there is no seepages / leakages. | 135 | Sqm | 300 ₹40,500 | 650 ₹87,750 | 300 ₹40,500 | 600 ₹81,000 | 515 ₹69,525 | 700 ₹94,500 | 264 ₹35,640 Lowest | 550 ₹74,250 |
| 3.00 | M&L applying oil based bitumen primer confirming to IS 3384-1986 at 0.20 kg/Sqm on prepared surface and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm and applying roof treatment with APP modified waterproofing membrane weighing not less than 3kg/sqm, reinforced with non woven polyster matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650N/Sqm cm, tearing strength of 180N(Minimum), applied by torch-on application including minimum 10 cm over lap and 15 cm end lap and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm over the membrane and then applying solar reflective bituminous aluminium paint for thermal insulation @ 0.10 kg/sqm complete all as specified and as directed. | 135 | Sqm | 624 ₹84,240 | 125 ₹16,875 Lowest | 580 ₹78,300 | 850 ₹1,14,750 | 910 ₹1,22,850 | 650 ₹87,750 | 532 ₹71,820 | 750 ₹1,01,250 |
| 4.00 | M&L cutting out cracks to V section in existing roofs or terracing cleaning out, wetting, grouting, with cement and sand slurry 1:3 complete all as specified and as directed. | 25 | Rm | 38 ₹950 Lowest | 250 ₹6,250 | 50 ₹1,250 | 300 ₹7,500 | 200 ₹5,000 | 180 ₹4,500 | 44 ₹1,100 | 550 ₹13,750 |
| 5.00 | Dismantling of Plain or corrugated steel any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed. | 350 | Sqm | 60 ₹21,000 Lowest | 250 ₹87,500 | 65 ₹22,750 | 100 ₹35,000 | 105 ₹36,750 | 130 ₹45,500 | 62 ₹21,700 | 850 ₹2,97,500 |
| 6.00 | S&F pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per manufacturers instruction complete all as specified and as directed. | 150 | Sqm | 847 ₹1,27,050 | 999 ₹1,49,850 | 825 ₹1,23,750 | 900 ₹1,35,000 | 900 ₹1,35,000 | 900 ₹1,35,000 | 798 ₹1,19,700 | 450 ₹67,500 Lowest |
| 7.00 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through complete all as specified and as directed. | 50 | Sqm | 700 ₹35,000 Lowest | 999 ₹49,950 | 800 ₹40,000 | 900 ₹45,000 | 900 ₹45,000 | 980 ₹49,000 | 722 ₹36,100 | 1,350 ₹67,500 |
| 8.00 | S&F 2mm thick plain multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end fixed with self drilled screws and standard fittings, fixtures and accessories as per manufactures instructions complete all as specified and as directed. | 20 | Sqm | 3,021 ₹60,420 | 2,500 ₹50,000 | 3,150 ₹63,000 | 800 ₹16,000 | 810 ₹16,200 | 750 ₹15,000 | 2,895 ₹57,900 | 580 ₹11,600 Lowest |
| 9.00 | M&L 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and as directed. | 130 | Sqm | 1,324 ₹1,72,120 | 850 ₹1,10,500 | 1,260 ₹1,63,800 | 850 ₹1,10,500 | 815 ₹1,05,950 | 700 ₹91,000 Lowest | 1,217 ₹1,58,210 | 960 ₹1,24,800 |
| 10.00 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed. | 200 | Sqm | 100 ₹20,000 | 99 ₹19,800 Lowest | 105 ₹21,000 | 120 ₹24,000 | 110 ₹22,000 | 210 ₹42,000 | 102 ₹20,400 | 280 ₹56,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Aug 2026, 6:00 pmClosed
Garrison Engineer
Garrison Engineer AF Thanjavur
REPAIR TO ROOF, WALL, FLOORING, HANGAR DOOR AND BIRD PROOFING NET AT CERTAIN OTM ACCN UNDER AGE B/R-II AT AFS THANJAVUR
2026_MES_780820_1
8294/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer AF Thanjavur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer
₹30,000
Yes
22 Sept 2026
25 Jul 2026
22 Aug 2026
25 Jul 2026
15 Aug 2026
9 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out and stripping old tarfelt over roofs, parapets walls of any description an in any direction including cement plastering and removing the rubbish n.exc 1.50 KM etc including removing the debrish outside MD land complete all as specified and as directed. | 135 | Sqm | - | - |
| 2 | M&L PCC padding 1:2:4 type B0 using 12.5mm graded crushed stone aggregate in average thickness 40mm laid over & incl chicken wire mesh 0.60m dia with apertue 12x12 mm stapled properly with existing surface of concerte. Top surface of concrete finished even and fair without using extra cement complete all as specified and as directed.
Note:-
Water retaining test (Ponding test) shall be carried out after PCC padding for 48 hrs. Incase indication of leakages / seepages is noticed the same shall be rectified by grouting the affected portion at no extra cost. Thereafter ponding test shall be repeated till there is no seepages / leakages. | 135 | Sqm | - | - |
| 3 | M&L applying oil based bitumen primer confirming to IS 3384-1986 at 0.20 kg/Sqm on prepared surface and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm and applying roof treatment with APP modified waterproofing membrane weighing not less than 3kg/sqm, reinforced with non woven polyster matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650N/Sqm cm, tearing strength of 180N(Minimum), applied by torch-on application including minimum 10 cm over lap and 15 cm end lap and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm over the membrane and then applying solar reflective bituminous aluminium paint for thermal insulation @ 0.10 kg/sqm complete all as specified and as directed. | 135 | Sqm | - | - |
| 4 | M&L cutting out cracks to V section in existing roofs or terracing cleaning out, wetting, grouting, with cement and sand slurry 1:3 complete all as specified and as directed. | 25 | Rm | - | - |
| 5 | Dismantling of Plain or corrugated steel any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed. | 350 | Sqm | - | - |
| 6 | S&F pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per manufacturers instruction complete all as specified and as directed. | 150 | Sqm | - | - |
| 7 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through complete all as specified and as directed. | 50 | Sqm | - | - |
| 8 | S&F 2mm thick plain multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end fixed with self drilled screws and standard fittings, fixtures and accessories as per manufactures instructions complete all as specified and as directed. | 20 | Sqm | - | - |
| 9 | M&L 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and as directed. | 130 | Sqm | - | - |
| 10 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed. | 200 | Sqm | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TenderDocuments8294.pdf
Tender Documents • 1.14 MB
BOQ_874680.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .