Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.9 LAccepted-AOC 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | L-1 | Accepted-AOC L-1
(Excluding Sl. NO. 2 and 6 of Item rate BOQ) | |
| 2 | L-2₹47.5 L+₹71,550 (1.53%)Rejected-AOC | L-2 | Rejected-AOC L-2
(Including Sl. NO. 2 and 6 of Item rate BOQ) | |
| 3 | L-3₹48.0 L+₹1.2 L (2.58%)Rejected-AOC 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | L-3 | Rejected-AOC L-3
(Including Sl. NO. 2 and 6 of Item rate BOQ) | |
| 4 | L-4₹48.4 L+₹1.6 L (3.45%)Rejected-AOC E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | L-4 | Rejected-AOC L-4
(Including Sl. NO. 2 and 6 of Item rate BOQ) | |
| 5 | L-5₹53.3 L+₹6.5 L (13.8%)Rejected-AOC | L-5 | Rejected-AOC L-5
(Including Sl. NO. 2 and 6 of Item rate BOQ) |
Tender Value
₹79.7 L
EMD Value
₹1.6 L
Closing Date
31 Jul 2020, 6:00 pmClosed
Sh. K Santhosh Kumar, AGM (E-E)
Office of AGM (E-E), NATS Complex, IGI Airport, New Delhi - 110037
Annual Comprehensive Maintenance and Operation of 2 Nos. X 250 TR and 2 Nos. X 120 TR Central Air Conditioning Plant for 02 Years at NATS Complex, IGI Airport, New Delhi (2020-22)
2020_AAI_53587_1
AAI/NATS/EE/AMC-AC Plant/2020
Open Tender
Electrical Works
Works
730 days
NATS Complex, IGI Airport
As per ENIT, PQQ Check List and Tender Documents
4 documents required · 4 mandatory
₹1,120
Yes
Airports Authority of India
₹1.6 L
Yes
24 Dec 2020
24 Jul 2020
5 Aug 2020
25 Jul 2020
31 Jul 2020
25 Jul 2020
25 Jul 2020 - 31 Jul 2020
Amount
1. Annual Comprehensive maintenance of 2 x 250 TR Central Air-conditioning Plant complete as per technical specifications mentioned in the tender document. The scope of work includes preventive maintenance as per technical specification enclosed in the tender document, repair and replacement of any item/part related to the plant complete as required (The scope of work does not includes maintenance /repair /replacement of any item/part related to various pumps, cooling towers, AHUs, pipelines,valves and all electrical panels associated with AC Plant etc. which are covered under Item No- 03 below).
2. Annual Comprehensive maintenance of 2x 120 TR Central Airconditioning Plant complete as per technical specifications mentioned in the tender document.The scope of work includes preventive maintenance as per technical specification enclosed in the tender document, repair and replacement of any item/part related to the plant complete as required. (The scope of work does not includes maintenance / repair / replacement of any item/ part related to various pumps, cooling towers, AHUs, pipelines, valves and all electrical panels associated with AC Plant etc. which are covered under Item No- 03 below).
3. Annual Comprehensive maintenance of all the balance items / accessories related to the above mentioned Central AC plants i.e. (2 X 250 TR) and (2 X 120 TR) like Chilled water & condensor water pump sets, 4 No.x320 Tr. Cooling Towers, AHUs/FCU of various capacities , all electrical panel boards alongwith switch gear of all ratings associated with AC Plant, control panels, associated chilled water and condenser water pipelines & valves, all ducting,grills, fire dampers etc complete as required as per technical specifications enclosed in the tender document.
4. Operation of the above mentioned (2 x 250 and 2 x 120 TR) complete Central Air-conditioning Plant and other associated equipment mentioned at item No.3 above on all working days i/c holidays round the clock(in 03 shifts).The contractor shall deploy the following manpower in each shift : (a) A/C Operator cum Mechanic( Skilled) - 1No.in each shift . (b) A/C Operator cum Electrician( Skilled) - 1No.in each shift.
SPARES / ACCESSORIES (AS AND WHEN REQUIRED)
5. Supply and installation of Honeycomb PVC Fills each of size 600mm x 300mmx 150mm, suitable for cooling tower having heat rejection capacity 9,71,500 K.Cal/hr (minimum) of make ADVANCE2020 Model No TM144 installed for HVAC plant at NATS Complex including removal and disposal of old Fills out side the NATS complex etc as per EIC satisfaction.
6. Supply of Box Type Pre Filters in GI frame of Synthetic (non woven type) of efficiency 90% down to 10 micron of different sizes as below suitable for Zeco Make Air Handling Units of various capacities installed at NATS complex .
6(a) Filter of Size 610 mm x 610 mm x 50 mm .
6(b) Filter of Size 610 mm x 305 mm x 50mm .
6(c) Filter of Size 305 mm x 305mm x 50mm .
7. Supply, Installation, Testing and Commissioning of 3 way Modulating valve of PN 10 for AHUs with integrated 2 way modulating Control valves in a single body, modulating thermostat of various sizes. (Make : Rapid Control). It includes the dismantling of existing valve.
PAN POLAR ENGINEERS PVT. LTD.
Arctic Engineering Services
Supertech Engineers
HARDEV AIRCON WORKS
AIRTECH ENGINEERS
ANOOP REFRIGERATION
KRISHNA REFRIGERATION
Zamzam Refrigeration and airconditioning
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .