Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Work Completed. | |
| 2 | L2₹18.4 L+₹97,555.04 (5.60%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹18.5 L+₹1.1 L (6.11%)Rejected-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L3 | Rejected-Finance Higher Bidder |
Tender Value
Refer Docs
EMD Value
₹34,840
Closing Date
30 Aug 2024, 1:00 pmClosed
Executive Engineer Paschim Med. Elecl. Div. PWDte.
Executive Engineer Paschim Med. Elecl. Div. PWDte. Midnapore, Paschim Medinipur
E.I. repair and renovation work of Blood Bank of Ghatal SDH/SSH, Paschim Medinipur.
2024_WBPWD_732801_1
WBPWD/EE/PMED/NIQ-03/e-Q /2024-2025
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Ghatal, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹34,840
Off. of the EE, Pas. Mid. Elec. Divn. PWDte.
26 Apr 2025
12 Aug 2024
2 Sept 2024
12 Aug 2024
30 Aug 2024
21 Aug 2024
20 Aug 2024
Amount
Supply and fixing 415V, 125 A TPN SFU with sheet steel enclosure mounted on Angle Iron Frame on wall fixing with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.incl. 2nos. cable end box. (Make : L&T / Siemens/ Schneider).
S & D of 4 Core 50sqmm 1.1Kv grade XLPE insulated Al/A cable. (Make- Polycab/ Havells/ Gloster/KEI)
Laying of 4core 50sq.mm. cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth 100mm. and mending good the damages to original finish incl. removing the rubbish.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4core 50sq. Mm. XLPE/PVC armoured cables.
Finishing the end of 4core 50sq. Mm. XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
Supply and fixing 415V, 16-32A per way,4 Way vertical TPN MCBDB with provision for DPX 125 & EIM as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following. a) 125A, 36KA, 4 pole MCCB -- 1 No. b) 63A, 10ka ('C'- Curve) TP MCB --4 Nos c) Cable entry box -- 2 No (Make- Siemens/ Schneider/ Legrand)
Supply and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall. 8Way: Enclosure, 63A FP MCB type Isolator, 24 no. 16-32A SPMCB (Make- Siemens/ Schneider/ Legrand)
Supply and fixing 250 V, 6-10A per way, (2+8 way)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 1no. 40A DP MCB type Isolator, 8 no. (6-16A) SPMCB) (Make- Siemens/ Schneider/ Legrand)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 3 mm thick Polythene pipe (without earth continuity wire) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles incl. S&F of following pipe
a) 19 mm dia pipe
b) 25 mm dia pipe
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes incl. S& F bakelite / perspex top cover by Brass screws, flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
Supply and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Policab/ Havells/ Gloster/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
a) 4x126/0.4(16 sqmm) +2x80/0.4(10 sqmm) (from VTPNDB to TPNDB)
b) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (from TPNDB to SPNDB)
c) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC(ac machine)
d) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(for 20A power plug,computer board )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5sqmm.
b) 4sqmm
c) 6sqmm
d) 10 sqmm
e) 16 sqmm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Policab/ Havells/ Gloster/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Policab/ Havells/ Gloster/KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish [ (2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) ] On board.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 1 nos. 6A, & 1 no. 20A plug socket with separate 1 nos. 6 A & 1 no. 20A Piano key type switch, (Brand approved by EIC) on 175mm x 100 mm x 65 mm size sheet metal switch board embedded in wall and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) (only top floor)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
S & Delivery of 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork etc. (Make- Orient- summer breeze/ Crompton).
S & Delivery of 240V 50 Hz 56" sweep (1400 mm) ceiling fan complete with down rod, Canopy, fork etc. (Make- Orient- summer breeze/ Crompton).
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible coppe wire.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply and Delivery of 230V, Single LED tube light fittings incl. all acc. Make- Wipro, Cat No.- WIO921208/ Crpmpton/ Philips.
Supply and Delivery of 230V,20 watt Polycarbonate body LED tube light (Make- Wipro, Cat No.- LL13-181-65SE/ Philips/Crompton)
S&D 250V. 50 Hz. 9 inchi Sweep 920 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make)
Fixing only 23 cm (9") exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 23 cm Exhaust fan (9")
Supply & Fixing 9W LED lamp. (make- Philips/ Crompton/ Bajaj)
S & F of 240 V Timer DB equivalent to (10 + 2) way SPN double door make DB with SS enclosure phosphitised powder coated incl din rail with IP - 43 protection comprises with 1 nos 32 A DP MCB (C Curve,10 KA) 1 nos 24 hours programmable Time Switch with minimum switching time of 15 minutes ,1 nos 25 A 2 pole power contactor complete with outer cover plate & internal wiring by 4 sqmm copper wire 1 nos. Auto Manual bypass toggle switch ,earthing attachment incl 1 nos LED indication light for running condition & locking arrangement. (Make : L&T / ABB/ Schneider/ siemens)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with modular type plug top with indicator and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Delivery of non-inverter, fixed Speed Room Air Conditioner fitted with rotary compressor and copper condensing and cooling coil having following major specification. Refrigerant- R410A, Capacitor Type: P2 Minimum cooling capacity (KW): 5.2 or higher Maximum power consumption: 1450 watts or less EER star rating: 3.57 (2 Star/2023) or higher as per recent year manufacture Minimum tonnage required 1.5TR or higher with other modern features. Minimum Room discharge Air flow(CFM) : 777 or higher & energy efficient type, with approved make as per IS 1391, Part-I, with remote and all the necessary connection etc. as per direction of EIC Make:- Mitsubishi Electric/Mitsubishi Heavy Industries/O-General
Installation,Commissioning and testing of 2.0/1.5 ton split type AC machine both indoor/outdoor including fixing of 40 x 40 x 5 mm MS angle iron frame and mending good the damages.
Supply and delivery of (I) Copper pipe 3/8"/1/2" for liquid as required. (II) 3 core 2.5 sqmm. Cu. cable (III) Copper pipe 5/8" / 1/4"for suction as required (IV) Insulation Foam 3/8" / 1/2" for liquid as required. (V) 5/8" / 1/4"for suction as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe.
S & F earth busbar galvanized ( Hot Dip ) MS flat 25 mm x 6 mm on wall as per GS .
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages No. 4 SWG
Excavation of morrum soil for installation of Earth Electrode and filling & ramming.
Dismentalling the existing wiring and fittings etc. and total material submitted to the concern section office.
ELCON ENGINEERS
M/S JOGMAYA ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .