RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC) Bid to RA enabled Yes Signal Analyzer ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) MEASUREMENT FEATURES Frequency Range 9KHz to 13 GHz 20Hz - 3 GHz
Required20Hz - 6 GHz
Required20Hz - 13 GHz
Required20Hz - 26.5 GHz
Required9KHz to 13 GHz
Required9KHz to 6 GHz
Required9KHz to 20 GHz Capture/Demodulati on Bandwidth (Max) 40 10
Required25
Required40 Maximum Safe Input Level <=+30 dBm * Displayed Average -140 dBm/Hz * 1/5 Noise Level across the frequency range Span in real time spectrum 40 * Phase noise measurement NA * Sample Rate (Megasample/sec) 100 10
Required20
Required50
Required100
Required200
Required500 Ref Frequency Aging 1 x 10 ^ -7 * I/Q(In phase/Quadrature) memory Depth 256 * Trigger Free Run
RequiredPower Trigger
RequiredExternal * Traces Types Normal (RMS)
RequiredAverage
RequiredMax. Hold
RequiredMin. Hold * Modulation Analysis AM
RequiredFM
RequiredPM
RequiredBPSK
RequiredQPSK
RequiredP i/4DQPSK
Required8PSK
Required16SQA M
Required32QAM
Required64QAM
Required128Q AM
Required256QAM
RequiredGMSK
RequiredGFS K * Multi Domain Analysis with Stand Alone Software Time
RequiredFrequency
RequiredModul ation
RequiredSpectrogram * Pre-defined Measurement IQ vs Time
RequiredPower vs Time
RequiredFrequency vs Time
Requiredcrest factor
RequiredPulse Measurements: Pulse Width
RequiredPulse Peak Power
RequiredOn and Off Ratio
RequiredPulse Ripple
RequiredDuty Cycle Pulse- Pulse
RequiredPhase
RequiredChannel Power
RequiredCCDF
RequiredOccupied BW
RequiredFrequency Deviation
RequireddB per Hz
RequireddBc per Hz MKr
RequiredPulse characteristics
RequiredPulse Repetition Interval * Automatic Measurement (Time Mode) IQ vs Time
RequiredPower vs Time
RequiredFrequency vs Time
RequiredCCDF
Requiredcrest factor
RequiredPulse Measurements:Pulse Width
RequiredPulse Peak Power
RequiredOn/Off Ratio
RequiredPulse Ripple
RequiredPulse Repetition Interval
RequiredDuty Cycle Pulse- Pulse
RequiredPhase
RequiredChannel * 2/5 Power
RequiredOccupied BW
RequiredFrequency Deviation
RequireddB per Hz
RequireddBc per Hz MKr
RequiredPulse characteristics Any other features - * OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Temperature 55 * Relative Humidity Non Condensing(%) 80 * POWER SOURCE Power Requirements 230 +/- 10% VAC
Required50 Hz * GENERIC Rack Mount Kit for Signal Analyzer no * Interface USB * ACCESSORIES Details of the Standard Accessories Supplied with the Equipment - * TEST REPORT DETAILS & TESTS Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification Yes * Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no * 3/5 * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.