| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.9 L+₹1.7 L (7.30%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹31.7 L+₹8.5 L (36.6%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹47,500
Closing Date
13 Oct 2021, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
REPAIR MAINT OF TRANSFORMERS AND ALLIED WORKS AT KUPWARA DURGMULLA TANGDHAR CHOWKIBAL NIYARI TREHGAM PATHAHIRI PANZGAM BANDIPUR AND DAWAR GARRISION UNDER GE 874 EWS
2021_MES_441598_4
CWEK-18/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 874 EWS
Class E Category b ii
7 documents required · 7 mandatory
₹500
GE 874 EWS
₹47,500
Yes
HQ 133 WORKS ENGRS
18 Nov 2021
22 Sept 2021
15 Oct 2021
22 Sept 2021
13 Oct 2021
29 Sept 2021
22 Sept 2021 - 25 Sept 2021
27 Sept 2021
Amount
Repair/maintenance and servicing of step down transformer 11 KV/433 Volt of capacities 100 to 250 KVA, of any make, Installed at different locations of AOR comprising following work services :- (a) Disconnection carefully of cable end termination of HT & LT side. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (c) Draining out transformer oil and keeping aside in barrel for re-use and then again pouring back after necessary filteration and dehydration including top up with new transformer oil to make up the reduced quantity. (d) Replacement of top gaskets. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Labour only for cleaning of bush and stud both HT/LT side and refixing the same with new cock sheet as required. (g) Replacing unserviceable stud and bush as required as directed by engineer-in-Charge. (h) Reconnection of all cable terminals HV & LV sides and refixing the top cover after replacement of gaskets, conservator tank in position. (j) Cleaning and heating of silica gel in breather and replacing with new silica gel to make up the reduced quantity. (k) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead. (l) Provision of a functional transformer of same or higher capacity while the transformer is taken for repair. (m) Any transportation of the transformer to and from the location of installation to the contractors workshop, including installation back as specified by engineer in charge. Note : (i) Spare parts not mentioned above (if required) will be measured and paid separately. (ii) New transformer oil (if required for topping up) will be measured and paid separately. (iii) De-hydration of existing transformer oil for refilling will be measured and paid separately. (iv) The transformers have to be taken for repair and a replacement transformer of same or higher capacity to be placed within 48 hrs from intimation in phone/ through whatsapp, irrespective of any weather issues. For this purpose, the contractor has to submit a functional phone and whatsapp number that is not to be switched off at any time. Any delay beyond this time will be fined at the rate of Rs. 1000 per day per transformer
All as per item No 01 here-in -before but for Auxiliary HT Transformer & 11 KV/433 Volts transformer of capacities 40 to 150 KVA.
All as per item No 01 here-in -before but for HT transformer of capacities 1600 KVA (Replacement Transformer not required for upto 168 hours (7 days) All other description is same as in item No 01 Note No (iv)
Supply and fixing bushing and stud complete with porcelain insulators and gasket complete for LT side (as per existing size/Model) of Transformer complete all as specified and directed.
Supply and fixing bushing and stud complete with porcelain insulator and gasket complete for HT side (as per existng size/Model) of transformer complete all as specified and directed.
Replacement of burnt/ unserviceable defective HT/ LT copper coil of transformers, AVRs and Servo Voltage Stabilisers with new one made out of suitable size/ guage of copper super enameled wire of high quality matching with the existing impendence and insulated all as specified and directed by engineer-in-Charge. Note :- (a) The cost of coil shall be inclusive of cost of varnish, insulating paper and other insulating materials and no extra payment will be made for the same. (b) The cost is inclusive of disconnecting of all electrical connections and transportation of transformer from site to reputed repair workshop and back including reinstalling & reconnecting electrical connection and no extra payment will be made for the same. (c) Standby transformer/ stabiliser/ AVR will be arranged by contractor at his own cost to avoid failure of supply on site and the capacity of transformer should be matched with repaired transformer. This standby transformer will be brought within 48 hours of intimation (either by phone or by whatsapp) of unserviceability of the original transformer (for this purpose, the contractor has to provide a whatsapp number that is always functional).
Dehydration and filtration of transformer oil of transformer / Servo voltage stablizer/ AVR installed at site with portable plant to improve the dielectric strength to 50 KV during filling after initial filtration including testing of dielectric strength after dehydration at site complete all as specified and directed. Note : Any damage to transformer/ stabiliser/ AVR caused during oil dehydration and filteration will be rectified by the contractor free of charge.
Supply only for transformer oil having minimum dielectric strength of 60 KV, supplied in hermetically sealed steel barrels, confirming to IS-335, all as directed at site by engineer-in Charge (Part of this Transformer oil may be required to be filled in Transformers, which is included in this schedule)
Painting of transformers/ stabilisers/ AVRs/ VCB panel set/ OCB Panel Set of any capacity after cleaning the body surface of transformer by rubbing with emery Paper and acetone to remove oil stains, dust etc and applying one coat of snthetic enamel paint (colour to be decided by MES) by spray painting including writing SM No/MES No, capacity of transformer, OCB panel all as directed by Engineer-in-Charge.
Dismantling the voltage stabilizers/ AVRs (any type) by taking out transformer oil and storing for reuse (after cleaning, filtering and removing moisture from it) and repairing / replacing the unserviceable parts, reassembling it after repair testing and commissioning the voltage stablizer of capacity 100 to 250 KVA unbalanced type Installed at different location of AOR (spares to be measured and paid separately under relevant item of this schedule). Note : The Stabilisers/ AVR have to be taken for repair and a replacement Stabiliser/ AVR of same/ higher capacity to be placed within 168 hrs (seven days) from intimation in phone/ through whatsapp, irrespective of any weather issues. For this purpose, the contractor has to submit a functional phone and whatsapp number that is not to be switched off at any time. Any delay beyond this time will be fined at the rate of Rs. 1000 per day per stabiliser/ AVR
Supply and fixing in repair servo motor of 3 Kg torque capacity/rating complete for voltage correction having speed of correction 8 volt per second Make AE/ Paradise/ Voltamp complete all as specified and directed. Note : This item may also be taken as a supply only item if desired by Engineer in Charge
Supply and fixing in repair servo motor of 10 Kg torque capacity/rating complete for voltage correction having speed of correction 8 volt per second Make AE/ Paradise/ Voltamp complete all as specified and directed. Note : This item may also be taken as a supply only item if desired by Engineer in Charge
Supply and fixing in repair of Dimmerstat for unbalanced servo stabilizer all as specified and directed by engineer-in-charge.
Supply and fixing in repair of RC network for 10 Kg servo motor part/circuit for (any type of) voltage stabilizers If suitable RC network is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Supply and fixing in reapir of RC network for 3 Kg servo motor part/circuit for (any type of) voltage stabilizers If suitable RC network is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Supply and fixing in repair for trigger transformer 24 volt for balanced type voltage stablizer all as specified and directed by engineer-in-charge.
Supply and fixing in repair for PCB Holder for unbalanced type voltage stablizer all as specified and directed by engineer-in-charge. Note : If compatible PCB holder is not obtained by the contractor, then all suitable modifications (to the stabiliser to fit a PCB holder available with the contractor) with labour and material are also included
Supply and fixing in repair Push button for voltage stablizer all as specified and directed by engineer-in-charge.
Supply and fixing in repair Auto manual switch for voltage stablizer all as specified and directed by engineer-in-charge.
Supply and fixing in repair Rotary switch for RYB phases of voltage stabilizer all as specified and directed by engineer-in-charge.
Supply and fixing in repair for carbon bush of voltage stabilizer at site of any capacity all as specified and directed by engineer-in-charge.
Supply and fixing PCB /control card of (any type of) voltage stabilizer of capacity 50 KVA to 400 KVA for unbalanced type voltage stablizer If suitable control card/ PCB is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Supply and fixing in repair of bushing assembly including brass nut, stud, washer and insulator suitable for voltage stabilizers/ AVR all as specified and directed by engineer-in-charge.
Supply and fixing digital three phase Voltmeter - 0-500 Volt range square shape 96mm all as specified and directed by engineer-in-charge. Note : This item may also be taken as a supply only item if desired by Engineer in Charge
Supply and fixing digitial three phase Ammeter - 0-500 Ampere range square shape 96mm, with necessary CTs all as specified and directed by engineer-in-charge. Note : This item may also be taken as a supply only item if desired by Engineer in Charge
Material and Labour for replacement of Control Wiring complete with suitable copper wire of required size or as per sample/directed including accessories for voltage stabilizer (of any type) of capacity 200-400 KVA. If suitable control wiring is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Material and Labour for replacement of Control Wiring complete with suitable copper wire of required size or as per sample/directed including accessories for voltage stabilizer (of any type) of capacity 63-250 KVA. If suitable control wiring is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Material and Labour for replacement of Control Wiring complete with suitable copper wire of required size or as per sample/directed including accessories for voltage stabilizer (of any type) of capacity 50-160 KVA. If suitable control wiring is not available in the market, then necessary modifications to the voltage stabiliser is also included all as specified and directed by engineer-in-charge.
Supply and fixing DPDT switch for balanced type voltage stablizer all as specified and directed by engineer-in-charge.
Calibration and Maintenance of Transformer Oil BDV Testing Machine, including all necessary spares/ parts and jobs to make the unserviceable machine functional, all as specified, directed and clarified by engineer-in-charge.
Supply and fixing Panel Lamp for balanced type voltage stablizer all as specified and directed by engineer-in-charge.
M/s Lal Enterprises
M/S NORTHERN ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .