Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹44.6 L+₹5.1 L (13.0%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹44.6 L+₹5.2 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹45.1 L+₹5.6 L (14.1%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹45.4 L+₹6.0 L (15.1%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | ASHWAMEDH ENGINEERS L8 | M/S. Niksun Electro-Infra Private Limited L2 | SKS Electricals L4 | JP ENTERPRISES L7 | MANGAL ELECTRICAL STORES L1 | Sunhari Electricals L6 | Om Construction L3 | ONKAR ELECTRIC AND GENERAL STORE L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth n. exc 10 sqm on plan for laying of cables,pole foundation,stays etc and getting out in soft loose soil, complete all as specified and as directed. | 600 | Cum | 120 ₹72,000 | 180 ₹1,08,000 | 150 ₹90,000 | 300 ₹1,80,000 | 100 ₹60,000 Lowest | 160 ₹96,000 | 200 ₹1,20,000 | 360 ₹2,16,000 |
| 2.00 | Description all as per item No 1 above but in soft disintegrated rock. | 150 | Cum | 200 ₹30,000 | 180 ₹27,000 | 220 ₹33,000 | 200 ₹30,000 | 140 ₹21,000 Lowest | 200 ₹30,000 | 300 ₹45,000 | 450 ₹67,500 |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed . | 700 | Cum | 30 ₹21,000 | 28 ₹19,600 | 40 ₹28,000 | 100 ₹70,000 | 25 ₹17,500 Lowest | 30 ₹21,000 | 50 ₹35,000 | 190 ₹1,33,000 |
| 4.00 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. | 150 | Cum | 30 ₹4,500 | 28 ₹4,200 | 50 ₹7,500 | 100 ₹15,000 | 25 ₹3,750 Lowest | 30 ₹4,500 | 60 ₹9,000 | 110 ₹16,500 |
| 5.00 | Material and labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and as directed. | 8 | Cum | 3,000 ₹24,000 | 3,800 ₹30,400 | 4,500 ₹36,000 | 3,500 ₹28,000 | 2,500 ₹20,000 Lowest | 4,000 ₹32,000 | 4,000 ₹32,000 | 3,000 ₹24,000 |
| 6.00 | Material and labour for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and as directed. | 5 | Cum | 3,000 ₹15,000 | 3,800 ₹19,000 | 4,500 ₹22,500 | 3,500 ₹17,500 | 2,700 ₹13,500 Lowest | 4,000 ₹20,000 | 5,000 ₹25,000 | 3,500 ₹17,500 |
| 7.00 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified and as directed. (excavation and earth work shall be measured and paid separately) | 2,000 | RM | 55 ₹1,10,000 | 70 ₹1,40,000 | 50 ₹1,00,000 | 100 ₹2,00,000 | 40 ₹80,000 Lowest | 60 ₹1,20,000 | 55 ₹1,10,000 | 60 ₹1,20,000 |
| 8.00 | Description all as per item No-07 above but of size 50mm outer dia. | 1,000 | RM | 60 ₹60,000 | 70 ₹70,000 | 70 ₹70,000 | 200 ₹2,00,000 | 50 ₹50,000 Lowest | 80 ₹80,000 | 78 ₹78,000 | 80 ₹80,000 |
| 9.00 | Description all as per item No- 07 above but of size 63mm outer dia | 500 | RM | 70 ₹35,000 | 81 ₹40,500 | 90 ₹45,000 | 220 ₹1,10,000 | 60 ₹30,000 Lowest | 90 ₹45,000 | 92 ₹46,000 | 90 ₹45,000 |
| 10.00 | Description all as per item No- 07 above but of size 90mm outer dia. | 200 | RM | 100 ₹20,000 | 112 ₹22,400 | 110 ₹22,000 | 250 ₹50,000 | 90 ₹18,000 Lowest | 120 ₹24,000 | 115 ₹23,000 | 140 ₹28,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIR/MAINT AND REPLACEMENT TO LT DISTRIBUTION SYSTEM SUCH AS CABLES, LT SWITCH GEARS, PANELS AND OTHER ALLIED WORK AT BEG AND CENTRE UNDER AGE E/M-I AT GE (CENTRAL) KHADKI
2025_MES_728201_1
8257/E8 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BEG AND CENTRE area
Class D category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹90,000
Yes
24 Dec 2025
28 Aug 2025
23 Sept 2025
28 Aug 2025
20 Sept 2025
13 Sept 2025
28 Aug 2025 - 4 Sept 2025
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth n. exc 10 sqm on plan for laying of cables,pole foundation,stays etc and getting out in soft loose soil, complete all as specified and as directed.
Description all as per item No 1 above but in soft disintegrated rock.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed .
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and as directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified and as directed. (excavation and earth work shall be measured and paid separately)
Description all as per item No-07 above but of size 50mm outer dia.
Description all as per item No- 07 above but of size 63mm outer dia
Description all as per item No- 07 above but of size 90mm outer dia.
Description all as per item No- 07 above but of size 120mm outer dia.
Description all as per item No- 07 above but of size 200mm outer dia.
Description all as per item No- 07 above but of size 250mm outer dia.
Material and labour for cable route indicator duly embossed ' MES LT CABLE" 1100 volts 80mm dia CI Plate marked on LT Cable bolted with 40x5mm flat iron of height 0.4mtr embedded in PCC 1:3:6 type C2 of size 20x20x30 cm block complete all as specified and as directed.
Dismentling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from overhead conductors / MCCBs /joint boxes for relaying/refixing or carrying to store for Sch of Credit complete all as specified and as directed..
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured, heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, heavy duty cable served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 2 core complete all as specified and as directed.
Description all as per item No. 16 above but 16 sqmm 4 core complete all as specified and as directed.
Description all as per item No. 16 above but 25 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 35 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 50 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 95 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 120 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 185 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 above but 240 sqmm 3.5 core complete all as specified and as directed.
Description all as per item No. 16 here-in-before but 300 sqmm 3.5 core complete all as specified and as directed.
Dismantling steel pole/strut any size complete all as specified and as directed.
Supply and fix steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted below ground level with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long) complete all as specified and as directed.
Supply and fix octagonal hot dip galvanised iron pole, 6m long with base plate, 300mm long weather proof reinforced door opening with junction box mounting arrangement, inbuilt junction box, 'J' shape, EN8 foundation bolt with nuts template including RCC foundation as per manuacturer's design conforming to IS 1786 and cross arm made from 40mm dia GI light grade pipe with mounting plates, nut bolts and washer complete all as specifed and directed. The foundation shall extend above surrounding levels by 200mm complete all as specified and as directed. NOTE :-The contractor should submit manufacturer's foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate.
Dismantling cross arms of MS channels or angles section etc complete, to carrying for credit all as directed.
Material and labour for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and as directed.
Dismantling of ACSR conductor any type any size complete all as specified and as directed.
Material and labour for fixing ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and as directed.
Dismantling insulator any type, any size complete all as specified and as directed.
Material and labour for pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and as directed.
Material and labour for shackle type, porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts, washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and as directed.
Material and labour for loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and as directed.
Material and labour for stay assembly for LT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod , having 7 / 2.25 mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator overall dimensions 90mmx140mm, clearance of hole 25.5mm, shackle & stay clamps made out of 50x6mm MS flat iron, necessary excavation and earth work in soft/loose soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) complete all as specified and directed. including taking out and dismantling old unserviceable stay assembly.
Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-40 meters span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and as directed .
Material and labour for restraining of ACSR conductor of any size of 2 wire 35-40 meters span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and as directed
Material and labour for rigid PVC line spacer, U-shaped, spiral type, suitable for 2 wire, made from high grade PVC material, distance bet phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed.
Material and labour for rigid PVC line spacer, U-shaped, spiral type, suitable for 4 wire, made from high grade PVC material, distance bet phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed.
Material and labour for cutting/trimming of tree branches around 3.00 met distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles complete all as specified and as directed.
Material and labour for heat shrink joint (end joint) indoor / outdoor LT 1100 volts grade 10-16 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink joint (end joint) indoor / outdoor LT 1100 volts grade 25-50 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink joint (end joint) indoor/outdoor LT 1100 volts grade 70-150 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink joint (end joint)indoor/outdoor LT 1100 volts grade 185-300 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core complete all as specified and as directed.
Material and labour for Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core, complete all as specified and as directed.
Material and labour for Heat shrink straight through joint LT 1100 volts grade 185-300 sqmm, 4 core, complete all as specified and as directed.
Supply and fix in replacement MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 400 amps complete all as specified and as directed.
Supply and fix in replacement MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 250 amps complete all as specified and as directed.
Supply and fix in replacement MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 200 amps complete all as specified and as directed.
Supply and fix in replacement MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 160 amps complete all as specified and as directed.
Supply and fix in replacement MCCB, 3 pole, 35 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 200 amps, complete all as specified and as directed.
Supply and fix in replacement MCCB, 3 pole, 35 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 160 amps, complete all as specified and as directed.
Supply and fix in replacement MCCB, 3 pole, 16 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 125 amps, complete all as specified and as directed.
Supply and fix in replacement MCCB, 3 pole, 16 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magneticadjustable type, 100 amps, complete all as specified and as directed.
Supply and fix in replacement MCCB, 3 pole, 16 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic adjustable type, 63 amps, complete all as specified and as directed.
Supply and fix in repair for 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm nominal cross section in service connection complete all as specified and as directed.
Description all as per item no. 60 above but of size 6 sqmm.
Description all as per item no. 60 above but of size 10 sqmm.
Preparation of surfaces of LT RCC/PCC poles and applying two coats of cement base white paint (1st quality) and writing pole No, and Luminious paint Strip upto 1.5 mtr height at an intervals of 30cm each yellow and black strip from the ground level and above coping for 09 mtr LT pole complete all as specified and as directed.
Material and labour for Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground complete all as specified and as directed.
Material and labour for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size complete all as specified and as directed.
Material and labour for bore type chemical Earthing of bore dia 150mm complete with GI electrode of 40mm bore buried in 3 meter depth with ground enhancing backfill compound (Safe ground) , the compound should be highly conductive, Hygroscopic, non magnetic, non corrosive in nature and should have best moisture retaining quality including necessary returning filling in & removal and pvc pit cover including demolishing of existing unsv earthing complete all as specified and directed.
Fabrication ,supply and Installation of glow sign boards of size not less than 6.0 M x 1.0 M x 0.4 M made of ACP Panel sheet of 3mm thick with Blue background over 40' x 40' square tubes with verge letters made of acryclic sheet white in colour and having LED strip only on letters and MES Logo placed on angle iron frame duly welded of size 50X50X5.00 mm thick of height not less than 2 mtr including connecting service cable weather proof 4.00 sq mm 2 core from switch board upto 20 mtr including taking out perished sign boards of any type complete as per sample all as specified and as directed. NOTE :- Sample of glow sign board to be got approved by Engr-in-charge/GE before placing the order.
Material and labour for disconnecting LT cable of any size from structure/pole/ transformer for finding/locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc including excavation and earthwork complete at any location as directed. NOTE :- (a) Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which twice the quoted rate per complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate. (b) jointing kit will be measured seperately in appropriate item in this schedule
Contd from,,..69.00 (f) MCCB 100 Amps, 3 Pole, 25 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing). (g) MCCB 63 Amps, 3 Pole, 10 KA with adjustable thermal & fixed Magnetic settings - 04 Nos (Outgoing). (c) MCB TP 63 Amps B Curve - 02 Nos (Outgoing) (d) MCB DP 63 Amps B Curve - 02 Nos (Outgoing) (e) 65A TP Contactor - 01 No (f) Timer dial type - 01 No. (g) MFM - 01 No NOTE :- LT panel shall be of CPRI approved manufacturer
Contd from,,..70.00 (f) MCCB 250 Amps, 3 Pole, 25 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing). (g) MCCB 125 Amps, 3 Pole, 16 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing). (h) MCCB 100 Amps 3 pole , 10 KA with adjustable thermal & fixed Magnetic settings - 02 Nos (Outgoing) (j ) MCB TPN 63 Amps B Curve - 02 Nos NOTE :- LT panel shall be of CPRI approved manufactures
Disconnecting, dismantling, taking out & removing unserviceable volt meter and Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96mmX96mm with adopter complete with button all as specified and as directed. NOTE :- The rate quoted shall be deemed to including the following:- (i) Control wiring for auxiliary supply 230 Volts AC if required. (ii) Cutting the sheet of the panel to suit with existing panel if required. (iii) Calibration and testing the meter.
Disconnection and removing the U/S timer and Supply and fix install digital timer switch in sheet metal encloser havig the contact rating : 16A AC1 usb key version : EG103E.1 channel weekly cycle 56 adjustment pre recording programme two moudules with impulse and holiday function having the contactors rating all for AC 7A lead only (Coil voltage 230V 50Hz). for remote switch control a power circuit 3 No, 63 A 3 modules complete all as per manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as specified and as directed.
Taking down old unserviceable LT current transformer and supplying, fixing, testing and commissioning of resin cast tap wound LT current transformer for rating 100/5A to 200/5A on LT panel board and connections secondary terminals to ammeter complete all as specified and as directed.
Supply , Installing ,testing and commissioning, weather,vermin proof LT Feeder pillar box of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick CRCA sheet with double door shutter with locking arrangement and mounted on MS channel of mim size 75 x 40mm suitable for operation on 3 phase,4 wire ,415volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete the following - Incoming (i) Aluminium bus bar 200 Amps Capacity - 01 set (04 Nos) (ii) MCCB, 4 Pole, 415 V, 35KA, 315 Amps - 01 No Outgoing
Testing of Earth resistance with an earth megger after disconnecting the same from the equipment in presence of MES representatives for for all electrical equipments and writing earth resistance result on the earth cover with black paint and in a separate earth test register including connecting the same afte testing complete all as specified and as directed.
Supply and fixing in repair , heavy duty aluminium lugs for LT UG cable of size 400 sqmm. complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 240 sqmm complete all as specified and as directed.
Supply and fixing in repair , heavy duty aluminium lugs for LT UG cable of size 185 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 150 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 120 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 95 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 70 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 50 sqmm complete all as specified and as directed.
Supply and fixing in repair , heavy duty aluminium lugs for LT UG cable of size 35 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 25 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty aluminium lugs for LT UG cable of size 16 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty Copper lugs for LT UG cable of size 16 sqmm complete all as specified and as directed.
Supply and fixing in repair, heavy duty copper lugs for LT UG cable of size 10 sqmm
Supply and fixing in repair, heavy duty copper lugs for LT UG cable of size 6 sqmm complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Supply and fix in repair PVC junction box for street lights of size 300x200x105 mm including bus bar/terminal for cable connection with one MCB SP 20 Amps 'C' Curve for street light control, IP-66 protection complete all as specified and directed by Engr-in-Charge. MAKE :- Sintex/Hensel/Neptune
M/S. Niksun Electro-Infra Private Limited (BID ID -3430245)
Om Construction (BID ID -3431220)
SKS Electricals (BID ID -3430652)
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3431041)
Sunhari Electricals (BID ID -3431165)
JP ENTERPRISES (BID ID -3430709)
ASHWAMEDH ENGINEERS (BID ID -3429959)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .