| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.3 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.3 Cr+₹22,598.40 (0.17%)Rejected-Finance | ₹1.3 Cr+₹22,598.40 (0.17%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹1.5 Cr+₹11.7 L (8.71%)Rejected-Finance 126 NARANG COLONY JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | ₹1.5 Cr+₹11.7 L (8.71%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
19 Oct 2021, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-10
ADDN/ALTN TO OFFICE ACCOMMODATION OF DAV SITUATED AT THIRD FLOOR AT P-83 AT CAMERO COMPLEX
2021_MES_471256_1
CEWAC/PAL/T-22/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE (AF) SUBROTO PARK
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) SUBROTO PARK
₹2.4 L
Yes
26 Nov 2021
28 Aug 2021
26 Oct 2021
28 Aug 2021
19 Oct 2021
1 Oct 2021
Amount
B/R AND E/M WORKS
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L Verified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick. cement screed in CM 1:4 and pointed with coloured cement matching with surfaces of tiles as information complete all as specified and directed complete all as specified and directed
All as per item No. 1.02 as above but as on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1-:3) as in backing coat of tiles complete all as specified and as directed.
M&L Verified Ceramic dark shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and joined in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement specified in CM 1:4 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:4 complete all as specified and directed.
All as per item above but in skirting over 10mm thick rendering in cement mortar 1:3 complete.
S& F in repairs Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed.
S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 rnm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of bress, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Demolition of brick work built in CM incl all quoins, pillars etc but excl ashlar facings, dressed stone work and precast concrete complete all as specified and directed by Engr-in-Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc. 6 M mean radius built in CM 1:6 nil complete all as specified and directed.
M&L for brick work with sub class 'B' brick, half brick thick wall built in CM 1:4 straight or curved on plan to any radius with old size bricks.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and sooth (without using extra cement) complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick surfaces or concrete surfaces using WPC even and smooth without using extra cement complete all as specified and directed. Note: WPC will be measured and paid in respective items
Supply only water proofing compound complete all as specificed and directed by Engr-in-Charge.
M&L for rendering 5mm thick in CM (1:3) on concrete surfaces of ceiling, even and smooth without using extra cement complete all as specificed and directed by Engr-in-Charge.
M&L for preparation of new plastered or previously untreated surface of walls, and applying two coats of distemper oil emulsion over a coat of primer and 3mm thick wall care putty on walls complete all as specificed and directed
M&L for preparation of new plastered or previously untreated surface of walls, and applying two coats of cement based paint over a coat of chalk complete all as specificed and directed
M&L for preparation of new plastered or previously untreated surface of walls, and applying three coats of white wash on ceiling complete all as specificed and directed.
Taking down shutter of any description not exc. 1.00 sqm each removing to store alongwith all mongaries and fittings complete all as specified and directed.
S&F factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company. One side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabin shutter and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete all as per directions of Engineer-in- charge, manufacturer's specifications and drawing.
S&F factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company. Plain 18mm thick Celuka PVC ply for Shelf/Partitions/Drawer and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete all as per directions of Engineer-in- charge, manufacturer's specifications and drawing.
S&F 100 mm size Stainless Steel handle complete all as specified and as directed by Engr -in - Charge.
M&L for 50mm magnetic catches and fixed complete all as specified and directed by Engr-in- Charge.
S&F 38 mm size Stainless Steel Piano hinges complete all as specified and as directed by Engr -in - Charge.
Dismantling of aluminium cubicals fixed in ground including hacking out of old glasses, alongwith old partical board fixed with the frame and removal of the materials outside MD land complete all as specified and directed by Engr-in-Charge.
M & L modular workstation of 45mm thick with prelaminated top of 25mm thick as per color approved workstation having glass/fabric/white board partition above the top of the table, with three drower mobile pedestal, keyboard and CPU trolley. Overall size for per seat 1200x600x1200mm. (single trolly) complete all as specified and directed by Engr-in-Charge.
M & L modular workstation L-shape of 45mm thick partition and 25mm thick prelaminated top as per color approved Workstation having glass/fabric/white board partition on the top of the table, with mobile pedestal, keyboard and CPU trolley. Overall size 1500x1500x1200mm, complete all as specified and directed by Engr-in-Charge.
M &L for PVC profile for wall panelling colour/ shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square (size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide -primer, fixed to walls complete all as specified and directed by Engr-in Charge.
M&L for PVC profile corner beading L/T type for wall paneling, colour/shade matching with wall paneling/ complete all as specified and as directed.
Taking down Chowkhats or frames with shutters without taking off shutters from frames exceeding 1.50 Sqm but not exceeding 4.00 Sqm complete all as specificed and directed
All as oer item above but not exceeding 1.50 sqm complete all as specificed and directed
M&L for aluminium powder coated of coloured frame and other accessories suitable section as in fixed partition, door, windows, ventilators and as required , glazing aluminium clips, Aluminium bracing and other fixing aluminium section (minimun thickness of powder coating 50 micorn) all as specified and directed by Engr-in-Charge.
S&F powder coated aluminium as in window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2Nos) suitable handle (1 No) (Thickness of powder coating not less than 50 micron) complete all as specified etc. complete all as specified and directed by Engr-in-Charge.
S & F for powder coated aluminum as in door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, 150mm long aluminium handles 2 Nos ineach door, 100mm aluminium but hinges B-21 03 Nos, anodised aluminium snap beading screws etc. (Thickness of powder coating not less than 50 micron) complete all as specificed and directed by Engr-in- Charge
S&F in repair aluminium deco grills confirming to DG-104 grade complete all as specificed and directed
S&F aluminium anodised barrel tower bolt of extruded section 150mm length complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolt of extruded section 100mm length complete all as specified and directed by Engr-in-Charge.
S&F floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel pin fixed to door, over all length 140 mm complete all as specified and directed by Engr-in-Charge.
S & F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specificed and directed
S&F 12mm thick particle boards prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc complete all as specificed and directed.
S&F brass body mortise lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specificed and directed.
Dismantling of wall and ceiling board including frame work complete all as specified and directed by Engr-in- Charge.
Material and labour for false ceilings using GI snap grid system with rool-formed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling- board, prepainted cement fibre board size 595x595x4mm thick any texture (Lake, Hill, ocean cascade or Electra) suspended from from RCC roof/structural members of soofits angle cleat cut out etc to the required line and shape as per manufacturers recommendations at any height complete all as specified and as directed ,by GE,
S&F in repair false ceiling with 4mm thick ceiling board to match with existing ceiling board complete all as specified and directed.
M&L for point wiring with single core FRLS PVC insulated unsheathed IS-694 marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through and including conduit of size of not less than 20mm including all accessories concealed wiring on wall and surface on ceiling terminated in and including ms sunken box covered with 3mm thick laminated top sheet cover along with provn of earth wire PVC insulated, unseathed, 1100 V grade cable muIti stranded FRLS IS - 694 marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge (Note: Cost of for cutting chaising and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate) of the following
One light point controlled by one switch one way
One Ceilingfan/Exhaust fan/wall fan point controlled by one switch one way
One 3 pin 5 amps socket outlet on indpendent board
One 3 pin 5 amps socket outlet on the same board with other switches.
One bell point controlled by one bell push switch
All as per item No 2 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings, socket or power complete, such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-charge.
S & F piano type switch 1 way 6A, 240 volt AC Complete all as specified and directed.
S&F piano type Socket, 6 A, 2/3 pin 240 volt AC complete all as specified and directed.
S&F piano type Socket 1 way 16 A, 240 volt AC complete all as specified and directed.
S&F piano type Socket, 16 A-2/3 pin 240 volt AC complete all as specified and directed.
S & F bell push piano type 1 way 6A, suitable for 240 volt AC complete all as specified and directed.
Supply and fixing ceiling roses, surface bakelite 65x50mm, 3 terminals 3 Phase, PVC/Polycarbonate body complete all as specified and directed.
Supply and fix MCB DB single pole and neutral with two pin and earth plug and socket 20 Amps compete with one SP MCB 20 Amps fixed flush in wall including cutting chases in wall for fixing DB and making good the disturbed wall surface to match with existing specification complete all as specified and directed.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed 1100 V cable copper conductor of size 04 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded 1100 V copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed. Note: - Two number cable and one number earth wire shall be measured together as one unit length including non mattalic pipe pipe of required dia.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed 1100 V cable copper conductor of size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded 1100 V copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed. Note: - Two number cable and one number earth wire shall be measured together as one unit length including non mattalic pipe pipe of required dia.
M & L for sub main wiring with four single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor 1100V with size 10 Sqmm and drawing through & including Non metallic PVC conduit of suitable size as per IS concealed in wall including 01 runs of earth continuity conductor of size 10 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete . Note: - Two number cable and one number earth wire shall be measured together as one unit length including non mattalic pipe pipe of required dia. Note for item No 3.08 to 3.10:- Rate shall be deemed to included in quoted rate for cutting & chasis making disturbed surface good to match with the existing complete all as specified and directed.
S&F of LED ceiling light 36 watt 2'x2' recess LED, 6000 K luminaire having glare free symmetrical illumination complete all as specified and directed.
Supply and fixing wall mounted box type fitting with LED lamp 4 feet long 20 Watt 230V, LED light fitting connecting up with PVC insulated and overall sheathed copper conductor cable of size 0.50 sqmm from ceiling rose to fitting and testing complete all as specified and directed.
M&L for taking down existing wall mounted fan carefully without damaging of any size from various rooms and to be kept in safe custody and deposited to MES Store complete all as specified and directed.
S&F wall mounting fan 400 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscilation switch and tilt mechanism for upwad and downward adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and directed.
Refixing wall mounting fan of any size all as required at site complete all as specified and directed.
Taking down fan, sealing cable end dismantling blades and removing fan and blades from site and depositing in MES store.
Supply & fixing ceiling fans complete with all blades, down rods, electronic regulator and accessories 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including porvision of flexible coppper cord three core PVC insulated and overall sheathed of size 0.50 sqmm of required lenth from ceiling rose to fan complete all as specified and directed.
M&L for taking down existing exhaust fan carefully without damaging of any size from various rooms and deposit in MES store complete all as specified and directed.
S&F Exhaust fan 250 mm sweep 230 Volt, 900 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and directed.
Supply and fix vertical distribution board made out of CRCA sheet, double door, fixed flush in wall TPN 8 way 415 volts having 200 Amps rated bus bar and dust and vermin proof suitable for MCCB as incomer and MCB as outgoing complete all as specified and as directed by Engineer-in-charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification complete all as specified and directed. Note - MCCB/MCB shall be measured and paid separately.
Supply and fix MCB distribution board with Bus bar 200A , neutral link & earth bar made out of CRCA sheet fixed flush in walls mounting SPN 12 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification complete all as specified and directed.
Supply and fix MCB distribution board with Bus bar 200A, neutral link & earth bar made out of CRCA sheet fixed flush in walls mounting SPN 8 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge including cutting chases in walls for fixing DB and making good the disturbed wall surface to match with existing specification complete all as specified and directed.
S & F of MCCB 3 pole 415 V, adjustable type 125 amps with breaking capacity of 16 KA complete all as specified and directed.
Supply and fixing MCB, single pole, 240 volts, 6 to 32 amps C Curve having breaking cap 10 KA complete all as specified and directed.
Supply and fixing MCB single pole, and neutral, 240 volts, 40 amps C Curve having breaking cap 10 KA complete all as specified and directed.
Disconnecting electrically dismantling and taking down distribution board any type and size incl removing from site and making good disturbed wall surface to match existing specification complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by alternative layers of charcoal dust and common salt, all around upto 15 cm connected to galvanised iron earth strip 25x4 mm thick fixed by means of bolts, nuts and washers of galvanised iron or steel and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto and water pipe 20mm dia GI medium grade with socket including earthwork, PCC chamber in PCC (1:36) type C-2 using 40mm stone aggregate. cast iron cover , funnel and wire mesh all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and directed by Engr-in-charge Notes - (i) GI strip connecting upto test point is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto test point.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burie in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm strip galvanised iron or steel complete all as specified and directed.
M&L for taking down existing smoke detector carefully without disturbing existing fire detection system any type and removing from site.
Re-fixing of smoke detector received from Sr Item No 1 above with accessories and fittings complete all as specified and as directed by Engr-in-Charge.
Supply, installation connecting electrically and testing multisensory detectors Complying with and type certified to EN - 45 Addressable type smoke and heat combination with base with self built intelligence as per IS: 11360 as directed by Enqr-in-Charge.
Supply & commissioning of response indicator for detector on false ceiling all as specified and directed.
Supply, fixed to wall or to drawn through conduit PVC insulated and sheathed armoured cable 2 core x 1.5 sq mm. multistrand copper conductor complete all as specified and directed.
Supply and fix rigid steel conduit welded heavy duty, 25mm dia size, for passing cable including saddle clips, and all connected accessories complete all as specified and directed.
Supply and install wall split units indoor/outdoor copper tube evaporator and condensing unit capacity of 1.5 Ton complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with 4 star rating and EER 3.2. of capacity 1.5 Ton fitted on wall and out door to be fixed on roof/wall at required place including all necessary electrical connections, bolting, nuts, including suitable flexible conduit duly clamped on wall of 3 core copper cable, drain water pipe etc up to 3 mtr all as specified and directed by Engineer -in -Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & design for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 5.0 kVA including fixing on wall and necessary electrical connections all as specified and directed by Engr-ln-Charge.
M&L for sub main wiring with 2 run of 4 sqmm cable and one run 4.0 sqmm earth continuity conductor PVC insulated , unsheathed FRLS cable of multistandard copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete making good disturbed surface to match with existing specification all as specified and directed by Engineer in charge. Note: - Two number cable and one number earth wire shall be measured together as one unit length including non mattalic pipe pipe of required dia.
M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finishing coat of paint for installation of condesning unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
S&F Low density polyethylene pipes (LDPE) 20 mm dia of pressure rating 6 kg/cm2 fixed complete to walls ceilings or in floors etc. including accessories, clamps and fastners complete all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 3 core flexible copper cable of size 2.5 Sq mm 1100 V grade complete fixing on wall by clamping/securing including connections all as specified and as directed by Engineer-in-charge
Hindustan Co.Co
Atish Builders LLP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .