Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.0 CrAccepted-AOC | ₹42.0 Cr | 1 | Accepted-AOC Being the lowest and reasonable tender. |
| 2 | 2₹45.9 CrRejected-Finance | ₹45.9 Cr | 2 | Rejected-Finance Not being the lowest tender. |
| 3 | 3₹47.2 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹47.2 Cr | 3 | Rejected-Finance Not being the lowest tender. |
| 4 | 4₹52.4 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹52.4 Cr | 4 | Rejected-Finance Not being the lowest tender. |
| 5 | 5₹59.2 CrRejected-Finance 203 A GOKUL ARCADE VILE PARLE EAST MUMBAI 400 057 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400057 | ₹59.2 Cr | 5 | Rejected-Finance Not being the lowest tender. |
Tender Value
₹49.4 Cr
EMD Value
₹15 L
Closing Date
17 Mar 2025, 6:00 pmClosed
CE (Navy) Mumbai
Chief Engineer Navy Mumbai Shahid Bhagat Singh Marg, Colaba, Mumbai 400005
ENGINEERING, PROCUREMENT AND CONSTRUCTION (EPC) OF DEFICIENT MARRIED ACCN (96 DUs, G PLUS 12 FLOORS) FOR SAILORS (MCPOs CPOs) AT MUMBAI
2025_MES_694711_2
87949/E8
Open Tender
Civil Works
731 days
Mumbai
As per NIT
10 documents required · 10 mandatory
₹3,000
GE (P) Bhandup
₹15 L
Yes
7 Jul 2025
27 Jan 2025
19 Mar 2025
27 Jan 2025
17 Mar 2025
2 Mar 2025
27 Jan 2025 - 10 Feb 2025
Amount
SCHEDULE 'A' PART- I BUILDINGS & STRUCTURES INCLUDING INTERNAL & EXTERNAL SERVICES AS DEFINED IN ANNEXURE I TO X (EPC)
Design & Construction of new Building (G+12) (08 Nos qtrs in each floor) for 96 Qtrs including, stilt parking for cars & two wheelers, internal services with permanent specification all as specified
SCHEDULE "A" PART-II EXCAVATION & EARTHWORK Total of Sch-'A' Part-II B/F
SCHEDULE "A" PART-III ROAD, HARD STANDING & CULVERT Total of Sch-'A' Part-III B/F
SCHEDULE "A" PART-IV (SEWAGE DISPOSAL) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (SEPTIC TANK) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (SOAKAGE WELL) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-VIII B/F
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-X (MISCELLANEOUS ITEMS)
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Notes: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch'A' part II to part VI shall be measured and paid under this item.
M&L for DWC 150 mm dia pipe made from HDPE high ring stiffness and crush resistance capacity having compression strength not less than 5% of applied deflection load and all as specified in relevant IS 16098 & 14930.
Supply and fix adapter panel rated 11 KV/630 Amps ,3 ph,,with Copper Bus Bar (R-Y-B) for direct bus coupling to the existing RMU(Make ABB) on site with existing VCB in existing sub stn.Note: Copper BUS BAR in the adapter panel shall be directy coupled to the VCB with BUS-to- BUS coupling and not accepted by any cable or through HT fuse and contractor shall visit the site to inspect the RMU for manufacturing the adaptor before placing the order complete all as specified and directed
Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted ,Class 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (MAIN PANEL)
INCOMER i) ACB 4 pole 630 A, EDO, incomer, 415V, 50Hz, 50 KA - 01 No. (Incomer) OUTGOING i) MCCB 4 Pole,250 A, 415V, 36 KA - 3 Nos. (for BBT-1 & BBT-2 + FF PANEL) ii) MCCB 4Pole, 125 A, 415V, 25 KA - 2 No. (APFCP + AMF PANEL) iii) MCB 4 Pole, 63 A, 415V, 16 KA - 2 No. (spare) BUSBAR 1000 A rated copper bus bar with colour coded heat shrinkable sleeve METERING & INDICATION i) Ammeter,Digital type, with suitable CTs - 08 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos iv) Multifunction meter -01
Supply and fixing APFC Panel with MD-XL capaciror and MCCB as incomer (Auto/Manual option) with 125 KVAR with 5 steps (2x12.5 + 2x25 + 50) KVAR Capacity complete all as specifed and directed.
Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted , 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable galley chamber ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (UTILITY PANEL)
INCOMER MCCB 4P 125 A, 36 KA (I/C) OUTGOING i) MCCB 4P 100 A, 25 KA -01 Nos (LIFT PANEL ) ii) MCCB 4P 63 A,25 KA -02 Nos (W/s Panel + SPARE) iii) MCB TPN 40 A - 2 Nos ( stair case+ street lights). iv) MCB SPN 20 A - 1 No ( Pump house). v) timer switch-01 nos BUSBAR 250 Amps copper bus bar with colour coded heat shrinkable sleeve METERING & INDICATION i) Ammeter,Digital type, with suitable CTs - 06 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos iv) Multi function meter with suitable CT's -01 No.
Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted , 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrangement including necessary bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (LIFT PANEL )
INCOMER i) MCCB 100 Amp 4 pole 415 v 25 KA(I/C) OUTGOING ii)RCBO 4P 32 Amps,30mA - 02 Nos iii) RCBO 4P 25 Amps,30mA -02 Nos iv) MCB SPN 32 Amps- M/C room lightinig BUSBAR 200 Amps copper bus bar with colour coded heat shrinkable sleeve METERING & INDICATION i) Ammeter,Digital type, with suitable CTs - 01 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos
Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted , 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (W/s PUMP PANEL )
INCOMER i) MCCB 63 Amp 4 pole 415 v 25 KA(I/C) OUTGOING ii)MCB TPN 40 Amps,30mA - 02 No. iii) FASD starter for 20 HP pump set with protection single phase over load and under voltage, 415V, 50HZ suitable for electric driven pump set - 02 Nos BUSBAR 100 Amps copper bus bar with colour coded heat shrinkable sleeve METERING & INDICATION i) Ammeter,Digital type, with suitable CTs - 01 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos
Supply and fix octogoanal HDGI poles type 410 SP-31 (6 meter long) complete with MCB SP 6 Amp arrangments. GI base plate and finial including PCC foundation and coping complete all as specified and directed.
M&L for 3 Core 1.5 Sq mm size multi stranded copper conductor PVC unsheathed 650 / 1100 Volt Grade drawn in through steel tubular poles, for interconnection of cable looping box to Street Light Fitting complete all as specified and directed.
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 32x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 40 mm bore (Medium grade) all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar,including funnel, wire mesh and 20 mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all as specified and directed.
01 Working + 01 Stand BY Supply and fixing, testing centrifugal pump, electric driven, supplied and installed complete 20HP and including PCC foundation for pump set complete all as specified and directed.
Supply and fixing of auto on-off system for water supply pumping set of 20 HP. GPRS/GSM based Centralized Controlling & Monitoring System for water pumps according to level of water tank with Electric actuator & butterfly valve, cubical Panel fabricated with 1.6 / 2mm thick CRCA/GPSP sheet, suitable for 415volt 50Hz AC complete with control wiring of starter for pumps with Auto-phase sequence corrector and having provision of auto & manual control over, duly powder coated floor /wall mounted type complete with necessary switchgear/ accessories, Micro Processor based RF Module, Transponder / Repeater, GSM Module for SCADA software and tablet/LCD display of water level via Liquid Pressure Transducer all as specified by manufacurer and directed by Engr-in-Charge.
Supply and fixing of auto control valve system for UG sump. GPRS/GSM based Centralized Controlling & Monitoring System for according to level of water tank with Electric actuator & butterfly valve, cubical Panel fabricated with 1.6 I 2mm thick CRCA/GPSP sheet, suitable for 41Svolt 50Hz AC·complete with control wiring of motorized auto control vave of size 80mm dia, with Auto-phase sequence corrector and having provision of suto & manual control over, duly powder coated floor /wall mounted type complete with necessary switchgear/ accessories, Micro Processor based RF Module, Transponder I Repeater, GSM Module for SCADA software and tablet/LCD display of water level via Liquid Pressure Transducer all as specified by manufacurer and directed bv Engr-in-Charge.
FURNITURE
Manufacture & Supply of Almirah Steel Medium, complete all as specified and shown on drawing No. FD-1032.
Manufacture & Supply only Book Case, as per Drawing No. FD-46/237, complete all as specified and directed
Manufacture & Supply only Chair Easy (Set of 3), as per Drawing No. FD-229, complete all as specified and directed
Manufacture & Supply of Chair dining, complete all as specified and shown on drawing No. FD/MAP-II/05.
Manufacture & Supply of Chair verandah, complete all as specified and shown on drawing No. FD - 19/256
Manufacture & Supply of Chair writing, complete all as specified and shown on drawing No. FD-280.
Manufacture & Supply of Charpoy folding IP with hardtop, complete all as specified and shown on drawing No. FD 388(R).
Manufacture & Supply of Charpoy IP Hard top, complete all as specified and shown on drawing No. FD/E6/MAP-II/01.
Manufacture & Supply of Bed Hard, complete all as specified and shown on drawing No. FD/E6/MAP/08(R )
Manufacture & Supply of Peg Table, complete all as specified and shown on drawing No. FD-236/384.
Manufacture & Supply of Shoe Rack Steel, complete all as specified and shown on drawing No. FD/E6/MAP/02.
Manufacture & Supply of Table Bed side, complete all as specified and shown on drawing No. FD/E6/MAP/15(R).
Manufacture & Supply of Table centre, complete all as specified and shown on drawing No. FD 274.
Manufacture & Supply of Table Dining 120x90cm, complete all as specified and shown on drawing No. FD-273.
Manufacture & Supply of Table 900x600 mm w/drawers, complete all as specified and shown on drawing No. FD-283.
Manufacture & Supply of Table dressing gents with mirror, complete all as specified and shown on drawing No. FD/E6/MAP/16.
Manufacture & Supply of Table dressing ladies with stool, complete all as specified and shown on drawing No. FD/MAP-II/07.
MANNING & OPERATION OF LIFTS (REFER ANNEXURE-XI)
Manning & Operation of lifts (Qty-4 Nos) all as provided under subject work by deploying 01 x lift operators in 1st & 2nd shifts and 01 operator in night shift on all days including Sundays and holidays (1st Shift-0600 hrs to 1400 hrs and 2nd Shift-1400 hrs to 2200 hrs and night shift-2200 hrs to 0600 hrs) including taking care of all lifts from any pilferage or damage etc. Period of manning & operation shall be 60 months from the date of completion of the project. (TOTAL number of lift operators required per day are 03 nos.)
11 months after completion of work
11 months after completion of BoQ Sl. item No. 25.02 here-in-before
11 months after completion of BoQ Sl. item No. 25.03 here-in-before
11 months after completion of BoQ Sl. item No. 25.04 here-in-before
11 months after completion of BoQ Sl. item No. 25.05 here-in-before
05 months after completion of BoQ Sl. item No. 25.06 here-in-before
MANNING & OPERATION OF WATER SUPPLY INSTALLATIONS , FIRE FIGHTING INSTALLATIONS & DG SET (REFER ANNEXURE-XIII)
Manning & Operation of Water supply installations, Sub station and DG Set all as provided under subject work by deploying 01 x FGM (Skilled) in 03 shifts of 8 hours each on all days including Sundays and holidays (1st Shift-0600 hrs to 1400 hrs, 2nd Shift-1400 hrs to 2200 hrs and 3rd Shift 2200 hrs to 0600 hrs) including cleaning, daily maintenance, testing onsite water parameters using pH tester, chloroscope, TDS meter etc. Period of manning & operation shall be 60 months from the date of completion of the project. (TOTAL number of FGM/Elect required per day are 03 nos.)
11 months after completion of work
11 months after completion of BoQ Sl. item No. 26.02 here-in-before
11 months after completion of BoQ Sl. item No. 26.03 here-in-before
11 months after completion of BoQ Sl. item No. 26.04 here-in-before
11 months after completion of BoQ Sl. item No. 26.05 here-in-before
05 months after completion of BoQ Sl. item No. 26.06 here-in-before
ANNUAL COMPREHENSIVE MAINTENANCE OF LIFTS (REFER ANNEXURE-XII)
Annual Comprehensive maintenance of Lifts (Qty-04) all as installed under subject work including repairs / replacement, periodic maintenance all as per OEM manual and repair / replacement of parts of fully automatic and repairs of fully automatic electrically operated passenger lift of any make and 16 passengers, 1088kg, total floors of one tower – G+12 speed 2.0 m/sec, SS lift installed in the subject project as per schedules for supply and fixing of total 10 lifts comprising of all devices and accessories throughout for a period of 03 (Three) years including Sundays and holidays after expiry of defects liability period (DLP).
One year after expiry of defects liability period
One year after completion of BoQ Sl. item No. 27.02 here-in-before
One year after completion of BoQ Sl. item No. 27.03 here-in-before
ANNUAL COMPREHENSIVE MAINTENANCE OF WATER SUPPLY INSTALLATIONS FIRE FIGHTING & ALARM INSTALLATIONS & DG SET (REFER ANNEXURE-XIV)
Comprehensive annual maintenance including all repairs / replacement and preventive maintenance / servicing of Complete water supply installations, fire fighting and fire alarm installation and DG set-01 No all as provided & installed under subject work throughout for a period of 03 (Three) years) including Sundays and holidays after expiry of defects liability period (DLP).
One year after expiry of defects liability period
One year after completion of BoQ Sl. item No. 28.02 here-in-before
One year after completion of BoQ Sl. item No. 28.03 here-in-before
ANNUAL COMPREHENSIVE MAINTENANCE OF ELECTRIC SUPPLY WORKS (REFER ANNEXURE-XV)
Annual Comprehensive maintenance including all repairs / replacement and preventive maintenance / servicing of Complete electric works consisting of all switchgears, cables, transformers etc, point wiring, light fittings, ceiling fans, exhaust fans, switches, sockets, modular box and cover plate, MCBs (SP/SPN), DBs, submain wiring and telephone & TV wiring, LT cables, junctions, LT panels, earthing, aviation light, lightning protection, MCCBs, rising bus trunking, tap off boxes etc all as required throughout for a period of 03 (Three) years including Sundays and holidays after expiry of defects liability period (DLP).
One year after expiry of defects liability period
One year after completion of BoQ Sl. item No. 29.02 here-in-before
One year after completion of BoQ Sl. item No. 29.03 here-in-before
B D Raizada Projects Pvt Ltd (BID ID -3259523)
SOOD ASSOCIATES PVT LTD (BID ID -3259617)
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3258322)
PRIME CIVIL INFRASTRUCTURES PVT LTD (BID ID -3264623)
Hirani Enterprises (BID ID -3257625)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid