Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
15 Jun 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
W TENDER
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any of the following (by any Government organizations) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (i) In case of tender for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for (b) (i): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. Any work or set of works shall be considered to be a separate component, only when cost of the component is more than Rs 2 crore each. (b)(iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 2.3.3(a) (ii) of the Tender Document or through subcontractor fulfilling the requirements as per clause 2.3.3 of the Tender Document or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer/Chief Signal &Telecom Engineering in writing.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
S and T work (Indoor and Outdoor signaling works) with modification in existing Electronic Interlocking System of Medha Make EI at Delhi Safdarjung (DSJ) station in c/w provision of yard remodeling in connection with construction of New Platform No. 4 & 5 (Island Platform) at DSJ station in Northern Railway.
570-SIG-PS-TENDER-143
570-SIG-PS-TENDER-143
Open
Works - General
6 Months
New Delhi, Delhi
₹0
₹3.0 L
15 Jun 2026
20 May 2026
1 Jun 2026
168 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,50,56,392.6 | ||
| — | 1.00 | — | — | ||
| "Supply of additional Medha EI make hardware to suit proposed modifications at DSJ station per RDSO guidelines. Supply of all types of racks for relays and EI equipments, fixture mounting arrangements and accessories necessary to make EI system functional. Supply of all type of interface relays used in EI system . Supply of additional accessories necessary to make EI system functional . Note: Other details are included in special conditions of contract. Note: 1. Please give full details of quantities for the station and unit base rates item wise, the total amount of which must be equal to the given LAR of this item in separate annexure in a indicative format given in Annexure IV of vol.II of tender document. The rate quoted in percentage above/at par/below for entire tender shall be applicable for the rates quoted in the annexure IV of vol.II also 2. System design should cater to accommodate additional I/Os in future as per RDSO spec. 3. Other details are included in special conditions of contract. (SIP/TSIP of station is enclosed along with tender document. (Inspection:RDSO- Any sub item which is not inspected by RDSO will be inspected by Consignee)" | — | — | — | 10,99,823.09 | |
| — | 1.00 | — | — | ||
| "Modification in Design, alteration in wiring, installation, testing and Commissioning of Medha Make Electronic Interlocking at Delhi Safdarganj station. This includes Design & verification of Interface circuits Design & Verification of application data GSIM testing Activity of FAT Activity of SAT/Or dual FAT Modification in VDU Layout Supply of AS made documents as per tender condition Validation of existing Data Logger and all other actvity to make complete EI system functional. " | — | — | — | 56,05,000 | |
| — | 2.00 | — | — | ||
| "Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/SandT/CON/4-1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors and fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx5cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires and cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting and description etc. with ISI mark paints. (Inspection: Consignee) " | — | — | — | 40,940.72 | |
| — | 10.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding /cable carrier made of angle ironof Size 35mmX35mmX5mm and flat of size 25mmX3mm as per instructions of engineer at site.The space between two flats will be 25cm or less as per site requirements allthe fixing materials i.e nut, bolt washer, insulators, cement concrete etc will be supplied by the contractyor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint. (Inspection : Site Engineer) | — | — | — | 4,922.4 | |
| — | 30.00 | — | — | ||
| "Wiring of relays in relay room/relay huts as per appd wiring diagrams. All wiring material including resistances and condensers etc. to be supplied by contractor. It also includes dressing, bunching , lacing and fixing of relay bases. (Cables and wires for wiring will be supplied by Railway). (Inspection : Site Engineer) " | — | — | — | 13,548 | |
| — | 5.00 | — | — | ||
| Fabricating, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1" wooden batton fitted all around on the rear and having alluminium angle size of 25.4mmx25.4mmx3.15mm on all four sides as per instruction of Engineer at site. All the materials to be supplied by contractor. (Inspection : Site Engineer) | — | — | — | 12,055.2 | |
| — | 2.00 | — | — | ||
| Supply of anti static mats of size 1 mtr x 0.75mtr& 3mm thickness Inspection : Consignee | — | — | — | 4,000.76 | |
| — | 50.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- detoriorating type low voltage fuse assembly 2Amp/4Amp/10 Amp/16Amp. to suit . Specn. No.IRS: S- 78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev-2 and Amd 2 ) and drg no. 23748 (IRS) Alt.4 or latest. Fuse block shall be suitable for round head type fuses. Rating : 2Amp/4Amp /10 Amp/16Amp'. (Inspection : RDSO) | — | — | — | 9,626.5 | |
| — | 5.00 | — | — | ||
| Supply fixing and wiring of fuse auto changeover system (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Note: Material will be required as per site requirement only..Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc will be supplied by the contractor. Installation to be executed without affecting the functioning of the existing Circuits/Gears (Inspection : RDSO for supply portion and Installation by Site Engineer) | — | — | — | 1,96,150.85 | |
| — | 2000.00 | — | — | ||
| Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : RDSO) | — | — | — | 2,27,920 | |
| — | 40.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee) | — | — | — | 5,800.8 | |
| — | 50.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee) | — | — | — | 904 | |
| — | 50.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee) | — | — | — | 791 | |
| — | 1.00 | — | — | ||
| "Prep. of Station Working Rule Diagram, Cable route plan, Cable core chart, Track jumpering plan, Power supply arrangement plan based on station specific load calculation for indoor and out door , Circuit termination chart, Cable termination chart in relay room ,relay hut (if applicable) and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit history card, Fuse analysis plan , Equipment disposition plan, Track circuit plan, Terminal and Contact analysis chart , Outdoor circuits,pull sheets,goomtie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the Engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of Pen drive (32 GB). (iii) One complete set of tracings.(iv) Design through CAD(v) Drawings in A3 and plans in bigger size (six sets) in folders. (Inspection : SSE/C/DandD)" | — | — | — | 42,623.83 | |
| — | 3000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drg. No.NR/SandT/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide and 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of rooots of trees and bushes. (Inspection : Site Engineer) | — | — | — | 2,32,590 | |
| — | 24000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/SandT/CON/1-1/97A as per instructions of the site Engineer. (Inspection : Site Engineer) | — | — | — | 1,98,000 | |
| — | 100.00 | — | — | ||
| Supply and fixing of G.I. pipe 75mm/80mm dia, 3mm thick as per spec no IS-1239, perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per approved drg. No.Drg. No.NR/SandT/CON/1-4/97.or at ASM office/other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection : Consignee for supply portion and Installation by Site Engineer) | — | — | — | 86,110 | |
| — | 500.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. This includes laying of cables in trench. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. This included laying of cables in trenchless. (Inspection : RITES for supply portion and Installation by Site Engineer) | — | — | — | 9,97,820 | |
| — | 1000.00 | — | — | ||
| All work pertaining to horizontal Directional Drilling (HDD)/Boring and trenchless cabling. It includes supply, transportation and insertion of self lubricated HDPE Pipe and the laying of cable in boring under the track/road by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables is to be crossed. The depth of horizontal boring should be minimum 1 m from rail flange/Road level. This item will be used for track crossing of running lines). This included laying of cables in trenchless. Inspection of HDPE Pipe: RITES | — | — | — | 18,74,670 | |
| — | 40000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/SandT/CON/1-1/97C and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. (Inspection : Site Engineer) | — | — | — | 3,50,800 | |
| — | 60.00 | — | — | ||
| Supply and installation of RFID electronic marker for S&T underground cable wlth progammble memory for saving the user specific data inside the RFID electronic marker memory chip,later recordable by electronic marker locator during locating(1O cm diameter with floating coil to keep detection circuit always Horizontal for better detection) which can be buded to depth of 5ft Placing in trench. Inspection RITES | — | — | — | 1,68,989.4 | |
| — | 1.00 | — | — | ||
| Supply of TEC approved electronic cable marker locator for locating quad / signalling cable as per Tec Spec. no G/TIE-07/01 jun 98 along with latest amendment. Inspection: RITES | — | — | — | 3,03,809.09 | |
| — | 50.00 | — | — | ||
| Fabrication, supply and fixing of cable marker as per RDSO drg no. SDO/Cable Laying /020, dated 31.10.11. The marker shall be fixed at various places of cable route as per instruction of Engg. At site. (Inspection: Site Engineer) | — | — | — | 66,582 | |
| — | 2000.00 | — | — | ||
| Testing and meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable seperately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. (Inspection : Site Engineer) | — | — | — | 28,780 | |
| — | 15.00 | — | — | ||
| Excavation and Casting of Foundation for Single Case Location Box, with mixture of Cement:Sand:Stone aggregate/Chip in 1:3:6 ratio and plastering with mixture of Cement:Sand in 1:4 ratio (with fine sand), contractors own Metal Sheet Ferma of the size mentioned the drawing, cement, anchor bolts, with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Railway Engineer at Site. Single Case as per Drg No.DRG. No.NR/S&T/D&D/02/2024 (Inspection: Site Incharge) | — | — | — | 91,290.15 | |
| — | 15.00 | — | — | ||
| Supply of single app.case steel RE with E type lock and key ward no.42 and handle as per drg. No. RE/SandT/ALD/SK/219/82 and 221/82 with Alt.B. (Inspection : RITES) | — | — | — | 3,48,025.35 | |
| — | 10.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays. Preparation and fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals, fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 63,462.3 | |
| — | 3.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays. Preparation and fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material , catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals,fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 15,663.03 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case single to be used as battery box.(not requiring shelf and hylum of size 910x150x6mm only is reqd.). Preparation and fixing of bakelite hylum sheet 910x150x6mm. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolt sthis includes fixing of fuses, ARA terminal and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material , catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 6,287.98 | |
| — | 8.00 | — | — | ||
| Casting, concreting and curing of foundation of size (670mmx760mm) and 650mm deep as per Drg.No.NR/SandT/CON/2. 8/97 it includes erection of Apparatus case half. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate,bitumen compound and anchor bolt shall be supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. (Inspection : Site Engineer) | — | — | — | 42,618 | |
| — | 8.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/SandT/ALD/SK/220/82 and 221/82 with Alt.B. (Inspection : RITES) | — | — | — | 1,44,576.56 | |
| — | 5.00 | — | — | ||
| Preparation of Apparatus Case half involving wiring of relays. Preparation and fixing of bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals,fuse with base only shall be supplied by the Railways (Inspection : Site Engineer) | — | — | — | 21,185.75 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals, fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 7,161.74 | |
| — | 1.00 | — | — | ||
| Preparation of App. Case half as Battery Box (not requiring shelf and hylum of size 450x150x6mm only is reqd.) Preparation and fixing of bakelite hylum sheet 450x150x6mm Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 2,577.42 | |
| — | 3.00 | — | — | ||
| Alteration of wiring in existing apparatus cases single/half. All materials in connection with alteration in wiring shall be provided by the contractor. Relays, ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer) | — | — | — | 14,289.96 | |
| — | 3000.00 | — | — | ||
| Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S-75/2006 (Rev.2) and IRS drawing No. SA-23741A(Alt.4), SA23745(Alt.5) ,SA-23746 and SA- 23756(Alt.3) . (Inspection : RDSO) | — | — | — | 2,17,320 | |
| — | 4.00 | — | — | ||
| Casting, concreting and curing of foundation for main signal of size (1041mmx1041mm)at bottom and (711mmx711mm) at top and 1750mm deep as per approved Drg. no. NR/SandT/CON/2.1/97 all material such as anchor bolts, cement, coarse sand aggregate to be supplied by contractor. (Inspection : Site Engineer) | — | — | — | 45,562.88 | |
| — | 2.00 | — | — | ||
| Supply of Colour light signal post 3.6mtr and ladder 3.5Mtr and bases as per tech. spec. IRS-S-6-81, Rev-3 or latest . (Inspection : RITES) | — | — | — | 35,829.92 | |
| — | 2.00 | — | — | ||
| Supply of Colour light signal post 4.6Mtr/5.6Mtr and ladder 4.5Mtr/5.5 mtr and bases as per tech. spec. IRS-S-6-81, Rev-3 or latest.(Inspection : RITES) | — | — | — | 39,719.76 | |
| — | 2.00 | — | — | ||
| Supply of 2 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest . Specification no. IRS:S-26/64 Rev 1 or latest. (Inspection : RITES) | — | — | — | 33,477.44 | |
| — | 2.00 | — | — | ||
| Supply of 3/4 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23001 A/M (Adv), Alt-9 or latest and SA- 2302A/M(Adv), Alt 9 or latest respectively. Specification no. IRS:S-26/64 Rev 1 or latest. (Inspection : RITES) | — | — | — | 42,783.96 | |
| — | 2.00 | — | — | ||
| Supply of multi lamp route indicator (LED Single/Double Digit) matrix type from 1 to 19 with white LED housing as per specification. Inspection: Consignee | — | — | — | 1,44,109.64 | |
| — | 2.00 | — | — | ||
| Installation, erection, wiring of 2 aspect color light signal. Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets,ii) Wooden cross arm 1 mtr. x 1 mtr.,iii) MS angle and MS sheet for blanking of ladder,iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (Inspection : Site Engineer) | — | — | — | 5,949.48 | |
| — | 2.00 | — | — | ||
| "Installation, erection and wirng of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder,iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc . This also includes fixing of route indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focussing of signal and route indicators. All items for installation and erection to be supplied by the contractor. Wiring and other fixing material, 'U' bolts will also be supplied by the contractor. (Inspection : Site Engineer)" | — | — | — | 8,472.62 | |
| — | 2.00 | — | — | ||
| Supply of calling-on colour light signal unit with offset bracket 3.5 inches dia. type drg.no.SA 24351-52(Adv) or latest .no.IRS-S-23/88. or latest. (Inspection : RITES) | — | — | — | 8,986.12 | |
| — | 4.00 | — | — | ||
| Installation, erection and wiring of LED lit calling-on/dependent shunt signal /illuminated A marker/ AG marker/ F markers on the same post below main signal on offset bracket. Which also includes fixing of stencil and hoods, wiring and focussing of the signal. Offset brackets, calling on signal/shunt signal complete will be supplied by Railways. U-bolt for offset bracket and wire and wiring material will be supplied by contractor. (Inspection : Site Engineer) | — | — | — | 4,007.88 | |
| — | 2.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C/A markers with complete fittings as per approved Drg. No. NR/SandT/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) and SA 23477(Adv) respectively. (Inspection : Site Engineer) | — | — | — | 1,577.22 | |
| — | 2.00 | — | — | ||
| Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/stop dead boards/GoodsWarningBoard/PassangerWarning Board as per drg. No. NR/SandT/CON/7.4/97 and provisions of SEM. Supply of SLB/BSLB/SB/ calling on boards/stop dead boards/ GoodsWarning Board/ PassangerWarning Board as per approved Drg. No.SA-2373 or latest will be Supplied by the contractor. (Inspection : Site Engineer) | — | — | — | 19,031.06 | |
| — | 4.00 | — | — | ||
| Supply of Electric Point Operating Machine - IRS Type with AC Immunity of 160 VAC, Non Trailable to operate on 110 VDC,143 mm throw with interlocking complete with lock, detector, cable terminal box and slides for lock and detector, Rotary locking as per specification No. IRS-S- 24/2002 with amendment -1 or latest with latest amendments. Tools and Accessories to be supplied as per Clause 20 (With Latest Amendments) of IRS: S 24-2002 or latest with latest amendments. with every 08 Sets rounded off to next higher number. Inspection RDSO | — | — | — | 2,82,233.96 | |
| — | 2.00 | — | — | ||
| Supply of Electrical Point Machine- Non-trailable type, Conforming to RDSO Spec no. IRS.S.24/2002, amendment no.1 or latest with latest amendments with the following parts:- (a) 220 mm Throw with interlocking for Operation of the point as per RDSO Drg. no. S11000 with AC immunity of 160 Volt (RMS), 50HZ. (b) Clamp point lock 60KG for BG as per RDSO Drg no. S-3395A (c)Switch extension Bracket (P-Bracket) and insulation Plates as per RDSO drg. no S- 3591, 3592 & 3593, (d) Detectorrods (Long & Short) as per RDSO drg. no S-3594-95, Lock rods (Long & Short) as per RDSO drg. no S-3596-97 (e)Drop lug as per RDSO drg. no S-3598 including all insulations, accessories and Tools and Accessories to be supplied as per Clause 20 (With Latest Amendments) of IRS: S 24-2002 or latest with latest amendments. with every 04 Sets rounded off to next higher number"" Inspection RDSO" | — | — | — | 1,96,666.66 | |
| — | 4.00 | — | — | ||
| Fabrication and Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per . drg. No. SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required coal Bengal for smithy work, all type of nuts and bolts and ,washers and spring washers ,Lugs as reqd also to be supplied by contractor with each set. (Inspection : Consignee) | — | — | — | 36,420.24 | |
| — | 4.00 | — | — | ||
| Supply of Insulation for 'L' type bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). (Inspection : Consignee) | — | — | — | 1,158.72 | |
| — | 8.00 | — | — | ||
| Supply of Insulation for 'P' bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). (Inspection : Consignee) | — | — | — | 5,844.56 | |
| — | 4.00 | — | — | ||
| "Fixing, wiring, testing and adjustment of point machines as per standard practice. It also includes :- i) Fixing of switch extension 'P' bracket/'D' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, wiring of JB with lock and key as per drawing, provided with terminal strips for cable terminations. iii) Supply and fixing of GI pipes with flange for taking cable in to point machine and jn. Box through gland/GI pipe. iv) Complete installation of point insulation , GI pipe, gland pipe, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation for stretcher bar 90R/52kg/60kg as per . drg.no.SA-23172 (adv.) Alt.1 will be done by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/SandT/CON/7-6/97 and william stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of point machine, ground connections of electric point machine, Jn. box , non insulated GTP and CTP extension plate, and stretcher bar with insulation material shall be made available by the Rlys. (Inspection : Site Engineer)" | — | — | — | 35,620.2 | |
| — | 4.00 | — | — | ||
| Supply and fixing of Spigot for point machines. (Job = Per Pt.M/c) . (Inspection : Site Engineer) | — | — | — | 951.44 | |
| — | 2.00 | — | — | ||
| Supply, installation and wiring complete KLCR and its box in ASM office /LC Gate or fixing in L-Box. Supply of Key Lock Relay(KLCR) type TMA 24V DC with 2F/2B contact configuration with different wards combinations as per RDSO Specificatins RDSO/SPN/219/2016 Ver 1.0, Amd.-1. Supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing and wiring of magneto telephones with all accessories including standard Battery Box and 3 Nos. of 6 I cells as per instructions of the Site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone including standard Battery Box and 3 Nos. of 6 I cells and wiring materials to be supplied by contractor. (Inspection : RDSO for supply portion and Installation by Site Engineer) | — | — | — | 36,093.76 | |
| — | 50.00 | — | — | ||
| — | — | — | 415 | ||
| fixing and wiring Fuse or similar. | : - Supply, tyco/Raychem/Bourn/Fuzetech/Little Site Engineer) | — | 2/4/6A make supply portion and | ||
| — | 20.00 | — | — | ||
| Supply, Installtion and Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No. SDO/RDSO./EandB/001 dated:- 19.09.2008 and Drg No. RDSO/SDO/RDSO./EandB/002 dated:- 19.09.2008 or latest. This includes supply of items as per RDSO-Sig0EnB(GEN)/1/2020 dt 02.05.2025 as per requirement provided by site engineer.The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as seperate earth. (Inspection : RDSO for supply portion and installation by Site Engineer) | — | — | — | 5,05,593.6 | |
| — | 20.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/SandT/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, signal unit, route indicator apparatus case, LC Gate Pedestal, Boom Lock Post, Operating Panel of LC Gate. CT rack / relay racks, other equipments as per the instruction of Engr. at site and IRSEM. Earhting connection location to location,Earth pit to block instrument, CTR/Relay Rack and any other indoor equipment shall be done through cable for which cable shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. ( NR/SandT/CON/6. 3/97), cement, wiring material, nut bolt for connection and mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. (Inspection : RDSO/RITES for supply portion and Installation by Site Engineer) | — | — | — | 69,364.6 | |
| — | 2.00 | — | — | ||
| "Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts,GI pipe pullies,pully stakes wire run from cabin to signal posts etc.All dismantelled matterial to be transported and stacked in the store of SSE/Sig/C/NNO or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.1 Job= 1 Signal) (Inspection : Site Engineer)" | — | — | — | 2,583.48 | |
| — | 4.00 | — | — | ||
| Dismantling and releasing of Point eqpts. which includes all SandT fittings of electrical and mechanical, facing point lock/ hand plunger lock/ lock bar / holding bar/ EPD/ mechanical detecter/ Pt. machine with all attachments. All dismantelled matterial to be transported and stack in the store of SSE/Sig/C/NNO or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.(1 Job= 1 Point). (Inspection : Site Engineer) | — | — | — | 6,002.28 | |
| — | 10.00 | — | — | ||
| Dismantling and releasing of location boxes which includes all SandT fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteriies, track feed chargers and other associated fittings installed therein complete with fittings. All dismantelled matterial to be transported and stack in the store of SSE/Sig/C/NNO or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Location Box). (Inspection : Site Engineer) | — | — | — | 7,386.7 | |
| — | 10.00 | — | — | ||
| Shifting of Apparatus case Single and it includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). (Inspection : Site Engineer) | — | — | — | 42,921.1 | |
| — | 5.00 | — | — | ||
| Shifting of Apparatus case half and it includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). (Inspection : Site Engineer) | — | — | — | 14,203.25 | |
| — | 1.00 | — | — | ||
| Shifting of existing color light signal with foundation along the track to meet the schedule of dimension required in connection with RE modification. (Inspection : Site Engineer) | — | — | — | 22,434.27 | |
| — | 10.00 | — | — | ||
| Earth work for excavation and refilling around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signalls shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front and back side. (Inspection : Site Engineer) | — | — | — | 1,391.6 | |
| — | 10.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. (Inspection : Site Engineer) | — | — | — | 32,749.2 | |
| — | 10.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection : Site Engineer) | — | — | — | 34,005.9 | |
| — | 1.00 | — | — | ||
| "Cleaning , Scrapping , Painting and lettering of all newly installed and existing gears such as signals, point equipment, track circuit equipment with T.C. no on rail app. Cases JB. TL JBs point rodding cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engr. and painting material to be supplied by the contractor. This item also includes writing and painting requirement of all indoor and outdoor gears along with making of all circuit nos. near terminal and terminal boards/track in app. Cases, junction boxes, relay room, SMs room, writing of relay nomenclature fuse nos. and equipment nomenclature as the approved plans and as per provision of IRSEM. (1 Job=1 Station).(Inspection : Site Engineer)" | — | — | — | 24,162.75 | |
| — | 1.00 | — | — | ||
| "Supply of ESM/TCM furniture of Godrej or similar make consisting of the following :- 1. Executive revolving bearing series low back floating chair with normal arms cushioned Chair : 1No. 2. Executive Table size 72x36x30"" with 3 drawers one side, lockers cabinet on other side : 1No. 3. Visitor chair seat and back cushion with high density Foam with plastic PVC handle capsul type Flat pipe duly Painted black : 3Nos. 4. One Steel Almirah of size 48""x30""x17"" with lock and handle arrangement for record keeping at station. (Inspection : Consignee) " | — | — | — | 43,864.84 | |
| — | 2.00 | — | — | ||
| Supply, Fixing and wiring of magneto telephones with all accessories including Standard battery box and 3 nos. of RR cells in the ASM office with crank handle locations/ K-points and interlocked L-xing gates as per instructions of the site Engr. All fixing materials including Standard battery box and 3 nos. Of RR cells to be supplied by the contractor. Inspection : Consignee | — | — | — | 11,135.36 | |
| — | 2.00 | — | — | ||
| Supply and Installation of 10 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP boxes and termination of cables as per specifications, drawing and stipulations of tender documents. . This includes fixing of the same on 1" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /wall . All materials required for fixing and termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. (Inspection : Consignee for supply portion and Installation by Site Engineer) | — | — | — | 2,155.74 | |
| — | 2.00 | — | — | ||
| Supply and Installation of 20 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP boxes and termination of cables as per specifications, drawing and stipulations of tender documents. . This includes fixing of the same on 1" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /wall . All materials required for fixing and termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. (Inspection : Consignee for supply portion and Installation by Site Engineer) | — | — | — | 3,110.98 | |
| — | 5.00 | — | — | ||
| Supply and Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. (Inspection : Consignee for supply portion and Installation by Site Engineer) | — | — | — | 35,792.85 | |
| — | 5.00 | — | — | ||
| Supply and Installation of Thermoshrink jointing kit for 6-Quad cable and PIJF cable for Derivation/ Termination joints at LC Gates/Pump House/different locations as decided by the site Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 and 2 or latest. This includes all materials required for joints.(Inspection : Consignee for supply portion and Installation by Site Engineer) | — | — | — | 41,820 | |
| — | 6.00 | — | — | ||
| Monthly Basis Cab & Taxi Hiring Services - MUV; 3000 km x 364 hours; Outstation. This segment includes vehicles for transport of passenger and material with a seating capacity of 3 besides driver with an open loading capacity in the back for 1 to 1.25 MT. Like 1. Mahindra Bolero Camper 2. Tata Xenon 3. Mahindra Imperio 4. Isuzu Dimax or similar. Propoer log sheet duly signed by user is required for payment. Inspection : Site engineer | — | — | — | 3,33,730.2 | |
| — | 250.00 | — | — | ||
| "Preparation of SWR Translation of SWR from English to Hindi. : Inspection by SSE/C/D&D. " | — | — | — | 5,287.5 | |
| — | 250.00 | — | — | ||
| Typing and Printing One master Copy SET in Hindi. Inspection by SSE/C/D&D. | — | — | — | 5,765 | |
| — | 500.00 | — | — | ||
| Photocopies of Hindi Master Copy Set Inspection by SSE/C/D&D. | — | — | — | 745 | |
| — | 4.00 | — | — | ||
| Spiral Binding of master of SWR & 02 set of photocopies as above including plastic cover. Inspection by SSE/C/D&D. | — | — | — | 218 | |
| — | 10000.00 | — | — | ||
| Loading, Leading & Unloading and transportation of materials from one store/site to other site/store by contractor. (per unit= metric tone/km) | — | — | — | 57,200 | |
| — | 100.00 | — | — | ||
| For Tie Bar Fencing : Excavation of pit to size of 450mmx 450 mm x 450mm and concreting the same with 1:3:6 aggregate 20mm for erecting the tie bar fencing panels, curing and white washing the foundations. | — | — | — | 1,64,500 | |
| — | 8.00 | — | — | ||
| Installation and commissioning of Detection point Installation of complete assembly of Track device unit for entry or exit and track side electronic equipment (if applicable) along with Earthing (as detailed in special conditions) with all materials including drilling of required size holes on rails (if required) for fixing the track devices, taking the cable lead through anti rodent, anti- oxidant and nonflammable propagating type DWC pipe as per IS 14930 Part I or II or latest from track device to location box/mushroom and terminating it on terminals including digging of trench under track upto location/track side unit. (All material required for installation of above equipment are to be supplied by the firm.) | — | — | — | 56,640 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
tenderdocument143.pdf
ATTACHMENT
DSJ20260518_101455.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .