Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹26.9 L+₹63,345 (2.41%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹26.9 L+₹64,582 (2.46%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹28.8 L+₹2.5 L (9.68%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹29.7 L+₹3.4 L (13.1%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹44.9 L
EMD Value
₹89,980
Closing Date
11 Jul 2024, 6:00 pmClosed
CWE KHADKI
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR / RE-WIRING AND REPLACEMENT OF ALUMINIUM CONVENTIONAL LIGHT FITTING DBS METER PANEL AND CONNECTED ITEMS AT OTM /MD ACCN OF OFFICERS /JCO/ORS AT BEG AND CENTRE AND TB-II AREA UNDER AGE E/M -II IN GE (CENTRAL) KHADKI
2024_MES_660862_1
CWE/KKE/TOKEN-125 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KHADKI
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹89,980
Yes
3 Dec 2024
20 Jun 2024
15 Jul 2024
20 Jun 2024
11 Jul 2024
5 Jul 2024
21 Jun 2024 - 27 Jun 2024
Amount
Taking down copper/aluminium point wiring ( light, fan, bell,socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc complete all as specified and directed by Engr-in-Charge.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and directed by Engr-in-Charge.
All as per item No 1 here-in-before but 5 amps socket point independent complete all as specified and directed by Engr-in-Charge.
All as per item No 1 here-in-before but 5 amps socket point on same board complete all as specified and directed by Engr-in-Charge.
All as per item No 1 here-in-before but two way light point controlled by two way switch complete all as specified and directed by Engr-in-Charge.
All as per item No 1 here-in-before but cable of size 2.5 sqmm for one 16 amps socket (Power) point independent complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 1.5Sqmm multistrand PVC insulated unsheathed copper conductor cable multystand FRLS 1100Volt and including PVC concealed conduit ISI marked, wall thickness 2mm medium duty for one light or fan/bell point controlled by one switch including 3mm thick laminated sheet using existing MS/CI sunken box including PVC green insulated 1.5Sqmm solid copper conductor cable contineous earth wire and connecting to earth dollycomplete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 1.5Sqmm multistrand PVC insulated unsheathed copper conductor cable multy stand FRLS 1100 Volt and including PVC concealed conduit pipe ISI marked, medium duty for 2-in-one 5Amp sswitch socket independent including 3mm thick laminated sheet using existing MS/CI sunken box including PVC green insulated 1.5 Sqmm multistranded copper conductor cable contineous earth wire and connecting to earth dolly complete all as spd and directed.
M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfacescomplete all as specified and directed by Engr-in-Charge. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
All as per item No 1above but cable of size 2.5 sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No 1 above but cable of size 4.0 sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No 1above but cable of size 6.0 sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No 1 above but cable of size 10.0 sqmm complete all as specified and directed by Engr-in-Charge.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F bell push piano type one way 240 volt incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F 5 Amp switch piano type single pole two way incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F socket outlet flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 6 amps, 230 v incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F for modular switch 1 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F for modular switch 2 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F for modular Bell push, 5/6 Amps, 1/2 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F formodular socket, 5/6 Amps, 2 moduler multi pin (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F for modular switch 1 way, 16 Amps, 2 module (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
S&F for modular socket, 6/16 Amps, multi pin (ISI marked).complete all as specified and directed by Engr-in-Charge.
S&F modular type fan regulator 120W - 2 module complete all as specified and directed by Engr-in-Charge.
S&F Blanking plate -1 module with frame complete all as specified and directed by Engr-in-Charge.
S&F Blanking plate -2 module with frame complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed.
S&F MCB,TP , 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one complete all as specified and directed by Engr-in-Charge.
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed.
Labour for taking down old unsv DBs 4 way, 6 way &12 way of any sizecomplete all as specified and directed by Engr-in-Charge.
S&F Sheet metal enclosure DBs single door two way, complete all as specified and directed by Engr-in-Charge.
S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way .
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way complete all as specified and directed by Engr-in-Charge.
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way complete all as specified and directed by Engr-in-Charge.
S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way complete all as specified and directed by Engr-in-Charge.
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 waycomplete all as specified and directed by Engr-in-Charge.
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA. complete all as specified and directed by Engr-in-Charge.
S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular of size 300mmX200MM Square sheet incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc.complete all as specified and directed by Engr-in-Charge.
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc complete all as specified and directed by Engr-in-Charge.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc.complete all as specified and directed by Engr-in-Charge.
S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc.complete all as specified and directed by Engr-in-Charge.
S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etccomplete all as specified and directed by Engr-in-Charge.
S&F LED tube rod Retrofit 20 watt retrofit PF 0.9 to replace existing fluorescent tube rod surface mounted and complete rewiring with 0.5 sqmm copper flexible conductor, connecting up to ceiling rosecomplete all as specified and directed by Engr-in-Charge.
S&F industrial box type LED base with prewired suitable for single LED rod 20 watt 4'long. base/fitting any type all as specified and directed. Make :- shakti Cat Part No.-IGP161LT8-16 Or Equivalent in any make.
S&F LED batten fitting ' 2'long, 10 watt,CDL 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos.any type all as specified and directed. Make-Shakti Cat Part No- CCS-103-10-65-SL-HL2-DP-NWH or equivalemt Make complete all as specified and directed by Engr-in-Charge.
S&F LED tube light batten fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos fitting any type all as specified and directed. Make- shakti Cat Part No CCS-10CCS-100-20-65-HL2-DP-NWH or equivalent Makecomplete all as specified and directed by Engr-in-Charge.
S&F LED building security light 30 watt, 230V with lens and toughen glass top complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastenercomplete all as specified and directed by Engr-in-Charge. Make- Shakti Fixture Cat Part No SZPSLMPo30-DDS. or equivalent Make
S&F PDC housing LED Bulk head light energy efficient with opal diffuser, equiped with 2 KV in built surge protection with IP65 protection wall mounted LED 10 watt, 230 V complete with all accessories, connecting up to ceiling rose/connector with 0.5 sqmm two core copper flexible conductor cable complete all as specified and directed by Engr-in-Charge. . Make- Shakti fixture CP No. SZSBHMXo10. or or equivalent Make
S&F in replacement of LED post top lantern 30 watt complete with 40/50 mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm two core copper flexible conductor cable complete all as specified and directed by Engr-in-Charge. . Make: Shakti fixture. Cat part No SZPGPMX040-iss. or equivalent Make
S&F LED fitting the soft round shapes and use of metal and glass create a timeless look that resembles lamps of the pastaesthetically designed frosted glass with chrome finish wall lamp with B27 LED 7 Watt lamp . Make- Jaguar Cat Part No JNL-CHR-MB160275542A or equivalent Make complete all as specified and directed by Engr-in-Charge.
S&F for LED driver of 12 to 40 watt suitable for Panel light fitting .
S&F for LED driver of 15 to 30 watt suitable for LED security light.
Taking down and servicing of ceiling fan 1200/1400 mm sweep and Exhaust fan 250/300mm sweep at site of each qty and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt,and re-assembling the fan and Exhaust fan complete.
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1200/1400 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from the complaint cell of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only.
All as per item No- 61 above but for Exhaust fan 250/300 mm sweep industrial type .
Ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
G.M. Bush bearing for ceiling fan as per existing pattern.
Capacitor AC for 230 volts 50 Hz of capacity 1/1.5 Mfd.
Capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
Capacitor AC for 230 volts 50 Hz of capacity 3.15/4.0 Mfd.
Canopy for ceiling fan as per specified and directed
Metal ceiling fan clamp all as specified and directed
Down rod for ceiling fan as per existing lenght 300mm to 600mm all as per spd and directed.
Blade for 1200/1400 ceiling fan any type
Painting of ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by engr-in-chage
S&F PVC insulated PVC sheathed copper flexiable wire multistrand 1.5 sqmm 3 core, ISI marked
Taking down carefully storage type water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc prefixing the same in position by replacing reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge for geyser of capacity. Note : Non return valve stop cock, PVC/Copper connections cable , thermostat etc shall be measured separately.
25 liters capacity
50 liters capacity
Supply only heating element of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge of capacity ISI Marked : Make : DITZ or equivalent Make
1.5 Kilo Watt Capacity
2.0 Kilo watt capacity
Supply only thermostat rectangle/hexagonal suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge. Make : DITZ or equivalent Make
Supply vertical/ horizontal non return valve (gun metal) of following sizes.:-
(a) Suitable to 15mm bore
(b) Suitable to 20mm bore
S&F in repair innner water container made of SS, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed complete all as specified and directed by Engr-in-Charge.
S&F in repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap complete all as specified and directed by Engr-in-Charge.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450 mm long for cold water all as specified and directed.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450 mm long for hot water all as specified and directed.
M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed complete all as specified and directed by Engr-in-Charge.
S& F meter panel panel floor/mounted on wall, cubical type, compartmentalized dust and vemin proof, indoor installation IP 42 type electrical control panel, including PVC channel 25x45 mm, made out of powder coated CRCA sheet of size 700x700x200 mm (thickness 1.6mm) having an arrangement of fixing the energy meter single phase five number inside the panel and having glasss door to take meter reading without open the panel with an arrangement of incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulatedunsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable sizw of lugs/thimble with locking arragement & one lock including dismentling and taking down old unserviceable meter wooden board and making good to disturbed suffces complete all as specified and as directed by Engineer in charge Make : Krutika electricals or quivalent as approved by GE, The Panel shall comprise the following items ;
(a) 63 Amp MCCB, 4 Pole -01 (incoming) (b) 32 Amp MCB, DP - 05 (outgoing) (c) Spreader Link (d) Busbar and cable outgoing (e) Shunt coil (f) suitable Space for fixing 5 energy meter Note : Rate quoted by contractor shall be inclusive of takind down and refixing the existing meter.
All as per item No 84 here-in-before but with following items all as specified and directed.
(a) 63 Amp MCCB, 4 Pole -01 (incoming) (b) 32 Amp MCB, DP - 04 (outgoing) (c) Spreader Link (d) Busbar and cable outgoing (e) Shunt coil (f) suitable Space for fixing 4 energy meter Note : Rate quoted by contractor shall be inclusive of takind down and refixing the existing meter.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x6 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
M/S kirpan Enterprises (BID ID -3057904)
VP DEVELOPERS AND CONTRACTOR (BID ID -3058053)
Om Construction (BID ID -3057096)
ASHWAMEDH ENGINEERS (BID ID -3058077)
K D Electricals (BID ID -3053362)
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3058233)
ANUSHKA BUILDERS (BID ID -3055422)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .