| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹11.3 L+₹41,139 (3.78%)Rejected-Finance 301 THIRD FLOOR DMRC BUILDING NEW ASHOK NAGAR METRO STATION NEW DELHI 110096 | NEW DELHI | NEW DELHI | DELHI | 110096 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹11.7 L+₹85,289 (7.83%)Rejected-Finance 27 A LELIN SARANI KOLKATA 700013 | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹27,442
Closing Date
18 Sept 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_KCED_PWD
Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_A_3rd_Floor_Kokata_700087
Shifting_of_SHG_and_SE_department_to_Kreta_Suraksha_Bhawan_in_the_premises_Khadya_Bhawan____ Renovation_works_of_AC_system
2020_PWDE_294199_1
WBPWD/EE/09/IR/T/KCED/I of 2020-21
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Khadya Bhawan
Please refer Tender documents.
4 documents required · 4 mandatory
₹27,442
Office_of_EE_KCED_PWD
25 Nov 2020
26 Aug 2020
21 Sept 2020
26 Aug 2020
18 Sept 2020
4 Sept 2020
10 Sept 2020
120 days
Amount
Dismantling of existing 6 HP VRF Ceiling mounted cassette type 6HP indoor unit and Ceiling mounted cocealed type 2.5 HP split unit from its position after dismantling coper pipe line and store the same with carefully as direction by EIC.
Dismantling of existing 2Tr, 1.5 Tr and 1 Tr split AC indoor and outdoor units carefully and store the same as direction by EIC
Dismantling existing 12HP VRF top discharged type outdoor unit from existing position, lfting shifting, re-installation the same another position as direction by EIC, including testing & commissioning the same.(without fabrication and installation of iron structure) (Hitachi make)
Dismantling, lifting, shifting of floor mountated 3.5 Tr tower type AC indoor and outdoor unit.
Reinstallation of above mentioned floor mountated 3.5 Tr tower type AC indoor and outdoor unit, including testing & commissioning the same. (Hitachi make)
Re-installation of 6 HP and 3 HP caset type ceiling mounted concealed split unit with suitable suporting arrengment from ceiling.(Hitachi make)
Re-installation of 2.5 HP metal body ceiling mounted concealed split unit with suitable suporting arrengment from beam to beam of 100x50x50 MS 'C' chanel and welded two end by MS plate fixing on beam with four nos fasnut as direction by EIC(without fabrication & installation of iron srtructure).( Hitachi make)
Supply & Fixing of Al Powder coated continuous grill with out VCD. (make- Premier/ Dynacraft/ Systemeir).
Supply & fixing of flexible canvas connection between indoor Unit and supply grill with necessary fixing accessories as require.
Supply and installation of 3 HP 4way ceiling suspended cassete type indoor Unit with following specification: i) IDU power supply AC single phase,220V-240V, 50 Hz, ii) Nominal cooling Capacity- 27300 BTU/Hr, iii)Maximum Air flow rate - 450 cubec metre per min., iv) Maximum sound pressure level-42db. Indoor unit should be multi speed motor with individual remote control and centralized control,fire reterdent (electronic PCB of indoor unit should be enclosed in Sheet metal box.(Make - Hitachi, as existing out door unit is Hitachi make) Installation have to be done with suitable support from ceiling as direction by EIC.
Supply and installation of 1 HP 4way ceiling suspended cassete type indoor Unit with following specification: i) IDU power supply AC single phase,220V-240V, 50 Hz, ii) Nominal cooling Capacity- 13600 BTU/Hr, iii)Maximum Air flow rate - 250 cubec metre per min., iv) Maximum sound pressure level- 33db. Indoor unit should be multi speed motor with individual remote control and centralized control,fire reterdent (electronic PCB of indoor unit should be enclosed in Sheet metal box.(Make - Hitachi, as existing out door unit is Hitachi make)Installation have to be done with suitable support from ceiling as direction by EIC.
Supply, Installation, Testing and Commissioning of Multikit copper joints including necy. insulation.
Supply and installation of refrigerent Cu pipe minimum thickness 1.15 mm (Make royku/ Mandeep) with nitril rubber tubler insulation (make- Aroflex/Acoflex) as below and all piping have to be properly suported with MS hanger. 25.4 mm OD with 19 mm insulation
22.2 mm OD with 19 mm insulation
19.1 mm OD with 19 mm insulation
15.9 mm OD with 13 mm insulation
12.7 mm OD with 13 mm insulation
9.5 mm OD with 13 mm insulation
6.35 mm OD with 13 mm insulation
Supply and fixing of rigid PVC medium pipe(ISI) complete with fittings and insulated with 6 mm thick closed cell nitril rubber insulation. 32 mm dia
25 mm dia
Supply & fixing 1.1 KV grade coper control cable of size 2 core 1.5 sqmm( Make Finolex, Havels, KEI) through 19mm dia PVC rigid conduit (ISI)
Supply and Fixing of refrigerent Cu pipe of size 3/4" and 3/8" ( Royku/ Mandeep) with nitrile rubber insulation(Aroflex/Acoflex)(for Tower AC indoor to outdoor connection)
Supply and delivery of Hi-Wall Split airconditioner having following specification. Colling Capacity - 3200 Watt minimum, ISEER rating - 3.5, BEE 3 Star or more(2018-19) IS compliance- IS 1391, Refrigerent- R410A/R32, Compressor- Rotary/ Scroll, Eveporator and Condensor coil; Copper, Power supply- 230V 50Hz(Tolerrence as applicable standard)[ Make- Mitsubishi Electric/Hitachi/ TOSHIBA]
Supply and delivery of Hi-Wall Split airconditioner having following specification. Colling Capacity - 5100 Watt minimum, ISEER rating - 3.5, BEE 3 Star or more(2018-19) IS compliance- IS 1391, Refrigerent- R410A/R32, Compressor- Rotary/ Scroll, Eveporator and Condensor coil; Copper, Power supply- 230V 50Hz(Tolerrence as applicable standard)[ Make- Mitsubishi Electric/Hitachi/ TOSHIBA]
Installation, testing & commissioning of Indoor and outdoor units of split type airconditioner.
Supply and laying of refrigerent copper pipe minimum thickness 1.15mm, liquid line 3/8" dia and gas line 5/8" dia(make- Royku/Mandeep) and insulation of copper pipe by nitril rubber insulation tube of minimum thickness 9mm(Make- Aroflex/Acoflex) incl. S&F of 4 core 2.5 sqmm PVC insulated copper wire for connecting indoor and outdoor units also rapping insulation and copper wire with GKB Gold raping tape .
Construction of MS structure for instalation and future maintanance of Acs outdoor units made with MS C-Channel 50x50x75 mm 6mm thick, MS angle 50X50X 6mm thick and 40mmX 6mm thick MS strip incl. grouting in wall and paintings.
JOHNSON CONTROLS HITACHI AIR CONDITIONING INDIA LTD.
ELECTRIC REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .