Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC DUE L1 RATE | |
| 2 | L2₹11.8 L+₹33,823.80 (2.94%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L2 | Rejected-Finance DUE TO HIGHER RATE | |
| 3 | L3₹12.4 L+₹86,213.30 (7.50%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance DUE TO HIGHER RATE | |
| 4 | L4₹12.4 L+₹92,103.30 (8.02%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER RATE | |
| 5 | L5₹12.7 L+₹1.2 L (10.5%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance DUE TO HIGHER RATE |
Tender Value
₹12 L
EMD Value
₹12,000
Closing Date
8 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIR/MAINT OF WATER SUPPLY DISTRIBUTION NETWORK FOR ZONE-IVA, IVB AND ZONE-VI AT LEKHAPANI MIL STN UNDER GE LEKHAPANI
2022_MES_513275_1
8643/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category a (ii)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹12,000
Yes
29 Apr 2022
11 Mar 2022
15 Apr 2022
11 Mar 2022
8 Apr 2022
25 Mar 2022
60 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth ; for foundation, etc. or for taking out/laying of CI/GI pipes etc or for shafts,wells, cesspits,manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Taking down cast Iron /DI water pipe line 80 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints for recovering lead including stacking of serviceable pipes aside complete all as specified and as directed.
Taking down cast Iron /DI water pipe line 100 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints for recovering lead including stacking of serviceable pipes aside complete all as specified and as directed.
Taking down cast Iron /DI water pipe line 150 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints for recovering lead including stacking of serviceable pipes aside complete all as specified and as directed.
Taking down cast Iron /DI water pipe line 250 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints for recovering lead including stacking of serviceable pipes aside complete all as specified and as directed.
Relaying of old serviceable cast iron pipe 80 mm bore obtained from serial Item No. 4 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
Relaying of old serviceable cast iron pipe 100 mm bore obtained from serial Item No. 5 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
Relaying of old serviceable cast iron pipe 150 mm bore obtained from serial Item No. 6 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
Relaying of old serviceable cast iron pipe 250 mm bore obtained from serial Item No. 7 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
M & L for Cast iron pipes of 80 mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches including testing complete all specified and as directed
M & L for Cast iron pipes of 100 mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches including testing complete all specified and as directed
M & L for Cast iron pipes of 150 mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches including testing complete all specified and as directed
M & L for Cast iron pipes of 250 mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches including testing complete all specified and as directed
M & L for cast iron fittings upto 150mm bore of spigot and socketed CI pipes, such as bends (any type, radius and angle), Tappers any type (striaght, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) Collars, Caps and plugs, connecting piece etc complete all as specified and as directed.
M & L for cast iron fittings from 200mm to 300mm bore of spigot and socketed CI pipes, such as bends (any type, radius and angle), Tappers any type ( striaght, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) Collars, Caps and plugs, connecting piece etc complete all as specified and as directed.
M & L for Run lead joints for 80 mm bore cast iron pipes and fittings etc., (Spigot and Sockets) including testing complete all as specified and as directed.
M & L for Run lead joints for 100 mm bore cast iron pipes and fittings etc., (Spigot and Sockets) including testing complete all as specified and as directed.
M & L for Run lead joints for 150 mm bore cast iron pipes and fittings etc., (Spigot and Sockets) including testing complete all as specified and as directed.
M & L for Run lead joints for 250 mm bore cast iron pipes and fittings etc., (Spigot and Sockets) including testing complete all as specified and as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 15 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 20 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 25 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 40 mm to 50 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 80 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 100 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as directed.
Relaying of old serviceable GI pipe 15mm bore obtained from serial Item No. 22 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 20 mm bore obtained from serial Item No. 23 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 25 mm bore obtained from serial Item No. 24 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 40 mm bore obtained from serial Item No. 25 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 50 mm bore obtained from serial Item No. 25 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 80 mm bore obtained from serial Item No. 26 here in before complete all as specified and directed.
Relaying of old serviceable GI pipe 100 mm bore obtained from serial Item No. 27 here in before complete all as specified and directed.
S&F 15 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 20 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 25 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 40 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 50 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 80 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F 100 mm bore GI tubing (medium grade) with all new GI fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing complete all as specified and directed.
S&F in replacement 20 mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms) complete all as specified and directed.
S&F in replacement 25 mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms) complete all as specified and directed.
Supply, install, jointing and testing CI body sluice valve class of size 150 mm bore PN-1.6, ISI marked (as per IS-14846 of 2000) heavy duty with flanged ends with high tensile stainless steel spindle, iron hand wheel and fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us sluice valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
Supply, install, jointing and testing CI body sluice valve of size 100 mm bore class PN-1.6, ISI marked (as per IS-14846 of 2000) heavy duty with flanged ends with high tensile stainless steel spindle, iron hand wheel and fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us sluice valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
Supply, install, jointing and testing CI body sluice valve of size 80 mm bore class PN-1.6, ISI marked (as per IS-14846 of 2000) heavy duty with flanged ends with high tensile stainless steel spindle, iron hand wheel and fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us sluice valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
Supply, install, jointing and testing Non Returing sluice valve of size 100 mm bore fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us Non Returning sluice valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
Supply, install, jointing and testing Non Returing sluice Valve of size 80 mm bore fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us Non Returning sluice valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
Supply, install, jointing and testing cast iron butterfly Valve of size 100 mm bore fixing with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us cast iron butterfly valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge. .
Supply, install, jointing and testing cast iron butterfly Valve fixing of size 80 mm bore with nuts, bolts, washers and rubber gasketsheet for packing including taking out existing us cast iron butterfly valve fixed at any position and depositing in E/M store yard all as specified and directed by Engr-in-Charge.
M & L Brick valve chamber of internal size 1.2 M x1.2M x1.0 M by using brick masonry with 23 cm thick wall in CM 1:6 including earth work excavation in any type of strata,return filling,removal of excess soil and 75 mm thick PCC (1:4:8) foundation type D-2, including 20 mm thick PCC (1:2:4) type B1 as in coping and plastering both internal and external surfaces with 10 mm thick CM ( 1:4) and providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with using 40x40x6mm angle iron frame duly painted with two coast of black bituminous paint over one coat of red oxide primer complete all as directed by Eng-in-charge.
M & L Brick valve chamber of internal size 90 cm x 90 cm x 90 cm by using brick masonry with 23 cm thick wall in CM (1:6), 75 mm thick PCC (1:4:8) foundation type D-2, including 20 mm thick PCC (1:2:4) type B1 as in coping and plastering both internal and external surfaces with 10 mm thick CM ( 1:4) and providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with using 40x40x6mm angle iron frame duly painted with two coast of black bituminous paint over one coat of red oxide primer including taking down old existing valve chamber of any size and necessary earth work excavation in any type of strata,return filling,removal of excess soil complete all as directed by Eng-in-charge.
M & L Brick valve chamber of internal size 60 cm x 60 cm x 80 cm by using brick masonry with 23 cm thick walls in CM 1:6 including earth work excavation in any type of strata,return filling,removal of excess soil and 75 mm thick PCC (1:4:8) foundation type D-2, including 20 mm thick PCC (1:2:4) type B1 as in coping and plastering both internal and external surfaces with 10 mm thick CM ( 1:4) and providing 3.15 mm MS sheet chamber cover double opening arrangement center lock system with using 40x40x6mm angle iron frame duly painted with two coast of black bituminous paint over one coat of red oxide primer complete all as directed by Eng-in-charge.
S&F Gun metal, gate valves, with iron wheel head, suitable for 15 mm bore dia of pipes, Screwed both ends for iron pipe or for union including taking out old one complete all as specified and as directed.
S&F Gun metal, gate valves, with iron wheel head, suitable for 20 mm bore dia of pipes, Screwed both ends for iron pipe or for union including taking out old one complete all as specified and as directed.
S&F Gun metal, gate valves, with iron wheel head, suitable for 25 mm bore dia of pipes, Screwed both ends for iron pipe or for union including taking out old one complete all as specified and as directed.
S&F Gun metal, gate valves, with iron wheel head, suitable for 40 mm bore dia of pipes, Screwed both ends for iron pipe or for union including taking out old one complete all as specified and as directed.
S&F Gun metal, gate valves, with iron wheel head, suitable for 50 mm bore dia of pipes, Screwed both ends for iron pipe or for union including taking out old one complete all as specified and as directed.
M&L for repair the any type leakage from joint,bend and Tee in 25/20 mm dia GI pipe under trench by excavation and providing the new material like nipple , tee, Socket etc as per requirement complete all as specified and directed by Engr-in-Charge. (Excavation, Returning filling and Removal of soil will be measured and paid under respective Items)
M&L for repair the any type leakage from joint,bend, socket, reducer and Tee in 40 mm dia GI pipe under trench by excavation and providing the new material like nipple , tee, Socket etc as per requirement complete all as specified and directed by Engr-in-Charge. (Excavation, Returning filling and Removal of soil will be measured and paid under respective Items)
M&L for repair the any type leakage from joint,bend, socket, reducer and Tee in 50 mm dia GI pipe under trench by excavation and providing the new material like nipple , tee, Socket etc as per requirement complete all as specified and directed by Engr-in-Charge. (Excavation, Returning filling and Removal of soil will be measured and paid under respective Items)
M&L for repair the any type leakage from joint,bend, socket, reducer and Tee in 80 mm dia GI pipe under trench by excavation and providing the new material like nipple , tee, Socket etc as per requirement complete all as specified and directed by Engr-in-Charge. (Excavation, Returning filling and Removal of soil will be measured and paid under respective Items)
Cutting of existing cast iron/DI pipes of the size of 250 mm in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connections complete all as specified and directed. Note :- (a) Excavation/earth work shall be measured and paid seperately under respective item of schedule. (b) Cast iron fittings shall be measured and paid seperately as supply only under respective item of the schedule
Cutting of existing cast iron/DI pipes of the size of 150 mm in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connections complete all as specified and directed . Note :- (a) Excavation/earth work shall be measured and paid seperately under respective item of schedule. (b) Cast iron fittings shall be measured and paid seperately as supply only under respective item of the schedule
Cutting of existing cast iron/DI pipes of the size of 100 mm in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connections complete all as specified and directed. Note :- (a) Excavation/earth work shall be measured and paid seperately under respective item of schedule. (b) Cast iron fittings shall be measured and paid seperately as supply only under respective item of the schedule
Supply, laying, jointing and testing of Ductile iron water mains of the size of 80 mm dia,Class K-7 with spigot and socket ends including rubber gasket joints laid in trenches complete all as specified and directed
Supply, laying, jointing and testing of Ductile iron water mains of size 150 mm dia,Class K-7 with spigot and socket ends including rubber gasket joints laid in trenches complete all as specified and directed.
Supply, laying, jointing and testing of Ductile iron water mains of size 100 mm dia,Class K-7 with spigot and socket ends including rubber gasket joints laid in trenches complete all as specified and directed.
Supply, fixing and testing DI fittings of sizes 80mm to 200mm dia for spigot & socketed or flanged pipes i.e. bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc including taking out Unserviceable complete all as specified and directed .
M & L for taking out sluice valve, refacing, remetaling,regrinding and refixing of 250mm bore dia, complete all as specified and directed:
M & L for taking out sluice valve, refacing, remetaling,regrinding and refixing of 150 mm bore dia, complete all as specified and directed:
M & L for taking out sluice valve, refacing, remetaling,regrinding and refixing of 100 mm bore dia, complete all as specified and directed:
M&L for boring drilling, threading and tapping on existing cast iron mains for size 80 mm to 300 mm bore for connecting 15/20/25/40/50/80 mm bore pipe by fixing on clamp made out of MS flat iron of size 40 x 3 mm made to required shape & size with GI socket duly welded, nut & bolts etc. complete all as specified and directed.
M/S S. P. ENTERPRISE
M/s PRABIR ENTERPRISE
FREEZCON
STANDARD ELECTRIC WINDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .