Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L1 | Accepted-AOC Accepted being Lowest Bid Value | |
| 2 | L2₹19.5 L+₹1.5 L (8.63%)Rejected-AOC VILL PO PS BELLATORE DIST BURDWAN PIN 722 203 WEST BENGAL | BELLATORE | BURDWAN | WEST BENGAL | 722203 | L2 | Rejected-AOC Rejected being L2 Bidder | |
| 3 | L3₹21.3 L+₹3.4 L (19.1%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 Bidder | |
| 4 | L4₹21.4 L+₹3.4 L (19.2%)Rejected-AOC 93 618 A MOHANTA PARA WARD NO 19 PO DIST JALPAIGURI PIN 735101 | JALPAIGURI | WEST BENGAL | 735101 | L4 | Rejected-AOC Rejected being L4 Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in appropriate category. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
REPAIR / MAINTENANCE OF HT INFRASTRUCTURE OF POWER HOUSE NO. 01 AREA UNDER GE PANAGARH
2023_MES_588401_1
8862/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹50,000
Yes
21 Jun 2023
6 Apr 2023
16 May 2023
6 Apr 2023
13 May 2023
29 Apr 2023
Amount
Taking down /Taking out old unsv burnt/punctured/faulty Aluminium cable /HT Pilca cable /Cross linked polyethylene(XLPE)Insulated,sreened,PVC bedded, galvanised steel strip or wire armoured,electric power cables(heavy duty) 11000 volt grade of cross sectional area 95 sqmm X3 core from pole /laid in tranches/through pipe in road crossing / path/drains/ducts/floors/along poles/ceiling/wall/equipments etc and relaying the same after removing the defect including cutting making jointing complete all as specified and as directed by Engrs-in-Charge. Note : (i) Joints, sand cushioning, cable protection, GI Pipe and Excavation and earth work,HT conductor HT cable (XLPE) shall be measured separately. (ii) Road cutting involved during excavation for laying of cable etc. shall be made good as per existing road. Nothing extra shall be paid on this account.
Taking down /Taking out old unsv burnt/punctured/faulty Aluminium conductor HT cable (XLPE) polythene(XLPE) Insulated,sreened,PVC bedded, galvaisised steel strip or wire armoured, electric power cables(heavy duty) 11000 volt grade of cross sectional area 150 sqmm X3 core from pole /laid in trenches/through pipe in road crossing / path/drains/ducts/floors/along poles/ ceiling/wall/equipments etc and relaying the same after removing the defect including cutting making jointing Testing complete all as specified and as directed by Engr-in-Charge. Note : (i) Joints, sand cushioning, cable protection, GI Pipe and Excavation and earth work shall be measured separately. (ii) Road cutting involved during excavation for laying of cable etc shall be made good as per existing road. Nothing extra shall be paid on this accounts.
Taking down cable of any size of 11000 volts grade after excavation for laying of new cable of existing size all as specified and directed. (Rate for new cable is considered in relevant items.)
Supply and laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 150 sq mm., complete all as specified and as directed by Engr-in-Charge. Note : RCC cable route indicator of size 1300x1300x100 mm only wtitten "HT CABLE" in block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 600x450x300 mm for fixing route indicator to be deemed in this item rate.
Supply and laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm., complete all as specified and as directed by Engr-in-Charge. Note : RCC cable route indicator of size 1300x1300x100 mm only wtitten "HT CABLE" in block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 600x450x300 mm for fixing route indicator to be deemed in this item rate.
Supply and laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.complete all as specified and as directed by Engr-in-Charge. Note : RCC cable route indicator of size 1300x1300x100 mm only wtitten "HT CABLE" in block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 600x450x300 mm for fixing route indicator to be deemed in this item rate.
Testing of UG HT Cable by portable HT fault detector(11 KV line) and showing the fault/short circuit distance from either end without excavating UG cable,not exceeding testing for 2 km running cable, complete all as specified and as directed.
Testing of ABC(Ariel Bunch) HT Cable by portable HT fault detector(11 KV line) and showing the fault/short circuit distance from either end, not exceeding testing Satisfactory termination for 2 km running cable including restricting, complete all as specified and as directed.
M&L Cable jointing kit for HT 11 kv (Earthed) cable for out door end termination, Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 70 to 95 sqmm cross sectional area including testing after jointing, fixing in replacement, complete all as specified and as directed.
M &L Cable jointing kit for HT 11 kv (Earthed) cable for out door end termination, Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm cross sectional area including testing after jointing, fixing in replacement, complete all as specified and as directed by Engr-in-Charge.
M & L Cable jointing kit for HT 11 kv (Earthed) cable for in door end termination, Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 70 to 95 sqmm cross sectional area including testing after jointing, fixing in replacement, complete all as specified and as directed by Engr-in-Charge.
M &L Cable jointing kit for HT 11 kv (Earthed) cable for in door end termination, Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm cross sectional area including testing after jointing, fixing in replacement, complete all as specified and as directed by Engr-in-Charge.
M & LCable jointing kit for HT 11 kv (Earthed) cable for Straight through Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 70 to 95 sqmm cross sectional area including testing after jointing , fixing in replacement, complete all as specified and as directed by Engr-in-Charge.
M &L Cable jointing kit for HT 11 kv (Earthed) cable for Straight through Heat shrinkable jointing kit complte with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 150 sqmm cross sectional area including testing after jointing , fixing in replacement, complete all as specified and as directed by Engr-in-Charge.
Excavation in tranches n.exc 1.5 mm vide and n. Exc 1.5 mm depth and getting out in soft/loose/dense soil for cable etc., complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in approved hard/dense soil including spreading, leveling, watering and well ramming in layer each n.exc 25 cm, complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance n,exc 50m and depositing whre directed at a level n,exc 1.5m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed by Engr-in-Charge. (Note : Punned thickness shall be measured.)
Supply & laying un reinforced precast concrete cable cover class HVP, type 1 with peak size 300 mm X 180 mm X 40 mm, complete all as specified and as directed by Engr-in-Charge.
M& L in replacement of dual ratio current transformer 100/50/5 with CT chamber (Seperate core for metering and seperate core protection (class 5P-10), 15VA burden for mettering (class 1.0) including installation testing and commissioning, complete all as specified and as directed by Engr-in-Charge.
M&L Painting of steel and two pole structure for surface such as columns, bracing gantary Ms chanels,angle iron of any size and shape with one coats of synthetic enamel aluminium paint over two coats of red oxide primer after preparation of old painted surface colour code of paint shall be as approved by Engineer-in-Charge, complete all as specified and as directed.
M&L Painting of steel and four pole structure for surface such as columns, bracing gantary Ms chanels,angle iron of any size and shape with one coats of synthetic enamel aluminium paint over two coats of red oxide primer after preparation of old painted surface colour code of paint shall be as approved by Engineer-in-Charge, complete all as specified and as directed.
Restringing of sagged ABC (Aerial Bunch Cable) XLPE HT (11 KV) Cable of Size 185 sqmm 3 Core with help of hydra/ machinery including fixing hanging on MS Clamps, complete all as specified and as directed by Engr-in-Charge. Note : (a) ABC Cable to be rolled and unrolled properly. (b) Rate of Brackets, Clamps, Nut bolts to be catered in this item rate.
M&L for calibration and testing of protection relays of any make or type fitted on 11 KV VCB`s at Power house -1, (detail given below) as per IS and code of practice to ensure NO ERROR including setting for earth fault over current, phase over current with trip time delay in accrodance to feeder load and other parameters of site including synchronizing of the same with MRS outdoor VCBs settings to ensure that fault shall not be travel to nearst source feeder including minor repair, replacement of wiring etc. if required, complete all as specified and as directed by Engr-in-Charge. Note : (i) The setting shall be carried out by only qualified and prior approval shall be obtained from GE. (ii) The calibration shall be carried out each job in a 06 months and relay setting shall be carried out once in a six month as per load and site conditions to avoid any fault travel to next adjacent source breaker and shall be monitored regularly. The calibration and setting must be completed and record shall be maintained by the contractor and submitted to Engr-in-Charge.
M&L for calibration and testing of protection relays of any make or type fitted on 11 KV RMU's/CSS in Power house -1 area as per IS and code of practice to ensure NO ERROR including setting for earth fault, over current, phase over current with trip time delay in accordance to feeder load and other parameters of site ,settings to ensure that fault shall not travel to nearst source feeder including minor repair, replacement of wiring etc. if required, complete all as specified and as directed by Engr-in-Charge. Note : (i) The setting shall be carried out by only qualified and prior approval shall be obtained from GE. (ii) The calibration shall be carried out each job in a 06 months and relay setting shall be carried out once in a six month as per load and site conditions to avoid any fault travel to next adjacent source breaker and shall be monitored regularly. The calibration and setting must be completed and record shall be maintained by the contractor and submitted to Engr-in-Charge.
Supply and fixing in replacement of HT jumper existing two pole/4 pole structure for transformer/termination point /isolation point etc using winding of ACSR Conductor (Weasel to mink) for 11 KV volt line, including two aluminium cable lugs of ACSR Conductor jumper,Nuts and bolts, washer etc. as required at site, complete all as specified and as directed by Engr-in-Charge :-
(a) up to 90 cm long (set of three)
(b) up to 1.2 m long (set of three)
(c) up to 1.5 m long (set of three)
Supply and fixing potential transformer resin cast epoxy with protective enclosure of ratio 11kv/RT3/110V, RT3/110V/RT3 Class1.0/3p, Burden 100va/50va voltage factor 1.2 continuous/1.5 for 30 Seconds. ILV 12/28/75 kvp.Ins class B Ref Std IS : 3156/1992 Drawing No. KE-TP02. one end earthed type with one of HRC fuse on HV Side, complete all as specified and as directed by Engr-in-Charge. Note : Primary Neutral to be solidified earthed including removing of old unserviceable pts.
Filtration of transformer oil through stream line oil filtration plant, extracting the moisture contents and carbon deposits from oil and bringing it to 50 KV dielectric strength including carrying out acidity test /dielectric test before and after filtration, complete all as specified and as directed by Engr-in-Charge.
Supply and fill transformer oil (ISI Marked ) after filtration with 50 to 60 KV dielectric strength filled in transformers / VLE Units complete refixing of top cover and testing, complete all as specified and as directed by Engr-in-Charge. Note : Testing of oil including in quoted rate.
Supply and fill silica gel in the transformer breather assembly, complete all as specified and as directed by Engr-in-Charge.
Supply only jelly for applying on OH conductors, joints etc., complete all as specified and as directed by Engr-in-Charge.
M&L Rewinding of transformer including taking out of transformer by after disconnecting of earthing, HT/LT connection. Transporting and lifting of transformer, mechanical operated crain & Vehical site to civ workshop and after rewinding & repair of transformer. transporting taking down from workshop to site by mechanical operated crain & vehical, Re-connected earthing and HT/LT connection after testing of earthing of cables, testing, commissing of transformer after testing the transformer. Note : (i) Rewinding Wire, Oil gaskit, Sillca gel testing & commessing will be measured and paid seperately. (The rate includes for repairing of any body leakage of transformer by welding or by any other means.) (ii) I & P and minor parts will be arranged by the contractor and cost of there of shall be under to be included in unit rate quated againsted this items.
Shifting of transformer from MES store yard to another site by lifting transformer by mechnical operated crane & Vehicle, Testing of earthing and cables (HT/LT) connected, Testing & commissing of transformer, complete all as specified and as directed by Engr-in-Charge. Note : (i) Transformer oil paid separately under relevent items. (ii) T&P and minor will be arrange by the contractor and the cost there of shall be deemed to be included in the unit rate quoted against this items.
Supply only HT porcilain bushing for transformer capacity upto 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only HT brass stud complete with nut, bolts, washer, complete all as specified and as directed by Engr-in-Charge.
Supply only LT Bushing for transformer capacity 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only LT brass stud for transformer complete with nuts, bolts, washer for transformer cap 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only LT Bushing rod of brass complete with nuts, bolts, washer for transformer cap 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only set of gaskets (Rubberised crok/neoprine) material complete for transformer cap 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply and fix transformer breather assembly with silica gel filled including removing the unserviceable breather suitable for transformer of capacity 63 to 250 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only Oil drain/ filter valve for sutaible size complete for transformer cap 63 to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
M & L for the body surface by scratching the old worn out/peeled off paint with the help of emery paper cleaning and removing oil spot from the bodyof transformerand spray painting ter side with synthetic enameled Grey paint of capacity 63 KVA to 630 KVA and writing with paint, complete all as specified and as directed by Engr-in-Charge. Note : Unit rate quoted against this item shall be deemed to include for writing MES No and SM No on equipment with black paint all as directed by Engr-in-Charge.
Supply and fixing in replacement air break switch gang operated out door and vertical type and use in porcelain pattern (conforming to IS specifications) 11 KV, 400 Amps capacity triple pole mechanically operated suitable for operation from ground level complete with HT insulator 12 Nos channel, GI pipe light grade/ operating rod with pad lock arrangement and out door drop-out expulsion fuse assembly with fuse carrier fitting, complete all as specified and as directed by Engr-in-Charge.
Servicing / overhauling of Air Break switch including jelly of adequate quantity to be spread every moving contact and fixed contact jaw oiling of every moving parts and replacement of following spare parts and setting after replacement :- Note : Spare parts to measured and paid separately.
Moving contact Blade (Knife)
Fixed contact Jaw
Gang insulator
Tinned copper jumper 200A/400A/600A
MS Jumper Carrier 200A/400A/600A
Back connector plate
Supply and fixing in replacement air break switch gang operated out door and vertical type and use in porcelain pattern (conforming to IS specifications) 11 KV, 200 Amps capacity triple pole mechanically operated suitable for operation from ground level complete with HT insulator 12 Nos channel, GI pipe light grade/ operating rod with pad lock arrangement and out door drop-out expulsion fuse assembly with fuse carrier fitting, complete all as specified and as directed by Engr-in-Charge. (use in porcelain type)
Opening and taking out the vacuum circuit breaker 11 KV 400 Amp, type VMX from panel and carry out the general maintenance such as oiling greasing the mechanical parts, motor, gear, lever spring operating rod, cleaning the female contacts, tightening of nuts and bolts, cleaning the male and female contact of panel, oiling the bus bar shutter, checking the AC/DC wiring, circuit including control fuses and circuit jack, on/off push button indicating lamp, voltmeter, ammeter, PF meter, any minor parts needs replacement should be replaced and testing after inserting the VCB in panel, complete all as specified and as directed by Engr-in-Charge :- Note : (i) Unserviceable spare parts will be measured and paid for separately as supply only. (ii) Unit rate quoted against this item also includes labour component required for replacement of unserviceable spare parts. (iii) The contractor shall be check the existing system of 11 KV VCB for installation of VCB parts. The contractor will be to take prior approval from GE.
Supply only trip catch assembly.
Supply only big gear assembly.
Supply only small gear assembly.
Supply only tripping coil 30 V DC Cat Part No IN 54450007-AB.
Supply only closing coil 30 V DC Cat Part No IN 54450007-AB.
Supply only trip shaft.
Supply only closing shaft.
Supply only holding latch assembly.
Supply only power pack 110 V input and 24 V DC.
Supply only power pack 110 V input and 30 V DC.
Supply only power pack 230 V input and 110 V DC.
Supply only power pack fuse 1 to 5 Amp as per existing sample.
Supply only PT fuse 1 Amp, 11 KV as per existing sample.
Supply only HRC fuse link type NSD type FA 02 Amps to 20 Apms, 500 V as per existing sample.
Supply only over current relay as per existing sample.
Supply only breaker control switch as per existing sample.
Supply only indicator switch LED type sutaible for 11KV VCB (R,Y,B, green, white).
Supply only master trip relay as per existing sample.
Supply only digital type ammeter sutaible for 11 KV VCB as per existing sample.
Supply only digital type voltmeter sutaible for 11 KV VCB as per existing sample.
Supply only spring charging motor 220 V AC/DC supply.
Supply only Roller bearing Cat Part No 1VYN 400950-077.
Supply only isolating contacts suitable for 11 KV VCB, 630 Amps rating same to match with existing complete all as directed by Engineer-in-Charge.
HT vaccum interrupted assembly with flex connection suitable for VMX type VCB 630 Amps capacity for RYB phases complete all as specified and as directed by Engineer-in-Charge.
M&L for insulators used in the connection of CT to bus bar for breaker of 11 KV VCB, complete all as specified and as directed by Engr-in-Charge.
Supply & fixing 100 mm bore GI tube, light grade for protection of cable , with all fitting lead in trenches /under road / with wall /in wall /under floor where required and including taking down old unserviceable GI pipe, complete all as specified and as directed by Engr-in-Charge.
Suppl & fixing 80 mm bore GI tube, light grade for protection of cable , with all fitting lead in trenches /under road / with wall /in wall /under floor where required and including taking down old unserviceable GI pipe, complete all as specified and as directed by Engr-in-Charge.
Repairing of locking arrangement devices of GOD with provision of locking arrangement including nuts, bolts, washers & strips, complete all as specified and as directed by Engr-in-Charge.
Lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amps suitable for 6600 Volts including connecting to earth wire 4mm dia GI wire, supplied and fixed, complete all as specified and as directed by Engr-in-Charge.
Supply & fixinig Danger notice plate of size 25cm x 20 cm x 1.60 mm thick of mild steel sheet, vitreous, enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3mm MS flat iron including bolts and nuts of approved size for HT 11000 volts, complete all as specified and as directed by Engr-in-Charge.
Supplying and laying in replacement synthetic rubber mat of 1 mtr x 2 mtr x 19 mm sutaible for 11KV at sub station, complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to and including galvanized strip 32x6 mm by means of GI nuts, bolt, check nuts, welding, washers thimbles, etc as shown in electrical plate No 03 SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe med grade 20 mm bore for watering and 40 mm bore meter long GI pipe light grade for earth strip protection fixed with poles/wall plinth with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc., complete all as specified and as directed by Engr-in-Charge. Note : PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner.
Material and labour for repairing at transformer platform rendering 10mm thick on fair faces of brick work or concrete surfaces using 1:6 cement mortar plaster and including taking down plaster, complete all as specified and as directed by Engr-in-Charge.
S&F self-fusing Ethylene propylene Rubber (EPR) based high-insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage, complete all as specified and as directed by Engr-in-Charge.
Material and labour of 40 mm graded coarse aggregate size on laying in 11 KV yard for insulation and 11/433 volt and existing substation. The contractor shall be before laying clean existing aggregate i.e grass, sand with 350 mm depth etc., complete all as specified and as directed by Engr-in-Charge.
Cutting and cleaning the tree branches around the HT poles/over Head line upto 3 mtr from either side of pole/ over head line and clear the site and throw away the branches to a distance, complete all as specified and as directed by Engr-in-Charge. (Span - Distance between two adjacent poles)
Labour only for surface excavation in soft/loose soil n.exc 30 cm deep and averaging 15 cm deep and cleaning of surrounding of out door electrical installation,2 pole/4 pole structure by cutting vegitation, tree, bushes, grass, etc., and surface dressing, complete all as specified directed by Engineer-in-charge.
M & L cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats of aluminium paint and including dismantling of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge.
M&L for Stay assembly complete comprising thick,ms galvanised stay bow 40 cm long with two nos galvanised thimbles 20mm dia of MS galvanised stay rod 180 cm long complete with & including accessories as shown in electrical plate No 1 of SSR Part-I and including dismantling of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge. Note : Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately.
M&L for steel tubular swaged poles complete with cast iron base plate,finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) and including dismantling of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge. Note : (a) Painting cost of pole to be included in this item rate. (b) PCC, anti claiming device, cross arms, insulator, ACSR conductor and earth work shall be measured and paid separately under relevant item.
Re-Stretching of loosened ACSR over head conductor,GI wire(Per span consisting of any number of wire) of any size by opening the binding from insulators and re-fixing after stretching with proper sag including strengthening of ACSR conductor and re-binding the same on insulators with new binding wire of 14 gauge etc and trimming of tree branches of any size or dia for making 2.5 metre minimum clearance from over head conductor where required, complete all as specified and as directed by Engr-in-Charge.
M&L for painting of steel tubular poles of 09 mtr to12 mtr long of HT, one coat of synthetic enamel paint complete Aluminium colour with alternative yellow and black strip up to 1.5 mtr height from top edge of coping complete including numbering of poles with yellow colour, complete all as specified and as directed by Engr-in-Charge. Note : Black and yellow Strip for tubelar Poles.
M&L for painting of PCC poles of 09 mtr to12 mtr long of HT, yellow and black / Red and Black strip up to 1.5 mtr height from top edge of coping complete including numbering of poles with yellow colour, complete all as specified and as directed by Engr-in-Charge. Note : Black and yellow Strip for tubelar Poles.
M&L for Disc type, porcelain, vitreous, white, brown or green insulator of height 145 mm x 255 mm dia for working pressure 11000 Volts ball and socket type of two in series disc assembly with tension clamp and including taking down of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator of height 150 mm x 150 mm dia of 11000 Volts grade including one galvanized mild steel spindle & nut & two washers and including taking down of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge.
M&L for Loop type insulator, porcelain, vitreous white, brown or green of size 90mm x140mm and clearance of hole 25.5 mm for stay assembly and including taking down of old unserviceable ones, complete all as specified and as directed by Engr-in-Charge.
Supply only new copper wire winding wire for LT winding of transformers with double paper insulation copper winding wire of suitable gauge, size, weight so as to match with the working capacity of transformer and all as per manufacture’s design and specification including providing Class-E insulation and fixing. HT coils in position and connecting electrically in core reassembly including new insulation paper tie road etc. of 63 KVA to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
Supply only new copper wire wound coils for HT winding of transformers with double paper insulation copper winding wire of suitable gauge so as to match with the working capacity of transformer and all as per manufacture’s design and specification including providing Class-E insulation and fixing. HT coils in position and connecting electrically in core reassembling of 63 KVA to 630 KVA, complete all as specified and as directed by Engr-in-Charge.
M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregrate as in couping of pole etc including necessary from work as required, complete all as specified and as directed by Engr-in-Charge.
M&L PCC (1:3:6) type C-2 using 40mm graded stone aggregrate as in foundation for stay set/pole etc including fair finish even and to exposed surface without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L RCC cable route indicator of size 1300x1300x100 mm only wtitten "HT CABLE" in block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 600x450x300 mm for fixing route indicator complete all as specified and directed including taking out old u/s indicator, complete all as specified and as directed by Engr-in-Charge.
Schedule of Credit
KMT INDUSTRIES
BANSAL CONSTRUCTION
SOMIK DAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .