HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIR TO TRANSFORMERDS, HT OH LINES WITH ALLIED WORKS AT NAUSHERA UNDER GE 862 EWS
2021_MES_445572_1
CANO-CWE/RAJ-19/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naushera AOR OF DE 862 EWS
Class E Category b(ii)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹40,000
Yes
5 Aug 2021
25 May 2021
25 Jun 2021
25 May 2021
23 Jun 2021
8 Jun 2021
60 days
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse of serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of earth wire or copper conductor, service feeder or distributor span and kept in safe custody for reuse of serviceable GI wire in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of old unsv PCC poles/struts any size after demolition of PCC foundation and removal from site, complete all as specified and directed.
Taking down old unsv XLPE cable of any description & size from any position, complete all as specified.
HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (earthed) of cross sectional area 95 sq mm 3 core including testing, complete all as specified and as directed.
Taking down old unsv GOD and supply, installation, connecting electrically & commissioning switch air break, gang operated, triple pole mounted on insulators 12 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 400 amps and working voltage 11000 volts all as required at site or directed.
Taking up or down old unsv steel tubing of any size and connection laid in trenches or floors or fixed to walls/poles, complete all as specified and directed.
GI pipe light grade 80 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps of required size, nuts, bolts, washers etc. fixed, complete all as specified.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil, complete all as specified.
Description all as per srl item No 09 above but exceeding 1.5mtr and not exceeding 3mtr depth, complete all as specified.
Removing excavated material (soil) not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in sub bade to poles foundation / Struts and mass concrete, all as specified directed.
PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as foundation of poles / stay assembly and as in floor complete all as specified directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in copping of pole with and including necessary form work, complete all as specified.
Steel tubular poles, swaged type, 410 SP-55, 11m long with 300x300x6mm thick MS base plate continuously welded to pole and MS sheet 2mm thick finial tapper plug welded at top, bolts, nuts and screws all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces including painting up to 1.5 mtr height from ground level or above coping with two coats of synthetic enamel paint in 30cm strip, alternate balck & white starting with block at ground level and marking MES pole No with black paint, complete all as specified and directed. (Note:- Excavation and earth work and PCC shall be measured & paid separately)
Stay assembly for electric pole complete with accessories as shown in electrical plate No. 1 of SSR Pt-I and drg using stay rod of 20mm dia including dismantling old unsv stay assemble, complete all as specified. Note : Excavation,earthwork, PCC, stay wire and loop type insulator shall be measured and paid separately.
Stay wire stranded 7/3.15 or 4mm including stay clamp and fixing arrangement complete all as specified.
Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90x140mm, clearance of hole 25.5mm, complete all as specified and directed.
ACSR conductor of any size and any type including stretching, fixing and binding to insulator on OH/ LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified.
Restretching of ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminum wire including re-fixing/re-adjusting line separators, cross arms on poles, all as specified and directed.
Galvanised steel wire 3.15 or 4mm dia asin contenious earth wire/guard or cradle wire made to shape hexagonal/rectangular including binding wire, complete all as specified.
Dismantling cross arms of MS channel or angle section etc complete and setting aside for reuse all as specified and directed.
Cross arms, bracing, supports clamps and back plates, fabricated from structural steel sections incl nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed incl one primer, one under coat and one finishing coat of aluminium paint with and including preparation of steel surfaces, complete all as specified and directed
Fixing only old serviceable cross-arms obtained from ser itm No 25 with providing new bolts, nuts and washers as reqd including painting with one coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the work & removing unserviceable insulator from site complete all as specified & as directed.
Pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified & as directed.
Description all as per item No. 29 above, but fixing only old serviceable pin type insulator as obtained from item No 28 here-in-before after through visual checking and testing with HT megger all as directed by Engr-in-Charge.
All as per item No. 29 here-in-before, but for 33000 volt grade all as directed by Engr-in-Charge.
Disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 11000 volts, complete all as specified & as directed.
Description all as per item No. 32 above but fixing only old serviceable single disc assembly as obtained from item No 28 here-in-before after thorough visual checking and testing with HT megger all as directed by Engr-in-Charge.
Description all as per item No. 32 here-in-before, but for 33000 volt grade, complete all as directed by Engr-in-Charge.
GI pipe light grade 80mm bore laid in trench under road/foot path or fixed on pole with necessary clamps with nut & bolts etc complete all as specified & as directed.
Earthing complete with galvanised steel plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) connected to galvanized earth wire 4 mm dia by means of nuts, bolts, check nuts and washers of galvanized iron strip or steel all as shown in electrical plate No 5 connected to earthing test point including necessary earth work and PCC (1:3:6) type (using 20 mm graded stone aggregate) pit and CI cover and protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I including testing on completion and taking out old unserviceable earthing complete all as specified and directed. Note No:- Please note that rate for Earth wire and GI protection pipe upto 7.5 m are inclussived in the rate to be quoted by the contractor against this item.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron earth lead strip 32x6mm by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 40mm bore including GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 8mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including testing on completion, complete all as specified and directed. Note No:- Please note that rate for Earth strip and GI protection pipe upto 7.5 m are inclussived in the rate to be quoted by the contractor against this item.
Supply and topping up of transformer oil of dielectric strength not less than 40 KV in the transformer / Voltage stabilizer installed at site in various location under Nowshera garrison complete all as directed .
Draining out of transformer oil from floor mounted 11/.433 KV transformer and de hydrating the same using centrifuzing machine till its die electric strength reach 60 KV and filling the same into transformer complete all as directed by Engr in Charge Note:- i) The contractor shall provide elect supply (DG set) for running centrifuzing machine. Cost of centrifuzing machine shall be inclussived in rate to be quoted by the contractor. ii) The transformer oil shall be tested with transformer oil die electric strength testing equipments before and after de hydration of the transformer oil.
Painting of transformer indoor/ outdoor on plinth/ pole with one coat of synthetic enamel gray paint from compressor spray Gun after removing all dust, rust. Paint shall confirmed to IS-2032 and writing SM & MES No of size 2” long by painter with white paint as directed by EIC for following capacity of transformer ;-
25 KVA to 100 KVA transformer
200 KVA to 300 KVA
Painting to old painted HT poles, 11m high with two coats of synthetic enamelled paint including scrapping the old paid carefully to make smoothen complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30cm height all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified.
Cable jointing kit for 11 KV (earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified.
Lightening arrester expulsion type complete with all fittings transmission class , discharge capacity 65 kilo Amps suitable for 11000 Volts complete all as directed by Engr in Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed.
Testing calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and re-setting of relay and proper alignment mechanical system through authorised dealer for smooth functioning and VCB should be tripped at any type of fault developed in feeders complete all as specified and directed by Engr in Charge. Note :- (a) Contracor will submit primary and secondary test record at the time of calibration of HT VCB duly signed by the technical. (b) replacemnt of unservicable item will be measured and paid separatly under relevent item here in after.
Supply only 1250 Amp Voacume interupter Make - Electric feild / ABB/ CG
Supply only AM 96 x 96 mm with MS plate with accuracy 1.00 with CTs. Make - Electric feild / ABB/ CG / Schneider
Supply only VM 96 x 96 mm with MS plate with accuracy 1.00 with CTs. Make - Electric feild / ABB/ CG / Schneider
Supply only Spring charging motor 80W,220V, AC/DC Make - Electric feild / ABB/ CG / Schneider
Supply only LED lamp 30 V DC.
Supply only breaker control switch as per existing type/ make.
supply only Master trip relay. Make -Ashida/ Schneider/ABB
Supply only Limit switch. Make - Electric feild / ABB / CG / Schneider
Supply only Drive insulator. Make - Electric feild / ABB / CG / Schneider
Supply only copper Bus bar as per existing suitable size / capacity.
Opening of complete 11000 volts/440 volts step down transformer outdoor/indoor type of capacity 25 KVA to 100 KVA after disconnection & taking down from any posision including draining out transformer oil, removing of sludge from bottom of the tank, dismantling of core and remove HT/LT coil for replacement and re fixing new HT/LT coils including internal connections, refilling of new oil, replacement of top gasket and deficient nuts, bolts and testing complete after repairs, complete all as specified and directed. Note -(a) Re-winding of HT & LT coils and oil shall be measured and paid for separately). The cost of gaskets, nuts and bolts etc will be deemed to be included in this above item quoted rate. (b) Cost of loading/ unloding and transportation of transformer from site to workshop & return back shall be inclussive in the rate to be quoted by the contractor
Description all as per srl item No 58 above but capacity of transformer more than 160 KVA and upto 300 KVA.
Replacement of burnt out /unserviceable transformer HT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
Replacement of burnt out /unserviceable transformer LT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
Replacement of HT bushes with brass stud complete for transformers 11000 volts grade suitable for transformer capacity up to 300 KVA, complete all as specified and as specified and directed by EIC.
Brass stem set (stud) with porcelain insulator, rubber bush of suitable size of length for LT side terminals with brass nuts eight Nos and rubber seals of 250 Amps fixed in repairs, complete all as specified and as directed .
Brass stem set (stud) with porcelain insulator, rubber bush of suitable size of length for LT side terminals with brass nuts eight Nos and rubber seals of 400 Amps fixed in repairs, complete all as specified and as directed.
Opening the old breathing apparatus and removing the old unserviceable silica gel and refilling with new silica gel to the required level to various size of transformers at different locations, complete all as specified and as directed.
Replacement of unsv breather with New breather apparatus set suitable for various transformers of capacity up to 63 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and as directed.
Replacement of unsv breather with New breather apparatus set suitable for various transformers of capacity exc 63 KVA to 100 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and as directed.
Replacement of unsv breather with New breather apparatus set suitable for various transformers of capacity exc 160 KVA to 300 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and as directed.
Lead acid battery (maint free), 2 volts, 100 Ah suitable for battery bank complete all as specified and directed. Make:- Exide/Amaron/Luminous/Sukam
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .