| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC GOALTULI CHARGHATA CHINSURAH DIST HOOGHLY WEST BENGAL PIN 712103 | CHINSURAH | HOOGHLY | WEST BENGAL | 712103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.6 L+₹61,875.52 (5.62%)Rejected-Finance BARABAZAR CHAKANANTA HARIPAL DIST HOOGHLY | HARIPAL | HOOGHLY | WEST BENGAL | 712403 | L2 | Rejected-Finance Higher Amount Quoted | |
| 3 | L3₹12.3 L+₹1.3 L (12.1%)Rejected-Finance 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L3 | Rejected-Finance Higher Amount Quoted | |
| 4 | L4₹12.9 L+₹1.9 L (17.6%)Rejected-Finance VILL P O TINNA P S PANDUA DIST HOOGHLY PIN 712149 | PANDUA | HOOGHLY | WEST BENGAL | 712149 | L4 | Rejected-Finance Highest Amount Quoted |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
8 Jan 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division_Purta_Bhavan_3rd_Floor_Sarat_Sarani_Kodalia_Hooghly_Pin_712123
Supply_installation_testing_and_commissioning_of_Silent_Diesel_generator_set_with_allied_Electrical_installation_work_at_Female_Vagrants_Home_Uttarpara_Hooghly
2020_WBPWD_310945_1
WBPWD/EE/ HED / NIeQ- 25/ 2020-21
Open Tender
Electrical Work/ Equipment
Item Wise
30 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹26,000
17 Mar 2021
24 Dec 2020
11 Jan 2021
24 Dec 2020
8 Jan 2021
24 Dec 2020
120 days
Amount
Supply, delivery at site on foundation & commissioning of 62.5 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine with mannual panel, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure having following specifications :-
ENGINE
Make: Kirloskar/Cummins/Mahindra/Greaves Power/ Ashok Leyland
Engine Type : 4 Stroke Diesel Engine
Rated Output : 79 HP or Higher
Duty : PRIME
Cooling : Liquid Cooled
Cylinder : 3/4
Aspiration : Turbo Charged, Cgarge Air Cooled
Type of Governer : Mechanical/Electronic
Fuel Tank Capacity : Minimum capacity 125 Ltrs. Or Higher
Fuel Consumption at 75% rated Load with Radiator or Fan : 11.65 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 15.13 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make: Kirloskar/Stamford/Greaves Power/Leroy Somer
Rating : 415 V., 3Ph. 50 Hz., 62.5 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 1.5%
Total Harmonic distortion in output waveform : < 2%
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm ) [ Page- 1, Item no.- 2(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Earth work in filling in foundation trench or plinth with good earth in layers Board a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page 1, Item no.3(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling in foundation or plinth by silver sand in layer a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page- 2, Item no.- 4(A) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [ Page- 14, Item no.1 of PWD Schedule of Rates, Volume-I of Building Works, 2017]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.. A)For works in foundation and top of ground floor / upto 4 m i) Tor steel/ Mild steel SAIL/ TATA/RINL. [ Page- 43, Item no.40(a)(i)(I) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth. [ Page- 16, item no.-13(a)-(i) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Plaster (to wall, floor, ceiling etc.) of 10 mm thick with sand and cement with 1:4 cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page- 189, item no.-1(ii)-(c) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m. [ Page- 192, item no.-15 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling of HSD Oil for initial refilling as well as for commissioning incl. Cost of transportation
Extending the exhaust pipe with 200 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / glass wool insulation and chicken net and Aluminium fol covering, with end cap with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC.
a) 200 mm. dia exhaust pipe.
b) Residential type silenser pipe
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 90 mm. dia (Vertical Run).
S&F rain protection canopy.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge MS sheet barrel
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-6 SWG [5(a)(i)/G-2]
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3)]
Electrical Installation work for DG Set
Description of Item
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. [Emergency LT Panel]
Construction Details : All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incomming Switch : (a) 415V 250 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95642 or equivalent cat of SIEMENS/ABB) in open exexution ------- 1 No.
Bus Bar : 500V, 300 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x40 mm x 5 mm + 1x50 mm x 5 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Switches : (a) 415V 160 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95713 or equivalent cat of SIEMENS/ABB) in open exexution - 2 nos. (b) 415V 63 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95421 or equivalent cat of SIEMENS/ABB) in open exexution----1No.
Metering Panel a) Advanced LED Multifunction Meter Digital Type Load Monitor ( Make L&T, Cat No.- WL442011OOOO) - 1 No. b)LED single function Meter ( Make L& T, Model- CAT No.- WL111020OOOO or equivalent)- for ammeter --- 3 nos. c)LED single function Meter ( Make L& T, Model no..WL112020OOOO or equivalent) for voltmeter-- 3 nos. d) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. d) 200/5 Amp ratio C.T (Kappa) --- 3 nos. e) S & F 6 Amp SPMCB(Make-SIEMENS/LT/Legrand)---6 nos.
Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible PVC insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
Earthing :- A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board and brought outside the panel. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 9 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
5 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch as per GS.
On Board [ 3 (i) / E- 20 ]
4.5 mtr. [ 3 (iv) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(6 sqmm)+1 x (4 sqmm) [ 1(y) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Polycab]
3.5 Core 95 Sq mm
3.5 Core 70 Sq. mm
4 Core 50 Sq. mm
4 Core 35 Sq. mm
2 Core 10 Sq. mm
Laying of cable in underground trench as per GS for the following numbers of Cables.
upto 35 sqmm [ 1(a)/ F- 2 ]
Above 35 and upto 185 Sq. mm [ 1(b)/ F- 2 ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Above 35 sqmm to 95 sqmm [ 5(ii)/ F- 3 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
25mm dia [11(a)/F-6]
40mm dia [11(c)/F-6]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
3.5Core 95 Sq. mm [ 7(d)/F4 & 8(b- xviii) /F5]
3.5Core 70 Sq. mm [ 7(d)/F4 & 8(b- xvii) /F5]
3.5 Core 50 Sq. mm [7(c)/F4 & 8(b-vii) /F5 ]
4Core 35 Sq. mm [7(d)/F4 & 8(b- xv) /F5]
2 Core 10 Sq. mm [7(a)/F4 & 8(b- iii) /F5 ]
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall (240V DP with fuse on L&N) (Make-Havells/Standard/HPL)
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc( Make- L&T/Havells/ Siemens).
Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc( Make - HPL/Havells/Standard).
Supply & Fixing Modular type 240 V, 16A, 3 pin plug socket with separate 16 A Modular type switch on sheet metal switch board embedded in wall as per GS. (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) [ 9(b) / E-18]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent make CG / Bajaj / Wipro as approved by E.I.C] incl. 2 no. 18W Master LED Tube
Supply & fixing heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
12"( 300mm ) Speed 920 RPM
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
S & F digital time switch (Make L&T, Cat No-AUTS02DIG00) or equivqlent cat of SIEMENS/Legrand/Crabtree in existing 2 way SS enclosure for controlling Exhaust Fan as per direction of EIC
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-8 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Making holes on brick wall / RCC ceiling 125 mm depth having dia of following sizes :125 mm depth, 100 mm dia. as to GS.[9 / E-3]
Add GST @12% except item no.-10:- Rs.
Add LWC @1% except item no.- 10,15,16,32 & 41 :- Rs.
MUKHERJEE ELECTRICAL STORES
CHANDA CONSTRUCTION
ROYAL ENGINEERS CO-OPERATIVE SOCIETY LTD
stage.html
html • 0.05 MB
technical_584382.pdf
PDF • 0.61 MB
techsummary_584382.pdf
PDF • 0.77 MB
finance_584382.pdf
PDF • 0.50 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_584382.pdf
PDF • 0.48 MB
25.PDF
PDF • 0.97 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .