Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical EXPERIENCE CRITERIA NOT FULFILLED |
Tender Value
Refer Docs
EMD Value
₹14,260
Closing Date
10 Nov 2023, 11:00 amClosed
2IC EXECUTIVE ENGINEER ELECT BSF ACADEMY TEKANPUR
OFFICE OF 2IC EXECUTIVE ENGINEER ELECT BSF ACADEMY TEKANPUR
REPAIR AND MAINTENANCE OF DUCT COOLER DESERT COOLER INSTALLED AT VARIOUS LOCTION KHEL GAON AC DE TRAINEE NTCD EQUITATION WING SOS MESS AND A B C BLOCK OF SI DE TRAINEES)UNDER BSF ACADEMY TEKANPUR
2023_BSF_779290_1
43/5203/NIT/ENGG/ELECT/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BSF ACADEMY TEKANPUR
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹14,260
14 Nov 2023
2 Nov 2023
11 Nov 2023
2 Nov 2023
10 Nov 2023
2 Nov 2023
Amount
Providing and Fixing duct cooler base water tank suitable size made of 20 SWG(gauge) GI sheet including dismantling of the old water tank from duct cooler and fixing new tank with the help of suitable size nuts and bolts complete in all respects as required.
Rewinding of Duct cooler exhaust fan motor (starting and running winding) with all necessary materials. The motor is to be wound taking the no. of turns and pitch etc as it was originally wound with required size super enamelled copper wire with E class insulation materials and making connection etc. as required (scrap/dismantled material will be retained by the contractor)06 months warranty should be given against winding defects)
Replacement of Grass supporting Panel & grass pad (Khas patti & in side grass Suporting MS Jali ) suitable for existing duct Coolers .(set of 04 nos) complete in all respects as required
Replacement of submersible type water pump Suitable for duct cooler (Summer king / CG /CROWN/ISI make)(scrap/dismantled material will be retained by the contractor))12 months warranty should be given against defects)
Replacement of ball bearing of duct cooler including removing old bearing, fixing suitable size new bearing, greasing, reassembling of fan and testing etc as reqd. (scrap material will be retained by the contractor). (SKF/NBC Make)
Replacement of 4/6/8 mfd Epcos/Havells/Tibcon) Capacitor for Exhaust fans including testing etc as required. (scrap material will be retained by the contractor)
Replacement of duct cooler fan blade((300/400/450mm metal blade) of suitable size including testing etc as required. (scrap material will be retained by the contractor)
Painting of Duct cooler with Redoxide paint in installed position of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc as required.
Rewinding of Desert cooler motor (starting an running winding) with all necessary materials. The motor is to be wound taking the no. of turns and pitch etc as it was originally wound with required size super enamelled copper wire with 'E' class insulation materials and making connection etc. as required (scrap/dismantled material will be retained by the contractor)06 months warranty should be given against winding defects)
Replacement of desert cooler fan blade((300/400/450mm pvc blade) of suitable size including testing etc as required. (scrap material will be retained by the contractor)
Replacement of Grass pad suitable for existing desert Coolers .(set of 03 nos) complete in all respects as required.
Providing and fixing PVC elbow set for the water supply for the grass pads
Supplying & drawing of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, (make : Havells/Polycab) 3X1.5 sq mm .
Rewinding of 5 Hp blower motor with all necessary materials i/c replacement of bearings. The motor is to be wound taking the no. of turns and pitch etc as it was originally wound with required size super enamelled copper wire with 'E' class insulation materials and making connection etc. as required (scrap material will be retained by the contractor).
Replacement of Honey comb Panel/pad 6-8" thick of approx Size 120 cm x 120 cm suitable for existing industrial duct Coolers complete in all respects as required
Replacement of Honey comb Panel/pad 6-8" thick of duct Cooler Size 180 cm x 150 cm suitable for existing industrial duct Coolers complete in all respects as required
Replacement of V-belts no. B 1745Lp/B 67 installed in duct coolers including removing old bearing, fixing suitable size new bearing, greasing, reassembling of fan and testing etc as reqd. (scrap material will be retained by the contractor). (SKF/NBC Make)
Fabrication of motor foundation with material of suitable size after removing the damaged surface/base
Supply & installation of rocker type MPCB for 3 phase, 5 Hp motor of 6.3 to 10 A rating Make L&T/Scheinider/seimens
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .