Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹28.8 L+₹6.3 L (28.2%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹33.2 L+₹10.7 L (47.4%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹35.4 L+₹12.9 L (57.5%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹36.5 L+₹14.0 L (62.3%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
16 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
CA NO GE/C-32/2021-22 PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2021_MES_461248_1
GE/C-32/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt-10
₹94,000
Yes
6 Oct 2021
19 Jul 2021
23 Aug 2021
19 Jul 2021
16 Aug 2021
4 Aug 2021
19 Jul 2021 - 3 Aug 2021
60 days
Amount
Taking down carefully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete including (fittings and fixtures such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc complete all as specified and directed by Enginer-in-Charge.
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed by Engineer-in-charge.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed by Engineer-in-charge.
M&L for point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor drawn through and including non metalic rigid new PVC conduit 20mm dia medium grade ,ISI marked including all accessories concealed in ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth complete all as specified and directed by Engineer-in-charge for following :
One light/fan/bell point controlled by one by one way switch
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
M&L for point wiring complete with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts drawn through and including non metalic rigid new PVC conduit 20mm dia medium grade ,ISI marked including all accessories concealed in new M S steel terminal boxes fabricated branded modular metal fluse box duly make embossed, concealed in wall with suitablemodular inner and outer plate including one run of using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified and directed by Engineer-in-charge.
M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 2.5 sqmm for earth wire in and including medium grade 20 mm dia PVC concealed conduit with all fittings complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire Note:- Two runs of 6 Sqmm cable & one run of 4 Sqmm shall be measured as one length complete all as specified and directed by Enginer-in-Charge..
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire.Note:- Two runs of 10 Sqmm cable & one run of 6 Sqmm shall be measured as one length complete all as specified and directed by Enginer-in-Charge..
M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified and directed by Engineer-in-charge..
M&L switch piano flush type 15 Amp SP one way ISI marked complete all as specified and directed by Engineer-in-charge..
M&L socket outlet 5 pin 5 Amp flush type ISI marked complete all as specified and directed by Engineer-in-charge..
M&L socket outlet 2 in 1,3 pin 5/15 Amps ISI marked complete all as specified and directed by Engineer-in-charge..
M&L ceiling rose 3 phase PVC polycorbonate,isolated body with three terminals . complete all as specified and directed by Engineer-in-charge.
S & F electronic fan regulator 5 step ISI marked connecting complete all as specified and directed by Engineer-in-charge..
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed by Engineer-in-charge.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer-in-charge.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623 complete all as specified and directed by Enginer-in-Charge..
M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting complete all as specified and directed by Enginer-in-Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer-in-charge.
M&L MCB SPN 40 Amp "C " curve complete all as specified and directed by Engineer-in-charge.
M&L MCB SP 6 to 32 Amp "C" curve complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete. Note:- The above mentioned specification will be verificed through LM 79 & LM 80 report of NABL accoredited lab before supply of lLED fittings.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer-in-charge.Note: The above mentioned specification shall be varified through LM 79 & LM 80 report of NABL accoredited lab before supply of LED fittings complete all as specified and directed by Enginer-in-Charge..
Supply and fix in replacement 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete. Note: The above mentioned specification shall be varified through LM 79 & LM 80 report of NABL accoredited lab before supply of LED fittings complete all as specified and directed by Enginer-in-Charge..
supply and fix in replacement recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed by Enginer-in-Charge.
Supply and fix in replacement 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed by Enginer-in-Charge.
S&f exhaust fans metal body AC single phase 230/240 V of size 300 mm sweep, with louvre for fixing of exhaust fan complete all as specified and directed by Enginer-in-Charge.
S&F fresh air fan PVC body AC single phase 230/240 V 50 hzof size 250 mm sweep 1250 rpm, non metallic resin body air delivery >800 CMH 05 Nos of blade single phase and connecting up complete with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Enginer-in-Charge..
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed by Enginer-in-Charge.
M&L for breaking the old existing wall and making provn of a round hole for fixing of 300 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.complete all as specified and directed by Enginer-in-Charge.
M&L bell push,flush type,5 amp complete all as specified and directed by Enginer-in-Charge.
Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all as specified and directed by Enginer-in-Charge
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete or similar works complete all as specified and directed by Enginer-in-Charge
M & L for brick work with sub class 'B' bricks old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Enginer-in-Charge
M&L Hardcore of broken stone boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone ® complete all as specified and directed by Enginer-in-Charge
M&L 75mm thick cement concrete 1:4:8 type D 2 (40mm graded stone aggregate) as in sub base , complete all as specified and directed by Enginer-in-Charge
M&L 100mm cement concrete 1:2:4 type B 2 (20mm graded stone aggregate) as in floor broom finished complete all as specified and directed by Enginer-in-Charge
M&L for rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in CM (1 : 4 ) finished even and smooth without using extra cement complete all as specified and directed by Enginer-in-Charge
Surface dressing averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Enginer-in-Charge
M&L for 22 to 25mm thick rubber moulded ultra tiles laid over and including 15 mm thick screed bed in cm 1:6 and jointed and pointed in white cement mixed with pigment to match the shade of tiles of flooring complete all as specified and directed by Enginer-in-Charge
M & L for providing, cement concrete type B1 (1:2:4 using 20 mm graded aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Enginer-in-Charge
M&L Wire brushing and cleaning top surface of tiles, or cement concrete, including flashings and junction of parapets, etc., cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed by Enginer-in-Charge
M&L for PCC 1:2:4 (using 20mm aggregate) type B-1 as in levelling course for maintaining roof slope using WPC finished even and smooth without using extra cement (WPC shall be measured and paid seperately) complete all as specified and directed by Enginer-in-Charge
M&L for APP based polymeric membrane mineral slate finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints complete all as specified and directed by Enginer-in-Charge
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed by Enginer-in-Charge
Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where complete all as specified and directed by Enginer-in-Charge
M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate). Plinth protection laid to a slope of 1 in 24 in alternate basis system. Each bay shall not exceed 3m in length, 12mm wide & 75mm deep joint shall be formed between the bays which shall be filled with Mastic filling to full depth comprising a mixture of 1 part of heator hot blow bitumen 85/25 portion and two parts of heated badrapur sand (by volume) complete all as specified and directed by Enginer-in-Charge
Note :- Total amount of Sch of credit is Rs.55170.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S ANIL KUMAR
SHREE RAM BUILD TECH
LAMBA ENTERPRISES
S D Constructions
GIAN ENGINEERS
JAIPAL and BROS
ergon enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .