| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC NIRMAL NIKETAN OLD GANGAPUR NAKA GANGPUR ROAD SHREENAGAR NASHIK 422013 | NASHIK | MAHARASHTRA | 422013 | ₹36.2 L Quoted ₹37.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹38.4 LRejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹38.4 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹45.6 LRejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹45.6 L | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹45.7 LRejected-Finance | ₹45.7 L | L4 | Rejected-Finance BEING L4 |
| Sl No | Description | Qty | Unit | Vishal Builders L3 | KRISHNA ENGINEERS L2 | NIKAASH INFRACON L1 | CROSSLINE ENGINEERS AND CONTRACTORS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed. | 200 | Sqm | 25 ₹5,000 | 5 ₹1,000 | 50 ₹10,000 | 60 ₹12,000 |
| 2.00 | M&L for APP modified roof treatment over existing RCC roof with following specification :-
(a) Applying bitumen primer @ 0.4 Litres/Sqm with density of 0.87 to 0.89 Kg/Litres at 25 degree C on the prepared dry roof surface.
(b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane. | 200 | Sqm | 600 ₹1.2 L | 570 ₹1.1 L | 460 ₹92,000 | 590 ₹1.2 L |
| 3.00 | Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified. | 1 | Cum | 3,000 ₹3,000 | 20 ₹20 | 200 ₹200 | 1,600 ₹1,600 |
| 4.00 | M&L for separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) all as directed | 0.3 | Per Quintal | 200 ₹60 | 20 ₹6 | 500 ₹150 | 900 ₹270 |
| 5.00 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. | 2.58 | Cum | 700 ₹1,806 | 20 ₹51.60 | 600 ₹1,548 | 465 ₹1,199.70 |
| 6.00 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. | 5 | Cum | 900 ₹4,500 | 20 ₹100 | 400 ₹2,000 | 680 ₹3,400 |
| 7.00 | M&L for brick work with sub class B bricks , straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed. | 2 | Cum | 6,500 ₹13,000 | 8,000 ₹16,000 | 5,500 ₹11,000 | 6,900 ₹13,800 |
| 8.00 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified. | 5 | Sqm | 800 ₹4,000 | 600 ₹3,000 | 600 ₹3,000 | 1,400 ₹7,000 |
| 9.00 | Taking down cement plaster on brick wall including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. | 250 | Sqm | 30 ₹7,500 | 5 ₹1,250 | 60 ₹15,000 | 27 ₹6,750 |
| 10.00 | M&L for rendering 15mm thick CM 1:4 on brick walls surface or surfaces other than fair face of walls and finished surfaces even and smooth without using extra cement complete all as specified and directed. | 100 | Sqm | 400 ₹40,000 | 220 ₹22,000 | 200 ₹20,000 | 310 ₹31,000 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
9 Sept 2025, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
UPGRADATION OF OMQ P-16 AND P-105 AT AFS MADH ISLAND UNDER GE(AF)THANE
2025_MES_725841_1
GE (AF) T-26 OF 2025-26 (8499)
Open Tender
Civil Works
180 days
THANE
As per NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹83,000
Yes
14 Jan 2026
12 Aug 2025
17 Sept 2025
12 Aug 2025
9 Sept 2025
27 Aug 2025
Amount
Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed.
M&L for APP modified roof treatment over existing RCC roof with following specification :- (a) Applying bitumen primer @ 0.4 Litres/Sqm with density of 0.87 to 0.89 Kg/Litres at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane.
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified.
M&L for separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) all as directed
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
M&L for brick work with sub class B bricks , straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified.
Taking down cement plaster on brick wall including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15mm thick CM 1:4 on brick walls surface or surfaces other than fair face of walls and finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick CM 1:6 on brick walls surface or surfaces other than fair face of walls and finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick CM 1:3 on fair faces of concrete surface in ceiling and finished surfaces even and smooth without using extra cement complete all as specified and directed.
M/L for filling and repairing wall crack by approved manufacturers material crack filler with polymer grout of Asian, fosrock , choksey/ Dr fixite or equivalent manufacturer and making surface smooth applied to parapet ,wall crack , beam column junction , slab junctions to avoid seepage/leakage from external wall surface etc in similar work including making V shape groove to existing cracked surface by chiselling /cutter grinding , cleaning , washing and refilling with crack filler of Asian /pidilite /choksey/equivalent as per manufacturers instructions etc completed and as directed. Note : Rate shall be inclusive of required T&P , scaffolding with all safety measures up to 7m height of building.
M&L for preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of distemper oil emulsion over a coat of 2mm thick wall care putty strictly as per manufacture instruction with smooth roller finish complete all as specified and directed.
M&L for Preparation of new plastered/ rough plastered surfaces of wall and apply two coats of Premium Acrylic emulsion exterior paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified.
M&L for preparation of new plastered or unplastered surfaces of ceiling and apply two coats of distemper oil emulsion over a coat of 2mm thick wall care putty, complete all as specified.
M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 2mm thick wall care putty on walls complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of ceiling and apply one coats of distemper oil emulsion, complete all as specified.
M&L for complete removal of old plastered/ rough plastered surfaces of wall and apply two coats of Premium Acrylic emulsion exterior paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified.
Preparation of old wooden surafces and applying one coats of synthetic enamel paint , complete all as specified.
M&L for providing and injecting chemical emulsion for post constructional ant termite treatment along the external / internal wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron/ floor, complete all as specified.
M&L for providing and injecting chemical emulsion for post constructional ant termite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified.
Raking out joints/ pointing to random rubble masonry, coursed or uncourced built in cement mortar, complete all as specified.
M&L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:4), complete all as specified.
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) exc 1.5 Sqm but n exc 4 sq. m each, complete all as specified.
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n.exc 1.5 Sqm each, complete all as specified.
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm, complete all as specified.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm Double rebated/ single rebated comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as specified. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F 30mm thick factory made wire mesh solid WPC door shutter consisting of Density 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. hinges hinges and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19x6mm size steel screws etc. Complete as per direction of manufacturer's specification & drawings.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45x 70mm (suitable for double door shutters) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as specified. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F 100mm size stainless steel butt hinges, extruded pin, anodised, complete all as specified. Make : Shalimar, Deepak or ISI marked.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section. Make : Classic, Shalimar or equivalent ISI marked
S&F 100mm long aluminium anodized barrel tower bolts of extruded section. Make : Classic, Shalimar or equivalent ISI marked
S&F 150mm extruded aluminium alloy handles fabricated type anodized. Make : Classic, Shalimar or equivalent ISI marked
S&F 100mm extruded aluminium alloy handles fabricated type anodized. Make : Classic, Shalimar or equivalent ISI marked
S&F aluminium 75mm size Hasp and staple, safety type, including bolt to hinge plate and fixed with screws, complete all as specified. Make : Classic, Shalimar or equivalent ISI marked
S&F 250mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. Make : Classic, Shalimar or equivalent ISI marked
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified. Make : Classic, Shalimar or equivalent ISI marked
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for chowkats of doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as specified.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows (sliding ) & ventilators including providing and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions
Hacking/taking out old broken glass (any thickness, size, quality or description) from aluminium frames, complete all as specified.
S&F for ordinary sheet glass 4.8mm thickness and glazing and fixed in aluminium frame work, in each panes, complete all as specified.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified.
S&F Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed in aluminium window shutters ,complete all as specified and as directed.
M&L for 18mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work or for making cabinets, partitions, doors etc and fixed on walls, complete all as specified.
M&L for 0.9mm thickness Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions, complete all as directed.
S&F 3D stainless steel slip-on soft closing concealed hinges for cabinet doors, smooth operating and fixed on doors with screws, complete all as specified. Make : Godrej,
S&F stainless steel round D type handles with chrome finish for cabinets of size 100mm and fixed with screws , complete all as specified.
Dismantling of old stainless steel cage from kitchen shelves , all as specified and directed.
S&F 1st quality Stainless steel of 304 grade cage for modular kitchen of required gauge /dia suitable for accommodating sliding kitchen cabinets design as per directed, fixed as in position , complete all as directed.
S&F pullouts, telescopic channels blumotion channels, bottom mounted channels, for Modular kitchen of required length upto 0.60m suitable for stainless steel kitchen trollies and fixed as in repairs, complete all as specified. Make : Godrej
M&L for 12mm thick plywood, grade BWP type BB fixed with screws to metal frame work and fixed as in repairs, complete all as specified & directed.
Dismantling Single layer Mangalore pattern or similar tiles in roofing all as specified and directed
Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section all as specified and directed
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified.
Dismantling timber scantlings 40sq.cm and over in section, in any position, complete all as specified.
S&F timber framed and fixed clean sawn second class hard wood in scantlings as in purlins, rafters, joints etc, complete all as specified.
M&L for 2nd class hardwood clean sawn battens ( as in roofs for fixing of Mangalore tiles) at 60cm centres and sectional area Exc 5 Sq.cm & n.exc 15 sq.cm), complete all as specified and directed
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws all as specified.
M&L for 2nd class hardwood clean sawn battens ( as in roofs for fixing of Mangalore tiles) at 30cm centres and sectional area Exc 5 Sq.cm & n.exc 15 sq.cm), complete all as specified and directed
M&L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified and directed
M&L for fixing of old Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified and directed
M&L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 all as specified and directed
M&L for Preparing wooden surfaces of any description or slate battens old/new , any size and spacing, prepared and treated all over (measured overall on one side only, spaces not deducted) with Creosote, complete all as specified.
Preparation of new wooden surfaces and apply two coats of synthetic enamel paint over a coat of pink primer, complete all as specified.
Preparation of old wooden surfaces of any description , over 10cm width or girth and apply two coats of synthetic enamel paint, complete all as specified.
Dismantling boarding, any description, fixed in any position with nails (at any height in ceiling etc), complete all as specified.
M&L for 20mm thickness 2nd class Hardwood boarding as in roofs, ceiling, partitions, cupboards etc fixed with nails in any situation planed both sides, complete all as specified.
Fixing only 20mm thickness 2nd class Hardwood boarding as in roofs, ceiling, partitions, fixed with nails in any situation planed both sides, complete all as specified.
M&L for 6mm thick Asbestos cement plain building boards, fixed to timber framework with screws and fixed as in repairs in ceiling, flat or slopping, complete all as specified.
M&L for Asbestos cement building board cover strips, 50mm x 5mm, with bevelled edges over joints including all mitres, etc., and fixed with screws and fixed as in repairs.
S&F 2mm thickness Fibre glass reinforced semi- translucent plain sheeting (colour and design as directed) fixed with coach screw and washers in roof, cladding at facia of Mangalore tiles & fixed as in repairs, complete all as specified.
Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified.
M&L for cement concrete in foundations, filling and mass concrete type B2 1:2:4 , complete all as specified.
S&F Joist, channel, angle, or tee sections, vertical posts as in shed etc fixed independently, without connecting plates, etc. confirming to Fe 410- W (Gde- E-250) quality -A, complete all as specified.
S&F rolled sections as in main & cross beams , columns, hip and jack rafters , purlins, brackets where connected to common rafters and running rails & any other places with angles cleats or other connected plates, wind ties etc confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified.
S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from concrete, brickwork etc and making good disturbed ground.
Dismantling fencing wire mesh any type, complete all as specified
S&F Joist, channel, angle, or tee sections, vertical posts as in shed etc fixed independently, without connecting plates, etc. confirming to Fe 410- W (Gde- E-250) quality -A, complete all as specified.
Supply only PVC coated ultraviolet resistant chain link fencing ( Minimum wt 2.5kg/sqm excluding PVC coat ) 75mm x 75mm of 3mm GI mesh size,1mm dia PVC quoted, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified.
S&F Mild steel bars bars 10mm dia and over, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified.
M&L for 75mm thick cement concrete type D2 1:4:8 as in sub bases, sub floors etc , complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft /loose soil, complete all as specified.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; including removing old damaged tiles complete.
M&L for coloured Chequered cement concrete tiles rubber moulded (glazed finish) 30cm x 30cm x 25mm thick with mixture of white and grey cement in equal proportion, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6, complete all as specified.
M&L preparation of new Steel surface synthetic enamel paint of two coats in any description, over 10 cm in width or girth, not otherwise described, over a coat of Red oxide, zinc chrome, specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified.
M&L Granite (of any type) work (table rubbed and polished) 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite., and nosing /rounding to edges of stone slabs one edge, all as specified and directed .
M&L for machine cut polished cuddappa stone slab 20 to 25 mm thick as in cills/jambs, cooking platform of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4, complete all as specified.
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backing) all as specified.
M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified.
M&L coloured non-skid ceramic tiles 7-8mm thick rectified glossy (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick rendering in CM (1:4), complete all as specified and directed.
M&L, Glazed ceramic tiles coloured of size 350x 250x 7 mm/ 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4 , complete all as specified.
Disconnecting existing tanks of capacity exc 500 ltr but n.exc 1000 ltr, setting aside (or lowering if required) for repairs, including cleaning & removing all scale and dirt ,etc, from tanks and from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position.
Dismantling water tanks of capacity exc 500 ltr but n.exc 1000 ltr & taking down from building or from staging, complete all as specified.
S&F Rotational moulded polyethylene water storage tanks of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified.
Taking up or down 15mm bore steel tubing and connections, complete all as specified.
Taking up or down 20mm bore steel tubing and connections, complete all as specified.
S&F 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls ( concealed) and ceilings or laid in floors, complete all as specified.
S&F 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls (concealed) and ceilings or laid in floors , complete all as specified.
S&F as in repairs 15mm bore dia fancy type chromium plated Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified. Make : Prayag/ Jaquar / MARC
S&F as in repairs 15mm bore dia chromium plated fancy type Bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified. Make : Prayag/ Jaquar / MARC
S&F as in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified.
S&F in repairs wall mixer 2 in 1 system with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs & wall flanges, chromium plated, complete all as specified. Make : Jaquar CON-CHR-273 KNUPR )/Prayag / equivalent
S&F as in repairs Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified. Make : Prayag/ Jaquar / equivalent
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F as in repairs Mirror with plastic cabinet of size 330mmx430mm single door as per approved Make:- Prayag cat No 551 /Neelkamal / Shakti
S&F in repairs aluminium anodised chromium plated tubular towel rail 20mm dia & 60cm long between flanges of Make: Prayag . complete all as specified.
S & F in repairs soap dish stainless steel as approved by GE complete all as specified and of make prayag having cat part No.BA 342 or equivalent in jaquar
S/F in repairs glass corner shelf 300 mm with ABS brackets )300x 600' with heavy wall brackets and ss railing at corners fixed with CP screws etc completed and as directed of make Prayag having cat No.BEA 46
S&F 10 ltr capacity PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient length including internal fitting (valve less syphonic) etc. complete fixed as in repairs.
S&F as in repairs 1st quality Vitreous China wash basin, white, flat back, size 550 x 400mm including brackets or fixing with bolts in wall ,including waste coupling, waste pipe, complete all as specified.
S&F as in repairs 15mm bore dia fancy type pillar tap cast copper alloy, chromium plated ,screwed down high pressure, with long shanks and flynuts, screwed for iron pipe, complete all as specified. Make : Prayag/ Jaquar / Marc
S&F 40mm bore of High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 incl fittings (bend, tee etc) fixed complete to walls, ceilings or in floors etc., complete all as specified.
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified.
S&F as in repairs health faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. Make : Prayag/ Jaquar /MARC
S&F as in repairs 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified.
Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc.,& including scaffolding, complete all as specified.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls, complete all as specified.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls, complete all as specified.
S&F 75mm PVC (SWR) bends any radius provided with access door fixed to pipe , complete all as specified.
S&F 110mm PVC (SWR) bends any radius provided with access door fixed to pipe , complete all as specified.
S&F 110mm PVC (SWR) WC connector bent type and 110mm PVC (SWR) WC connector with lip ring, complete all as specified.
Removing building materials/ excavated soil etc. outside the MD land and deposited as per municipal corporation directions/guidelines, the rate are including loading, unloading and stacking at the destination complete.
S&F as in repairs 25mm bore heavy duty 1st quality stainless steel silver & chrome finished & anti rust type curtain rods, complete all as specified.
S&F as in repairs heavy duty 1st quality stainless steel silver & chrome finished & anti rust type brackets for 25mm bore curtain rods , complete all as specified.
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, junction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular metal flush boxes suitable length and thickness for mounting, switches, sockets, fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed
All as per Srl item No -142 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed
All as per Srl item No -142 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed
All as per Srl item No. 142 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed .
All as Srl item No. 142 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed .
All as Srl item No. 142 here in before but for call bell point complete all as specified and directed .
S & F in replacement modular switch 5/6 Amps single pole one way, one module including modular cover plate with frame and metal flush box complete all as specified and directed
S & F in replacement modular switch socket combination 5 pin, type 5/6 Amps5 in 1 flush type including modular cover plate and metal flush box with frame complete all as specified and directed
S & F in replacement modular switch socket combination 6 Pin, 5/16 Amps flush type including modular cover plate with frame and metal flush box complete all as specified and directed
S & F modular switch 5/6 Amps single pole two ways complete all as specified and directed
S & F modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed
Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed
S&F modular bell push 5 Amp complete all as specified and directed
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed
S&F Buzzer AC 230 single pole-vault ding dong type complete all as specified and directed
S & F ceiling rose surface bakelite three terminals complete all as specified and directed
Taking down carefully existing serviceable LED Tube light/ bulkhead/ security light/ recess mount fitting of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed
S & F in replacement LED Tube light fitting with polycarbonate housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed .
Supply and fixing LED building security light fitting 25 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed
S&F in replacement decorative wall light,brushed nickle finish fixture with OPAL glass diffuser including 9 watt LED B22 base complete all as specified and directed
S & F in replacement LED Bedside Light (White,3000k) 3 Watt, with flexible arm suitable for reading complete all as specified and directed
S & F in replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED all as specified and directed
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified.
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed
S&F LED lamp 9W for angle holder complete all as specified and directed
S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLS stranded copper conductor drawn in and including PVC "medium quality" concealed conduit as per size required including 2 x 6Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed (Note : PVC cable and PVC conduit shall be ISI marked) Note :- Four length of 6 Sqmm cable and two length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm FRLS including cutting chasing and grouting PVC conduit pipe including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed Note :- Two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable along with PVC conduit will be measured as one running length
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed
S & F in replacement sheet metal enclosure for double door BDs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 6 ways, 415 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed complete all as specified and directed.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply 40 to 100 Amps, triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed .
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed .
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
Supply and fix electronic meters temper proof LCD display with polycarbonate cover, Three phase 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including taking out existing meter , note down meter reading and deposit it to MES yard complete all as specified and directed
Supply & fixing in replacement of meter box of size (0.9mX0.9mX0.2m) made of Polycarbonate shall have Transparent cover, should be weather/ vermin proof, anti-acid, anti corrosive, UV resistance, fire retardant, thickness 2.25 mm double door, single opening with lock arrangement suitable for fixing 01 Electric meter & TPN DB box , including fixing electric meter with four run single core PVC copper conductor unsheathed wire multistranded 4 sqmm, properly painting complete and fixing in wall with suitable cutting, cement & brick work etc all as specified and directed
Disconnecting electric connection and taking down carefully serviceable ceiling fans and Geyser and keep in safe custody. After the building repair work or as directed refixing /hanging the ceiling fan and geyser including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified
S&F Heavy duty metal body exhaust fan of 450mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in cement mortar (1 :4) white washing matching with existing colour etc complete all as specified and directed
S&F exhaust fan made of sturdy engineering plastic of 250mm sweep ,240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in cement mortar (1 :4) white washing matching with existing colour complete all as specified and directed
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conductor cable of suitable size with anti suicide fan rods complete all as specified and directed
S&F storage type water heater (Geyser) electrical operated 230/240 Volts 50 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, fusible plug,top plug 15Amp ,heating element upto 3.5KW rate pressure 8 bar etc. required for proper functionality & including electric/earth connections and carrying out grounding & complete installations with mounting bolts,nuts including testing after installation complete all as specified and directed
Supply and fix PVC connection High Density Pipe 15mm sizes with PTMT nuts of lengths 600mm suitable for Cold and Hot water complete all as specified and directed
Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection all as specified and directed
S & F Rigid non-metallic concealed PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Dismantling and Taking down L.T. under ground armoured PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during exaction of trenches and relaying after cable laying in trenches all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed .
Returning filling in including spreading levelling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable all as specified. Note :- Punning thickness only measured.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed.
M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil complete all as specified and directed
Supply and lay jointing and testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed
M & L Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level earth lead 4 mm dia along with GI pipe 20mm dia from plate to pannel board by means of bolts , nuts, check nuts and washers of GI all as shown electrical plate No -3including alternate layer of charcoal dust and salt around the electrode and excavation , earth work, watering arrangement , funnel and wire mesh , 20mm GI pipe used for watering with iron funnel etc. all as specified and directed
M & L for GI water tubing,light grade,50 mm,1.2 m long duly threaded on one side in and including fixing of GI socket and including FI clamp of 50 X 6 mm bend to shape for fixing of GI pipe post and fixed to wall (GI pipe 1.2 m will be in single length and no joint will be allowed) complete all as specified and directed
M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floorcomplete all as specified and directed
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down.
S & F Gun-metal, globe or gate valves, 25 mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
KRISHNA ENGINEERS (BID ID -3420012)
Vishal Builders (BID ID -3420567)
CROSSLINE ENGINEERS AND CONTRACTORS (BID ID -3417579)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid