| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹7.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹7.4 Cr+₹3.8 L (0.51%)Rejected-Finance | ₹7.4 Cr+₹3.8 L (0.51%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹8.5 Cr+₹1.1 Cr (15.1%)Rejected-Finance | ₹8.5 Cr+₹1.1 Cr (15.1%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹6.9 Cr
EMD Value
₹6.7 L
Closing Date
7 Sept 2023, 6:00 pmClosed
Chief Engineer
HQ CE Udhampur Zone, PIN-900386, C/O 56 APO
ADDITION/ALTERATION AND REPAIRS WITH ALLIED WORKS FOR OFFRs, JCOs AND ORs MARRIED ACCN (FINAL PHASE) UNDER GE (N) UDHAMPUR
2023_MES_600439_1
87921-A/E8
Open Tender
Civil Works
Item Rate
547 days
Udhampur
As per NIT and tender documents
7 documents required · 7 mandatory
₹3,000
GE (N) Udhampur
₹6.7 L
31 Oct 2023
2 Jun 2023
14 Sept 2023
2 Jun 2023
7 Sept 2023
26 Aug 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site complete all as specified and directed.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings complete all as specified and directed.
Stainless steel butt hinges 100 mm with steel screws, complete all as specified and directed.
Pressed steel frames of size 125mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate, complete all as specified and directed.
Pressed steel frames of size 105mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate, complete all as specified and directed.
Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing as in cup board (40 x40 x 5mm) complete conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Flush door shutters 35mm thick, solid core construction, with partical board core and plywood face panels, commercial type on both sides,complete all as specified and directed.
Factory made solid PVC wire gauged shutter 30mm thick width & including Stainless steel wire cloth shall be of 0.36 mm nominal dia SS wire with average width of aperture as 1.40 mm for mosquito proofing. i.e panel will be of wire gauge in lieu of sheet panel. The wire gauge shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tube. The wire gauge shall be stretched to tighten firmly ,complete all as specified and directed. Note:- Stainless steelwire shall be measured and paid seperatly.
18/19 mm thick PVC board one side decorated laminated of approved colour and other balancing side white in colour, cut to size as required and fixed in position for cabinets, etc ,complete all as specified and directed. . Make- Rajshree or Equivalent.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm dia and fixed with Stainless steel wire staples complete all as specified and directed.
Helical Double action spring hinges 150mm, mild steel with steel wire spring, stove enamelled, black, complete all as specified and directed.
Butt hinges 75 mm, medium weight, cold rolled mild steel, complete all as specified and directed.
300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed , complete all as specified and directed.
250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed , complete all as specified and directed.
Aluminium anodized 200mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
Aluminium handles cast type anodized of size 100 mm complete all as specified and directed.
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.
Hasp and staple Alumnium anodised lncluding bolt to hinges plate 100mm and fixed with screws, complete all as specified and directed.
Aluminium handles cast type anodized of size 125 mm complete all as specified and directed.
Aluminium anodized 125mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
Continuous (piano) hinges 30mm width of flap, mild steel, bright finish or electro galvanised , complete all as specified and directed.
Floor door stopper of 150mm long of alluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor complete all as specified and directed.
Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
Powder coated (any colour)( thickness powder coating not less than 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 nos.) suitable handle (1 no.)tower bolt 125mm (02 nos), complete all as specified and directed.
Aluminium decorative grill of 5 to 6mm dia size of mesh not exceeding 7.5 cm in either direction as approved by GE ,complete all as specified and directed.
Mild steel framed work such as grills,gratings, manhole cover frames etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.
Sheet glass 4mm thick ordinary quality and glazing in square not exceeding 0.5 Sqm in each pane, fixed to steel or metal frames complete all as specified and directed.
Sheet glass 4mm thick figured glass and glazing in square not exceeding 0.5 Sqm in each pane, fixed to steel or metal frames complete all as specified and directed.
Cutting helds in brick walls built in cement mortar for inserting hold fasts (Depth of embedded portion of hold fasts or lungs measured from the face of the jamb into the walls (exc. half brick but not exc. one brick) and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-I using 20mm graded cushed stone aggregate complete all as specified and directed.
Preparation of New or previously untreated surfaces of steel of any description over 10 cm in width or girth not other wise specified and appling two coats of synthetic enamel paint over a coat of red oxide primer,complete all as specified and directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old surface of any description and girth, not otherwise described, and treated with tar or coal tar black paint ,complete all as specified and directed.
Providing and laying water proofing treatment to sunken portion of WCs including primng the sunken surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) 3mm thick and weight not less than 3.00 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm all as specified and filling with cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregates) covering with 25mm thick screed bed cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregates) for sunken portion ,complete all as specified and directed. Note :- Before laying of concrete contractor shall carried out at least 8hrs ponding test for any leakage in each sunken and joints of trap/WC/soil shall be properly sealed with sealing compound of roofex/forre/FOSROC and provn of P/ S Trap, nahani/trap/floor trap with lonf arm with spout 40mm.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided,complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness,complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in floor finish, surface finished even and smooth without using extra cement complete all as specified and directed.
Vitrified ceramic tiles 8 to10mm thick (square/rectangular) (coloured), area of each tile exceeding 0.36 sqm and not exceeding 1 sqm as directed by EIC, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement mortar 1:4 for laying floor rough ,complete all as specified and directed.
Vitrified ceramic tiles 8 to10mm thick (square/rectangular) (coloured), area of each tile exceeding 0.36 sqm and not exceeding 1 sqm as directed by EIC, as in vertical surface such as skirting/dado as set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick backing in cement mortar 1:3 on brickwork or concrete surface of finished rough to receive tiles ,complete all as specified and directed.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 for laying floor finished surfaces , complete all as specified and directed layer.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor jointed in neat cement slurry and pointed with coloured cement to match and fixing of tile over and including 10 mm thick screed bed or bedding layer with cement mortar 1:4 for laying floor finished including roughening of existing surfaces by picking and removing debris/unwanted material and wash down with water, complete all as specified and directed .
Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mm x 300 mm x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Dismantling stone slabs and tiles of any description or thickness in floors, apron etc laid bedded and pointed in any mortar,complete all as specified and directed
20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engineer-in-Charge.
Machine cut kota stone single piece slab flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 20mm screed layer in cement mortar 1:4 including cutting, rubbing, grinding,protruding chamfered/rounded edges in threads table rubbed and mirror polished rubbing and polishing , complete all as specified.
Kota stone slab flooring single piece slab 18 to 20 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as in in skirting, dados, risers to steps etc, laid over and including 10mm thick rendering in cement mortar 1:3 including cutting, rubbing, grinding,protruding chamfered/rounded edges in threads table rubbed and mirror polished rubbing and polishing , complete all as specified.
PVC connections 15 mm size with PTMT nuts of length 600mm fixed in repair complete all as specified and directed.
Stop valves/ angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure , screwed both ends for 15mm bore iron pipe or for unions and fixed in repair complete, all as specified. Type of valve approved by the GE.
Shower rose brass chrominium plated 125mm with arm and without swivel joints to steel pipe size fixed in repair. complete all as specified and directed.
Stop valves/ angle valve/ concealed valve, cast copper alloy with long shank and cup, chromium plated, fancy type, screwed down, high pressure , screwed both ends for 15mm bore iron pipe or for unions fixed in repair and complete, all as specified.
Cast copper alloy CP stop cock /angle Valve, fancy type, screwed both ends for iron pipe 15mm dia/ bore of pipe but with long shank and cup ( concealed type) fixed in repair.complete all as specified and directed.
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws fixed in repair, complete all as specified
Stainless steel soap dish size 160mmx160mmx90mm, fixed to plugs with chromium plated brass screws complete all as specified.
Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore fixed in repair ,complete all as specified and directed.
Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe for Wash Hand Basin with wall flange ,complete all as specified and directed.
Wall mixture non telephonic shower arrangement with connecting legs & wall flange ,complete all as specified and directed.
Sink mixture with regular swinging spout wall mounted with connecting legs & wall flanges,complete all as specified and directed.
Stainless steel plate racks of size 750mm x 900 x 250mm and thickness of SS strip of 1mm fixed on wall etc ,complete all as specified and directed.
Stainless steel plate racks of size 600mm x 750 x 250mm and thickness of SS strip of 1mm fixed on wall etc ,complete all as specified and directed.
Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including 32mm waste fittings brass chromium plated etc fixed in repair,complete all as specified and directed.
Supply and fix in repair SS sinks double bowl kitchen Sink,1 mm thick with plug, washer and waste, including 02 nos of waste coupling, double bowl ,connector & 1 Nos waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, size 45 inch x 20 inch x 9 inch and bowl size 510 mm x 405 mm x 203 mm completed all as specified
Mirror cabinet PTMT of 450mm x 600 mm with magnetic looking arrangements fixed with and including chromium plated brass screws and PVC rawl plugs, complete all as specified and directed.
25mm dia Stainless Steel curtain rod fixed in repair with brackets and knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories . Note : The cost of brackets and knobs is deemed to be including in the quoted rate. Nothing extra shall be paid on this account.
Taking down steel tubing and connection of15mm bore of pipe ,complete all as specified and directed.
Taking down steel tubing and connection of 20mm bore of pipe ,complete all as specified and directed.
Taking down steel tubing and connection of 25mm bore of pipe ,complete all as specified and directed.
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
G I tubing medium grade of 25 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
Refixing only old seriviceable 15mm steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Refixing only old seriviceable 20 mm steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Refixing only old seriviceable 25mm steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
G I tubing medium grade of 32 mm bore for spout laid in sunken portion/floor,complete all as specified and directed.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories),complete all as specified and directed.
Cast iron floor trap,75 mm dia, with SS grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 using 20mm graded crushed stone aggregate,complete all as specified and directed.
Dismantling of cast iron or RCC drain pipes including all fittings and accessories, 100 mm dia and in any position,complete all as specified and directed.
Dismantling of cast iron or RCC drain pipes including all fittings and accessories, 75 mm dia and in any position,complete all as specified and directed.
Cast iron spun pipes, 100 mm double socketed in any length with cement joints, fixed to walls,complete all as specified and directed.
Cast iron spun pipes, 75 mm double socketed in any length with cement joints, fixed to walls,complete all as specified and directed.
Refixing only old seriviceable cast iron spun pipes, 100 mm double socketed in any length with cement joints, fixed to walls,complete all as specified and directed.
Refixing only old seriviceable cast iron spun pipes, 75 mm double socketed in any length with cement joints, fixed to walls,complete all as specified and directed.
Bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore complete all as specified and directed.
Bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore ,complete all as specified and directed.
Cast iron branch pieces single, (single T) equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 100mm dia ,complete all as specified and directed.
Cast iron branch pieces double, (double T) equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 100mm dia ,complete all as specified and directed.
Cast iron branch pieces single, (single T) equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 75mm dia ,complete all as specified and directed.
Cast iron branch pieces double, (double T) equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 75mm dia ,complete all as specified and directed.
100 mm dia cast iron vent cowl,complete all as specified and directed.
75 mm dia cast iron vent cowl,complete all as specified and directed.
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed bore dia of pipe 20 mm fixed in repair ,complete all as specified and directed.
Vitreous China squatting pan of Orissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl cement concrete bedding and connection to antisyphonage pipe etc including making good to floor. , fixed in repair, complete all as specified and directed.
Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, chromium plated jet including PVC connection, fixed in repair, complete all as specified and directed.
Plastic water closet seat, white colour closet pattern with flat bottom and cover and including mild steel chromium plated or aluminum hinges device fixed in repair, complete all as specified and directed.
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long fixed in repair, complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia , 32mm dia waste fittings, fixed in repair, complete all as specified and directed.
Taking down old PCC tiles form roof and removing bedding at any position , complete all as specified and directed.
Rendering 15 mm thick cement plaster in cement mortar 1:3 on roof surfaces finished even and smooth without using extra cement, including mixing of water proofing compound as per manufacture instruction for Accessable roof/Non Accessable roof , complete all as specified and directed. Note:- Water Proofing Compund shall be measured and paid seperatly as supply only.
Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) 3mm thick and weight not less than 3 Kg/Sqm reinforced with non woven spun bonded polyester reinforcement < -2 C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly. The minimum side lap and end lap shall be kept at 75mm and 100mm respectively with center layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/ Sqm blinded with fine sand in dry condition @ 0.50 Kg/ Sqm including cutting grooves (50mm x 50mm) in parapet and inserting edges of membrane and mending grooves damage by cement mortar (1:4) and shall be finished in all respect as per directed by Engr-in-Charge. Note:- Laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
Chequered cement concrete coloured tiles, homogenious texture glossy finished , chemically coated machine pressed 25 cm x 25cm x 22mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 15 mm thick cement screed in cement mortar 1:4 over ,complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Taking down existing roof treatment of any description and any type ,complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 Kg of cement per sqm ,complete all as specified and directed..
Supply only water proofing compound ,complete all as specified and directed.
Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) 3mm thick and weight not less than 3 Kg/Sqm reinforced with non woven spun bonded polyester reinforcement < -2 C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly. The minimum side lap and end lap shall be kept at 75mm and 100mm respectively with center layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/ Sqm blinded with fine sand in dry condition @ 0.50 Kg/ Sqm with two coats of aluminium paint over a coat of primer including cutting grooves (50mm x 50mm) in parapet and inserting edges of membrane and mending grooves damage by cement mortar (1:4) and shall be finished in all respect as per directed by Engr-in-Charge. Note:- Laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
Plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in , benching as directed including necessary form work and finishing ,using water proofing compound as per manufactures instructions along side wall adjoing to kerb in concave surfaces ,complete all as specified and directed. Note:- Water Proofing Compund shall be measured and paid seperatly as supply only.
Taking down cement plaster including raking out joints hacking for key scrubbing down with water etc ,complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces and finishing the surface even & smooth without using extra cement,complete all as specified and directed.
Rendering 15mm thick plaster in CM 1:4 mixed with WPC as per manufactures instructions in two layer (10mm+5mm) in patches in cement mortar in 1:4 on smooth face of brick work or concrete surfaces finishd even and smooth without using extra cement,complete all as specified and directed. Note:- Water Proofing Compund shall be measured and paid seperatly as supply only.
Rendering 5mm thick in cement mortar in 1:3 on ceiling finishing even and smooth without using extra cement ,complete all as specified and directed.
Providing reinforced cement concrete type A-1 (1:1:5:3) (using 20mm graded crushed stone aggregate) as in chullah hoods, chajjas and similar articles, including use and waste of necessary form work complete all as specified and directed.
Hard core of broken bricks n exe 63 mm, deposited, spread and levelled in layers n exe 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on to any radius in half brick, built in cement mortar 1:4 complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
PCC 1:3:6 C-2 (using 40mm graded crushed stone aggregate) as in plinth protection ( 75mm thick ) finished even and fair including making joints 10mm wide and 30mm deep at spacing n more than 2.5m and at corners at mandatory and filled with sealing compound grade B complete all as specified and directed.
Demolition of RCC of any description such as Kitchen chimney, chajja, shelves, OHT Tanks. etc and in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition) ,complete all as specified and directed.
Reinforced cement concrete (M-25 design mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ,complete all as specified and directed.
Providing TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending and binding with & including MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
All as per srl item no 121 above here-in-before but 6 to 8mm dia , complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete flat, complete all as specified & directed.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete, complete all as specified & directed.
Dismantling water tank of capacity exc 250 but not exc 500 and remove to Store complete all as specified and directed.
Dismantling water tank of capacity exc 500 but not exc 1000 and remove to Store complete all as specified and directed.
Rotational moulded polyethylene water storage tank 500 Ltrs capacity three layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete and making connections with existing water supply line ,complete all as specified and directed.
Rotational moulded polyethylene water storage tank 1000 Ltrs capacity three layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete and making connections with existing water supply line ,complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over and including 1 to 2mm thick wall care putty complete all as specified and directed.
Preparing new plastered surfaces and applying 3mm wall care putty in wall surface and smoothening the surface with sand papers / Mechanised sanding etc and applying two coat of Oil Bound distemper of approved tint over a coat of alkali resistant primer, complete all as specified and directed.
Preparation of plastered or unplastered surface of ceiling and applying three coats of white wash,complete all as specified and directed.
Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and including 1 to 2mm thick wall care putty over plastered surface to prepare the surface even and smooth,complete all as specified and directed.
Applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces, complete all as specified and directed.
Eye door viewer (magic eye) fixed in position for door shutters in repair , complete all as specified and directed.
Door sill rubber sheet 50mm wide and of thickness not less than 3mm fixed with stainless steel screws at the bottom of the door shutters, complete all as specified and directed.
Stainless steel fancy type peg set of four and fixed in position with steel screws , complete all as specified and directed.
Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging holes etc in apron , complete all as specified and directed.
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2(1 cement : 2 coarse sand) to match the existing floors , complete all as specified and directed.
Anti termite treatment of voids in masonry using chemical emulsion one litre per hole at 300 mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors , complete all as specified and directed.
Precast cement concrete type B0 1:2:4 (12.5 mm graded crushed stone aggregate) louvres and jallies 25mm thick (measured solid) including all moulding but excluding frames set in cement mortar 1:4, complete all as specified and directed.
Precast cement concrete type B1 1:2:4 (20mm graded crushed stone aggregate) as in bressumers, steps quoin blocks (for use with masonry) and set in cement mortar 1:4, complete all as specified and directed.
Factory made solid PVC moulded Particle board core exterior grade door/cupboard shutters 28 to 30 mm thick (stiles) designed with 2 mm thick moulded prelam PVC sheet on the front face & 2 mm plain colour PVC sheet on back face , complete all as specified and directed.
Grinding and polishing existing kota stone flooring , complete all as specified and directed.
Stainless steel toilet paper holder of size 180x90x70 mm, complete all as specified and directed.
Providing and maintaining Barricading on the site 2.5 m high by using MS Pipes or angle iron frame work of verticals at 3.00 m c/c and horizontals at 0.90 m c/c, Galvalume sheets, Struts, MS Clamps, etc. The verticals shall be embedded/ fixed to concrete pedestals below ground. The rate to include fabricating, cutting and fixing in position MS frame work, painting the same with two coats of approved anti rust paint, etc complete,complete all as specified and directed. Note:-Contractor to get structural design approved by the Engineer. Contractor shall remove and take away the barricading at his own cost on completion of the works
Chipping /removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc , complete all as specified and directed.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying Polymer mortar , complete all as specified and directed. Make :- SIKA- SIKA Rust off 100 or SIKA S.B.R or Latex Power FOSROCK - Reebaklens RR or Nitobond AR
Application of Corrosion Inhibitor: Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor (Surface applied) which works on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sq.mt./Coat or as per manufacturer’s specification and prior to application of first coat of anti corrosive coating to reinforcemen , complete all as specified and directed. t. Make :- SIKA - Feroguard 903,FOSROCK - Auramix BCI
Providing and applying Polymer modified cement mortar of average thickness 15-20mm using Polymer in one or more layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster , complete all as specified and directed. . Make :- SIKA - Sika 122 WL,FOSROCK - Renderoc S2
Providing and applying Polymer modified cement mortar of average thickness 30-40mm using Polymer in two layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster , complete all as specified and directed. . Make :- SIKA - Sika 122 HS FOSROCK - Renderoc HS xtra
Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars. FOSROCK - HILTI, Ficher
Bond Coat: Providing & applying One coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882-87 to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete surface and new concrete surface. Make :- SIKA - SIKADUR 32LP, HIBOND
Providing Micro concrete jacketing to walls/ columns or beams of thickness upto 75 mm using polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture, for high early strength of 40 N/mm sq.cm of approved brand. The dry product is to be mixed with 12.5% water by weight, along with washed and poured into rigid form work moulds & tamped properly, & cured for 3 days. Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material , complete all as specified and directed. . Make :- SIKA - Sika Rep microconcrete-4 FOSROCK - Rendero CRG
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. Make :- SIKA - SIKALalex or SRB FOSROCK- Nitobond EP
Anti corrosive coating to exposed reinforcemennt providing and applying two coats of anti corrosive protective coating(CBRI/CSIR Tecnology) for reinforcement bars by brush. Sprinkle so as to get rough surface complete. Note:- For items 147 to 155. (i) Work shall be executed only through authorised applicators of the same Manufacturer. (ii) under mentioned Non Destructive tests should be conducted at site. (a) Rebound hammer test. (b) Ultra Sonic Pulse Velocity test. (c) Half cell potensial test. (d) Corbonation test. (iii) Site for application is at various locations and height varies up to 15.0M (iv) All Scaffolding work and safety measures such as provision of props and supports shall be of steel and extent of provision shall be entire to satisfaction of GE. (v) Mode of measurement for items: For the purpose of the measurement of these items the surface area of the patch of the concrete considered of repair shall be taken. (vi) Testing of cube strength of polymer modified cementious mortar shall be independently carried out as per manufacturers instructions and record shall be maintained. (vii) After obtaining approval of the make of the products the contractor shall give a letter from the same manufacturer regarding the details of the agency and the name of person to be deployed for carrying out repair & Supervision of the work. (viii) The T&P shall be strictly as per manufacturer’s instructions. (ix) Necessary Jacks shall be erected to support various floors before exposing columns/ beams for repair & it shall also be ensured that no damage is made to existing structure during the repair process & all safety norms shall be followed.
Provision of modular kitchen cabinet made of 12mm thick both side MDF partition, SS handles, SS telescopic channels, SS brackets, SS hinges, SS basket and necessary fittings & nuts ,Size of cabinet (1.8mx0.6mx0.7m) complete all as specified and all as directed by Engr in charge Note: Each kitchen cabinet consisting six no basket (3 Nos of size 200x450x530)mm weighing 5.12 kg other (3 Nos size 150x450x530)mm weighing 3.46 kg having telescope channel of length 450 mm ( 12 nos) with SS Euro Slip hinge (12 nos with SS handle 12 Nos duly approved by GE.
110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls any height including necessary fittings i.e Bend, Tee , Y,stack clamps made out of 50mm x 5mm flat iron & 15 mm dia round iron stays,etc complete all as specified and directed.
75 mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls including necessary fittings i.e Bend, Tee , Y,stack clamps made out of 50mm x 5mm flat iron & 15 mm dia round iron stays,etc complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in any type of soil,complete all as specified and directed.
Removing excavated surplus material (soils) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point. complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50 mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator over and including 75mm thick PCC 1:5:10 (Nominal Mix) type E-2, using 40mm graded crushed stone aggregate ,complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required ,complete all as specified and directed.
PVC waste pipe for wash hand basin,kitchen sink with SS grating & union for discharge pipe ,complete all as specified and directed.
Health faucet, brass, chromium plated, with 1m long, 8mm dia, chrome finish flexible pipe with wall hook complete all as specified and directed. Make: Jaquar Cat Part No. ALD-573, Cera-F 8030103
Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection; for EWC fixed complete all as specified and directed.
Hand shower 90mm round shape (telephonic shower), chromium plated, with 1500mm long, 15mm bore chrome finish flexible pipe with hook, fixed in repair complete all as specified and directed. Make: Jaquar-code HSH-1727,SHA-571, Cera-F 7030105 for hand shower & F-8070401 for flexible tube.
35mm thick factory made single piece wire gauge doors shutter solid PVC UV printer door wood free consisting of 5mm thick solid PVC sheet on both side multi colour UV printed) using steel/Aluninium XPM/wire mesh & consisting frame made out of MS tubes of 19 gauge thickness and size of 19mmx19mm for stiles and 19mmx19mm for the top, bottom & lock rails with PVC beading in all around MS frame shall be have a coat of metal primers MS frame shall be covered with heat moulded (rigid) 20/22mm PVC solid sheet at style , top rail & bottom rail (rigid) MS frame welding sealed to the style and with suitable PVC sheet beading & joint together with solvent complete all as specified and diredted by Engineer-in-Charge. Make: The shutter is to be fixed with 50mm six self drilling star screws full threaded.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white/ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putti or distemper / colour wash with same existing colour surfaces.One light /Fan/Bell/exhaust fan point controlled by one switch 6/5 Amp one way single pole. all as specified and directed by Engineer-in-Charge
All as per srl item No-169 above here-in-before but One 3/5 pin socket outlet, 5 Amp independent , complete all as specified and directed.
All as per srl item No-169 above here-in-before but One socket outlet 3 Pin, 5 Amps, SP on same board, complete all as specified and directed.
All as per srl item No-169 above here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per srl item No-169 above here-in-before but controlled by two way switch , complete all as specified and directed.
Modular switch single pole one way 10Amps 1 module complete all as specified and directed
Modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Switch piano flush type, single pole, two way, 5 Amps, complete all as specified and directed.
Modular socket outlet 6 amps two and three pin combined, 2 module complete all as specified and directed
Modular Bell push 6 amp 01 module ,complete all as specified and directed.
Modular socket 6 /16 Amps 2/3 pin flush type ,complete all as specified and directed.
Ceiling rose, 65 mm to 50 mm, two to three terminals, three face PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Modular electronic fan regulator, step type, two module 120 watt 230 volt and making all necessary connections ,complete all as specified and directed.
Modular metal flush box 6 module ,complete all as specified and directed.
Modular metal flush box 6/8 module ,complete all as specified and directed.
Modular metal flush box 3 module ,complete all as specified and directed.
Modular metal flush box 2 module ,complete all as specified and directed.
Modular metal flush box 1 module ,complete all as specified and directed.
Modular white cover plate with frame 6 module ,complete all as specified and directed.
Modular white cover plate with frame 8 module ,complete all as specified and directed.
Modular white cover plate with frame 3 module ,complete all as specified and directed.
Modular white cover plate with frame 2 module ,complete all as specified and directed.
Modular white cover plate with frame 1 module ,complete all as specified and directed.
Electric bell ding dong 230 volt AC,single pole, complete all as specified and directed.
Taking down existing serviceable tube light fittings any type any wattage and keep in safe custody for refixing the same after rewiring ,complete all as specified and directed.
Refixing only old serviceable Slim linear LED lighting fixture 4/5W watt LED batten, with full base of extruded poly carbonate isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge.
Refixing only old serviceable decorative ultra slim linear Aluminium Extruded LED lighting fixture 10/12 Watt LED of input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting complete all as per directed by Engr-in-charge.
Refixing only old serviceable Slim linear LED lighting fixture 20 Watt LED batten, P.F greater than 0.9, input voltage range from 90 Volts to 280Volts with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting complete all as specified and as directed by Engineer-in-Charge.
LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by Engineer-in-Charge.
City 3 decorative wall light fixture made up of polycarbonate suitable for 15 watt LED (B-22 base) ,complete with testing all as specified and directed by Engineer-in-Charge.
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the direction of Engr-in-Charge.
LED lighting fixture 10/12 watt LED batten, with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the direction of Engr-in-Charge.
LED lighting fixture 05 watt LED batten, with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings ,complete all as per the direction of Engr-in-Charge.
Security light fitting 35 watt, new generation energy saving & environmental friendly long life versatile pressure die cost aluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver, including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light GI tubing bracket of 25 mm dia, light grade 1.2 mtr long having 120 degree angle and fixed on wall including clamps, nut, bolts and washer for fixing of building security (street) light ,complete all as per the direction of Engr-in-Charge.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (2 run of cable)of size 6 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sqmm one run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections, complete all as specified and directed.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (2 run of cable)of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4.0 sqmm one run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections complete all as specified and directed.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (4 run of cable)of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 32mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm one run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, Jall: pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) , all excavation and earth work & connecting the earthing to an earthing test point / main switch board and testing on completion,complete all as specified and directed.
4mm dia GI wire as earth continuty conductor or main earth strip fix to wall on batten or recess or chess or burrid in ground or any other indicated situation for loop earthing etc ,complete all as specified and directed.
Exhaust fans steel body,AC single phase 230 volts of size 250 mm sweep with blades , complete with aluminium louvers frame and shutters fixed on walls and grouting bolts and nuts of suitable size in PCC 1:2:4 type B-1 blocks of size 150x150x150mm including provision of cable, 3 core, flexible copper conductor 23/.0076 from ceiling rose to fan and testing, Complete all as specified and directed
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with provision of cable 3 core flexible copper conductor 23/0.0076 from ceiling rose to ceiling fan including fixing and connecting up of fan regulator complete all as specified.
Sheet metal enclosures (Double door) for DB's when MCBs to be used, Triple pole and neutral 4 way , 415 Volts, 50 Hz complete all as specified and directed.
Sheet metal enclosures (Double door) for DB's when MCBs to be used, Single pole and neutral 12 way , 240 Volts, 50 Hz complete all as specified and directed.
Sheet metal enclosures (Double door) for DB's when MCBs to be used, Single pole and neutral 4 way , 240 Volts, 50 Hz complete all as specified and directed.
TPN 100 Amp ,415V 10KA 'B' curve miniature circuit breaker (MCB) complete with connection testing and commissioning , complete all as specified and directed.
MCB SP,C series, 06 to 32 Amp, 240 Volts,50 Hz, 10 KA , complete all as specified and directed.
MCB SPN,C series 40 to 63 Amp, 240 Volts,50 Hz, 10 KA, complete all as specified and directed.
MCCB 160A, 3 pole 36KA , 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed.
MCCB 250A,3 pole 36KA ,415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed.
Taking down ceiling fan/exhaust fan, shifting to store complete and rehanging the same after overhauling and painting with white synthetic enamel paint (two coat) with the help of spray gun and connecting with three core flexible copper conductor cable 0.75 sq mm, complete all as directed by Engr-in-Charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity , complete all as directed by Engr-in-Charge.
Taking down serviceable/unserviceable electric meter including meter box from existing position carefully for refixing including making good to disturbed surfaces, complete all as directed by Engr-in-Charge. (Note : Disturbed surfaces should making good by Plastering/distembering/colour washing/white washing to match with existing surfaces)
Refixing only old seriviceable electric meter obtained from srl item No 221 here-in-above with meter box by grouting to the wall and fix firmely all as specified and directed by engineer incharge.
Taking down the existing geyser of any capacity carefully and shifting to the store and re-fixing the same after completion of B/R works directed by the Engineer-in-Charge
Supply, laying ,jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 25 Sqmm, 4core complete all as specified and directed.
Supply, laying ,jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 16 Sqmm, 4core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in deep in any type of soil for laying of under ground cable ,electric pole and getting out complete, all as specified and directed by Engr-in-charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick (soil) all as specified and directed by Engr-in-charge.
Removing excavated material (soil) from site to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point all as specified and directed by Engr-in-charge.
Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable and pulling down to 18cm for measurement complete all as specified and as directed.
Well burnt bricks, sub class B, old size, laying in trenches, perpendicular to axis of the cable complete all as specified and directed.
Steel water tubing light grade of dia 40mm galvanized with all fittings and fixed complete to walls or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified.
Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Amount of Rs. 15,26,272.00 during AOC. Note: Tenderers shall not quote for this schedule.
M/S Inderjit Sharma and Co.
JINDAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .