Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.2 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹42.9 L+₹7.5 L (21.2%)Rejected-Finance | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹45.6 L+₹10.3 L (29.1%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | - | Rejected-Technical Not enlisted in required category |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA Gwalior
GE AF TA Gwalior 474020
ADDN/ALTERATION TO OPS ROOM OF 1SQN, 7SQN AND 9SQN AT AF STN GWALIOR
2023_MES_620202_1
8900/1508/GWL/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN Gwalior
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF TA Gwalior
₹87,000
Yes
18 Dec 2023
23 Sept 2023
26 Oct 2023
23 Sept 2023
23 Oct 2023
10 Oct 2023
Amount
Demoliton of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Dismantling floor, hearth or wall tiling or stone slab including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Dismantling Wall and ceiling boards complete or in parts (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets and making good of edges of existing wall boards by Cover fillet or wall panelling tape , or aluminium partitions any thickness, including cover fillets all as specified and directed.
M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed.
M&L for 15mm thick rendering other than fare face of brick/stone masonry walls in CM 1:6 finished even and smooth without using extra cement all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement all as specified and directed.
M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions and applying one coat of distemper oil emulsion white or tinted as approved complete all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion over a coat of primer over birla/JK/Asian wall care putty as approved all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emultion white or tinted over a coat of primer and wall putty as approved complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-1 (20mm graded stone aggt) as in flooring complete all as specified and directed.
M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 15mm thick screed bed in CM 1:4. complete
M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,, in skirting/dado or vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 10mm thick Rendering in CM 1:4. complete all as specified
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware & glass etc complete all as specified & directed.
S&F UPVC luxury casement sound proof fixed type windows and frame with double glass glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (6T+12+6T) internal plain and external tinted with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc with lock and key complete weight not less than 32 Kg/Sqm all as directed. Make : FENESTA/KOMMERLING/PROMINANCE
S&F UPVC sound proof door and frame with double tinted glass glazing 65mm/C65PS3/ Z-SASH, DG INS, TGH (6T+12+6T) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 32 Kg/Sqm all as directed. Make : FENESTA/KOMMERLING/PROMINANCE
S&F in repairs Brass, 4 Levers Mortice lock size 100 mm, vertical type, fixed to doors all as specified and directed.
S&F for powder coated aluminium deco grills size 4mmx4mm, 8mm thick and aperture not exeeding 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete including taking down existing grill complete all as specified and as directed.
Fixing only Anodised aluminium Partitions Including Doors, Frames, glass , boards etc all necessary fittings to fix the partitions in position where shown complete all as specified
S&F Anodised aluminium frame for doors,windows, ventilators & partitions with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F Anodised aluminium door shutters, aluminium vertical section, Top rail and middle rail having section 44.5x85x3mm & bottom rail having section 44.5x114.0x3mm including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified.
S&F 5 mm thick tinted glass , ordinary quality and glazing to Aluminium window and doors and partitions complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F 5-6 mm thick ACP board interior grade, fixed to Aluminum Doors complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3m ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soft/loose soil.
M & L for plain Cement concrete type D- 2,1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for R.C.C. grade M-25 (design mix) (using 20mm graded stone aggregate) in Foundations, including rafts, footings, foundation and mass concrete complete all as specified.
M&L for R.C.C. grade M-25 (design mix) (using 20mm graded stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for R.C.C. grade M-25 (design mix) (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L for R.C.C. grade M-25 (design mix) (using 20mm graded stone aggregate) as in lintel Beams & Roof Beams and in chajjas complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical at flat surface complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work including chajja not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 5mm thick rendering fare face of brick/stone masonry walls in CM 1:3 finished even and smooth without using extra cement as in ceiling all as specified and directed.
M&L for Preparation of newly plaster surface of ceilng and applying two coats of distemper oil emulsion as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for PCC (1:3:6) type C-1 (20mm graded stone aggt) as in Plinth protection, surface finished even & fair using extra cement.
M&L for 75 mm thick PCC (1:4:8) type D-2 (40mm graded stone agg) as in sub base of flooring complete all as specified and directed.
Earth filling under floor obtained from excavation Spreading and levelling in layers n exc. 25cm thick,well ramming including watering as required complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material exc 1.5Km but n exc.n exc. 5Km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for Pre Constructional Antitermite Treatment to the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Pre Constructional Antitermite Treatment to the backfill in contact with floor at the rate of 7.5 litres of emulsion per square metre (Area of the sub structure in contact with backfill to be measured).
M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick plaster in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed.
M&L 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching,kerbs and levelling course etc over roof surface including removal of old unserviceable roof treatment complete all as specified and as directed
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Applying hot blown grade bituminen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by aithorized applicators. Make: IWL India Ltd/STP/Torchtar/ Pidilite Industics Ltd etc (e) Applying a coat of Alluminium Paint over APP Membrane.
S&F 16mm thickness acoustic mineral fibre micro perforated finish (Reveal type) ceiling board of 600x600mm size fixed over and including pre powder coated GI frame with suspension system (Grid) comprising of T section 25mmx32.5mmx1.6mm size as main runners and wall angle to placed along the wall at desired level of the False ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided at desired distance and making good the dismantling portion complete all as directed.(Make:- GypRoc (Clotex Serino) Saint Gobain, Armstrong(RH99 Dune) or Equivalent as approved by GE)
S&F "ACOUSTIC PERFORATED PRELAM PVC WALL PANELLING consisting of PVC Perforated panels having wall thickness of 5mm ( ±0.25 ) PVC sheet of Density 600 Kg /Cbm , and the desired thickness of Glasswool/ Rockwool pasted with perforated sheet with suitable adhesive.The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panel on all four sides of the panel. The PVC Strips of 5mm ( ± 0.25 ) thick PVC Sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both the panels, using solvent cement. 900 heat bent strips of 5mm thick PVC sheets of width 75mm x 75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.(make:- Rajshri Or Equivalent As approved by GE)
S&F Frameless Main door using 12mm clear float toughened Glass Door having encraved emblem of Sqn (entire elevation area of the main door shall look glass with patch fittings only, no wooden or plywood sections/panels). The cost to include all hardware required viz.,Dorma or approved equivalent make floor springs, patch fittings etc its accessories,top pivot, center lock, 300mm glass door handle etc.shall be provided. 3M privacy film to be pasted as per design and directions. The rate is for a finished item of work etc., Supporting work to be/ extended up to rcc slab level shall not be paid for separately complete all as specified and directed by engineer in charge.
S&F 12mm thick automatic sliding glass door with microwave sensor operated/remote control operated/ push button operated/biometric operated/ manually operated during power breakdown having opening and closing speed 100-750mm/sec(adjustable), door leaf weight 180 kg per leaf, including brushless DC 24 V Servo motor with suitable hinges, rollers and sliding mechanism suitable complete all as specified.
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, Switch Socket, ceiling rose, pendent, holder, by unscrewing from board ,out let box, and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for concealed point wiring approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular frame plate cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following : (a) One light/ Fan/Exhaust fan/Wall mounted fan point controlled by one way switch. Note:- Making good to the disturbed surface to match with the existing finish of wall is deemed to be included in the quoted rate.
(b ) One 5 Amps switch socket combination on independent board.
All as per item No-57 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F modular switch flush type single pole one way 6 Amps,1 module complete all as specifed and directed.
S&F moduler switch socket 6 Amps -2/3 pin combined 2 module, complete all aspsecified and directed.
S&F Modular Switch socket 6/ 16 Amps 2/3 Pin combined 2 module complete all as specified and directed.
S&F modular fan regulator Step type 120W 2module complete all as specified and directed.
S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
Supply and fixing 8 Watt Recess mounted fixed LED down light made of extruded aluminium housing and high power LED as light source with diffuser and driver complete all as specified and directed by Engr-in-charge. Make :- Havells/Philips/Orient
Supplying, fixing & testing decorative recess mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories and PIR sensor/motion sensor ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Cat Part No Havells-VENUSNEOHE2XR36WLEDD84PIRSENSOR Racess mounted 2x2 LED or equvlent Philips/CG
S&F ceiling rose surface backelet ISI marked , 2 to 3 terminal all as specified.
S&F, DB sheet metal enclosure 4 way double door SPN.
S&F, DB sheet metal enclosure 8 way double door SPN.
S&F MCB SPN 10 to 40 Amps all as specified and rupturing capacity 10 KA,
S&F MCB single pole 5 to 16 Amps all as specified and rupturing capacity 10 KA,
S&F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one MCB SP 20 Amps, 230 Volts, 10 KA 'C' series complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick burried directly in grond earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.50 mtr and below nomal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No-5 conneced to earthing test point all as specified or indicated including testing on completion. Note:- 1. GI Earth lead up to 7.5m is deemed to be included in the quoted rate. 2. Necessary excavation, refilling PCC chamber cover, GI pipe, funnel is deemed to be included in the quoted rate.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two runs of 4.0sqmm copper wire & One runs of 4.0sqmm copper wire and conduit shall be meaured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two runs of 6.0sqmm & One runs of 6.0sqmm copper wire and conduit shall be meaured as one unit.
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Four runs of 10.0sqmm copper wire & Two runs of 10.0sqmm copper wire and conduit shall be meaured as one unit.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 16 Sqmm 4 core complete all as specified and directed.
Excavation in trenchesn exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in any type soil etc complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft/loose soil etc complete as specified and directed
Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. (Note :- Only punned down thickness shall be measured for payment).
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge. Make :- Mahatab/Ravi/Duracoat
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specifed and directed.
Supply and fix wall mounted fan 450 mm sweep having oscilating motion and speed control facility complete with accessories 230 V,single pole and connecting up including provision of cable from ceiling rose or connector to fan complete including Cutting out holes in existing cement concrete / brick walls built in cement mortar and removing unserviceable / loose and supplying, fixing & grouting new purpose made arrangements all as directed including making good the disturbed surfaces to match with the existing surface & finishes . Complete all as specified and directed.
Supply and fixing GI 1.2 mm thick perforated cable tray of size 100mmX250mm for giving support/hide and to route electricals cables, communication cable etc to the different parts of building complete all as specified and direced.
Taking down the exisitng detectors for refixing the same as directed by the Engr-in-charge. Note :- The quoted rate against the item includes the cost of labour & material for removing, stacking safe custody and refixing of false ceiling, AC ducting grill and making good the disturbed surfaces after wiring/conducting/installation of fire detectors whereever applicable as per site condition.
Supply,install and testing of detectors complying with and type certified to EN-54 addressable type multisensor detector with heat and smoke combination photo electric/optical with base as per IS 11360 complete all as specified and directed by Engr-in-charge. Note :- The quoted rate against the item includes the cost of labour & material for removing, stacking safe custody and refixing of false ceiling, AC ducting grill and making good the disturbed surfaces after wiring/conducting/installation of fire detectors whereever applicable as per site condition.
Material and labour for fire alarm point wiring with two 1.5 sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLSH cable 1100 volts grade drawn through in and including rigid stove enamelled steel conduit medium grade not less than 20mm dia with its accessories including two coats of painting over conduit with sythetic enamel paint of colour/shade as approved by GE & making good the distrubed surface complete all as specified and directed. Note: (i) Two runs of 1.5 sqmm copper wire + one run of MS conduit of one metre length shall be considered as one unit (i.e. One RM) for purpose of measurement of this item. (ii) Wiring shall be provided on surface of wall / ceiling as directed by GE.
Supply, install & commissioning of split type non inverter type wall mounted air conditioner of capacity 1.5TR (6000K Cal/hr) single phase. Non CFC/HCHC suitable for 230 volts +10% 50Hz AC supply complete with cordless remote control unit complete compressing of following:- (a) Indoor unit wall mounted with copper tube and aluminium blue fins duly coated with specialist chemical to prevent refrigerent leakage. (b) Outdoor unit comprising of hermetically sealed compressor ECO friendly refrigerent, condenser motor, copper condensing coil with copper tubes and aluminium blue fins duly coated with specilist chemical to prevent refrigerent leakage. (c) Refrigerent copper pipes for sunction and discharge line with insulation condensing water drain pipe and protected by suitable size of flexible PVC conduit with control valves and saftey accessaories including control wiring for evaporator and condensing unit with suitable size copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on walls as per manufacturer instructions with necessary grouting MS holdfast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5TR AC complete all as specified and directed. (f) Electrical cable required to connect outdoor unit and indoor unit to voltage stabilizer inclusive in above rate.
Supply, install, commissioning and testing of commercial Air curtain unit of size 60 inch door opening for prevention of dust and Conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified.
M/S Pramod Kumar Jain
Lall Electronics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .