| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹7.9 L+₹14,670 (1.90%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹8.5 L+₹79,985 (10.3%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹8.7 L+₹98,890 (12.8%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹9.4 L+₹1.6 L (21.1%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
3 Mar 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI Pranav, AGE I AF MANAURI
AGE (I) AF Manauri PrayagRaj- 212212
REPAIR / MAINTENANCE OF COOLING APPLIANCES UNDER AGE(I) AF STATION MANAURI
2022_MES_505698_1
8948/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri
As per NIT of Tender
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
12 Mar 2022
4 Feb 2022
4 Mar 2022
4 Feb 2022
3 Mar 2022
19 Feb 2022
60 days
Amount
AIR CONDITIONING WORK :- Taking out to air conditioner window/ split type in cap upto 2 Ton for replacing to u/s spares /re-painting /carrying out neccessary repairing works/ gas re-filling etc in any specification all as site requirement with connecting accessories from existed location after removing all connections safely and transportation from site to work shop and back as same (if required) after repairing work complete all as directed. Note :- Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii) All spares shall be measured and paid against respective items .
All as per item No 1 above but split type capacity above 2 ton to 4.5 Ton (TR).
Re- fixing / installation/ connecting/ testing and commissioning of repaired air conditioner cap upto 4.5 Ton under above item in original postion all as same as per exsited incl making all type of connections such as electric, air pipe line etc with other site required work for serviceablity complete all as directed .
M&L for servicing, removing and re-fixing ,cleaning oiling, dusting, tesing etc of air conditioner in any specification / type/model / cap etc upto 2 TR out/ in door both unit for making serviceable smoothly as pre-mansoon welcome maint incl replacing to required minor spare as wire cable/ remote unit/ 3 pin top plug, copper connection cable (on as required) etc complete all as directed.
All as per item No 4 above but capacity 4.5TR tower type incl indoor evaporator unit, replacment/ cleaning of filters etc complete all as directed.
All as per item No 4 above but capacity 10 Ton package type incl duckting indoor evaporator unit, replacment/ cleaning of filters etc complete all as directed.
Supply, fixing, testing, comissioning in replacement of under mentioned spares against Srl No 7.01 to 7.26 for air conditioner window / split type of cap 1.5/ 2 Ton/4.5 TR as required in original manufactures complete all as directed. Note :- (i) All spares shall be hold original manufacture tag with cat no. (ii) Contractor shall be provided the test certificate and warranty card issued by original manufacure for all compressor covered under this Sch. Make: Brand/ Manufacturer as installed at site.
Reciprocating / rotary type compressor unit in original for window AC cap 1.5/2 TR. Make:- Copeland Scroll or Equivalent as approved by E-in charge.
Reciprocating / rotary compressor unit for split type AC cap 1.5 TR. Make:- Copeland Scroll or Equivalent as approved by E-in charge.
Reciprocating / rotary compressor unit for split type AC cap 2 TR. Make:- Copeland Scroll or Equivalent as approved by E-in charge.
Heavy duty Reciprocating / rotary compressor unit for tower type AC cap 4.5 TR. Make:- Copeland Scroll model ZR61KS-TFD 522 or Equivalent as approved by E-in charge.
Starting capacitor/condensor in 6 MFD as site required Make - Sarda/ universal/ Usha
Starting capacitor/condensor in 36 MFD as site required Make - Sarda/ universal/ Usha
Complete condensation unit for out door unit of split type AC cap 1.5/2 TR with copper cooling fence .
Fan motor for indoor unit split type AC cap 1.5 TR
Heavy duty Air fan motor capacity 1/3 HP single phase 2 Amps 920 RPM 250 watt suitable for out door unit split type AC cap 2 TR. Make :- Thermelly protected/ as per sample at site.
Fan motor for indoor unit split type AC cap 2 TR.
Heavy duty Air fan motor capacity 1/3 HP single phase 2 Amps 920 RPM 250 watt suitable for out door unit split type AC cap 4.5 TR. Make :- Thermelly protected Model UH 1109 / as per sample at site.
Main PCB for window type AC cap 1.5 / 2 TR.
Main PCB for split type AC cap 1.5/ 2 TR.
Main PCB for split type AC cap 4.5 TR.
Thermostate for AC cap 1.5/2 TR.
Fan blade set suitable for window/ split type AC cap upto 4.5 TR with fixing screw etc all complete.
Air filter suitable window or split type AC cap upto 4.5 Ton unit Make - As per sample
Automatic sensor unit for window/split type AC cap 1.5/2 ton
Automatic sensor unit for split type AC cap 4.5 ton
Copper capillary tube (suction) 1/2” dia with fixing accessories as flare nut, clamp etc in origional complete.
Copper capillary tube (liquid) ¼” dia with fixing accessories as flare nut, clamp etc in origional complete.
Copper capillary tube (suction) 5/8” dia with fixing accessories as flare nut, clamp etc in origional complete.
Swing motor for indoor unit of split type AC cap 1.5/2 TR
Belt of fan motor in origional all as per exsited suitable for out door unit capacity 10 Ton package type AC.
Single phase preventer 415 volts 50 Hzs suitable for 4.5 TR split AC complete. Make:- Minilec model VSP2 / as per sample at site.
Contactors 3 phase 25 amps 415 volts 50 HZs suitable for 4.5 TR split AC complete. Make:- L&T model as per existing.
M&L for shiftting / disconnecting / reconnecting servicing cleaning oiling all as per site to split type AC capacity upto 2 Ton incl factory made GI brackets out door mounting unit with nut bolt washer etc gas- re-filling, leakage reparing soldering complete all as site works and directed.
Supply and re-filling of refrigerant Gas (R- 134 A/ R-22/ R-407) in specific grade and packed in seal container for filling up in AC/ De-freezer/ water cooler/refrigerator all cooling appliences in any specification with cutting soldering repairing to leakage etc complete making serviceable all as directed. Note : Acutal re-filled qty shall be measured and paid to contractor.
Water cooler/ Refrigerator and De- freezer work:- Taking out u/s water cooler/ Refrigerator /de- freezer in any make/ model/ capacity etc for replacing to u/s spares /re-painting /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any type/ cap/ make /model all as site with connecting accessories from existed location after removing all connections safely and transportation from site to work shop and back (if required) at same after carried out repair work complete all as directed. Note :- (i) Connecting accessories will be taken in safy custody under contractor for re-using at same. (ii) All spares shall be measured and paid against respective items .
M&L for servicing, oiling, greasing, cleaning, dusting overhauling to water cooler/ Refrigerator and de- freezer in any make/ model/ capacity etc all as site required works for making smoothly serviceable as welcome maint including replacing minor spares (if required) as setting switch/ lock and key/ PVC mounting post/ rubber bedding / top plug etc re-fixing testing connecting repairing of leackage / soldering etc all as site and directed.
Supply fixing and testing in replacement of under mentioned spares against Srl No 12.01 to 12.12 suitable for refrigerator/ water cooler/ de-freezer in any capacity / make/ model/ type etc as site in original manufactures complete all as directed. Make:- Brand/ Manufacturer as installed at site.
Compressor unit for water cooler of cap 40/80 ltr storage capacity.
Compressor unit for water cooler of cap 150 ltr storage capacity.
Compressor unit for water cooler of cap 165 to 310 ltrs ltrs capacity
Evaporator assembly suitable for de-freezer capacity upto 310 Ltrs
De-humidityfier suitable for any specification Refrigerator complete.
D. frost motor suitable for any specification Refrigerator / De-freezer complete.
Main PCB suitable for any specification Refrigerator complete.
Thermostate suitable for any specification refrigerator/ water cooler/ de-freezer complete.
Capacitor 4.5 MFD suitable any specification refrigerator/ water cooler/ de-freezer complete.
Blower motor suitable any specification refrigerator/ water cooler/ de-freezer complete.
Copper capillary tube assembly suitable any specification refrigerator/ water cooler/ de-freezer complete.
Timer assembly suitable any specification refrigerator/ water cooler/ de-freezer complete.
S&F in replacement over load relay suitable for any specification Refrigerator / De freezer and air upto 4.5/ 10 TR package / tower/ split/ window type etc all complete.
S&F in replacement (concealed in surface of wall) industrial socket in sheet enclosure 32 amp three phase (3P+N+E) 415 volts ISI marked with top plug in existing specification including making all connections complete all as specified and directed.
S&F in replacement Metal plug top 32 Amp three phase 23 volts 3 pin vertical mounting complete all as specified and directed.
S&F in replacement of outdoor units suitable for split type AC 1.5 TR (1500 watt) cooling capacity 5275 watts 5 star rated dual invertor single phase 230 volts 50 Hzs in original with intallation copper pipe in std size , intially gas charging, factory made GI mounting stand with nut,bolt & washers etc complete. Make:- Outdoor unit shall be of Make LG, Model KS-Q18ENXA. AMLG / LSA 5NR5 CIG (ANMEUI-1) or equivelent model in Hitachi/ Voltas/ Carrier/ Blue star/ Usha-Daikin
S&F in replacement of air condition indoor units cap 1.5 TR in put voltage 1500 Watt and cooling capacity 5275 W split type suitable for 5 star rated out door unit in original complete with accessories Make:- Indoor unit shall be of Make LG, Model LSA5NR5CIG. ANMEUE1 or equivelent model in Hitachi/ Voltas/ Carrier/ Blue star/ Usha-Daikin
Desert cooler :- M&L for servicing/ maint cleaning oiling greasing scraping removing of dust particals of desert cooler in any spefication at existing location in pre mansson seviceablity incl replacment of spares as condensor/ top plug/ copper cable etc reparing of water tank leakage etc all making seviceable and re-fixing as same complete all as directed. Note:- Quoted rate shall be deem to included cost of required spares mentioned in item for making servieable.
M&L for painting to complete body of desert cooler in all specification by spray gun using syenthic enamel paint on out side and black bituminious paint on inside of body in two coat over one coat of red oxide and marking MES Sr No in diffrent colour after removing / scraping/ washing to rusted particals for preparing to body surface incl replacement to unsv nut bolt , condensor copper connection cable, top plug ,greasing oiling re-fixing all making serviceable at same complete all as directed.
M&L for re-winding to burn out winding of desert cooler fan motor single phase electric driven in all spcefication 450 mm sweep heavy duty using supper enamled insulated copper wire with insulated material , warnishing heating in existing qty, gauge, no of turns etc incl removing burn out winding repacement of bearing ,packing , bushes nut bolt washer bushes nut bolt washer , re-assembling as same etc all complete all as directed. Note:- Quoted rate shall be deem to included cost of required spares mentioned in item for making servieable.
S&F in replacement ball bearing suitable for 450 mm sweep heavy duty desert cooler motor with set of bushes / packing complete. Make:- Tata/ SKF/ NBC
S&F in replacement fan condensor 4.5 to 6.5 MFD suitable for desert cooler 450 mm sweep complete.
S&F in replacement 3 pin 15 Amps top plug complete.
S&F in replacement inter connection water PVC tube / pipe suitable for desert cooler complete Make : As per sample at site.
S&F in replacement of water pump motor cooper wound water proof body 23watt (minimum) capacity, 220/240 volts, single phase, 50Hz having lifting height 2 metre suitable for heavy duty desert cooler with fixing accessories complete . Make : Crompton/Vansal/Bajaj
S&F in replacement water vapor wood wool/ grass wool pad for desert cooler in any size/ make/ model capacity all as existing complete. Make:- As per sample.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
Bharat Trading Company
Ajanta Motor Store
M/s M A Traders
M/s Techno India and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .