Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr Quoted ₹5.9 Cr | L1 | Accepted-AOC The lowest and negotiated tenderer M/s. Chendur construction company |
| Sl No | Description | Qty | Unit | chendur construction company L1 |
|---|---|---|---|---|
| 1.00 | 1.1 : Earth work excavation in all soils (including refilling)
a. 0 to 2 mt. | 764.2 | 1 Cum | 200 ₹1.5 L |
| 2.00 | 1.5 : Earth work excavation for Open foundation (excluding refilling)
a. 0 to 2 mt. | 1,654 | 1 Cum | 200 ₹3.3 L |
| 3.00 | b. 2 to 3 mt. | 21.2 | 1 Cum | 200 ₹4,240 |
| 4.00 | 1.6 : Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m
a. 0 to 2 mt. | 10.9 | 1 Cum | 200 ₹2,180 |
| 5.00 | 2.6: Supply and Filling of 40mm HBSJ | 2.9 | 1 Cum | 1,500 ₹4,350 |
| 6.00 | 2.7: Supply and Filling of 20mm HBSJ | 2.9 | 1 Cum | 2,000 ₹5,800 |
| 7.00 | 7.2 : Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint | 69.4 | 1 Sqm | 600 ₹41,640 |
| 8.00 | 13.1 : Filling with Excavated Earth | 120.9 | 1 Cum | 50 ₹6,045 |
| 9.00 | 21.2 : Teak wood Wrought & Put up
a. T.W. over 2 m & below 3 m | 1.29 | 1 Cum | 1,30,000 ₹1.7 L |
| 10.00 | b. T.W. below 2 m length. | 1.22 | 1 Cum | 1,30,000 ₹1.6 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹3.1 L
Closing Date
10 Nov 2025, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Construction of Fire and Rescue Service Station with development works at Kattumannarkoil in Cuddalore District.
2025_TNPHC_613636_1
SE/NC/DB/2843 /2025
Open Tender
Civil Works
240 days
Kattumannarkoil in Cuddalore District.
Construction of Fire and Rescue Service Station with development works at Kattumannarkoil in Cuddalore District.
9 documents required · 9 mandatory
₹0
₹3.1 L
9 Jan 2026
13 Oct 2025
12 Nov 2025
13 Oct 2025
10 Nov 2025
13 Oct 2025
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.6 : Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 mt.
2.6: Supply and Filling of 40mm HBSJ
2.7: Supply and Filling of 20mm HBSJ
7.2 : Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
24 : Manufacturing & supply of steel windows (Weight basis)
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering course
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.3 : Supply and planting avenue trees
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
53.3 : C.I. Steps ( 5 kg)
55.2 : Flat Back Urinal
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
112 : S & F of Exhaust Fan 300 mm dia
ANNEXURE-I 2.1.1 : Supplying and filling with Gravel (Including Tax Collected by Govt per Cum)
2.1.2 : Supplying and filling with well gravel
2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
3.9.1 : PCC 1:3:6 for foundation & basement using 20mm metal (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM²
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Stilt / Ground Floor
c) In First Floor.
d) In Second Floor.
9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
c. In Second Floor
10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floors a. In Foundation and basement
b. In Stilt / Ground Floor
c. In First Floor
d. In Second Floor
11.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 70mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
12.1.1 : Brick partition work in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First floor
14.1.1.I : Precast Cupboard slab 20 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Stilt / Ground floor
b. In First floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) b. In Stilt / Ground Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix. (using crushed stone sand) a. In Ground Floor
18.1 : Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.For Vertical wall
f. Curved surface
g.Double centring for Garage
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.5.5.1: Supplying and fixing of solid core flush door shutter of thickness 35mm a) Door size 1200mm x 2400mm (Single Leaf)
22.1 : TW panelled single leaf door shutter (Aluminium fittings with brass screws only) a. 900 x 2400mm. (Single leaf)
22.1.1 : TW panelled single leaf door shutter (Aluminium fittings with brass screws only) b. 750 x 2400mm. (Single leaf)
22.2: TW Double leaves panelled door shutter (Aluminium fittings with brass screws) a. 1200 x 2400mm. (Double leaf)
22.2.1: TW Double leaves panelled door shutter (Aluminium fittings with brass screws) a. 1500 x 2400mm. (Double leaf)
22.2.2 : TW Double leaves panelled door shutter (Aluminium fittings with brass screws) a. 1800 x 2400mm.
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) with plasticizer
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.7 : Plastic Emulsion PAINT including primer for inner walls
38.7.1 : Plastic Exterior Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M20)
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.2.1 : Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150mm (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
50.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5.2 : Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
56.4.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F.(using crushed stone sand)
57.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
58.5 : PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
59.2.1 : Gully Trap using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
b. 160 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
b. 160 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
71.2: Supplying and fixing of 32Amps triple pole main switch with fuse and neutral link
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.2.1: Supplying and fixing of 20 Amps DP Plug & socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection (For AC Plug) Legrand (MDS) / Hanger (L & T) equalivalent / superior variety including cost of material and labour charges for wall cutting, grouting, flushing and making the surface good including earth connections etc all complete and as directed by the departmental officer.
77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.8 : Run of 4 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
80.1: S & F of 450 x 375 x 20mm thick TW plank
87.1: Supplying and delivery of Three phase ELCB/RCCB
90.1: Providing additional strutting to centering of plain surface
98.5.4.2: TW Panelled door shutter with brass fittings (Double leaf) a. 1800mm x 2400mm.
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.1 : Concrete designer tiles flooring (using crushed stone sand)
361.5.1: Vitrified Tiles flooring (ivory) incl. pointing (using crushed stone sand)
367: Providing wooden (melamine) polish for new wood
379.5.1 : S&F of Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2'0 x 1'0 or 1'0 x 1'0 or 1'0 x 0'6 of 10 mm thick (Ruby Red) (using crushed stone sand) a.In Ground floor
448.2: Supply and fixing 32mm dia PVC Tee with end cap
ANNEXURE-II: A1: Providing T.W. double leaf shutters for cupboard/ward robes with 9mm thick phenol bonded bwr grade plywood (For Rest room )
A2: Providing teakwood glazed french window shutters and 5.5mm thick ground or frosted glass for panels including labour charges and cost of furniture fittings as per schedule ‘E' and directed by the departmental officers. a) D1/FW/RV (750mm x 2100mm)
b) D/FW/RV (900mm x 2100mm)
c) D2/FW (1100mm x 2100mm)
A3: Providing Wallputty (One coat) for newly plastered surface
A4: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free.
A5: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free.
A6: Supply and fixing of UPVC Sliding Window (Two track)
A7: Supplying and fixing of 15mm dia CP Two way bib cock with health faucet including cost of all materials and labour charges etc., all complete and as directed by the departmental officers.
A8: Supplying and fixing of LED bulbs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A9: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A10: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A11: Supplying and fixing of 30W LED Street light with necessary fittings (Superior variety) Charges for fixing 30W LED lamp street light fittings
A12: Supplying and fixing of 200mm dia UPVC Exhaust fan fixing in the toilet and bath of approved ISI Quality etc., all complete.
A13: Supplying and fixing of 3 Nos.of 100 amps 500 volts grade porcelain fuse unit on suitable teakwood plank varnished to be fixed on the top of pole EB street pole with necessary clamps including cost of all materials etc., all complete and as directed by the departmental officers.
A14: Supplying and fixing in position of colour galvalume sheet of 0.47mm thick as ridge piece inclusive of overlap length labour charges and nuts, bolts etc., all complete and as directed by the departmental officers. (the quality and the brand of material should be got approved by the executive engineer before use)
A15: Supplying, delivery and fixing of 83mm tk rubber moulded hydraulic pressed paver block including conveyance charges, laying of 83mm thick paver block
A16: Supplying and fixing of MS pipe with 3.6mm thick including cost of all materials including priming coat and all labour charges etc., all complete and as directed by the departmental officers.
A17: Supply and delivery at site and fixing of following size SFRC manhole cover with frame with locking arrangement including cost of all materials and labour charges for fixing in position etc., all complete and as directed by the departmental officers. a. 600mm x 600mm
b. 300mm x 300mm
A18: Drilling the bore well 165mm of dia and anywhere in Cuddalore district including transportion from one place to another with in Tamil nadu in alluvial soil sedimentary strata of sand stone shale pebble boulders etc by first taking a pilot bore of 140mm/150mm dia and then on laying to required dia direct or reverse rotary method circulation method using rotary rings and labour and drilling at site including all charges as per the direction by the departmental officers. a) From 0 mtr and upto 76 mtrs below GL
b) From 76 mtrs upto 90 mtrs depth below GL
c) From 91 mtrs upto 106 mtrs depth below GL
d) From 107 mtrs upto 121mtrs depth below GL
e) From 122 mtrs upto 137mtrs depth below GL
f) From 138 mtrs upto 152mtrs depth below GL
g) From 153 mtrs upto 167mtrs depth below GL
h) From 168 mtrs upto 182mtrs depth below GL
i) From 183 mtrs upto 197mtrs depth below GL
j) From 198 mtrs upto 210 mtrs depth below GL
A19: Reaming from 140/150mmm pilot bore to 300 mm dia bore as directed by the departmental officers a) Upto 60 mtrs depth below GL
b) From 61 mtrs upto 90 mtrs depth below GL
c) From 91 mtrs upto 120 mtrs depth below GL
d) From 121 mtrs upto 150 mtrs depth below GL
e) From 151 mtrs upto 180 mtrs depth below GL
f) From 181 mtrs upto 210 mtrs depth below GL
A20: Labour charges for inserting PVC casing pipes (With slotted/plain pipes) in the drilling holes including the jointing pipes with PVC couplerwith cement paste etc complete as per the direction by the officers.
A21: Supply and delivery of the following dia PVC heavy duty casing pipes of 15 kg/cm² and necessary special of best approved quality etc complete. a) 165 mm dia outer PVC Plain pipes
b) 165 mm dia outer PVC slotted pipes
c) 165 mm dia outer PVC bottom dummy
A22: Labour charges for developing the bore by air compressor of capacity 600 cfn. Using drill rods/holes with required size pipes for various capacity compressor including transportion, labour charges and fuel charges for air compressor as directed by the departmental officers.
A23: Supply and delivery of clear water vertical wet type 5 HP submersible pumpset without panel board suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes.
A24: Supply and delivery of 3 HP Open well Submersible pump set without panel board conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. Duty - lpm x m - 50 x 50
A25: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) For 3 HP
A26: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) For 5 HP
A27: Labour charges for the erection of submersible pumpset in borewell / openwell including fixing and jointing submersible cable with proper clamps upto the starter. Upto 5 HP
A28: Supply and delivery of 3 core 4 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete.
A29: Supply and delivery of 12mm dia Nylon Rope for Bore-well including cost of materials and labour charges etc., complete as directed by the departmental officers.
A30: Supplying and delivery of 50mm dia UPVC Column Pipes of best approved quality with ISI mark etc., complete as directed by the departmental officers.
A31: Supplying and laying of GI pipe "B" class with ISI mark for Below ground level including cost of Eatrh work excavation and refilling ,labour charges, etc complete, all complete and as directed by the departmental officers a) 80 mm dia GI 'B' class pipe
b) 50 mm dia GI 'B' class pipe
A32: Supplying and laying of GI pipe "B" class with ISI mark for above ground level including cost of clamping and labour charges, fixing GI pipes etc complete, all complete and as directed by the departmental officers. a) 80 mm dia GI 'B' class pipe
b) 50 mm dia GI 'B' class pipe
A33: Supplying, laying, fixing and jointing the following ASTM pipes as per IS 4985 suitable UPVC/PVC/GI specials like elbow, tee, reducers, plug, union, bend, coupler, nipple, GM gate valve, check and wheel valve etc and labour charges for earth work excavation, laying, jointing, refilling the earth and cost of conveyance charges with necessary specials etc., all complete and as directed by the departmental officers. (Below Ground level). a) 50mm dia PVC pipe
A34: Supplying, laying, fixing and jointing the following UPVC pipes as per ASTM-D-1785 of schedule (Below Ground level) a) 50 mm UPVC pipe. 10Kg/cm2
A35: Supplying and delivery of following dia GI, GM, CI, PVC and MS specials of best and approved quality having ISI mark etc., all complete. a) 50mm dia UPVC ball valve
b) 50mm dia UPVC Union
c) 50mm dia UPVC Bend
d) 50mm dia UPVC Elbow
e) 50mm x 40mm dia UPVC reducer
f) SS Adopter 50mm dia
g) MS Bore Clamp set 150mm dia
h) 50mm dia GI Elbow
i) 50mm dia GI Hex Nipple
j) 50mm dia GI Union
k) 50mm dia GI Non return valve
l) 50mm dia GI flange set
m) 50mmx40mm dia GI reducer
n) 50mm dia GI Bend
o) 50mm dia GI Tee
p) 50mm dia GI Coupling
q) 80mm dia GI Bend
A36: Supplying and delivery of following God - rej novtal lock including all cost of lock etc., complete. a) 6 Lever with 3 keys
A37: Providing Rain water Harvesting well ring circular shape of 90cm dia, 60cm depth and 50mm tk using M20 grade concrete including steel fabrication and labour charges etc., complete as directed by the departmental officers.
A38: Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4 P MCB switch as incoming and 18 nos. 6A to 32A SP MCB as outgoing on wall with earth connection etc., all complete as directed by the departmental officers.
A39: Supplying and fixing of following size of Aluminium Dye casting letters with MRF Powder Coating including labour charges for fixing in position cost and conveyance of all materials, T.W plugs, screws metal paste and labour charges etc.,. a) 9" size Aluminium Dye casting letters
b) 12" size Aluminium Dye casting letters
A40: Supplying and fixing of 15" size TNPHC Emblem (Tamil Stainless Steel letters)
A41: Supplying and fixing of following size 24" x 4" and 5" dia plastic foam plate of 3mm thick with 3" height vinyel cutting numbers with approved colours etc., complete and as directed by the departmental officers.
A42: Supplying and fixing of PVC Trims (Beading) at tiles corner with necessary connections etc., (The brand shall be got approved from the Executive Engineer before use)
A43: Providing double nosing to the edges of Granite slab including cost of required tools and machinery and labour charges etc., all complete and as directed by the departmental officers.
A44: Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
A45: Supplying and fixing of 3 Nos.of 63 amps 500 volts grade porcelain fuse unit on suitable teakwood plank varnished to be fixed on the top of pole EB street pole with necessary clamps including cost of all materials etc., all complete and as directed by the departmental officers.
A46: Supply and erection of 125 Amps capacity floor mounting / wall mounting metering panel board (Cubical type) of size 5'x4'x1'6" with bus bar chamber Incoming: 125A mps switch Disconnector with HRC Fuse and 3 nos 200 A Porcelain Fuse unit. Bus Capacity:125A 3phase 4 wire copper flat for phase and neutral. Outgoings: 6 nos. metering chamber each chamber containing 6 no 63A switch Disconnector with HRC Fuse also necessary wiring with 19/6 PVC insulated copper wire and including pilot lamp, Labour charges for erection transporting charges and etc., all complete and as directed by the departmental officers.
A47: Supply and Laying of following LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good ,including cost of materials and transportation charges etc all complete and as directed by the departmental officers. a) 3.5 core 50 sqmm LTUG cable
b) 4 core 16 sqmm LTUG cable
A48: Supplying and providing cable end termination of following sizes of XLPE armoured LTUG cable, including labour charges etc all complete and as directed by the departmental officers. a) 3.5 core 50 sqmm LTUG cable
b) 4 core 16 sqmm LTUG cable
A49: Supply & fixing of Cable gland suitable for following PVC armoured LTUG cable etc., complete. a) 3.5 core 50 sqmm LTUG cable
b) 4 core 16 sqmm LTUG cable
A50: Supply & fixing of 63 amps three phase 500 V 4 pole Change over switch including labour charges etc., all complete and as directed by the departmental officers.
A51: Supply & fixing of 63 Amps triple pole main switch for incoming control and 2 no of 16 A etc., complete and as directed by the departmental officers.
A52: Supply and fixing of 150W LED street light fitting with LED(Lower end) with 40mmdia.GI pipe (class B) with 1no.40mm GI bend complete on the existing post /onwall with PVC unsheathed copper leads with MS clamps and with painting.
A53: Supplying, delivery, fixing and commissioning of Single phase Online UPS (Single phase IN and Single phase OUT) to a Capcity of 5.5KVA (inbuild with isolation transformer with 2 Hours Backup power, including the cost UPS and installation charges etc all complete and as directed by the departmental officers. (The UPS got approved from the Executive Engineer before installation)
A54: Supplying, delivery, fixing and commissioning of Online UPS EXIDE EP65-12 SMF Battery (24Months warranty) with ISI mark including the battry and installation charges etc all complete and as directed by the departmental officers.(The UPS got approved from the Executive Engineer before installation)
A55: Supplying and fixing in position of UPS & Battry Rack and inter link connection charges etc.,all complete and as directed by the departmental officers.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 8.53 MB
PQBookletKattumannarkoil.pdf
Additional Documents • 1.10 MB
TenderDocKattumannarkoilFire.pdf
Tender Documents • 4.79 MB
BOQ_733182.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid