COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST BANGALORE 560006
REPAIR MAINTENANCE OF HT SYSTEM INCLUDING HT SWITCH GEARS TRANSFORMERS AND CONNECTED WORKS AT CHAF UNDER GE (AF) BANGALORE
2024_MES_662966_1
87446CWEAFNBAN
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (AF) BANGALORE
₹62,500
Yes
21 Oct 2024
29 Jun 2024
11 Sept 2024
1 Jul 2024
4 Sept 2024
22 Jul 2024
1 Jul 2024 - 9 Jul 2024
Amount
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /loose soil for laying of cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm complete all as specified and directed.
Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M & L River sand, spread dry in trenches as in cable cushioning complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm laid in trenches as in protection of UG cables complete all as specified and directed.
M & L for locating UG cable fault using Microprocessor based fault locator suitable for low/medium and high volatge up to 11KV, XLPE/ PVC/ PILC of Aluminium/ Copper cables under trenches/ RCC surface & on wall for finding OC/ SC/ Flashing faults with any one of the suitable methods Time domain reflectometer method (TDR)/ Secondary impulse Method (SIM)/ Impulse Current method (ICM)/decay Method to achieve pin point fault location up to 5 Km distance complete all as specified and directed. (Note : Quoted cost deemed to be included all accessories , equipments and labour cost)
M & L for filteration and dehydration of transformer oil on line by using streamline filteration plant the dielectric strength to be brought to not less than 60 KV (at 2.0mm gap for 1 minute) and testing the oil sample after dehydration complete all as specified and directed. Note: - (i) Test result before and after filteration to be recorded as per the sample provided by Engr-in-charge. (ii) The rate quoted deemed to be included for taking necessary connection and the connection to filteration plant from transformers and switchgear oil duly removing the inlet and outlet connections. (iii) For topping up transformer oil will be measured and paid separately under relevent items. iv) The rate quoted deemed to inclusive of testing charges.
Collecting the oil samples of transformers /voltage stabilizers installed at CHAFB areas after filteration and dehydration and carrying out testing the oil from NABL accredited Laboratory and as per IS 335:1993 detail analysis of physical, chemical & electrical parameters including dissolved gas analysis, Furan Analysis etc and full report is submitted on printed form for each transformer oil samples tested complete all as specified and directed.
M & L for filling insulating oil (transformer oil) confirming to IS-1866:2000 having dielectric strength not less than 60 KV for topping up in 11/0.433 KV transformer all as directed (Filling shall be done by on line filtration plant only) Make. Sarita/HP
S & fix in repairs of air breather any type upto 630 KVA transformer complete with filled silica gel complete all as specified and directed.
S & Fix in repairs silica gel for up to 630 KVA transformer of any make type and capacity complete all as specified and directed.
S & Fix in repairs of oil temperature gauge upto 630 KVA transformer complete all as specified and directed.
S & Fix in repairs of set of gasket such as top cover, conservator, bucholz relay, breather etc for transformer capacity upto 630 KVA complete all as specified and directed.
M & L for painting the transformer indoor/ outdoor of capacity ranging from up to 630 KVA after preparation of surface and applying two coats of synthetic enamel (matching existing colour) paint on old steel surface and marking serial no, MES No, SM No, date of installation etc complete all as specified and directed.
M & L for painting the compact substation including transformer, SF6 breaker and canopy complete of capacity ranging from up to 630 KVA after preparation of surface and applying two coats of synthetic enamel (matching existing colour) paint on old steel surface marking serial no, MES No, SM No, date of installation etc complete all as specified and directed.
S & fix in repairs of HT 11 KV bushing porcelain with copper alloy terminals for transformer of capacity upto 630 KVA including dismantling unserviceable complete all as specified and directed
All as per item 16 here-in-before but LT bushings complete all as specified and directed.
S & fix in repairs of burnt brass bush connecting rod for transformer up to 630 KVA and refixing new connecting rods with oil seal o-ring, nuts, washers etc complete all as specified and directed.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M & L for servicing of two pole structure complete including repairs of unserviceable jumpers with PVC 50 Sqmm aluminium cable single core, vice type connectors, bolts nuts washers connecting lugs/thimbles knife contacts, applying petroleum jelly to the moving as well as fixed contacts tightening all the connections for its smooth functioning and preparing the old painted surfaces of the structure such as poles, cross arms, bracing and supports clamps back plates complete painting of two coats of anticorrosive aluminium paint over a coat of redoxide zinc chrome primer and providing yellow and black paint from the ground level at site as directed by Engineer-in-charge complete all as specified and directed. Note: - No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule.
M & L for spread stone aggregate of size 40 to 90 mm grade complete all as specified and directed.
Supply and fix in repairs of switches air break gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps 11000 volts complete all as specified and directed.
Supply fix in repairs of Male moving contacts blades for Gang operated/ Air break switch assembly with proper nuts, bolts and applying non corrosive petroleum jelly complete all as specified and directed.
Supply fix in repairs of Female fixed alloy contacts jaws for Gang opertaed/ Air break switch assembly with proper nuts, bolts and applying non corrosive petroleum jelly complete all as specified and directed.
Supply fix in repairs PVC sheathed stranded aluminium conductor cable of size 70 sqmm Single core for jumper due fixed on GOD with D clamps complete all as specified and directed.
Supply fix in repairs pin type porcelain vitreous, white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 150mm height 150mm dia 11000 volts grade including taking down old unserviceable insulator complete all as specified and directed.
Supply and fix lightening arrestor expulsion type suitable for HT 11 KV installation out door use complete with all fittings transmission class discharge 65 Kilo Amps including taking down the unserviceable complete all as specified and directed.
M & L for cleaning, dusting and servicing for the smooth functioning electronic float cum boost battery charging unit suitable for HT VCB panel 110/220 volt DC with sealed battery bank of 2 volt, 100 AH with connection fixed inside MCB control for input circuit, DC out put circuit, tightening the cable connection incoming and out going etc complete all as specified and directed.
Supply & fix in repairs of drop out fuses capacity 20 Amps to 40 Amps complete all as specified and directed. Make: Jayapuria /Bussmann or Equivalent
S & fix in repairs of HT Bottle fuse 100 Amps for load breaker switch controlled complete all as specified and directed at site. Make : Cooper Bussmann/SIEMENS
M & L for repair/ maintenance, cleaning, dusting and servicing Vacuum Circuit Breaker, HT 11 KV, 50 Hz, 630 Amp indoor switch gear panel by grounding of complete panel live parts, thorough cleaning, visual checking, tightness checking and servicing of breaker panel including breaker carriage along with associated mechanism, metering panel, busbar/ cable chambers, motorised spring charging mechanism, DC shunt trip/close coils, operation counter, manual spring charging mechanism, relays, meters, indicators, heater coil, aux supply SMPS, replacing of worn out parts and fuses, applying petroleum jelly to moving and fixed mechanical parts for its smooth functioning all and Decarburizing/ cleaning complete HT 11KV, 3 phase independent bus bar, bus bar chamber of HT panel electrification after removing the complete bus bar spout, circuit spout from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system all as directed by the Engineer in charge at site complete all as specified and directed. Note: Rate quoted is inclusive of bactol red, CTC & cotton waste provided by contractor.
M & L for repair/ maintenance, cleaning, dusting and servicing, for the smooth functioning of 3 way compact RMU, HT 11 KV, 630 Amp, 3 phase 50 cycle by grounding of complete panel live parts, thorough cleaning, visual checking, tightness checking and servicing of breaker panel including breaker carriage along with associated mechanism, metering panel, busbar/cable chambers, self powered over current and earth falult relay, T-off SF6 circuit breaker module, mechanical fault/ on/ off indicator etc and replacing worn out parts when required etc and confirming smooth reliable operation of RMU unit complete all as specified and directed.
M & L for repair/ maintenance, cleaning, dusting and servicing of standalone/ Compact substation SF6 Circuit Breaker, HT 11 KV, up to 630 Amp, 3 phase 50 cycle totally enclosed out door type application switch gear by grounding of complete panel live parts, thorough cleaning, visual checking, tightness checking and servicing of breaker panel including breaker carriage along with associated mechanism, metering panel, busbar/ cable chambers, motorised spring charging mechanism, DC shunt trip/ close coils, operation counter, manual spring charging mechanism, relays, meters, indicators, heater coil, aux supply SMPS, replacing of worn out parts and fuses, applying petroleum jelly to moving and fixed mechanical parts for its smooth functioning as directed by the engineer in charge complete all as specified and directed.
M & L for repair/ maintenance, cleaning, dusting and servicing for the smooth functioning of oil cooled servo voltage stabilizer upto 75 KVA 3phase by grounding of complete panel live parts, thorough cleaning, tightness checking and servicing of servo motor, Auto transformer, control circuit, Aux power transformer, bearing, control relays, contactors including checking of loose wiring along with associated mechanism and replacing worn out parts etc and testing, confirming smooth reliable operation of voltage stabilizer unit complete all as specified and directed.
M & L for decarburizing/ cleaning complete HT 11KV, 3 phase independent bus bar, bus bar chamber of HT panel electrification after removing the complete bus bar spout, circuit spout from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system complete all as specified and directed. Note: Rate quoted is inclusive of bactol red, CTC & cotton waste provided by contractor.
M & L in repairs of terminal protector boot straight/ right angle type having insulating capacity of 11/22KV rating for having protection from short circuit due to intervention by reptiles, birds, animals in cable entry box for transformer/ VCBs/ RMU/ SF6/ OCB breakers complete all as specified and directed.
M & L for refilling/ topping up SF6 (Sulpher hexa fluoride) gas charging/ top uping in existing RMU/ SF6 circuit breaker upto specified operating level (min pressure 2.8 Kg/cm2) and conduct gas leakage test and arrest leakage if any complete all as specified and directed.
Supply and fix in repairs of LED indicator light red, blue, yellow & green for 110 Volts for HT 11 KV panel all including taking down the unserviceable complete all as specified and directed.
Supply and fix in repairs of push button with 1 NO + 1NC on existing HT VCB Panel complete all as specified and directed. Make : L &T / Siemens / Schneider or Equivalent
Supply and fix in repairs of rotary switch for local / remote/ neutral/ trip/ close function on existing HT VCB/ SF6/ OCB Panel complete all as specified and directed. Make : L &T / Siemens / Schneider or Equivalent
Supply and fix in repairs of Digital multifunction meter with PT/ CT (0-110v)/ (0-1/5A) operated for measuring votage /Ampere /Power factor /frequency etc on existing HT VCB/ SF6 Panel complete all as specified and directed. Make : Schneider /L&T/AE/MECO/SELEC or Equivalent
supply and fix in repairs of resin type PT 11KV/110V for phase with fuse, 11KV/110V with burden of 100VA, Accuracy 0.5 as existing type, complete suitable for HT 11KV panel, testing and commissioning after completion of the work complete all as specified and directed. Make : Kirloskar/Crompton /ABB or Equivalent
Supply and fix HT 11 KV current transformer dual core epoxy insulation type as existing CT ratio including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ ABB
S & F in repairs of SMF gel tubular VRLA 2 Volts 100 Ah battery for battery bank system including connecting copper lead, thimbles, nuts, bolts, washers etc complete all as specified and directed. Make: Amaron
Supply and fix in repairs of panel space heaters 80-120 watts coil element AC 230 Volt input suitable for HT VCB panel of any make fixed inside with suitable clamps, bolts and nuts complete including necessary wiring cable connection complete all as specified and directed.
Supply and fix in repairs of thermostat switch for controlling the space heaters temperature settings AC 230 Volt input suitable for HT VCB panel of any make fixed inside with suitable clamps, bolts and nuts complete including necessary wiring cable connection with control toggle ON-OFF switch - 01 No complete all as specified and directed.
Supply and fix in repairs damaged HT breaker cluster contacts male/ female / isolating/ moving/ fixed contacts 630/400 amps for VCB/ OCB/ RMU/ SF6 type breaker complete all as specified and directed. Make Kirloskar /ABB or Equivalent
Supply and fix closing coil complete with all accessories suitable for HT 11 KV VCB 400/630 Amps complete including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ABB
Supply and fix tripping coil complete with all accessories suitable for HT 11 KV VCB 400/630 Amps including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ABB
Supply and fix epoxy spout insulator of HT 11 KV VCB 400/630 Amps including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ABB
Supply and fix in repairs of CAM wheel assembly suitable for VCB of existing make HT 11 KV, 400/630 Amps capacity complete with all accessories complete all as specified and directed. Make: Kirloskar/ABB
Supply and fix in repairs of spring charging motor suitable for VCB of HT 11 KV, 630 Amps capacity complete with all assembly/ accessories complete all as specified and directed. Make: Schneider/ Kirloskar/ ABB
Supply and fix spring charging gear assembly with all accessories suitable for HT 11 KV VCB 400/630 Amps complete including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ABB
Supply and fix catch /latchet assembly complete with all accessories suitable for HT 11 KV VCB 400/ 630 Amps complete including taking down the unserviceable complete all as specified and directed. Make: Kirloskar/ABB
M & L for calibration and testing of tripping system of HT 11 KV OCB/ VCB/ SF6/ compact substation circuit breaker by injecting fault current on primary side of CT/PT, setting the OL/ inverse time /earth fault level and ensure that HT breaker tripping system function properly as per relay setting and submit calibration test certificate duly signed by contractor complete all as specified and directed by engineer-in-charge.
M & L for painting the VCB of capacity ranging 630/400 Amps after preparation of surface and applying painting of two coats of anti corrosive smoke grey paint over a coat of redoxide zinc chrome primer out side surface of the metallic enclosure including writing MES No, SM No, date of installation etc complete all as specified and directed by the engineer-in-charge.
M & L for painting the SF 6 /RMU of any capacity ranging after preparation of surface and applying painting of two coats of anti corrosive smoke grey paint over a coat of redoxide zinc chrome primer out side surface of the metalic enclosure including writing MES No, SM No, Date of installation etc complete all as specified and directed by the engineer-in- charge.
M & L for cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 185 sq mm including taking down the unserviceable complete all as specified and directed by the engineer-in- charge.
M & L for repairs of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 120 sqmm to 185 Sq mm complete all as specified and directed.
M & L for repairs of cable jointing kit for 11 KV (earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor able of size 120 sqmm to 185 Sq mm complete all as specified and directed.
M & L for repair/ reconditioning of exisiting earth pit by removing damaged earth PCC chambers and excavate pit soil upto 25% of earth plate/ electrode and adding alternate layers of charcoal, mixture of salt and copper sulphate up to 15cm above the earth plate/ electrode and moist the mixture using water, cleaning/ replacing of funnel with wire mesh wherever necessary contractor should ensure that the earthing resistance should be below 5 Ohms, making good to disturbed surface and complete all as specified and directed at site. Note: 1. Deemed including excavation, returning filling in and connected items. 2. Salt, charcoal, pit cover will be measured and paid seperately
Supply only pure charcoal granular/aggregate type having Ash content < 5%, stone free for earthing.
Supply only iodine free pure common salt crystal ( NaCl) for earthing.
M & L for repair/ repairs of earth pit cover with pre moulded cast iron eart pit cover 300mm x300mm x 50mm, provision of funnel, wire mesh necessary excavation and earth work in any type of soil as earth pit complete all as specified and directed.
M & L for test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hexagonal head screw complete fixed on wall in and including sheet steel enclosure of thickness 2 mm thickness with locking arrangement complete all as specified and directed.
Taking down old u/s strip of any description and any size complete all as specified and directed.
M & L for laying earth continuity conductor GI Strip 25 x 4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for direct/ loop earthing with proper PVC/ porcelain insulator etc complete all as specified and directed.
M & L for laying earth continuity conductor GI Strip 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for direct/ loop earthing with proper PVC/Porcelain insulator etc complete all as specified and directed.
S & F in repairs of PVC Polymer insulator for existing GI/ Aluminium/ copper strip support complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised iron wire 4 mm dia by means of bolts,nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 set of SSR pt I, connected to transformer, DG set, LT panel/ DB/ earthing test point including PCC chamber, RCC cover 50mm thick with 8 mm dia bars, protection pipe, watering pipe 20 mm GI, funnel etc including excavation, earth work, disposal of surplus soil including testing on completion all as specified and directed. Note: Earth strip and protection pipe of GI 15 mm bore light grade upto 7.5 metres deemed included in the item .
M & L for synthetic rubber insulated mat 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m including taking down the unserviceable complete all as specified and directed.
M&L danger notice board/plate of 1.6mm thick mild steel sheet vitreous enamelled white with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size of HT 25 x 20 cm size complete all as specified and directed.
Supply and fix in repairs of mild steel nuts and bolts and washers of various sizes complete all as specified and directed.
Repairing/ welding of leaking fins/ body of transformer and making the same leak proof complete all as specified and directed.
Supply and fix in repairs of tinned copper flexible jumper 200/400A rating for Gang operated /Air break switch assembly with proper nuts, bolts and applying non corrosive petroleum jelly complete all as specified and directed.
M & L for preventive maintenance/ repairs to transformer step down 11 KV/ 0.43 KV in door/out door type of any make of 250 KVA - 400 KVA - including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the worn out copper alloy nuts and tightening the earth terminals and conducting various tests as stipulated in the particular specification complete all as specified and directed.
M & L for preventive maintenance/ repairs to transformer step down 11 KV/ 0.43 KV in door/out door type of any make of 100 KVA - 200 KVA - including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the worn out copper alloy nuts and tightening the earth terminals and conducting various tests as stipulated in the particular specification complete all as specified and directed.
M & L for preventive maintenance/repairs to transformer step down 11 KV/ 0.43 KV in door/out door type of any make of 500/630 KVA - including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the worn out copper alloy nuts and tightening the earth terminals and conducting various tests as stipulated in the particular specification complete all as specified and directed.
M & L for maintenance/repairs to tap changer of transformer upto 630KVA capacity, tightening of nuts ,bolts and all check the functioning of all moving parts, including changing all worn out parts such as moving contacts, L-connectors, fixed contacts, mounting blocks etc including testing of tap changer in all positions complete all as specified and directed.
S & Fix in repairs of vaccum bottle interrupter rated 11KV, breaking capacity 31.5 KA, rated current 630A min, including testing complete all as specified and directed.
M & L for detecting faults in HT Installation or trip of breakers HT Panel or defects in 2 pole/ 4 pole/ 6 pole structure checking the cable ends, Terminals, connections etc in CHAFB, No.2 Offrs Mess area and rectifiying the defects for restoring supply including replacing of defective items immediately from the items catered BOQ. Note :- (i) Rate for item required to be replaced shall be measured and paid under respective item of schedule. (ii) Essential material like, insulation tape, screws and all tools required for carrying out the works shall deemed to be included in the quoted rate. (iii) All emergency nature complaints must be attended and completed within 2 hrs as and when assigned. (iv) All other complaints to be attended and completed within 6 hrs as and when assigned (v) Non rectification of complaints in said time shall be penalized at Rs 500- per hour per complaint and recovery shall be made in the payment due to the contractor.
S&F Transformer specification board made out of flexible acrylic sheet of size 2 x 3 feet background of blue colour with white letters of size 50/40mm alongwith all fixing arrangements for different type and model of Transformers as per sample and as directed by the Engr-in-Charge including removing old existing damaged board and accessories complete all as specified and directed.
M & L for painting of outdoor transformer/ VCB/ compact substation plinth after making good surface with two coats of weather proof paint complete all as specified and directed by the Engineer in charge.
M&L for cutting of branches of tree near to the 2/4 pole structure, transformers and cleaning the area by removing grass, plants etc from 1.5 mtr to 3 mtr length from all sides as per availability of ground and complete all as specified and directed by the Engineer- in- charge
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply & laying in repairs of HT 11 KV 3 core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts for cross sectional area of cable 95 Sqmm x 3 Core complete all as specified and directed at site.
Supply & laying in repairs of HT 11 KV 3 core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts for cross sectional area of cable 120 Sqmm x 3 Core complete all as specified and directed at site.
Supply & laying in repairs of HT 11 KV 3 core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts for cross sectional area of cable 185 Sqmm x 3 Core complete all as specified and directed at site.
Supply & laying in repairs of HT 11 KV 3 core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 11000 volts for cross sectional area of cable 240 Sqmm x 3 Core complete all as specified and directed at site.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor straight through cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 95 sqmm complete all as specified and directed.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 95 Sqmm complete all as specified and directed.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 240 Sqmm complete all as specified and directed.
M & L for cable jointing kit for 11 KV (Earthed) grade cable straight through cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluiminium conductor cable of size 240 Sqmm complete all as specified and directed.
M/S - KRUPA ELECTRICALS (BID ID -3073630)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .