Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.8 L+₹53,407.50 (3.28%)Rejected-Finance HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Not Validated (
Other than Lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹36,280
Closing Date
13 Oct 2022, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
PROVISION OF IRON GRILLS 20 NOS AT WINDOWS OF MAIN OFFICE, ADD ALT OF RAILING AT 2ND 3RD 4TH FLOOR AT TRANSIT CAMP AND SPECIAL REPAIR TO BLOOD BANK BLDG NO 2 OF BASE HOSPITAL UNDER GE GUWAHATI
2022_MES_552491_1
GE/GUW/45/8245 OF 2022-23
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹36,280
Yes
3 Nov 2022
16 Sept 2022
15 Oct 2022
16 Sept 2022
13 Oct 2022
30 Sept 2022
16 Sept 2022 - 23 Sept 2022
Amount
S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L preparing new Steel surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Cutting openings, through brick walls for inserting hold fast of grills by openings or cutting out brick work , removing debries from the site and providing PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in hold fast jamb, securing grills or railing etc including formwork as required complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and removing debrires from the site complete all as directed.
M&L Coloured glazed ceramic tiles 350 x 450 x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed.
M&L Rendering 15 mm thick fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed.
M&L preparation of new surface of walls and and applying white cement based wall care putty (minimum 1.5mm thick), apply two coats of exterior acrylic emulsion paint (1st quality) over a coat of alkali resistant primer over complete all as specified and directed
Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed.
S&F Colour coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:-(i) Labour charges for fixing of glass/wire guage is inclusive in the unit rate quoted. Glass/Wire Guage/locks shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated (minimum thickness of powder coating 50 micron) anodised aluminium windows/ventilators/partitions any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
Supply only 5.5mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed.
Supply only 4mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed.
Supply only 4 lever, Mortice lock, vertical type, size 100 mm complete all as specified
Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum window/ventilator shutters complete all as specified and as directed.
S&F Aluminum (extruded body) Door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement complete all as specified and as directed.
Demoliation Cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debries/rubbish from the site complete all as specified and directed.
M&L 25mm thick Cement concrete type B0, (1:2:4) (using 12.5mm graded stone aggregate) as in sub base of flooring for layind floor finishes complete all as specified and as directed.
M&L Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.
Demoliation Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as directed.
M&L 18-20 mm Granite (of any type) thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 20mm thick screed bed or bedding layer cement mortar (1:6) complete all as specified and directed.
M&L complete removal of existing treatment surfaces of walls, preperation of surfaces, applying white cement based wall care putty (minimum 1.5mm thick) and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed
M&L prepration of new plastered surfaces of walls and applying white cement based wall care putty (minimum 1.5mm thick) and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-after complete all as specified and as directed.
Taking down carefully unserviceable main swirtch and DB's including MCB's of any description and capacity complete all as specified and as directed.
M&L concealed point wiring for light/fan points controlled by one, one way switch with two single core 1.5 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, fan regulators, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for Modular boxes & making good to walls, floors etc. complete all as specified & as directed
All as per item No 27 here-in-above but for one 6 amps socket out let point on the same board with other switches
All as per item No 27 here-in-above but for one 6 amps socket out let point on independent board.
M&L for concealed point wiring for one socket out let 15/16 amps point on the independent board with two single core 4 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for Modular Sunken boxes & making good to walls, floors etc.complete all as specified & as directed
M&L concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of 20mm dia (Medium Grade) with all fittings and accessories ISI marked including necessary dismantling/taking out the existing unserviceable sub main wiring, cutting chases for conduits & making good to walls, floors etc complete all as specified and as directed. Notes;- (i) 2 Runs of 6Sqmm main cable and 1Run of 6Sqmm earth wire along with 1 Run of PVC conduit with acessories shall be measured as one unit length (ii) Rate is deemed to be inclusive cutting chases and making good the distrubed surfaces of wall etc (iii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED.
S&F LED lights fitting 1x 20Watt, 220Volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, complete all as specified and directed.
S&F Modular shuttered Socket outlet 3/5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and directed.
S&F Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and directed.
S&F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and directed.
S&F ceiling rose, PVC/Polycarbonate, isolated body, three terminals, complete all as specified and directed.
S&F stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 protection, double door, Triple pole & neutral, complete including blanking plates as required & flush to wall/other surface complete all as specified and directed.
S&F MCB, TPN, C Series 240 Volts, 63 Amps 50 HZ, 10KA complete all as specified and directed.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and directed.
PRITHWI BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .