Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.5 LAccepted-AOC MOCHARIM BODHGAYA GAYA 824231 | BODHGAYA | GAYA | BIHAR | 824231 | 1 | Accepted-AOC ok | |
| 2 | 2₹43.6 L+₹6.1 L (16.3%)Rejected-Finance | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹44.3 L+₹6.9 L (18.4%)Rejected-Finance D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | 3 | Rejected-Finance Quoted rate more than L1 | |
| 4 | 4₹45.3 L+₹7.9 L (21.0%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 4 | Rejected-Finance Quoted rate more than L1 | |
| 5 | 5₹45.6 L+₹8.1 L (21.7%)Rejected-Finance 20 23 MANASKAMANA ROAD BANSBARI MORE PS ENGLISHBAZAR DT MALDA | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | 5 | Rejected-Finance Quoted rate more than L1 |
Tender Value
₹42.3 L
EMD Value
₹84,540
Closing Date
20 Jul 2024, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
PROVN OF TWO CLASS ROOM FOR 40 NOS STUDENTS EACH ROOM AND ONE TOILET BLOCK AT ARMY PUBLIC SCHOOL UNDER GE DIPATOLI
2024_MES_649284_2
8000/1975/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹84,540
Yes
2 Oct 2024
29 Jun 2024
22 Jul 2024
29 Jun 2024
20 Jul 2024
6 Jul 2024
Amount
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed.
Treating the top surface of filled earth at the rate of 7.50 litres of emulsion per square metre of surface complete all as specified and directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
Material & labour for approved soil filling under the floor, spreading and levelling in layers n.exc. 25cm thick, well ramming including watering as required complete all as specified and directed.
Material & labour for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of Form work of sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete complete all as specified and directed.
M&L Form work to sides and soffits of beams and lintels etc finished rough complete all as specified and directed.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as specified and directed.
M&Lfor form work to the edge of concrete flat n. exc 200 mm thick complete all as specified and directed. .
Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply & fix mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required as in stirrups complete all as specified and directed.
M&L RCC design mix M-25 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L RCC design mix M-25 using 20 mm graded stone aggregate as in Columns, pillars etc complete all as specified and directed.
M & L RCC design mix M-25 using 20 mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed.
M&L for RCC design mix M-25 using 12.50 mm graded stone aggregate for roof slabs supported on walls, beams and the like complete all as specified and directed.
Material & labour brick work with fly ash bricks in CM 1;6 brick straight or curved on plain exeeding 6m mean radius complete all as specified.
Material & labour for brick work with sub class ‘B’ bricks, straight or curved on plan, exc. 6 metre mean radius built in CM(1:4) as in half brick thick walls complete all as specified and directed.
Supply only integral water proofing compound all as in specified & directed.
Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,in CM(1:4) surface finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M/L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed.
M&L Non Skid ceramic tiles 7-8 mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, (600 x 600) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement joint free non skid tiles.to match 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L Non Skid ceramic tiles 7-8 mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick rendering1:6 complete all as specified and directed
M&L Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed in CM 1:6 complete all as specified and directed
Material & labour for glazed coloured ceramic tiles of size 450x300x7-8mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match with existing work over and including 10mm thick rendering in CM 1:4 complete all as specified & directed.
M&L 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cement all as specified and directed.
Material & labour for preparation of new plastered surfaces of walls etc and applying two coats of cement base paint over a coat of primer complete all as specified & directed.
Material & labour for preparation of new plastered surfaces of walls with wall care putty and applying two coats of Oil bound distemper to match the existing surfaces as required, complete all as specified & directed.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
Material and Labour for 20mm thick cement paster in CM 1:4 mixed with WPC @ 2 % by weight of cement finised even and smooth without using extra cement on roof surface and wall (WPC will be measured and paid seperately as supply only rate).
Supply only liquid water proofing compound
Material & Labour for 40mm thick average thickness of PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding on roof finished even and fair without using extra cement all as specified and directed.
M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces
M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed
Supply and fix 30 mm thick flush shutter solid core construction with particle board and plywood face panels commercial type on both side complete all as spfd and directed
Supply & fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs lugs, hinges, lock strike plates etc completed size of frame 105x60mm made out of 1.25mm MS sheets complete all as specified & directed.
S &F Flat iron hold fast 25mm x 6mm welded to angle iron door frame as directed by Engr-in-Charge.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 156 of SSR 2010 (Part-II) complete all as specified and directed. .
Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified & directed.
S&F aluminium tower bolts 150mm long, of extruded section complete all as specified and directed. .
Supply & fix Aluminium. Sliding door bolts, plate type, complete, 250mm long complete all as specified and directed.
M&L preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
Supply & fixing steel C.P. grating 100/125 mm dia as reqd at site complete all as directed.
S&F for 110 mm bore PVC floor traps plain with grating and 300 mm long out let including jointing with cement concrete type B -1 1:2:4 complete all as specified & directed.
Supply and fix PVC bends 110mm bore, any radius complete all as specified & directed.
M & L Steel window box type using ERW 'P' section comprising double frame for gauged and glazed skeleton shutter jointed internally with flat iron 40x3mm complete including hinges, handle tower bolts stops, lugs etc all as shown on drawing Note (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mangeryas shown on drgs (iii) Guard bars glazing & wire mesh shall be measured & paid for separately complete all as specified and directed. .
Supply & fix steel windows or ventilators fixed type, complete all as specified & directed.
Supply & fix mild steel work as in hold fast etc and similar articles confirming Fe-310-0 with & including material & labour tarring & sanding complete all as specified & directed.
Supply & fix mild steel framed work such as grills, gratings guard bar etc with ends of bars shouldered and/ or riveted etc completed all as specified.
S&F Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed complete all as specified and directed. .
Supply & fix bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed.
Supply & fix in vitreous china wash hand basin, white, flat back of size 550x400mm (excluding taps, waste chain and plug and porcelain stopper) but including brackets suitable for 15mm dia pipe complete all as specified & directed.
Supply & fix angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed.
Supply & fix rotational moulded polyethylene water storage tanks 500 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings complete all as specified & directed.
Supply & fix in PVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
Supply, fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supply & fix 3mm thick sheet glass, ordinary quality, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed.
Supply & fix 3mm thick sheet glass, pin headed, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed.
Supply & fix galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed.
Supply & fix butt hinges, 100 mm long of stainless steel, complete all as specified & directed.
Supply & fix in PVC connections of 450mm long for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
Supply & fix PVC ball valves, high pressure with polyethylene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified & directed.
Supply & fix vitreous china squatting pan of ‘Orrisa pattern’ size 580x440mm, white with, integral foot rest including replacement of ‘P’ or ‘S’ trap, lime concrete bedding and making good floor complete all as specified and directed.
Supply & fix in vitreous china urinal half stall type with including providing & fixing of plugs bedding against wall in cement mortar 1:2 pointing around urinal back in cement mortarcomplete all as specified and directed. .
Supply & fix pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, complete all as specified & directed.
S&F Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed.
S&F waste coupling of PTMT (half or full threaded) suitable for urinals (Minimum weight 32mm-45gms) complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore complete all as specified and directed.
S&F Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
M & L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8m dia x 3.0m eff depth complete all as TD drawing No CEJZ/11/58 dt 05 May 2000 and as directed.
M & L Septic tanks, exc in ordinary soil, foundation in PCC !:2:4, brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all round / fibre reinforced cover with iron frame Vent shaft and sludgechambers etc, complete for 100 users complete all as TD drawing No CEJZ/TD/57 dt 05 May 2000 and as directed.
S&F 60 mm thick Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 , M-35 Grade with grey cement and no pigment complete all as specified and directed.
M/L 75 mm thick cement concrete 1:4:8 type D-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed.
M&L supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 Mm thick in each layer complete all as directed
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 89 here-in-before but one 3 Pin Socket out let 5 Amps on the same board, complete all as directed by Engr-in-Charge.
All as per Ser item No 89 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as directed by Engr-in-Charge.
All as per Ser item No 89 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly, complete all as directed by Engr-in-Charge.
Supply and fix Switch Piano type, single pole, one way 5 Amp, complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps, complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No- 98 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire , complete all as specified and directed.
All as per ser item No 98 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire, complete all as specified and directed.
All as per ser item No 98 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire , complete all as specified and directed.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site, complete all as specified and directed.
Supply and fix MCCB DB TPN 4 way with metal door suitable for Provision of incommer as MCCB and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
S&F MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
S&F of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed.
S&F LED tube light fitting 20 watt 230 Volt LED Lighting with aluminium housing & integrated electronic driver, including all internally pre-wired and inncluding connecting up with flexible copper conductor cable with suitable size complete all as specified and directed.
S&F of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity ,comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting up with 2/3 core twisted flexible copper conductor cable with suitable size of flexible PVC/steel Conduit , complete all as specified and directed.
S&F of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc , complete all as specified and directed.
Supply and fixing ceiling fans complete with blades down rods, electronic regulator and accessories, 230V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC)
S&F PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
Supply & Laying ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface , complete all as specified and directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement , complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M/S AMOD KUMAR PANDEY
M/s Kundu Enterprises
M/S Sweta Construction
M/s Mukesh and company
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .