Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹44.6 L+₹9.2 L (26.0%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹45.3 L+₹9.9 L (27.9%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC Not Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
27 Jul 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
Repairs Renewal of External water supply mains including control valves and Replacement of damaged CI, GI, MS Pipe lines at Station Workshop, Race course Pump house, Golden Palm, Mudfort Area, Sappers line, Hostel line, MES Officers Complex, NCC Di
2020_MES_356950_1
GE(U)/SEC/TOKEN/21 OF 2020-21
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
270 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹92,000
Yes
5 Aug 2020
30 Jun 2020
29 Jul 2020
30 Jun 2020
27 Jul 2020
15 Jul 2020
Amount
Attending repair/rectification of leakages to water supply distribution lines 20 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 1 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 4 above but for GI tubing 40 mm bore to 50 mm bore.
M&L for attending break down of water supply pipe line and repair to CI/DI/PPR water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed. Note:- CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'.
Rectification of lekages in pumping /delivery lines(GI/CI/DI/PPR) of size 80 mm to 150 mm at main/civil roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and Lead joint deemed to be included in the quoted rate.
Rectification of lekages in pumping /delivery lines(GI/CI/DI/PPR) of size 200 mm to 400 mm at main/civil roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints,filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and Lead joint deemed to be included in the quoted rate.
Notes for Sl item No 1 to 6 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 11.01 to 11.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 13.01 to 13.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
32 mm dia
50 mm dia
110 mm dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
110 mm dia
Notes for item No 16.01 to 16.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings. Make : SFMC/KPT/WETFLOW/SAFE.
32 mm dia
63 mm dia
110 mm dia
Notes for item No 18.01 to 18.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Make : SFMC/WETFLOW/SAFE.
32 mm dia
63 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
400 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
300 mm dia
400 mm dia
Notes for item No 21.01 to 21.06 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K9, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm dia
400 mm dia
Notes for item No 22.01 to 22.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
400 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Hex Nipple
All as per item No 24 above but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per item No 24 above but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per item No 24 above but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40 x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
All as per item No 24 above but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 50mm x 40mm.
Reducer 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
Hex Nipple
All as per item No 24 above but for 80 mm bore.
Union
All equal Tee
Socket
Reducer 80mm x 50mm.
Reducer 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Hex Nipple
All as per item No 24 above but for 100 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 100mm x 80mm.
Reducer 100mm x 50mm.
Reducer 100mm x 40mm.
Elbow
Reducer elbow 100mm x 80mm
Reducer elbow 100mm x 50mm
Reducer elbow 100mm x 40mm
Reducer tee 100mm x 100mm x 80mm
Reducer tee 100mm x 100mm x 50mm
Reducer tee 100mm x 100mm x 40mm
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for dismantling of defective sluice valve for repairs, such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts, washers and gland rope etc and refixing in its original position, testing on completion complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm Dia
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 34 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm Dia
S&F in repairs cast iron detachable (D-Joints) heavy duty, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) CI/GI/MS pipe for insertion will be measured and paid separately under relevant item of this schedule. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
400 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K506, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
150 mm Dia
200 mm Dia
300 mm Dia
400 mm dia
S&F, connecting and testing in repair of Cast Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, K517, PN-1.6 both ends flanged etc including jointing materials of following sizes complete all as specified and directed.
80 mm Dia
150 mm Dia
200 mm Dia
S&F, connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
40 mm Dia
50 mm Dia
150 mm Dia
200 mm Dia
S&F, connecting and testing in repair of Cast Iron double orifice kinetic Air Valve ISI Marked IS : 14845 type DK in PN 1.0 flanged end K541 with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as per specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 250 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
M&L for Construction of new PCC solid Masonry valve chamber of size 1200 X 1200 X 1200 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply only calcium Hypochlorite having 60%-70% available chlorine content in granular from (calcium based granular disinfectant) for water treatment (Drinking water and swimming pool) packed in 45 Kgs/50 kgs each drum complete all as specified and as directed. Make : M/S SHREE RAYALASEEMA Hi STRENGTH HIYPO LTD (PURI CHLOR), ALTOC-GP of M/s DECLIBAC TECH PVT LTD, POTTER AND WATTS,
Supply only for Bleaching powder grade-I, ISI marked (each bag of 25 Kgs) for using in UG sump & over head tanks at the locations of RCPH and other water supply installations for purifying drinking water complete all as specified and deoposited in store yard of AGE E/M II as directed. Make for item No 47 :- Grasim/Lion/Shaktiman Notes :- (a) contractor shall supply materials as per monthly requiremnt basis in bags/containers as and when directed at various installations of AGE E/M NO II. (b) Dails consumption quantity of each item viz, alum, ferric, bleaching powder, TCCA-90, sodiem Hypochloride etc shall be submitted alongwith each RAR. Also dails consumption of all chemicals shall be recorded in register and maintained at site. (c) The manufacturer shall comply and guarantee the authenticity of the product by providing test certificate with Hologram which will be provided by the authorised idtributor at the distribution point for each batch of product delvered on thier letter head. (d) The manufacturer will affix its hologram on each and every drum/container/bag. if the said product is delivered without the said hologram and/or it is seen to be tempered, then the product can be discard as spurious. (e) The quoted rates is deemed to be included complete labour and transportation for the materials at various installations of GAE E/M No II without any extra cost.
S&F, connecting and testing in repair of gun metal (Bronze)brass non return (reflux) volves etc including jointing materials of sizes 50/80 mm complete all s apecified and directed
Supply and fixing of DOL Starter suitable for upto 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp. Make : L&T cat part No CS90947 or equivalent of Havells/CG complete all as specified and as directed.
Supply and fixing of single phase preventer suitable for upto 7.5 HP motor. Make : L&T cat part No CS94824DOOO or equivalent of Havell/CG complete all as specified and as directed.
M&L for replacement of PVC insulated, submersible electric cables of 4 Sqmm 3 core with stranded copper conductor, 1100 volts laid in bore well including jointing and testing complete all as specified and directed.
Supply and fixing PP-R Pipe fittings and accessories 32 mm bore, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Reducer Socket 32 x 25 mm
Socket
All equal Tee
Union
Gate Valve
All as item No 52 above but 63 mm bore :-
Reducer Socket 63 x 32 mm
Socket
All equal Tee
Reducer Tee 63 x 63 x 32 mm
Union
Gate Valve
All as item No 52 above but 110 mm bore :-
Reducer Socket 110 x 63 mm
Socket
All equal Tee
Reducer Tee 110 x 110 x 63 mm
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 32 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 20 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable of 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Supply, fabrication, installation connection and testing of Feeder Pillar box outdoor type of size 1.2 m (L) x 0.6 m (W) x 1.5 m (H) (totally enclosed type) with canopy made out of 3.15 mm thick CRCA sheet with copper busbar of capacity 300 Amps with colour sleeve (RYB & N) = 04 No's with suitable size of PVC copper conductor thimbles glands for connections with angle iron 40 x 40 x 6 mm frame work allround having double hinged double door shutters on front and back with MS sliding bolts - 250 mm long for locking arrangement. The base of the feeder box shall be provided at 0.60 m above the ground level 4 Nos angle iron legs made from angle iron 50 x 50 x 6 mm shall be embedded on PCC 1:2:4 type B1 300 x 300 x 300 mm with depth below the ground level. The feeder pillar box shall be painted with two coats of synthetic enamel paint powder coated over a coat of red oxide zinc chrome primer complete internally & externally including disconnecting/taking out old existing unsv FP box complete all as specified and directed.
M&L for replacement for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 300 mm dia with 6 mm thick in any length including jointing materials to carry water supply pipe line of size upto 200 mm dia and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping & platering of valve chamber complete all as directed
Supply only sodium Hypochlorite having 12%-15% available chlorine content in liquid from for water treatment (Drinking water and swimming pool) packed in 50 kgs drum complete all as specified and as directed. Make : M/S SHREE RAYALASEEMA Hi STRENGTH HIYPO LTD (PURI CHLOR), ALTOC-GP of M/s DECLIBAC TECH PVT LTD, POTTER AND WATTS, BRIOZINGngements as in repairs complete all as specified and directed.
Supply and replace MCB SPN 20 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TPN 32 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TP 32 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 100 mm of thickness 9.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts including taking down of old unserviceable MS pipe all as specified and directed. Note: Quoted rate is inclusive of welding and cutting.
All as per Item No. 65 above but for 150 mm dia
All as per Item No. 65 above but for 200 mm dia
All as per Item No. 65 above but for 300 mm dia
M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for FILLING / FOOTHPATH/ ROAD complete all as directed
M&L for replacement of existing water level indicator in OHT of any size , capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support , PCC ,display board ,indicator/pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed. (All area undeb AGE E/m -II)
M&L for replacement of existing water level indicator in UG Sump of any size , capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support , PCC ,display board ,indicator/pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed.( Race course PH, Gough Line PH and GRPH)
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping /cleaning complete all as directed .
Supply and fixing of anodised aluminium frame and aluminium grill for ventilators / Vent Cowl of UG sump and OHT, partitions etc with one or more rebates including joining cleat for fixing etc including cleats and rubber gaskets complete all as required for fixing as specified and directed in cluding dismentling old one.
M&L for Wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of staples size of the mesh 20 mm complete al as required for fixing at Aliminium frame complete all as specified and directed including dismantling old one
M&L for painting of raising main, distribution, wash out and overflow pipes on over head tank with suitable colour coding of pipe dia 100 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out and overflow pipes on over head tank with suitable colour coding of pipe dia 150 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out and overflow pipes on over head tank with suitable colour coding of pipe dia 200 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out, pumping /delivery and overflow pipes on underground sump with suitable colour coding of pipe dia 100 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out, pumping /delivery and overflow pipes on underground sump with suitable colour coding of pipe dia 150 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out, pumping /delivery and overflow pipes on underground sump with suitable colour coding of pipe dia 200 mm by using synthetic enamelled paint first grade after scrapping /cleaning
Sypply and fix Clamp set of 2 made out of 50X5mm GI strip suitable for 80/100/150 mm GI/CI/DI/MS pipe including 2 nos galvanised nut bolts complete all as directed
Sypply and fix Clamp set of 2 made out of 50X5mm GI strip suitable for 200/300 mm GI/CI/DI/MS pipe including 2 nos galvanised nut bolts complete all as directed
Disconnecting, dismantling and taking aside the Pump set of 180 to 220 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 180 / 220 HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump set testing and commissioning all as specified and directed. Note:The quoted rate will be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation.
Srinivasa Consructions
STANDARD AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .