Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.6 L+₹69,815.60 (1.56%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹47.0 L+₹2.1 L (4.77%)Rejected-Finance 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L3 | Rejected-Finance L3 | |
| 4 | L4₹48.1 L+₹3.3 L (7.24%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹49.6 L
EMD Value
₹99,200
Closing Date
3 May 2025, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SPECIAL REPAIR TO BLDG. NO. P-31 DS OFFRS MESS OF 125 SATA REGT AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2025_MES_702374_1
GE/JULL/ET-83/2024-25
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹99,200
11 Jun 2025
24 Mar 2025
10 May 2025
24 Mar 2025
3 May 2025
19 Apr 2025
Amount
Demolition of cement concrete of any description and in any position and removing surplus spoil out of defence land complete all as specified and directed
M&L for 50mm PCC 1:3:6 type C-2 as in plinth protection and path finishing the surfaces even and smooth without using extra cement complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified
M&L for Vitrified Ceramic tiles (premium quality) light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm, but not exceeding 1.00 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl. 15mm thick cement screed bedding layer in cement mortar 1:6 complete all as specified and directed. Make:- Kajaria/Somany/Johnson
All as per item No 4.00 here-in-before but on vertical surfaces such as skirting etc over and including 10 mm thick cement plaster finished even and rough to receive tiles in cement mortar (1:4) complete all as specified
M&L for non skid joint free ceramic coloured tiles (premium quality) of area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and 6-7 mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. Make:- Kajaria/Somany/Johnson
M&L for coloured glazed tiles of size 300x450x6-7mm thick fixed with neat cement slurry in vertical surface to wall pointing in white/coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed
M&L for Chequered cement concrete tiles 25 cm x 25 cm x 20 to 22 mm thick, with grey cement and pigment, set jointed and pointed in neat cement slurry in floor laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified.
Demolition of reinforced cement concrete of any description not exc 15 cm thickness (reinforcement to cut as required to facilitate demolition) all as directed.
M&L for reinforced cement concrete 1:2:4 nominal mix type B-1 slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified
M&L for MS TMT bars 10 mm and over dia and cut to length, bent to shape required incl cranking bending spirally for hooping for column hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for form work to soffits to suspended slabs, floor slabs, shelves, landings and similar work, not exceeding 200 mm thick (horizontal or slopping) rough finished surfaces of concrete flat or shelf etc complete all as specified
M&L for form work to edges of concrete flats, breaks in floors, window cills, concrete railings, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 10cm but not exc 20 cm wide rough finished surfaces of concrete all as specified
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 15mm thick bedding layer CM 1:6 including dismantling old granite complete all as specified and directed
M&L for 18 to 20mm thick machine cut Kota stone in flooring laid over and including 15mm thick screed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the colour of stone slab including rubbing and polishing complete all as specified and directed
S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white (excluding flushing cistern) incl seat cover and flushing pipe for pedestal pan, including all joints complete all as specified and directed. Make:- Hindware/Parryware/Cera
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. Make:- Jaguar/Cera/ESS-ESS
S&F in repair chromium plated Jet for EWC 600mm long tube superior quality all as specified and directed.
S&F in repair PVC valveless, syphonic action type flushing cistern low level, white, with inlet, ball valve, float and handle, 10 ltr capacity including brackets complete all as specified and directed. Make:- Hindware/Parryware/Cera
S&F in repair for Vitreous china wash hand basin, white flat, oval shape incl brackets and waste coupling and waste pipe of any size complete all as specified and directed. Make:- Hindware/Parryware/Cera
S&F vitreous china urinal full stall type flat back complete incl providing and fixing plugs bedding urinal against wall in CM(1:2) securing urinal to plugs with and incl 60 cm long brass screws, pointing around urinal back in cement incl and fixing and flush pipe, grating with coupling and union for discharge complete all as specified and directed. Make:- Hindware/Parryware/Cera
S&F CP Bib tap cast copper alloy suitable for 15mm bore iron pipe with long body fancy type complete fixed in repair complete all as specified and directed. Make:- Jaguar/Cera/ESS-ESS
S&F in repair Pillar tap, brass with capston head, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or cold with long screwed for 15mm bore iron pipe and fixed complete all as specified & directed. Make:- Jaguar/Cera/ESS-ESS
S&F brass chromium plated tubular towel rail 20 mm dia , D type 60 cm long between CP flanges all as specified. Make:- Jaguar/Cera/ESS-ESS
S&F in repair Acrylic corner set of 3 pieces complete all as specified and directed
S&F Corner glass shelf with bracket complete all as specified and directed.
S&F brass chromium plated shower rose of 75mm size, with or without swivel joints including fixing to steel pipe or union fixed in repairs complete all as specified and directed. Make:- Jaguar/Cera/ESS-ESS
S&F 15mm stop valves, fancy type, cast copper alloy, chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed. Make:- Jaguar/Cera/ESS-ESS
S&F PVC connection fibre, reinforced 45cm long with brass check nut and PVC washers at both ends complete all as specified and directed.
S&F rotational moulded synthetic (HDPE), water storage tank UV protected, antimicrobil triple layer (white) 1000 litre capacity (Cylindrical vertical with closed top), hoisted & fixed in position all as specified in SSR Part-I, including dismantling of existing water tank complete all as specified and directed. Make:- Sintex Pure/Sheetal/Rotex
S&F 15mm Brass CP mixer for mixing hot & cold water for WHB with all fittings screwed down for iron pipe complete all as specified and directed. Make:- Jaguar/Cera/ESS-ESS
M&L for galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, and or laid in floors etc including taking down the existing tubing complete all as specified
M&L for galvanised iron water tubing 20 mm bore, medium grade with & including all fittings fixed to wall, and or laid in floors etc including taking down the existing tubing complete all as specified
Dismantling of brick tiles single layer as in roof covering complete all as specified
Demolition of mud in roofs any thickness including plastering and leaping (whether full thickness removed or only a part there of) all as specified
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B1 (using 20mm graded aggregate) as in road kerbs or mud stops set in CM 1:4, including weathering, slightly rounded or chamfered angles and throating all as specified and directed
M&L for 10mm thick cement plaster with WPC in cement mortar 1:3 on concrete roof surfaces finished even and fair, complete all as specified and directed
M&L for Bitumen Primer shall be applied on plastered surface of roofs at the rate of 0.40 Kg/ Sqm of Surface area of roof for use in water proofing and dump proofing treatment complete all as specified
M&L for Painting the roof surface with a coat of hot blown paving industrial bitumen 85/25 as a bonding material in two coats one on primed surface & 2nd on APP based polymeric membrane at the rate of 1.20 kg/sqm all as specified
M&L for APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick reinforced with five layer polyster non wove fabric ( wt. Not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
M&L for 40 mm thick brick tiles with 15 mm thick bedded layer of 1:3 CM laid on 2nd bitumen coated surface and joints grouted flush mortar 1:3 mixed with 5% of crude oil by weight of cement, complete all as specified .
All as per Srl Item No 43.00 here-in-before but except tiles
M&L for cutting out cracks to V-section in existing RCC roof slabs or terracing , cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) all as specified
M&L for flush pointing in cement mortar 1:3 on brick tiles laid flat on roof and wall surfaces complete all as specified
Demolition and braking up drain pipes AC/PVC pipe in event n.exc 150 mm dia including all fittings complete all as specified
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls and floors complete all as specified and directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F for 110mm PVC (SWR) vent cowl complete all as specified and directed.
Taking down chowkats or frame not exc. 1.5 sq m each with shutters (without taking off shutters from the fames) complete all as specified
Taking down chowkats or frame exc. 1.5 sq m but n.exc 4 sq m each with shutters (without taking off shutters from the fames) complete all as specified
M&L anodized Aluminium Powder Coating (minimum thickness of powder coating 50 micron) door shutter having 150mm x 44mm x 2.85mm thick bottom rail, 150mm x 44mm x 3mm thick midle rail, 100mm x 44mm x 2.85 thick stile and top rail inclluding necessary fitting joinery cleat, glazing paacking snap beading 10mm x 10mm , aluminium handle 200mm long (02 Nos), 03 Nos 100mm size chromium plated butt hinges, 2 Nos 200mm size aluminium tower bolt and aluminium body hydraulically door closer, designataion No-3, universal type, weight between 61 to 80 Kg etc including frame of section 100mm x 44mm x 2.85mm adn door shutter, 5.00 mm thick tinted glass and pattern, 100mm x 44mm x 2.85mm and levers brass body (Make : Harrison) and fixing including taking down of exsisting Chowkat make of aluminium section Hindalco/ Jindal.
M&L anodized Aluminium Powder Coating (minimum thickness of powder coating 50 micron) window/ ventilator shutter sliding type having 75mm x 44mm x 2.85mm thick stiles bottom rail and top rail including necessary fiting joinery cleat glazing packing snap beading 10mm x 10mm , 2 Nos of aluminium handle 150mm size etc including frame three track of section 100mm x 44mm x 2.85mm and including 5.00 mm thick tinted glass and including aluminium deco grill 50mm x 50mm mesh size and 5.5mm thick and fixing including taking down of exisitng chowkat with shutter complet all as specified and directed. Make of aluminium sections Hindalco/ Jindal.
S&F PVC solid door frame of size 50mm x 47mm made out of 5 mm wood grain printed PVC sheet and edges will be painted to be matched with shutter, reinforced with MS square tube, as per specification and drawing in SSR Part-II complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutters with particle board core, 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front Face & 2mm Prelam PVC sheet on back face all as per specification & drawing
S&F 100mm butt size brass butt hinge to PVC doors, complete all as specified and directed
S&F 125mm size extruded brass handles, fabricated type complete all as specified and directed.
S&F 250mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts and fixed complete all as specified and directed.
S&F 150mm size brass barrel tower bolt, of extruded section complete all as specified and directed.
Excavation in post holes (or similar holes) in soft/loose soil, each not exceeding 0.50 cum and getting out, returning, filling in and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, including watering and removing surplus soil to a distance not exceeding 50m away from the starting point and making good surfaces complete all as directed.
M&L for PCC (1:3:6) type C-2, (using 40mm graded stone aggregate) as in foundation, mass fillings for posts/struts etc. complete all as directed.
M&L for Rolled sections as in vertical member, rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (GdeE-250) quality A, complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel roof sheet 0.50 mm thick having tensile strength of 550 Mpa fixed with self drilling screws as specified. Make;- Tata Blue Scope/JSW
Dismantling of brick work or stone/boulders masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc. and rubbish materials remove from site all as specified and directed
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on internal surface of brick or concrete surface finished even and smooth without using extra cement all as specified.
M&L for 15mm thick cement plaster in cement mortar 1:4 on external surface brick or concrete surface finished even and fair without using extra cement all as specified.
Supply only integral water proofing compound (ISI Marked) all as specified
M&L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified.
M&L for preparing new plastered surfaces of walls and applying two coat of acrylic exterior emulsion paint over a coat of wall primer complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated wall surface and applying two coats of acrylic exterior emulsion paint over a coat of wall primer complete all as specified and directed.
M&L for preparation of old decorated/treated surface of walls including removing existing treatment by rubbing, scrapping, washing and applying one coats of oil bound distemper including a coat of 3mm thick wall care putty on walls complete all as specified
M&L for preparation of old decorated surface of walls and applying one coats of white (Lime) wash complete all as specified.
M&L for preparation of old surface of ceiling and applying one coats of white (Lime) wash complete all as specified.
M&L for preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, not otherwise described over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of steel surfaces exceeding 10 cm with or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair factory made 18mm thick 100% solid WPC (wood polymer composite) plain board of required size kitchen cabinet as in partition, shelves, wall, drawer, shutter, etc of required colour comprising of virgin PVC resign of value 57-60 (suspension Grade), Calcium carbonate and natural fibres (wood powders/rice husk/ wheat husk) and non-toxic additives, made from extrusion process WPC foam sheet single extruded (inner) with density not less than 650 kg/cum manufactured by certified company having good screw holding capacity (screw withdraw strength of 2000 N (face) & 1100 N (edge) minimum compressive strength of 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance of spread of flame of class A category with property of being Termite/Borer free, water/moisture proof, Fire Retardant fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws. All as per direction , material test certificate and authentication should be compulsory/provided by the manufacturer company Make : - Rajshree
All as per Srl item No 80.00 here-in-before but Solid WPC (wood polymer composite) board decorative one side complete all as specified and directed
S&F stainless steel self closing hinge of 75mm size for PVC door shutter/kitchen cabinet complete all as specified and directed.
S&F 50x15 mm size magnet door catcher for closing PVC shutter complete all as specified and directed.
M&L for surface dressing n.exc 15 cm deep in any type of soil all as specified and directed
M&L for broken stone or boulder hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed
M&L for 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade aggregate) as in sub base of flooring complete all as specified and directed
M&L for 25mm sand cushion, filling under floors or in foundations including watering and consolidation all as specified and directed
M&L for laying 80 mm thick machine pressed precast concrete interlocking paver block coloured any shape and size conforming to IS -15656-2006 of M-35 Grade with grey cement and pigment complete all as specified and directed. Note:- The sample shall be got approved from GE before placing bulk order and lot shall be got tested independety by GE.
S&F Text/Track floor panel of size 6 feet x 1 feet precast M35 SFRC (brass coated steel fiber reinforced concrete) tile of size 1200 x 600mm and 40mm thick to be casted in customised rubber mould using coloured concrete made of UV resistant pigment and minimum 5% content of steel fiber. The cycle logo for light transmission is made by embedding 6mm thick acrylic milky white sheet (040 grade). The top surface is to be grinded and polished (with final coat of deep penetration lithium silicate based sealer. The rear side of acrylic is to be filled with extra clear transparent epoxy to enhance rigidity of embedded acrylic and seal the interface joint of acrylic and concrete. Waterproof LED strips (osram/Ledvance) of grade IP68 and warm white colour tone (4000k) is to be fixed on waterproof & termite resistance board and placed 35mm beneath the SFRC tile for uniform light transmission. Duly primed and painted metal frame work to be pasted using PU adhesive (Keralastic/ kerakol) onto the SFRC tile with sufficient support provided and with additional base frame for light board to be used complete all as specified and directed
S&F Running logo panel of size 3 feet x 3 feet precast M35 SFRC (brass coated steel fiber reinforced concrete) tile of size 1200 x 600mm and 40mm thick to be casted in customised rubber mould using coloured concrete made of UV resistant pigment and minimum 5% content of steel fiber. The cycle logo for light transmission is made by embedding 6mm thick acrylic milky white sheet (040 grade). The top surface is to be grinded and polished (with final coat of deep penetration lithium silicate based sealer. The rear side of acrylic is to be filled with extra clear transparent epoxy to enhance rigidity of embedded acrylic and seal the interface joint of acrylic and concrete. Waterproof LED strips (osram/ Ledvance) of grade IP68 and warm white colour tone (4000k) is to be fixed on waterproof & termite resistance board and placed 35mm beneath the SFRC tile for uniform light transmission. Duly primed and painted metal frame work to be pasted using PU adhesive (Keralastic/ kerakol) onto the SFRC tile with sufficient support provided and with additional base frame for light board to be used complete all as specified and directed
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light, accessories for taking credit of unserviceable light and accessories as per Sch of credit and making good disturbed surface of walls, roof, floors etc. with any type of civil wk involved complete all as specified and directed
M&L for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate.)
All as per Srl item No. 92.00 here-in-before but for one fan point controlled by one switch complete all as specified
All as per Srl item No. 92.00 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified
All as per Srl item No. 92.00 here-in-before but for one socket outlet 5 Amps on the same board controlled complete all as specified
All as per Srl item No. 92.00 here-in-before but for one bell point controlled by one bell push complete all as specified
M&L for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independent board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included)
S&F Modular switch piano flush type, 6 Amps AC single pole, one way complete all as specified.
S&F Modular switch piano flush type, 16 Amps AC single pole, one way complete all as specified.
S&F Modular socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
S&F Modular socket outlet multi purpose 2 in 1, 5/6 pin, 6 & 16 Amps, flush type complete all as specified.
S&F ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified.
S&F in replacement Modular bell push switch flush type 5 Amps, single pole, one way complete all as specified and directed.
M&L in replacement Bell electric AC (Ding Dong) 240 volt SP complete all as specified.
S&F 2 Module five step fan regulator, electronic type, single phase, including connection complete all as specified.
Supply and fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed.
S&F 1 Module blank (dummy) plate suitable for Modular switch cover plate complete all as specified.
S&F LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S&F LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily
S&F in repair Decorative wall mounting light fitting suitable for 09/10 watt LED lamp complete with glass shade/ polycarbonate cover including 09/10 W LED lamp complete all as specified and directed by Engr-in-Charge
S&F energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S&F LED flood light 50 watt 230 V,AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. Make of Sr Item No. 112 to 116:- Crompton/Havells/Philips
S&F surface mounted round LED panel light fitting, dia cast body with diffuser to ensure glare free light, 12 watt 220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED retrofit lamp 9W, 6500K, 220-240V with base cap B-22 complete all as specified and directed
S&F LED light fitting 1 x 9/10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/ Isolator etc, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessary complete all as specified and directed by Engineer-in-Charge. Note :- MCB/ Isolator etc shall be measured and paid separately under appropriate item of BOQ
S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/ Isolator etc, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessary complete all as specified and directed by Engineer-in-charge. Note :- MCB/ Isolator etc shall be measured and paid separately under appropriate item of BOQ
S&F MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and directed by Engineer-in-Charge. Make of Sr Item No. 119 to 126:- ABB/Legrand/Schnieder
S&F MCB ‘C’ curve suitable for 230 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and directed by Engineer-in-Charge
S&F single pole and neutral enclosure with a two pin and earth plug and socket (for Geysers/ AC) complete with one single pole MCB of 20 amp 240 V 10 KA complete all as specified and directed
S&F in replacement MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type incl complete connection with suitable spreaders complete all as specified and directed by Engr-in-Charge
S&F in replacement MCCB TPN 63 Amps, 415 Volts, 16KA, 4 pole, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreaders complete all as specified and directed by Engr-in-Charge
S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessary complete all as specified and directed by Engineer-in-Charge
S&F in repair TPN double door DB 4 way with Bus Bars, Neutral Links, blanking plates suitable for fixing of TPN upto 63A as incomer and MCB for outgoing fixing in wall all as specified and directed
S&F exhaust fan, steel body AC single Phase 230V of size 230mm sweep with, blades, and frame and louvers complete all as specified and directed
M&L for cutting holes for exhaust fan of size 230mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built inline mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified
Taking down carefully exhaust fan of any sweep or make, painting of fans complete (as per previous colour) with synthetic enamel paint by spraying, cleaning all dust etc including replacement of flexible wire and minor repair work and re-fixing the same complete all as specified
Taking down geyser of any capacity or model after disconnecting all water supply and electric connections and re-fixing the same with new fastner, connecting all water supply and electric connections testing and commissioning complete all as specified
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multi-stranded copper conductor cable 4.0 Sqmm (green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note: Two run of 4.0 sqmm wire and one run of 4.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm (green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note: Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 10.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 10.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note: Two run of 10.0 sqmm wire and one run of 10.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L for sub main wiring (Three Phase) with four run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 10.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 10.0 Sqmm (green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note: Four run of 10.0 sqmm wire and one run of 10.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3½ core complete laid in trenches passing through pipes/ culverts/ under roads/ along wall all as specified and as directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and directed
M&L for returning, filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. (Surplus soil if any shall not be removed but left over the trench)
M&L for removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I
M&L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site
Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 91.00, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed
M&L for earthing complete in replacement with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner
ASHOK KUMAR MAHAJAN (BID ID -3291216)
NIRMAL SINGH (BID ID -3287808)
M/S Vinod Kumar (BID ID -3290777)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .