Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹58.2 LAdmitted-Finance | -23.10% | ₹58.2 L | L1 | Admitted-Finance |
| 2 | L2₹58.6 LAdmitted-Finance | -22.60% | ₹58.6 L | L2 | Admitted-Finance |
| 3 | L3₹60.6 LAdmitted-Finance | -19.87% | ₹60.6 L | L3 | Admitted-Finance |
| 4 | L4₹60.9 LAdmitted-Finance | -19.56% | ₹60.9 L | L4 | Admitted-Finance |
| 5 | L5₹64.3 LAdmitted-Finance | -14.99% | ₹64.3 L | L5 | Admitted-Finance |
Updated dates
Tender Value
₹75.7 L
EMD Value
₹1.5 L
Closing Date
4 May 2026, 6:00 pmClosed
SE PHED SALUMBER
SE PHED SALUMBER
Construction of New 300 KL OHSR 18 Mtr Stagging Near Ghati Darwaja and Providing laying and jointing of Rising and Distribution Main Pipe line UWSS Salumber Under DMFT District Salumber
2026_PHCJA_551428_1
NIT 05/2026-27 Under SE PHED SALUMBER
Open Tender
Civil Works - Water Works
270 days
SALUMBER
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
EE PHED SALUMBER
₹1.5 L
Yes
14 May 2026
13 Apr 2026
5 May 2026
13 Apr 2026
4 May 2026
13 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | - | - | - | - |
| 2 | 200 MM | - | RMT | - | - |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:
All kinds of soil | - | Cum | - | - |
| 4 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:
Ordinary rock | - | Cum | - | - |
| 5 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - | - | - | - | - |
| 6 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.
c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.
d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.
e) Conducting successfully hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.
g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container.
i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.
j) Providing and fixing water level indicator (float type). | - | - | - | - |
| 7 | k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.
l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.
m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).
n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.
o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.
q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.
r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. | - | - | - | - |
| 8 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M | - | - | - | - |
| 9 | 300 KL capacity at Shani Maharaj Mandir | 3,00,000 | Litre | - | - |
| 10 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
TDSE5.pdf
Tender Documents • 23.70 MB
BOQ_982709.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid