Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC N A | NA | NA | 121004 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹36.9 L+₹4.2 L (12.7%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹68.7 L+₹35.9 L (109.8%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Nov 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
CERTAIN WATER SUPPLY REPAIR WORK DURING REPUBLIC DAY CAMP AT NCC PRADE CAMP NCC GROUND NCC CADET LIVING AREA AND CERTAIN LINES FEEDING TO CGDA DGDA AIR FORCE NAVAL HQ UNDER GE U WATER SUPPLY DELHI CANTT 10
2024_MES_678205_1
GE/WS/Token-24 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹96,000
Yes
30 Dec 2024
5 Oct 2024
4 Nov 2024
5 Oct 2024
2 Nov 2024
19 Oct 2024
Amount
Providing labour only for attending day to day external water supply complaints of all nature i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply,taking out water water from trenches during repair including noting the complaints in complaint register complete all as directed by Engineer-in-charge. (Note:- (i) Any material required for attending complaints shall be measured and paid separately under respective item herein after and Quoted rates shall be deemed included cost as per notes mentioned at srl No. 1.01 to 1.02 below (ii) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate number of helpers as directed by Enginner-in-charge.
(iii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint. (iv) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor or his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply /Electric supply and if earth work is required, then the same shall be executed and measured paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the quoted unit rate rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.)
(vii) All T&P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contracor alongwith safety equipments. (viii) The pipe fitter shall always be in possession of die set complete with cutters , Taps , Pipe wrench, Chain wrench,Caulking tools,Complete set of spanners and ladders etc…, as required at site. (ix) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site. (x) Ols u/s materials obtained from replacement through item No (2) to (14.05) of BOQ shall be taken on charge in concern scrap under demolition / salvage register. (xi) A BOO will be ordered for getting verified of daily consumption of petty repair fittings/fixture items supplied by contractor and issue through Baby Indent daily wise as per received complaints.
Supply only in replacement of Unserviceable Tank nipple 20 mm dia including all fitting & fixtures complete all as specified and directed. (Note:- Labour component shall be deemed included in quoted unit rate of item No (1) above).
Supply only in replacement of Unserviceable GI Socket Medium grade ISI Marked of following sizes ;- (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply only in replacement of Unserviceable GI Elbow Medium grade ISI Marked of following sizes : - (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply only in replacement of Unserviceable GI Union Medium Grade, ISI marked of following Sizes:- (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply only in replacement of Unserviceable GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following sizes:- (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply onlyg in replacement of Unserviceable GI Reducing socket medium grade ISI marked of the following sizes :- (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
25 mmx15mm bore
20mmx15mm bore
25 mm x 20 mm bore
50 mmx 40mm bore
40 mmx 20mm bore
40 mmx 25mm bore
50mmx 25mm bore
Supply only in replacement of Unserviceable GI Tee Medium grade ISI Marked of following sizes : - (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15mm x15mm x15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
25 mm x 25 mm x 20 mm
40 mm x 40 mm x 40 mm
40 mm x 40 mm x 20 mm
40 mm x 40 mm x 25 mm
50 mm x 50 mm x 50 mm
50 mm x 50 mm x 40 mm
50 mm x 50 mm x 25 mm
50 mm x 50 mm x 20 mm
Supply only in replacement of Unserviceable GI solid plug heavy duty ISI marked of following sizes :- (Note:- (i) Excavation & earth work shall be measured and paid seperately under respective items of BOQ. (ii) Labour component shall be deemed included in quoted unit rate of item No (1) above).
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only Lead pig bar in sealed container for use in joints complete all as specified and directed.
Supply only spun yarn in bundels complete all as specified and directed.
Supply only 3mm thick rubber gasket sheet complete all as specified and directed.
Supply only lead wool best quality complete all as specified and directed.
Supply only in replacement of UNSV PTMT float valve with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and directed by Engineer-in-charge:- (Note:- Labour component shall be deemed included in quoted unit rate of item No (1) above).
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Excavation in trenches not exc.1.5m wide and not exc. 1.5m in depth including getting out in soft/loose/ Hard soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed
M&L Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. (Note:-Location & depth of boring holes is as directed by EIC)
Taking up Cast Iron/Ductile Iron water mains (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead all as specified and directed by Engr-in-charge of the following sizes :- (Note:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of CI/DI pipe in 'RM' and lead in 'KG'shall be taken into account and attach with RAR/F Bill) (b) Excavation and earth work shall be measured and paid seprately under respective items.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Re-laying only in trenches CI/DI/Cement pipe pipes with socket and spigot ends, cleaning thoroughly and removal of all blockages if any complete all as specified and directed by Engr-in-Charge for the following size/bore of pipes. (Note : (i) Joints and CI/DI fittings shall be measured and paid seperately (ii) Old serviceable pipe retrieved from item No 19 shall be considered in after relaying cleaning).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Taking down old unsv GI/CI/DI/Cement/PVC pipe, joints, bends, elbow, tees, rubber joints complete all as specified and directed by Engr-in-Charge. (Note:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV weight in (KG) shall be taken into account and attach with RAR/F Bill) (b) Excavation and earth work shall be measured and paid seprately under respective items.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
M&L for CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of following sizes confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fittings in weight (KG) shall be taken into account and attach with RAR/F Bill)
Upto 150mm bore
200mm to 250mm bore
M&L for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of following sizes confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fittings in weight (KG) shall be taken into account and attach with RAR/F Bill)
Upto 150mm bore
200mm to 250mm bore
Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore:-
80mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
M&L for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :-
80mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Taking down old unsv MS pipe, joints, bends, elbow, tees upto 350 mm dia complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material MS pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Labour for cutting, welding of CI /DI/GI/MS pipe in position for reducing to required length for insertion of new tees, branches, buterfly valve (wafer type) etc of upto 300 mm bore complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line all as directed by Engr-in-Charge. (Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
350 mm bore
Supplying and fixing, MS flanges of following sizes not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed by Engr-in-Charge. Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of MS flange in weight (KG) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
350 mm bore
M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and directed by Engr-in-Charge.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking down of existing sluice valve complete all as specified and as directed. (Note:- Old unserviceable sluice valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
350 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRVcomplete all as specified and as directed at site by the Engr-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old unserviceable NRV shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
300 mm bore
Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed by Engr-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item (ii) Old unserviceable foot valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable water meter of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- (i) Flange Joints Including Jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s water meter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of water meter in number (EACH) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking up or down GI tubing and connections of the following sizes from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed by Engr-in-Charge :- (Note:- (a) Old U/s GI tubing obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV weight in (KG) shall be taken into account and attach with RAR/F Bill) (b) Excavation and earth work shall be measured and paid seprately under respective items.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Re-fixing/re-laying only GI pipe medium grade with all new fittings fixed complete to walls and ceiling or in floors on old/new position as directed of following sizes :- (Note:- Old serviceable GI pipe obtained from item No 36 shall be used after cleaning.)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve complete all as specified and directed :- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of gun metal gate valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Material and labour for fixing of water pressure gauge (0-5 Kg/cm square) 100mm dial size including boring, threading, welding in CI/DI/GI/MS of any sizes and connected with suitable size of U type MS/CP pipe with ON OFF cock all as specified and directed by Engr-in-Charge.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed at site by the Engr-in-Charge. (Note:- Old U/s brick / brick bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV volume in (CUM) shall be taken into account and attach with RAR/F Bill)
Material and labour for rendering 15 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed by Engr-in-Charge.
Material and labour for GI tubing 'medium grade' with all accessories including bends, elbow, socket in surface/wall/trench and including taking down old unsv GI pipe complete all as specified and directed. (Note:- (a) Old U/s GI tubing obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV weight in (KG) shall be taken into account and attach with RAR/F Bill) (b) Excavation and earth work shall be measured and paid seprately under respective items.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply, installation and testing flanged ends strainer/dirt box rating (PN 1.0) of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of strainer/dirt box in weight (KG) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
M&L for contruction of valves pit chamber having internal dimension 90cmx90cmx90cm (internal height) with PCC sub base in PCC (1:4:8) using 40mm graded crushed stone aggregate for foundation 150mm thick, 23 cm brick wall in cm (1:4) 15mm thick rendering all around the brick work in cement mortar 1:6 and included PCC (1:2:4) type B1 as in coping with 20mm graded crushed store aggregate for grounting MS frame incl 6mm thick MS top sheet cover with locking arrangement incl 50mm pad lock with double key arrangement. MS frame made out of 40x40x6mm thick angle iron incl painting of steel surface with two coats of syenthetic enamel paint over a coat of red oxide primer as finishing coat incl necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50mtrs all as specified and including demolition/ dismantling of exsiting valve chamber as directed by the Engr-in- charge. (Note:- Old U/s brick & MS work obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of volume in (CUM) and weight in (KG) shall be taken into account and attach with RAR/F Bill)
M&L for construction of valves pit chamber having dimension 120 cm X 120cm x 120cm (internal height ) using PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate for foundation 15 cms thick. brick wall 23 cm thick built in CM (1:4), 15mm thick rendering all around the brick with 1: 6 cement mortor, PCC (1:2:4) type B1 (using 20mm graded crushed stone aggergate) as in coping for grouting MS frame including 6mm thick MS top sheet cover with locking arragnement, MS frame made out of 40 X 40X 6mm thick angle iron including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any type soil, returning, filling in and removal of surplus soil to a distance not exceeding 50mtrs all as specified and including demolition/ dismantling of exsiting valve chamber as directed by the Engr-in- charge. (Note:- Old U/s brick & MS work obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of volume in (CUM) and weight in (KG) shall be taken into account and attach with RAR/F Bill)
Supply & fixing for mild steel work for tank cover of RRC OHT/UG Sump/valve pit cover etc made of MS angle /sheet/flats/channels etc including cutting of top and botttom to required shape as directed,drilling holes & welding work etc and similar works confirming Fe-290,Gde E-165 complete including two coat of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed. (Note:- Old U/s MS frame cover obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
M&L for painting on steel and iron surfaces with two coat of synthetic enamel paint as per existing colour scheme or pattern after preparation of old painted surface of any description over 10cm in width or girth complete all as specified and as directed by Engr-in-charge
Supply & fixing in replacement of UNSV 15 mm bore Bib tap standard of PTMT any colour high pressure screwed for male/ female treaded of size 15mm bore weight not less than 75gram complete all as specified and directed. (Note:- Old U/s PVC bib tap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of PVC scrap weight in (KG) shall be taken into account and attach with RAR/F Bill)
Rahul Enterprises (BID ID -3147883)
tarun construction co (BID ID -3155827)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .